BioQuest BIO2 201-PS-C User manual

11-APR-1997
BIO2
Domestic Spa Bromine Generator
READ THE LABEL AND OPERATOR=S MANUAL BEFORE USING
Over Bromination (greater than 10 PPM) may cause
corrosion to some spa components.
Check the spa water bromine level on a regular basis
(weekly) to ensure the bromine level is between 3-5 PPM.
Heavy use of the spa (excessive contamination) may
require longer recovery times. (A return to minimum of
3 ppm bromine). Recovery time may be reduced by adding
a shock compound to the water.
CERTIFIED TO COMPLY WITH THE LIMITS FOR A
CLASS B COMPUTING DEVICE PURSUANT TO
SUBPART J OF PART 15 OF THE FCC RULES.
MODEL 101-PS-C
INPUT: 120 VAC .7 Amps, 60 Hz
OUTPUT: 20 VDC 3.5 Amps
EPA Est. NO. 69439-NV-001 (US)
REG. NO. 24694
PEST CONTROL PRODUCTS ACT
PATENT No. 5,545,310 OTHER PATENTS PENDING
BioQuest
4750 Longley Lane #202
Reno. NV 89502
CUSTOMER HELP DESK 1-800-516-4028
BIO2
Domestic Spa Bromine Generator
READ THE LABEL AND OPERATOR=S MANUAL BEFORE USING

Over Bromination (greater than 10 PPM) may cause
corrosion to some spa components.
Check the spa water bromine level on a regular basis
(weekly) to ensure the bromine level is between 3-5 PPM.
Heavy use of the spa (excessive contamination) may
require longer recovery times. (A return to minimum of
3 ppm bromine). Recovery time may be reduced by adding
a shock compound to the water.
CERTIFIED TO COMPLY WITH THE LIMITS FOR A
CLASS B COMPUTING DEVICE PURSUANT TO
SUBPART J OF PART 15 OF THE FCC RULES.
MODEL 201-PS-C
INPUT: 240 VAC .3 Amps, 50/60 Hz
OUTPUT: 20 VDC 3.5 Amps
EPA Est. NO. 69439-NV-001 (US)
REG. NO. 24694
PEST CONTROL PRODUCTS ACT
PATENT No. 5,545,310 OTHER PATENTS PENDING
BioQuest
4750 Longley Lane #202
Reno. NV 89502
CUSTOMER HELP DESK 1-800-516-4028
BIO2
DOMESTIC SPA BROMINE GENERATOR
OPERATOR=S MANUAL
BioQuest
INTRODUCTION
Be sure to read this manual in its entirety since it will
clearly explain how to get the greatest benefit from your BiO2
system.
If you require additional explanations or need information not
contained in this manual, please contact your spa retailer or

contact BioQuest directly at 1-800-516-4028.
Right now would be the best time to fill out your warranty
card, to register your system. Registration will facilitate
the management of your warranty and alert you to future
upgrades and discounts.
With this manual you should have received the BiO2 Start Up
Kit.
If you do not receive it with your system, call your spa
dealer
so they may be provided.
FCC INSTRUCTION TO THE USER
This equipment has been tested and found to comply with the
limits for a class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate
radio frequency energy and if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more
of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected .
Consult the dealer or an experienced radio/TV technician for
help.
This equipment has been certified to comply with the limits
for a class B computing device, pursuant to FCC Rules. In
order to maintain compliance with FCC regulations, shielded
cables must be used with this equipment. Operation with
non-approved equipment or unshielded cables is likely to
result in interference to radio and TV reception. The user is
cautioned that changes and modifications made to the equipment
without the approval of manufacturer could void the user's

authority to operate this equipment.
CONTENTS
BiO2 System Components 1
Touchpad Controls 2
Operating BiO2 3
Getting Started 3
Establishing and Testing the Bromine Level 3
Choosing the Maintenance Level 4
Protecting your Touch Control Settings 6
Regular Maintenance 7
Troubleshooting 8
Diagnostic Feature 8
Conditions 9
Flashing service light/fault codes 12
Copyright
This manual is copyrighted by BioQuest, Inc., with all rights
reserved. Under the copyright laws, this manual may not be
reproduced in any form, in whole or in part without the prior
written consent of BioQuest, Inc.
Disclaimer
BioQuest Inc. has reviewed this manual thoroughly in order
that it be an easy guide to your BiO2 sanitizing system. All
statements, technical information and recommendations in this
manual and in any guides or related documents are believed
reliable, but the accuracy and completeness thereof are not
guaranteed or warranteed and they are not intended to be nor
should they be understood to be representations or warranties
concerning the products described.
Trademarks
BiO2 and BioQuest are registered trademarks. Other brand and
product names may be trademarks or registered trademarks of
their respective companies.
BioQuest
4750 Longley Lane #202,
Reno, Nevada. 89502

