BC323 Series
Fibre video interfaces
Ref: 323 Series QSG issue 1.0_01/15
ThankyouforpurchasingthisBluebellOpticomprofessionalbroadcastvideoproduct.TheBC323Series
of interfaces are very simple to install and this Quick Start Guide should provide sufficient information to
get you up and running in the vast majority of cases.
Should you need additional information, an Operation Guide with full technical information is available
on request.
Quick Start Guide
BC323 Series Quick Start Guide V1.02
Optical Input 3G-SDI/HD-SDI/SDI/DVB-ASI
3G-SDI/HD-SDI/SDI/DVB-ASI
R
R
ed LED on for Signal Loss
ed LED on for Signal Loss
Range 4.5V - 17V DC
12V DC Input
Output
Input
Optical Output
Optical Output B 3G-SDI/HD-SDI/SDI/DVB-ASI
3G-SDI/HD-SDI/SDI/DVB-ASI
R
R
ed LED on for Signal Loss
ed LED on for Signal Loss
Range 4.5V - 17V DC
12V DC Input
Input A
Input B
Optical Output A
Optical Input B 3G-SDI/HD-SDI/SDI/DVB-ASI
3G-SDI/HD-SDI/SDI/DVB-ASI
R
R
ed LED on for Signal Loss
ed LED on for Signal Loss
Range 4.5V - 17V DC
12V DC Input
Output A
Output B
Optical Input A
BC323TR
BC323T BC323R
Overview:
The BC323 Series is a range of compact, stand-alone fibre interface modules intended for OB
applications, which allow SDI video to be transmitted over fibre-optic cable.
This Quick Start Guide covers three models comprising the range:
• BC323T dual channel transmitter – two independent channels, SDI inputs, dual fibre outputs
• BC323R dual channel receiver – two independent channels, dual fibre inputs, SDI outputs
• BC323TR single channel transceiver – one channel, dual fibre connector for transmit and receive,
plus SDI input and SDI output
The three models are of identical construction, and in outward appearance differ only in the silk-
screened labelling on the module:
BC323 Series Quick Start Guide V1.0 3
Power supply:
All BC323 models require an external power supply voltage between 4.5 and 17 V. A Bluebell Model
PS12 PSU (12 V) will be packed with the interface if one was ordered. The power supply connector is a
Neutrik®XLR4M, and a locking mating connector is pre-fitted to the PS12 DC cable.
Inputs and outputs:
Video:
BC323 interfaces are intended for use with serial digital video signals with data rates up to 3 Gb/s.
Standards supported are SD-SDI (SMPTE 259M-compliant), HD-SDI (SMPTE 292M-compliant) and
3G-SDI (SMPTE 424M-compliant); ASI baseband streams are also compatible.
Video inputs and outputs are on 75 ohm BNC sockets. All models have two connectors: inputs on the
BC323T and outputs on the BC323R; the BC323TR has one input and one output.
Optical:
A dual LC optical SFP connector is fitted as standard; each SDI channel uses one of the two optical fibre
ports. If specified at the time of ordering, ST optical connectors may be fitted instead.
Single-mode operation is standard; alternative multi-mode versions of each model are available. The
standard transmission wavelength for single-mode versions is 1310 nm; a dual-wavelength version
(1310 and 1510 nm) is also available. Multi-mode versions transmit at 850 nm. Transmitters fitted with
lasers tuned to specific CWDM wavelengths are also available. Any of the alternative options will have
been specified at the time of order.
Note that the optical receivers in the BC323R and BC323TR are wideband, and can be used with all
wavelengths in the range 1270 – 1610 nm.
Pin
10 V
2 n/c
3 n/c
4 +V DC
If using an alternative PSU,
wire the connector as above.
Model Power
BC323T 2.5 W
BC323R 2 W
BC323TR 2.5 W
Power consumption of the BC323 models.
BC323 Series Quick Start Guide V1.04
Contact details:
Bluebell Opticom Ltd.
Unit 2, The Quadrant
Howarth Road
Maidenhead
Berkshire
SL6 1AP
United Kingdom
Tel: +44 (0) 1628 510055
Fax: +44 (0) 1628 510057
Email: [email protected]
Web: www.bluebell.tv
Using the BC323:
Normally, BC323 units will be used in pairs, either with a BC323T and a BC323R at either ends of the
fibre run, or using a pair of BC323TR interfaces for bi-directional operation.
BC323T BC323R
DUAL FIBRE LINK
SDI CH 1 IN
SDI CH 1 IN
SDI CH 2 OUT
SDI CH 2 OUT
SDI CH 1 OUT
SDI CH 1 OUT
SDI CH 2 IN
SDI CH 2 IN
BC323TR BC323TR
DUAL FIBRE LINK
LEDs:
On all models, bi-colour LEDs are fitted adjacent to each of the BNC connectors. These illuminate green
to confirm a valid input signal, or red to indicate either no signal or a signal which is in some way invalid.
On a BC323T, the LEDs monitor the incoming SDI video signal (but see note re jumpers below), on a
BC323R, they confirm the receipt of a valid optical signal. The LEDs on a BC323TR monitor the video
input on the transmit channel and the optical input on the receive channel.
Reclocking:
The factory default is for the data at all the inputs (SDI or optical) to be internally reclocked. This will
generallybedesirablefor themajorityofoperationalsituations.Thereclockingcircuitrymaybebypassed
on a per-channel basis by moving internal PCB jumpers; this may be desirable when low data rates or
asynchronous operation are in use. Please consult the Operation Guide for details of how to do this.
SDI LED detection source:
Each transmission channel (i.e., two in the BC323T and one in the BC323TR) has an additional jumper
that sets the source signal for triggering the bi-colour LED. The default setting is for the LED to confirm
a valid SDI stream, but this may be altered to monitor the amplitude of the incoming signal, in which case
a red illumination indicates that the signal level is too low for data recovery to be made.

