INSTALLATION INSTRUCTIONS
ELECTRICAL CODES.
NOTE: INSTALLATION MUST MEET LOCAL PLUMBING AND
supplied.
5. Mount the control panel to control box using screws
46221-3 REV (A)
INSTALLATION INSTRUCTIONS
BUILT-IN ROUND FOOD WARMERS
MODELS SS-10ULT (TD, EUT, EUTD)
WELLS/BLOOMFIELD * VERDI, NV
ELECTRICAL
MODEL VOLTS WATTS AMPS PHASE WIRING TEMP.
FIELD
GAUGE RATING
SS-10ULT
SS-10ULT
SS-10ULT
SS-10ULTD
SS-10ULTD
SS-10ULTD 240
208
120
240
208
120 825
620
825
825
620
825
6.9
3.0
3.4
6.9
3.0
3.4 SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE 14 AWB Cu
14 AWB Cu
14 AWB Cu
14 AWB Cu
14 AWB Cu
14 AWB Cu 90°C
90°C
90°C
90°C
90°C
90°C
CUTOUT DETAILS PRODUCT DIMENSIONS
unit down to countertop (see detail at right).
wellslok flange and twist outward (clockwise) to tighten
4. From underneath, insert screwdriver into slots on
into front panel cutout.
3. Seat warmer onto countertop and the mount control box
panel cutout.
Pass control box through countertop cutout and front
2. Locate warmer and control box over countertop cutout.
to the underside of warmer flange.
to countertop, apply a bead of silicone adhesive/sealant
RECOMMENDATION: Before final seating of modular section
gasket is applied.
from the outside edge. Remove the paper backing as the
perimeter of the appliance mounting flange, about 1/4 inch
1. Press the self sticking 'gray' gasket material along the
Control Panel when installing.
IMPORTANT - DO NOT disconnect lead wires from the
TO INSTALL:
3. Cut out holes.
apron using the control box as a template.
2. Lay out and fabricate control panel holes in counter
apron.
1. Lay out "cutout" dimensions on countertop and front
TO FABRICATE:
the unit to avoid contact with elevated temperatures.
recommended that a baffle be placed 8 1/2 inches below
3. If storage is to be used underneath the unit, it is
2. Unit shall be accessible for servicing from the bottom.
and 8 inches to surface below the unit.
4 inches to front wall, 1 inch to back and side walls,
Wooden and Metal Installation: DO NOT install closer than
1. Required installation clearances:
OUTLINED BELOW UPON INSTALLATION:
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
CLEARANCES
BACK SIDE BOTTOM FRONT
(25)
1 1
(25) (203)
8
(102)
4
MINIMUM CLEARANCE REQUIRED
FROM UNIT TO THE NEAREST SURFACE
SS-10EUT 220-240 825 3.4 SINGLE 14 AWB Cu 90°C
90°C14 AWB CuSINGLE3.4825220-240SS-10EUTD