SYSTEM COMPONENTS
The following drawings will help you become familiar with the
components that comprise BiO2 as well as how they function.
Wall Fitting: A specially designed fitting that allows BiO2
to draw water into the system, sanitize it and return it to
the spa.
Touch Control: This allows you to program BiO2 to the proper
level of sanitizing. See page 2 for detail.
Cell: This part of BiO2 draws water from the spa through
the specially designed Wall Fitting (see figure above) you can
see in your spa. The water passes over an electrode
(contained in the Cell), that electrolyzes the sodium bromide
and non-iodized tablesalt (sodium chloride) you will add to
your spa water. This electrolysis generates the powerful
sanitizing agents, oxygen and bromine. The water with
sanitizers re-enters the spa from the cell at about 3.7 litres
per minute through the wall fitting.
Power supply: This unit contains the BiO2 "brain",the
microprocessor that you set to work as hard as your spa usage
requires. It has no serviceable parts.
SYSTEM COMPONENTS
TOUCH PAD CONTROLS
TOUCH CONTROL BUTTONS
SET LEVEL:
Powers the unit on and permits you to set a maintenance level
of sanitizing. Press to adjust from levels 1-9. 0 is off.
BLAST:
Increases the production of sanitizers for heavy bather loads
and/or frequent spa use. Press BLAST to activate (turns off
after 6-12 hours) or press again to deactivate. BLAST must be
deactivated to adjust the Maintenance Level.
TOUCH CONTROL LOCKOUT:
Press and hold both SET LEVEL and BLAST buttons simultaneously
to lock or unlock the touch control. When an L appears in the

LED window release the buttons.
TOUCH CONTROL INDICATOR LIGHTS
LED WINDOW:
Shows the level of maintenance sanitizing. A service code will
be displayed in case of a problem. The letter Uwill appear to
indicate Usage Sense (activation of BiO2 when the jet pump is
on) if so equipped.
READY: When light is on: BiO2 has power.
CELL ON: When light is on: BiO2 is producing sanitizers.
CHECK SALT:
Flashing light: Salt level is high, test salt level and
adjust.
Steady light: Salt level is too low: add sodium bromide and
non-iodized table salt (sodium chloride). Please refer to page
(11) of this manual.
SERVICE: When light is on: check the LED window for a service
code. Contact dealer or BiO2 Help Desk 1-800-516-4028. Please
refer to page (8) of this manual.
OPERATING BiO2
With this basic understanding of the BiO2 Components and their
function, let=s discuss how to operate the unit.
STEP 1. GETTING STARTED
1. Drain your spa and start with fresh water. Follow your
dealer's recommendations for start up. Adjust the pH to
between 7.2 and 7.8.
2. Add sodium bromide and non-iodized table salt (sodium
chloride) to your spa water as follows. Add 58 grams of
sodium bromide (scheduled or registered, for use in spas,
under the Pest Control Products Act) and 454 grams of
non-iodized table salt (sodium chloride) for every 378.5
litres (83.3 imp gal) of water in your spa. This special
combination of sodium bromide and sodium chloride will
dissolve rapidly. Turning on the spa's jets will help
dissolve the sodium bromide and sodium chloride.

