1 . Positive metal core
2. Negative metal core
7-9mm
7-9mm
2
1
Crimping pliers
Press
MC4 Wrench
1 . Positive metal core
2. Negative metal core
1
2
1
3
56
2
4
L2 is 3mm longer than L1
L2=L1+3mm
L1
1 . Protective cover of AC junction box
2. M32 PG waterproof joint
1 . AC cable
2. Protective cover of AC junction
box
3. M4×12 screws
Screws Max 1.2 N.m
1. Terminal
2. M5 screws
3. 4mm2×5C cable
4. Junction box load symbol
Screws MAX 1.8 N.m
Screws
MAX 1.8 N.m
2
3
4
1
1
2
3
4
2
1
1
2
3
NOTE: It is forbidden to connect the grid cables to the
BACKUP interface of EP600.
3. Electrical connection
4. Power on 5. Service and contact
3.3 Connect the Grounding Cables 3.5 Connect the battery power cables
3.4 Connect the GRID and BACKUP cables 3.6 Connect PV cables
Conductor
cross-sectional
area:
2.5mm2~4mm2
PV1+:To solar panel positive
PV1-:To solar panel negative
PV1 PE:PV1 to solar panel
ground
PV2+:To solar panel positive
PV2-:To solar panel negative
PV2 PE:PV2 to solar panel
ground
NOTE: Please check the open circuit voltage of PV arrays,
which should be less than 500V.
Pay attention to the direction,
the direction of the arrow
towards the grid.
GRID-L1
GRID-L2
GRID-L3
NOTE:
1. The arrow inside the CT points to the grid.
2. Phase sequence: L1 to R, L2 to S, L3 to T.
3. The CT should be tied to the L1, L2 and L3 cables of the
main circuit breaker of the grid.
3.7 Attach the CT 3.9 Electrical connection mode 1: DC coupling 3.10 Electrical connection mode 2: AC coupling
3.8 Install the transfer switch
NOTE:
1.The neutral cable from the BACKUP teminal of EP600 cannot
be connected to the neutral cable of the public grid.
2.Connect the L1/L2/L3/N wires from EP600 BACKUP terminal
and public grid to the input side of the transfer switch, and the
output side to the essential loads.
3.If the grid is stable, turn to “II” to use the public grid to
power the loads; otherwise turn to “I” to use EP600 UPS
mode to avoid the inconvenience caused by power outage.
4.If EP600 ESS fails, turn to “II” and contact BLUETTI
Customer Support.
NOTE:
The meter is for EP600 ESS with grid-tied
PV inverter only.
1) Connect UA/UB/UC/UN cables to the
L1/L2/L3/N of PV inverter.
2) Connect the CT to the Meter and tie
them to L1/L2/L3 cables of the PV inverter.
3) Connect the 485-A red wire to pin 21,
485-B black wire to pin 22.
Step 1 Switch on the DC circuit breakers on EP600.
Step 2 Switch on the DC circuit breakers on B500 battery packs. Press and hold the power button of any
battery pack for about 3 seconds, and the green indicator on the button will light up.
Step 3 About 40 seconds later, the indicator on EP600 will stay green.
Step 4 Switch on the AC circuit breakers connected to the EP600 GRID terminal.
Step 5 Power on the system via BLUETTI app.
Step 6 Check the voltage of BACKUP terminal.
Step 7 Switch on the AC circuit breakers connected to the EP600 load port.
Step 8 Check the EP600 system operation in the App.
PV
B500
EP600
PV
BAT
Grid
Back-Up
IOT CT Grid
Non-essential
Load
Essential Load
LED Indicator
•Green: Run
•Orange: Alarm
•Red: Fault
States
No alarm and
No fault Always ON
Always ON Always ON
Always ON
/
/
//
/
/Always ON
Always ON
Alarm without
fault
No alarm with
fault
Alarm and
fault
Run
Green light
Alarm
Orange light
Fault
Red light
+
-
+
-On_Grid
Breaker
Transfer Switch
Main Breaker
QFQF
B500
Essential Loads
PV Input
BackupGrid
Bat Input
RCDRCD
EP600
RCD
CT
Non-essential
Loads
L1 L2 L3 N PE L1 L2 L3 N PE
1 5 9 13
2 10 14 4 8 12 166
4mm²
4mm²
4mm²
CT-3
CT-2
CT-1
L3
L2
L1
N
PE
L3
L2
L1
N
PE
L3
L2
L1
N
PE
Solar
PV User’s PV inverter Meter
(RS-485)
B500
(reserved)
EP600
CT Grid
Non-essential
Load
Essential Load
PV
BAT
Grid
Back-Up
IOT