1. Specifications
Construction: 16 AWG cold-rolled steel
Size: JPM406A-R3: 5.25"H (3U) x 17"W x 11.5"D (13.3 x 43.2 x 29.2 cm);
JPM418A-R2: 3.5"H (2U) x 17"W x 11"D (8.9 x 43.2 x 27.9 cm)
Weight: JPM406A-R3: 15.5 lb. (7 kg);
JPM418A-R2: 15 lb. (6.8 kg)
2. Overview
The JPM406A-R3 is 3U high, fits in a 19" or 23" rack, and supports 12 adapter panels. (Each adapter panel has
up to 12 connectors, for a maximum of 144 ports.) It provides termination for optical cables on the premises or
in a central office. The JPM418A-R2 is only 2U high and supports 6 adapter panels; it also fits in a 19" or 23"
rack. (Each adapter panel has up to 12 connectors, for a maximum of 72 ports.)
The Fiber Rackmount Cabinets are constructed of 16-gauge cold-rolled steel, and they’re compact and rugged
enough for commercial applications. Its powder coating finish is corrosion resistant.
The cabinet has front, back, and side access points for testing, removing, adding fiber, or replacing modular
adapters. The adapter panels mount on the adapter bracket from the front of the chassis.
Two cable-entry holes at the right and left on the cabinet’s rear and two patch cord exit holes in the front
bottom make cable installation easy.
The cabinet has a front door, a rear door, and outside and inside plant cable entry/exit holes. Up to 3 splice
trays (JPM440A, not included) can be mounted in the chassis. One splice tray accepts four fusion (for
single-mode fiber) or four mechanical (for multimode fiber) splice modules.
Your package should include the following items. If anything is missing or damaged, please contact Black Box
at 724-746-5500.
• (1) Fiber Rackmount Cabinet • (1) Kevlar®clamp (installed)
• (4) 12⁄24 cup-head screws • (4) 10⁄32 cup-head screws
• (30) 3" (7.6-cm) cable ties • (4) 4" (10.2-cm) cable ties
• (6) rectangular plastic cable holders • (3) black spool rings (installed) for JPM406A-R3 or
• (1) “danger” sticker (2) black spool rings (installed) for JPM418A-R2
• (1) locking PLEXIGLAS®door • (2) mounting brackets
• (4) silver screws for mounting • (1) set of keys
• (4) washers for mounting • (1) users’ manual
FIBER RACKMOUNT CABINET
3
3. Installation
1. Attach the two mounting brackets to the cabinet, and secure them with the four silver screws and four
washers.
2. Using the 10⁄32 or 12⁄24 cup-head screws, mount the Fiber Rackmount Cabinet in a 19" or 23" rack.
3. Open the back door by pulling, then releasing, the locking buttons.
4. Route multi-strand fiber cable (not included) through the rubber grommets on the cabinet’s top, bottom,
or side.
5. Use the Kevlar clamp to secure the multi-strand fiber to the cabinet. Loosen the Kevlar clamp’s two screws
and wrap the cable’s Kevlar yarn around the clamp. Tighten the screws to secure the multi-strand fiber to
the cabinet.
NOTE
The Kevlar clamp can be mounted on the cabinet’s rear left or right.
6. Install the cabinet’s PLEXIGLAS front door.
7. Pull out the tray (see Figure 1) to install a fiber adapter and splice tray (if needed). Up to 12 fiber adapters
can be installed in the JPM406A-R3; up to 6 can be installed in the JPM418A-R2.
8. Install the connectors on the multi-strand fiber cable, or make the splice as needed. (See Figure 2 for a
typical cable installation.) Connect the fiber cable to the fiber adapters.
9. Use the included rectangular plastic cable holders, cable ties, and black spool rings to hold the cable in
place inside the cabinet.
10. Slide the tray back into place inside the cabinet.
11. Close the cabinet’s rear door.
12. Snap in the 1" (2.5-cm) rectangular cable holder in the front of the inside tray. This helps organize the
fiber patch cables used in the front of the cabinet.
13. Close the cabinet’s front PLEXIGLAS door. Push the buttons in, then release, to lock.
14. Attach the “danger” sticker to the cabinet’s rear or top panel.
Figure 1. Fiber Rackmount Cabinet with tray pulled out.
Install the Kevlar
clamp on the side
Rectangular cable
holders
Inside
tray
Rubber grommets
Splice tray
Install the fiber
adapters here
1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746
© Copyright 2005. Black Box Corporation. All rights reserved.
Figure 2. Cabinet with three fiber adapter panels visible (up to nine more
can be stacked beneath the visible ones, for a total of 12 adapter panels).
The fiber cable is routed through the splice tray,
then terminated via the fiber optic connectors.
TRADEMARKS USED IN THIS MANUAL
Kevlar is a registered trademark of E.I. du Pont de Nemours and Company.
PLEXIGLAS is a registered trademark of Roehm GmbH & CO.
Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.
Fiber adapter panel
with 6 fiber optic
connectors
installed
Fiber optic cable
Fiber optic
connectors
Splice tray
(JPM440A, not
included)