STEP 2.
ESTABLISHING AND TESTING THE BROMINE LEVEL
1. Add 58 grams of potassium monopersulphate (scheduled or
registered, for use in spas, under the Pest Control
Products Act). Turn on the spa jets to help dissolve the
potassium monopersulphate. After 10 minutes, test the
bromine level with the test kit provided in the Start
Kit. If the reading is 3 ppm or more, proceed to Step 3.
If not, add 58 grams of potassium monopersulphate. Take
another reading after 10 minutes.
If the bromine level is still below 3 ppm, simply press the
BLAST button. This will activate BiO2 for a period of 6 to 12
hours. Test for bromine again at completion. In some extreme
situations, you may need to press BLAST a second time to
achieve a minimum of 3 ppm bromine. You should achieve a 3-5
PPM bromine residual, which will put it in the range
recommended by NSPI (National Spa and Pool Institute) for safe
water.
During the BLAST cycle, a rotating bar will appear on the LED
display, and the "CELL ON" LED will be lit.
The BLAST cycle may be deactivated at any time by pressing the
BLAST button again.
Please note: It is common for the bromine level demand to be
high, initially. Test your bromine level daily for the first
week and adjust the maintenance level as required and/or press
the BLAST button.
OPERATING BiO2 (cont'd)
You may notice that the bromine level will fluctuate based on
the number of persons using the spa and how often the spa is
used. Check the bromine level weekly, to ensure the proper
level of 3-5 ppm. If it is low (less than 3 ppm), set a higher
Maintenance Level. If it is high (greater than 6 ppm), set a
lower Maintenance Level. Keep pH in range of 7.2 to 7.8. To
maintain an adequate bromine level (3-5 ppm), BiO2 must be
activated while you are in the spa. This can be done in one of
two ways. BiO2 units with Usage Sense (does not come on all

spas) will automatically start sanitizing when the spa jets
are turned on. The letter "U" will appear in the LED display.
BiO2 will continue to operate for 2 hours after the spa jets
have been turned off. This helps BiO2 recover from bather
usage. For units without Usage Sense, you simply press the
BLAST button as you enter the spa. It will activate BiO2 for a
6 to 12 hour period. In both cases, BiO2 will return to the
maintenance mode after operation is complete. It is not
recommended that your water=s bromine level exceed 6 PPM.
Please note: Excessive bromine levels (over 10 PPM) can cause
corrosion of metals within a spa, test your bromine level
regularly.
STEP 3.
CHOOSING THE MAINTENANCE LEVEL
The maintenance sanitizing level you set depends upon two
primary factors:
1) How much water the spa contains. The more water, the
harder BiO2 has to work.
2) The amount of use your spa will get. The more the spa is
used, the greater the number of contaminants enter the
water and the harder BiO2 has to work.
If your spa use is occasional or infrequent, you will find a
lower maintenance level to be adequate to maintain water
purity. We suggest starting with level 1.
*It is also recommended that you lower the maintenance level
if you will not be using your spa for two weeks or more. It
may take a few days to find the proper level of sanitation for
your spa and spa bathing habits. Be sure to test the water
with the bromine test kit. Remember, if you need any
assistance with this process call the BioQuest Help Desk at
1-800-516-4028.
3) With the "BLAST" cycle off, push the button marked SET
LEVEL to set the maintenance sanitation level. The "CELL
ON" LED should be illuminated and the level display
should read "1". This starts BiO2 at its lowest level. (A
"0" is the "power off" position. This indicates that the
BiO2 maintenance cycle has been deactivated).
OPERATING BiO2 (cont'd)

4) Continue to push the SET LEVEL button to program BiO2 to
the desired maintenance level. Sanitizing levels for BiO2
range from 1 (the lowest setting) to 9 (the highest
setting). We recommend starting with level 1. After the 9
the display loops back to 0, the Off position.
Please note: There is no need for the spa's system to be on
while you are adjusting BiO2. BiO2 works independently of the
spa's pump and jet system.
USAGE SENSE
Some models of BiO2 automatically activate when the spa's high
speed jet pump is on to sanitize the water while the spa is
being used. That is the time when water sanitation is most
needed. A letter Uwill appear in the LED window to indicate
that BiO2 has sensed spa usage and is activated. BiO2 will
remain in Usage Sense mode for 2 hours after spa use and then
will return to the Maintenance Mode.
If your BiO2 system is not equipped with "Usage Sense" simply
push the BLAST button as you enter the spa. This effectively
simulates Usage Sense.
OPERATING BiO2 (cont'd)
STEP 4.
PROTECTING YOUR TOUCH CONTROL SETTINGS
LOCKOUT FEATURE
LOCK Your BiO2 touch control pad can be locked to prevent
accidental tampering with the SET LEVEL or BLAST buttons. To
activate the Lock Out feature, press and hold both the SET
LEVEL and BLAST buttons simultaneously until an Lappears in
the LED window. Release both buttons while the L is displayed.
The L indicates that the Lock Out feature is now active.
UNLOCK To Aunlock@: the touch control pad, follow the same
procedure. Press and hold both the SET LEVEL and BLAST buttons
simultaneously until the Lreappears in the LED window.
Release both buttons while the Lis displayed. The Lock Out
feature is now deactivated.
REGULAR MAINTENANCE

