manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bogen
  6. •
  7. Amplifier
  8. •
  9. Bogen Classic C35 Owner's manual

Bogen Classic C35 Owner's manual

The Bogen Classic Series Models C35, C60, and C100 are public address mixer amplifiers that
provide mixing of microphones, telephone, and auxiliary sources.
Output screw terminals are provided for 4-ohm (direct) and 8-ohm (C35 & C60 models only), 16-ohm,
25V and 70V (transformer-coupled) speaker systems. Output jacks let you connect to a tape
recorder or an additional booster amplifier, or feed a 600-ohm telephone line when an accessory
transformer (Model WMT1A) is used.
Classic Series
Public Address
Amplifiers
Models
C35, C60 & C100
• 3 models: 35, 60, and 100 watts
• 4 inputs: 1 MIC (Lo-Z), 1 AUX (Hi-Z), 1 TEL,
plus 1 selectable MIC or AUX
• Each input controlled by an independent
volume control
• Treble and bass controls
• AUX muting by external contact closure for
push-to-talk microphones
• TEL input for telephone paging applications
• TEL input voice-activated (VOX) mute over
AUX input
• Variable threshold for TEL input voice-
activated AUX mute
• Outputs for 4-ohm (direct), 8-ohm (C35 & C60
models only), and 16-ohm, 25V and 70V
speaker systems (transformer coupled)
• Output jack to connect a recording device
or booster amplifier
• Output jack to connect a general-purpose
600-ohm matching transformer (model WMT1A)
• Thermal protection and electronic shutdown
• Rack mountable with accessory mounting kit
(model RPK50)
• Listed to UL Standard 60065 for U.S. and Canada
Features
Description
Specifications subject to change without notice.
© 2002 Bogen Communications, Inc.
54-7853-01D 1109
Power Output (RMS): C35 C60 C100
Rated 35W 60W 100W
Frequency Response
& Distortion:
Transformer†70 Hz- 16 kHz (± 2 dB) @ 1% max.
4-Ohm Direct Output
20 Hz - 20 kHz (± 1 dB) @ 0.5% max
.
Hum and Noise:
MIC 55 dB below rated output
AUX 70 dB below rated output
TEL 70 dB below rated output
Input Sensitivity:
MIC Lo-Z Balanced 600μV
AUX 85mV
TEL 75mV
Outputs: 8 ohms (C35 & C60 models only),
16 ohms, 25V, 70V transformer-
isolated balanced or unbalanced;
4 ohms direct unbalanced
Output Connections: Screw terminal strip, TAPE/BOOSTER
jack; WMT1A jack (requires accessory
transformer)
Input Connections: Screw terminals for MIC and TEL, two
AUX Hi-Z jacks
Controls: MIC1, MIC2/AUX (switch selected),
AUX 2, BASS, TREBLE, TEL, VOX
Thermal Emissions:
C35: 119.5 BTU/hr.; C60: 228.8 BTU/hr.;
C100: 399.6 BTU/hr
.
Tone Control: Treble, ±11 dB @ 10 kHz;
Bass ±11 dB @ 100 Hz
Power Requirements: 120V AC, 60 Hz
C35: 85W; C60: 148W;
C100: 220W
Dimensions: 14-1/2" W x 3-3/4" H x 11" D
Product Weight: C35: 15 lb; C60: 17 lb; C100: 19 lb.
Technical Specifications
The public address amplifier shall be a Bogen Model
_________, or approved equivalent, with a full power rat-
ing of _______watts. (Specify: C35/35 watts, C60/60
watts or C100/100 watts.) The frequency response (trans-
former) shall be 70 Hz to 16 kHz ±2 dB†, with less than
1% distortion†. Input sensitivity shall be 600μV for low-
impedance balanced microphones, 85mV for auxiliary
inputs, and 75mV for TEL input. Hum and noise shall be
55 dB below rated output for the MIC inputs and 70 dB
below rated output for the AUX and TEL inputs.
The amplifier shall provide one dedicated low-impedance
balanced microphone input, one dedicated Hi-Z auxiliary
input, and one dedicated telephone line input, as well as a
fourth input that is switch selectable to be either a micro-
phone or auxiliary input.
The microphone inputs shall be equipped with filters to
protect against RF interference. Independent volume con-
trols for each input as well as TREBLE control (±11 dB @
10 kHz) and BASS control (±11 dB @ 100 Hz) shall be
incorporated. A precedence circuit shall mute the AUX 2
input when a customer-supplied external switch is actuated.
The amplifier shall include a TEL volume control to adjust
the telephone paging level and a VOX volume control to
adjust the TEL input signal level trigger point for automatic
muting of the AUX inputs.
The amplifier shall provide output impedances of
4-ohm (direct), 8-ohm (C35 & C60 models only), and
16-ohm speaker systems as well as for 25V and 70V con-
stant voltage systems. Two high-impedance outputs shall
be provided to drive a tape recorder or booster amplifier
and, when used with an accessory transformer (WMT1A),
to feed a 600-ohm telephone line.
The amplifier shall contain a resettable thermostat in the
power transformer to protect against heat build-up and
short-circuited or overloaded connections.
Provision shall be included to mount the amplifier in
19-inch equipment racks, using an optional rack panel kit
(Model RPK50). Dimensions shall be
14-1/2" W x 3-3/4" H x 11" D. Product weight shall be
______lb. (Insert 15 lb. for C35, 17 lb. for C60 or 19 lb.
for C100.)
Architect
and Engineer
Specifications
50 Spring Street, Ramsey, NJ 07446
201-934-8500 • Fax: 201-934-9832
www.bogen.com
†Measured @ 2 dB below FRP