This manual suits for next models

1

Other Black Box Enclosure manuals

Black Box RMT35X Series User manual

Black Box

Black Box RMT35X Series User manual

Black Box NEMA 12 User manual

Black Box

Black Box NEMA 12 User manual

Black Box RMT355A-R2 User manual

Black Box

Black Box RMT355A-R2 User manual

Black Box JPM397A User manual

Black Box

Black Box JPM397A User manual

Black Box SOHO JPM1110A User manual

Black Box

Black Box SOHO JPM1110A User manual

Black Box JPM402A-R3 User manual

Black Box

Black Box JPM402A-R3 User manual

Black Box JPM401A-R2 User manual

Black Box

Black Box JPM401A-R2 User manual

Black Box EWM12U242418-R2 User manual

Black Box

Black Box EWM12U242418-R2 User manual

Black Box Elite EWM12U242418-R3 User manual

Black Box

Black Box Elite EWM12U242418-R3 User manual

Black Box JPM440A User manual

Black Box

Black Box JPM440A User manual

Black Box 525068 User manual

Black Box

Black Box 525068 User manual

Black Box JPM406A-R5 User manual

Black Box

Black Box JPM406A-R5 User manual

Black Box USB 2.0 to SATA Enclosure User manual

Black Box

Black Box USB 2.0 to SATA Enclosure User manual

Black Box Elite EC38U3036 User manual

Black Box

Black Box Elite EC38U3036 User manual

Black Box RM2000A User manual

Black Box

Black Box RM2000A User manual

Black Box JPM399A User manual

Black Box

Black Box JPM399A User manual

Black Box ClimateCab RM1000A User manual

Black Box

Black Box ClimateCab RM1000A User manual

Black Box IE PowerTray 18-Slot AC User manual

Black Box

Black Box IE PowerTray 18-Slot AC User manual

Black Box JPM427A User manual

Black Box

Black Box JPM427A User manual

Black Box EC24U3032 User manual

Black Box

Black Box EC24U3032 User manual

Popular Enclosure manuals by other brands

Diablotek CPA-802 Specifications

Diablotek

Diablotek CPA-802 Specifications

Idis DA-JB2300 installation manual

Idis

Idis DA-JB2300 installation manual

Addonics Technologies DCED256ES user guide

Addonics Technologies

Addonics Technologies DCED256ES user guide

Armagard PDS 32 installation manual

Armagard

Armagard PDS 32 installation manual

StorCase Technology Data Express Ultra320 DE100 user guide

StorCase Technology

StorCase Technology Data Express Ultra320 DE100 user guide

Bosch AE20 installation guide

Bosch

Bosch AE20 installation guide

PROIETTA AF6 instruction manual

PROIETTA

PROIETTA AF6 instruction manual

Rosewill RX200R-APU3-25B user manual

Rosewill

Rosewill RX200R-APU3-25B user manual

Fractal FD-C-POA1A-01 user guide

Fractal

Fractal FD-C-POA1A-01 user guide

Rosewill RX30 User manual & installation guide

Rosewill

Rosewill RX30 User manual & installation guide

NEC 120Ef user guide

NEC

NEC 120Ef user guide

Rittal 9666.901 Assembly and operating instructions

Rittal

Rittal 9666.901 Assembly and operating instructions

Extron electronics HSA 822M user manual

Extron electronics

Extron electronics HSA 822M user manual

CRU Dataport RTX800-XJ quick start guide

CRU Dataport

CRU Dataport RTX800-XJ quick start guide

Fractal design FOCUS MINI user guide

Fractal design

Fractal design FOCUS MINI user guide

DeLOCK 42018 user manual

DeLOCK

DeLOCK 42018 user manual

OBERON 1020-00 installation guide

OBERON

OBERON 1020-00 installation guide

Renkforce 1887255 operating instructions

Renkforce

Renkforce 1887255 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.