TEST BROMINE WEEKLY
We recommend that you test the level of bromine in your water
at least weekly to ensure that you have an adequate residual
of bromine (3-5 PPM). Excessive levels of bromine (over 10
PPM) can cause corrosion.
BiO2 also produces oxygen as a powerful oxidizer to destroy
organics in the water. There is no test required for oxygen.
TEST pH WEEKLY
The pH (relative alkalinity or acidity) will tend to rise over
time and should be adjusted if pH climbs over 7.8. Any pH
lowering product may be used. High levels of bromine may
affect the pH indicator. If your test turns the water test
sample a purplish colour, check the bromine level and take a
water sample to your dealer.
TEST TOTAL ALKALINITY MONTHLY
Test strip kits are available that will indicate the
alkalinity of your spa water. Ask your spa dealer.
HARD WATER
If the water in your area is hard (high levels of calcium)
BiO2 may deposit some white flakes on the floor of the spa.
This is normal. BiO2 is actually removing hardness from the
spa water. This process can continue for a period of weeks or
months depending on the hardness level. An optional strainer
(calcium trap) will be available which attaches onto the wall
fitting. It will capture the scale which you can then
conveniently dispose of. If the water in your area is soft,
(below 120 PPM hardness as calcium carbonate) you will need to
add calcium to your water. Call your dealer or the BiO2
Consumer Help Desk for information.
REMOVING BiO2 FOR SERVICE
If you need to remove your BiO2 unit, Cover the BiO2 wall
fitting with plastic wrap and stretch a rubber band around the
wall fitting edge as shown by illustration. This is for
TEMPORARY USE ONLY. Remove the BiO2 unit from the wall fitting
tubing and apply the drain plugs to the tubing. Once the
servicing has been completed and the tubing reconnected to the
cell, the plastic wrap may be removed.

WINTERIZING
If you drain your spa for the winter, you should disconnect
the tubing from the cell, empty the cell of water completely
and store it indoors. The power to the spa (and BiO2) should
be shut off. Your spa should not be filled with water without
the heater set above freezing.
TROUBLESHOOTING
DIAGNOSTIC FEATURE
The BiO2 touch control pad will help troubleshoot the system
without the need to open the spa's equipment compartment. The
troubleshooting guide will ask you to check the diagnostics
for certain conditions as follows:
Press both the SET LEVEL and BLAST buttons simultaneously.
Keep both buttons pressed until a "t" appears, (see
illustration below) then release the buttons. A sequence of
letters and numbers will be displayed, one digit at a time,
that will indicate how the system is operating and the
potential trouble. The sequence will stop automatically after
2 cycles. For troubleshooting purposes, please write this
sequence down in order. You may be asked for them by your
dealer or the BioQuest Help Desk Technician.
DIAGNOSTIC READOUT SEQUENCE
CODE DESCRIPTION VALUE RANGE
Pc Motor current 0.4 to 0.7
Cc Cell current 0.9 to 3.0
Cu Cell voltage 13.0 TO 17.0
Read outs in these ranges indicate proper functioning.
TROUBLESHOOTING
CONDITIONS
My BiO2 unit is not working.....
1.) What does the water look like?
a. Cloudy: Possible low or no Bromine, or filtration

problem.
b. Green: Low Bromine (may also be extremely high
bromine)
2.) Has 58 grams sodium bromide and 454 grams non-iodized
table salt (sodium chloride) been added for every 378.5
litres (83.3 imp gal) of water in your spa?
3.) Have the two (58 grams) bags of potassium monopersulphate
been added to the spa?
4.) When you look at the BiO2 touch pad, what do you see?
a. A,C,F,J,P,=, or // are fault codes. Consult the Fault Code
Guide for further instruction.
5.) What is the Bromine Level?
a. The bromine level should be between 3 and 5 ppm.
b. Press the BLAST button if the bromine level is below
2.
6.) Check the diagnostics "t".
a. Press both buttons (SET LEVEL & BLAST) simultaneously
until a "t" is seen in the display window and immediately
release the buttons. The following sequence will appear:
"Pc (Motor Current) 0.4 to 0.7
"Cc (Cell Current) 0.9 to 3.0
"Cu (Cell Voltage) 13.0 to 17.0
This cycle will repeat 2 times.
b. If the current and voltages are half of what they
should be, and you have a 240 VAC BiO2 unit (201-XX-XX),
check the input power, it may be wired for 120 VAC
instead of 240 VAC.
7.) Is the BiO2 touch pad functioning when the spa jets are
in operation?
a. If not, it is possible that BiO2 is not wired for 24
hours continuous power.

