Step 1
+ USB interface
+ proven Masimo SETTM
performance
+ easy-to-operate
+ latest LiIon battery
technology
sat 801
Pulse Oximetry is special.
+ integrated
rubber boots
+ plethysmogram
for both channels
+ mains & battery
powered
Two-piece design includes a reusable AND a disposable sensor
Reusable+Disposable=ReSposable
for a Nationwide Newborn
Screening Standard to
improve detection of critical
congenital heart defects.
Also more and more in
the rest of the world, this
screening method becomes
mandatory.
What is Delta
Pulse Oximetry?
Delta Pulse Oximetry is the
unique method of obtaining
simultaneous differential Masimo
SET readings, derived by dual
channel pulse oximetry at
pre- and postductal spots.
This special conguration is well
suited for the easy implementati-
on of the Screening Protocol for
the systematic detection of Criti-
cal Congenital Heart Defects.
CCHD Screening
In the US, CCHD Screening is
based on the recommendation
of the U.S. Health & Human
Services that outlined a strategy
The sat 801Δhas been specifically designed for the
needs of Critical Congenital Heart Defect scree-
ning.
Combining the identical Gold Standard technology
for simultaneous dual channel readings minimizes
errors related to sequential readings and variations
caused by different pulse oximetry technologies.
Intuitive operation and a clear color-coded pre-
sentation provides reliable screening results in
seconds.
sat 801
Pulse Oximetry is simple.
sat 801 : Better Design
sat 801 : Increased Accuracy
sat 801 : Faster results
Delta (Δ) is the fourth
capital letter in the
Greek alphabet. It
is often used as a
difference operator
to describe change,
because delta is the in-
itial letter of the Greek
word „diaphorá“,
meaning „difference“.
Step 1
Preductal Spot (Right Hand)
Place sensor on the outer lateral aspect of the right hand.
Step 3
Obtain all three Readings at a time
Record both SpO2 - and the DELTA readings.
Step 2
Postductal Spot (Left or Right Foot)
Place sensor on the outer lateral aspect of either foot.
Step 4
Assessment
NEGATIVE Screen (Pass):
SpO2≥95% in hand or foot
AND DELTA (hand-foot difference) ≤3%.
POSITIVE CCHD Screening Test Result:
SpO2< 90% in hand OR foot,
OR
3 repeated positive screens (SpO290-94% in the hand AND foot
OR hand-foot absolute difference is > 3%)
Step 2
Step 3
LNC-1
connects to the sat 801Δ
Reusable sensors
offer cost-effectiveness and
environmental advantages
Disposable sensors
have the best performance,
greatest ease of use and
most comfort