Other manuals for Classic C35

1

This manual suits for next models

2

Other Bogen Amplifier manuals

Bogen C10C User manual

Bogen

Bogen C10C User manual

Bogen NQ-PA120 User manual

Bogen

Bogen NQ-PA120 User manual

Bogen Nyquist NQ-A2060 Instruction sheet

Bogen

Bogen Nyquist NQ-A2060 Instruction sheet

Bogen Classic C100 Guide

Bogen

Bogen Classic C100 Guide

Bogen TPU600-G2 Operating manual

Bogen

Bogen TPU600-G2 Operating manual

Bogen DPA-80 User manual

Bogen

Bogen DPA-80 User manual

Bogen HTA125A User manual

Bogen

Bogen HTA125A User manual

Bogen NQ-PA120 Instruction sheet

Bogen

Bogen NQ-PA120 Instruction sheet

Bogen WMA-80 Owner's manual

Bogen

Bogen WMA-80 Owner's manual

Bogen TPU-15A User manual

Bogen

Bogen TPU-15A User manual

Bogen M-Class M300 Guide

Bogen

Bogen M-Class M300 Guide

Bogen C10 Specification sheet

Bogen

Bogen C10 Specification sheet

Bogen Wall Mount Modular Amplifier WMA80 User manual

Bogen

Bogen Wall Mount Modular Amplifier WMA80 User manual

Bogen NYQUIST NQ-P0100 User manual

Bogen

Bogen NYQUIST NQ-P0100 User manual

Bogen HTA250A User manual

Bogen

Bogen HTA250A User manual

Bogen Challenger CHB10A User manual

Bogen

Bogen Challenger CHB10A User manual

Bogen NYQUIST NQ-P0100 User manual

Bogen

Bogen NYQUIST NQ-P0100 User manual

Bogen MX6A-T Installation instructions

Bogen

Bogen MX6A-T Installation instructions

Bogen TPU-35B User manual

Bogen

Bogen TPU-35B User manual

Bogen C35C User manual

Bogen

Bogen C35C User manual

Bogen HTA125A Instructions for use

Bogen

Bogen HTA125A Instructions for use

Bogen PM-3180 User manual

Bogen

Bogen PM-3180 User manual

Bogen BPA-60 User manual

Bogen

Bogen BPA-60 User manual

Bogen ProMatrix PM-3180 User manual

Bogen

Bogen ProMatrix PM-3180 User manual

Popular Amplifier manuals by other brands

McLelland MAP 1200HD Instruction book

McLelland

McLelland MAP 1200HD Instruction book

RFS 48960 Operation and installation manual

RFS

RFS 48960 Operation and installation manual

TJ Media TA-500 user manual

TJ Media

TJ Media TA-500 user manual

Sonos Connect AMP user manual

Sonos

Sonos Connect AMP user manual

Burson PC-160 user manual

Burson

Burson PC-160 user manual

Optimal Speaker Design BLACK A5500 owner's manual

Optimal Speaker Design

Optimal Speaker Design BLACK A5500 owner's manual

Yamaha AV-75PRO owner's manual

Yamaha

Yamaha AV-75PRO owner's manual

McIntosh 168255 owner's manual

McIntosh

McIntosh 168255 owner's manual

Extron electronics XPA 1002 user guide

Extron electronics

Extron electronics XPA 1002 user guide

DAPAudio HP-2100 manual

DAPAudio

DAPAudio HP-2100 manual

musikelectronic geithain RL-Amplifier 2 Instructions for installation and use

musikelectronic geithain

musikelectronic geithain RL-Amplifier 2 Instructions for installation and use

Ecler PAM1400 Service manual

Ecler

Ecler PAM1400 Service manual

Bellman & Symfon Bellman Audio Mino BE2030 manual

Bellman & Symfon

Bellman & Symfon Bellman Audio Mino BE2030 manual

Fishman PRESYS BLEND ONBOARD PREAMP user guide

Fishman

Fishman PRESYS BLEND ONBOARD PREAMP user guide

Linn WAKONDA owner's manual

Linn

Linn WAKONDA owner's manual

Honeywell X-DA1500EN user manual

Honeywell

Honeywell X-DA1500EN user manual

CYP CHDD-8C Operation manual

CYP

CYP CHDD-8C Operation manual

RM Italy HLA305V user manual

RM Italy

RM Italy HLA305V user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.