b. Contact your dealer for proper wiring information.
c. Shut off the main breaker to the spa, wait for 30
seconds before resetting.
9.) Refer to No or Low Bromine residual. (See page 10)
The cell seems to be noisy....
1.) It is normal to be a bit noisy during the cleaning cycle.
If it is constant or persistent, the cell may need to be
replaced.
2.) Check diagnostics "t" to ensure motor current is between
0.4 to 0.7 Amps.
TROUBLESHOOTING
CONDITIONS (cont'd)
No or Low Bromine Residual.....
1.) Ensure that the Bromine test has been performed properly.
a. Test strips require a 1 second dip to read the pH and
Alkalinity levels, and then a second dip for 30 second to
read the Bromine level.
b. Liquid Test Kits (OTO, DPD) require a certain amount
of drops into their measuring vial.
c. It is possible that DPD may become bleached out if the
bromine level is extremely high.
2.) Check the Diagnostics "t".
a. Press both buttons (SET LEVEL & BLAST) simultaneously
until a "t" is seen in the display window and immediately
release buttons. You will see:
"Pc" (Motor Current) should be 0.4 to 0.7
"Cc" (Cell Current) should be 0.9 to 3.0
"Cu" (Cell Voltage) should be 13.0 to 17.0
This cycle will continue for 2 times.
3.) What is the Maintenance Level set at?

a. If less than 9, increase to the next Maintenance
Level.
b. If the Maintenance Level is set at 9 and BiO2 is
operating properly, call the BiO2 Help Desk to reprogram
your unit.
4.) Have the two 58 grams bags of potassium monopersulphate
been added to the spa?
5.) If the unit is not equipped with Usage Sense, is the
BLAST Button pressed upon entering the spa?
6.) Is the filtration cycle adequate?
a. Filtration Cycle should be at least 8 hours in a 24
hour period to ensure proper sanitation levels.
b. Is the spa filter clean?
7.) If BiO2 unit is equipped with Usage Sense, press the
BLAST button for a boost in the sanitizer level.
I can't adjust the display...
1.) Lockout function may be enabled.
a. To disable, press the SET LEVEL & BLAST buttons
simultaneously until an AAL@@ is seen in the display window.
Release the buttons, while the "L" is still displayed.
2.) Shut down power to the spa. Wait 30 seconds before
resetting.
3.) Touch pad may need to be replaced. Call BioQuest help
desk for further assistance.
TROUBLESHOOTING
CONDITIONS (cont'd)
All lights or no lights lit on the touch pad...
1.) Shut down main power to the spa. Wait 30 seconds before
resetting.
2.) Touch pad may be faulty. Call BioQuest help desk for

further assistance.
Water is leaking from the cell....
1.) Check connections for intake and outflow tubing.
Reposition over barbs. Tighten clamps on the barbs of the
wall fitting.
2.) If water is definitely coming from the cell itself, it
may need to be replaced.
There seems to be white flakes all over my spa....
1.) This is normal in hard water situations.
2.) BiO2 actually works to soften the spa water.
3.) Water should eventually become soft and this will stop.
4.) Due to the self cleaning feature of BiO2, during the
cleaning cycle (comes on for every 3 hours of operating
time) scale may be deposited into the spa water. Stain
and scale inhibitor may be used.
The Check Salt Light is on.....
1.) If it is steady -
a. The salt level is low, check with Salt Test Strips.
b. Sodium chloride level should be 1,200-1,500 ppm.
c. Add number of units where 1 unit equals 1 packet (58
grams) of sodium bromide (scheduled or registered, for
use in spas, under the Pest Control Products Act) and 454
grams of non-iodized table salt (sodium chloride)
according to chart below.
Spa Capacity in Litres (Imp Gal)Starti
ng
Salt
Concen
tratio
n
756 L
(166) 945 L
(207) 1134 L
(249) 1323 L
(290) 1512 L
(332) 1701 L
(373) 1890 L
(415)
300-2223344