Other Bluebell Recording Equipment manuals

Bluebell BC160i User manual

Bluebell

Bluebell BC160i User manual

Bluebell BC363 User manual

Bluebell

Bluebell BC363 User manual

Bluebell BlueLite User manual

Bluebell

Bluebell BlueLite User manual

Bluebell BN328 Series User manual

Bluebell

Bluebell BN328 Series User manual

Bluebell BC313 Series User manual

Bluebell

Bluebell BC313 Series User manual

Bluebell BC364 User manual

Bluebell

Bluebell BC364 User manual

Bluebell BC860 User manual

Bluebell

Bluebell BC860 User manual

Bluebell BC625 User manual

Bluebell

Bluebell BC625 User manual

Popular Recording Equipment manuals by other brands

Cypress OSM-CPI product manual

Cypress

Cypress OSM-CPI product manual

Yamaha Audiogram 3 owner's manual

Yamaha

Yamaha Audiogram 3 owner's manual

HMS Ixxat PCIe/104 Series user manual

HMS

HMS Ixxat PCIe/104 Series user manual

Roland AR-3000 reference guide

Roland

Roland AR-3000 reference guide

Free The Tone FUTURE FACTORY owner's manual

Free The Tone

Free The Tone FUTURE FACTORY owner's manual

Alcorn Mcbride Pro Series user guide

Alcorn Mcbride

Alcorn Mcbride Pro Series user guide

dbx 160XT instruction manual

dbx

dbx 160XT instruction manual

MMB T2523 manual

MMB

MMB T2523 manual

IDEC HG2F-SS22VF manual

IDEC

IDEC HG2F-SS22VF manual

Crestron TPS-17G-QM/-L-IMC Operation guide

Crestron

Crestron TPS-17G-QM/-L-IMC Operation guide

Vip2 VK2-REC16HD user manual

Vip2

Vip2 VK2-REC16HD user manual

Yamaha MLA-200 owner's manual

Yamaha

Yamaha MLA-200 owner's manual

Peavey RMC 2000 operating guide

Peavey

Peavey RMC 2000 operating guide

DMX4ALL DMX-Audio Unit user manual

DMX4ALL

DMX4ALL DMX-Audio Unit user manual

ARX Audibox USB-DI VC owner's manual

ARX

ARX Audibox USB-DI VC owner's manual

Volvo Penta Easy Connect Interface installation instructions

Volvo Penta

Volvo Penta Easy Connect Interface installation instructions

genoQs Machines Octopus manual

genoQs Machines

genoQs Machines Octopus manual

Korg D16 Guide

Korg

Korg D16 Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.