350
450-
600 1222333
600-
750 1122223
750-
900 1111222
900-
1,100 1111112
2.) If it is flashing -
a. The salt level is high, check with Salt Test Strips.
b. Sodium chloride level should be 1,200-1,500 ppm.
c. Drain partially and refill with fresh water.
d. Recheck the sodium chloride level.
TROUBLESHOOTING
FAULT CODES (Flashing service light)
FAULT
CODE DESCRIPTION/RECOMMENDATIONS
JLow Cell Current
1. Check Cu (Cell Voltage) and Cc (Cell Current)
value in Diagnostics, "t"
2. If Cu is below 13 call for service. If Cu is 13
to 17 then check Cc.
3. If Cc is below 0.9...
a. Test salt level with Salt Test Strips. If salt
is below 1200 ppm...
b. Add sodium bromide and non-iodized table salt

(sodium chloride). See page 11.
c. Press BLAST and see if BiO2 remains on without
the service code reappearing .
d. 240 VAC BiO2 unit may be wired on a 120 VAC
circuit.
e. If Jcode reappears there is a possible
electrode failure. Call for service.
CLow Motor Current
1. Check for loose motor wire connections (red or
black) at the Cell.
a. Inspect and reconnect
b. Inspect connection at Power Supply and
reconnect.
c. Press BLAST. If "C" reappears.
2. Possible Air Lock in the Cell.
a. Use a garden hose to fill the cell at the wall
fitting discharge outlet to push air out of the
cell (Let water run at medium pressure for 30
seconds)
b. Press BLAST. If AAC@@ reappears call for service.
3. Cell cable may not be connected at the BiO2
Power Supply.
FVery Low Cell Current
1. Has sodium bromide and non-iodized table salt
(sodium chloride) been added to the water? If yes
2. Cell may not be receiving water. Make sure water
level covers the BiO2 wall fitting. If OK then
3. Possible air lock in the Cell.
a. Use a garden hose to fill the Cell at the wall
fitting discharge outlet to push air out of the
Cell. Let water run at medium pressure for 30

seconds.
4. A Cell wire may be disconnected.
a. Inspect the white and green Cell wire
connections and reconnect if needed.
5. Cell cable may not be connected at the BiO2
Power Supply.
AHigh Motor Current
Debris in cell or motor failure
a. Replace cell.
PLow Cell and Motor current
1. Priming problem
a. Use a garden hose to fill the Cell at the wall
fitting discharge outlet to push air out of the
Cell. Let water run at medium pressure for 30
seconds.
2. Cell wire disconnected
a. Check all wire connections to ensure that all
are tightly connected.
=4 hour limit for Usage Sense
1.) Denoted by two horizontal bars.
2.) The Usage Sense signal has been active for more
than 4 hours due to the booster being left on.
3.) Reset BiO2 by pressing the SET LEVEL and BLAST
buttons simultaneously until an "r" is seen in the
LED display window,
release buttons.
4.) Usage Sense is improperly wired (Call Dealer).
a. 120 VAC power supply connected to 240 VAC high
speed pump
b. Replace 120 VAC with a 240 VAC BiO2 Control Box.

/Touch pad disconnected
1.) Denoted by 3 horizontal bars.
2.) Shut off main power to spa and wait 30 seconds
before restarting.
a. Power up spa.
b. You may need to shut off power to the spa,
unplug and then reinsert touch pad to power supply.
reset power to the spa.
3.) Touch pad may need to be replaced. Call
BioQuest help desk for further assistance.
******************************
This label transcript service is offered by the Pest
Management Regulatory Agency to provide efficient searching
for label information. This service and this information do
not replace the official hard-copy label. The PMRA does not
provide any guarantee or assurance that the information
obtained through this service is accurate, current or correct,
and is therefore not liable for any loss resulting, directly
or indirectly, from reliance upon this service.
+))
This manual suits for next models
1
Table of contents
Popular Water Filtration System manuals by other brands

Tupperware
Tupperware Pure&Serve user manual

GE
GE PXRQ400T Owner's Manual & Installation Instructions

Schaffner
Schaffner ECOsine active FN3420-030-3 Series Operating and installation instructions

Anywire
Anywire ANF-01 Product guide

Mitsubishi Electric
Mitsubishi Electric PAC-TS70TB installation manual

Sears
Sears 625.345600 owner's manual