bonitron M3460 User manual

Model M3460
Ride-Thru
Enclosed Voltage Regulator
Customer Reference Manual

Bonitron, Inc.
2
Bonitron, Inc.
Nashville, TN
An industry leader in providing solutions for AC drives.
ABOUT BONITRON
Bonitron designs and manufactures quality industrial electronics that improve the reliability of
processes and variable frequency drives worldwide. With products in numerous industries, and
an educated and experienced team of engineers, Bonitron has seen thousands of products
engineered since 1962 and welcomes custom applications.
With engineering, production, and testing all in the same facility, Bonitron is able to ensure its
products are of the utmost quality and ready to be applied to your application.
The Bonitron engineering team has the background and expertise necessary to design, develop,
and manufacture the quality industrial electronic systems demanded in today’s market. A strong
academic background supported by continuing education is complemented by many years of
hands-on field experience. A clear advantage Bonitron has over many competitors is combined
on-site engineering labs and manufacturing facilities, which allows the engineering team to have
immediate access to testing and manufacturing. This not only saves time during prototype
development, but also is essential to providing only the highest quality products.
The sales and marketing teams work closely with engineering to provide up-to-date information
and provide remarkable customer support to make sure you receive the best solution for your
application. Thanks to this combination of quality products and superior customer support,
Bonitron has products installed in critical applications worldwide.

Bonitron, Inc.
3
AC DRIVE OPTIONS
In 1975, Bonitron began working with AC inverter drive specialists at synthetic fiber plants to
develop speed control systems that could be interfaced with their plant process computers. Ever
since, Bonitron has developed AC drive options that solve application issues associated with
modern AC variable frequency drives and aid in reducing drive faults. Below is a sampling of
Bonitron’s current product offering.
WORLD CLASS PRODUCTS
Undervoltage Solutions
Overvoltage Solutions
Uninterruptible Power for Drives
(DC Bus Ride-Thru)
Voltage Regulators
Chargers and Dischargers
Energy Storage
Braking Transistors
Braking Resistors
Transistor/Resistor Combo
Line Regeneration
Dynamic Braking for Servo Drives
Common Bus Solutions
Portable Maintenance Solutions
Single Phase Power Supplies
3-Phase Power Supplies
Common Bus Diodes
Capacitor Formers
Capacitor Testers
Power Quality Solutions
Green Solutions
12 and 18 Pulse Kits
Line Regeneration

Table of Contents
4
1. INTRODUCTION....................................................................................................................6
1.1. Who Should Use This Manual......................................................................................................7
1.2. Purpose and Scope........................................................................................................................ 7
1.3. Manual Revision...........................................................................................................................7
Figure 1-1: M3460R in E1 Chassis and M3460B in E2 Chassis..............................................................7
1.4. Symbol Conventions Used in this Manual and on Equipment.....................................................8
2. PRODUCT DESCRIPTION...................................................................................................9
2.1. Related Products and Documents.................................................................................................9
2.1.1. Products ............................................................................................................................................9
2.1.2. Documents ......................................................................................................................................10
2.2. Part Number Breakdown ............................................................................................................10
Figure 2-1: Example of Part Number Breakdown..................................................................................10
Table 2-1: System Voltage Rating Codes ..............................................................................................10
Table 2-2: Chassis Size Codes ...............................................................................................................11
2.3. General Specifications................................................................................................................11
Table 2-3: M3460R General Specifications...........................................................................................11
Table 2-4: M3460B General Specifications...........................................................................................11
2.4. General Precautions and Safety Warnings .................................................................................12
3. INSTALLATION INSTRUCTIONS ...................................................................................13
3.1. Environment ...............................................................................................................................13
3.2. Unpacking................................................................................................................................... 13
3.3. Mounting ....................................................................................................................................13
3.4. Wiring and User Connections..................................................................................................... 14
3.4.1. Power Wiring..................................................................................................................................14
Table 3-1: M3460R Power Wiring Connections....................................................................................14
Table 3-2: M3460B Power Wiring Connections....................................................................................14
3.4.2. Control Interface and I/O Wiring....................................................................................................16
Table 3-3: User I/O Connections with 3660I4 Board.............................................................................16
Figure 3-1: M3460R I/O Terminal connection ......................................................................................17
Figure 3-2: M3460B I/O Terminal connection ......................................................................................18
3.5. Typical Configurations...............................................................................................................20
Figure 3-2: M3460R Typical Configuration without Energy Storage....................................................20
Figure 3-3: M3460R Typical Configuration with Electrolytic Capacitor Storage Bank........................21
Figure 3-4: M3460R Typical Configuration with Ultracapacitor Storage Bank....................................22
Figure 3-5: M3460B Typical Configuration with Battery Storage Bank...............................................23
4. OPERATION .........................................................................................................................25
4.1. Functional Description ...............................................................................................................25
4.2. M3460R Operation for Full Outage Protection..........................................................................25
4.3. Operation Modes and Configuration..........................................................................................25
4.3.1. Normal Operation ...........................................................................................................................25
4.3.2. Test Mode .......................................................................................................................................25
4.8. DC Bus Threshold Voltage Setting ............................................................................................ 35
4.8.1. Determining the DC Bus Threshold Voltage Setting Directly (M3460R Models) .........................36
4.8.2. Determining the DC Bus Threshold Voltage Setting Directly (M3460B Models) .........................36
4.8.3. Determining the DC Bus Threshold Voltage Setting Using the Test Mode....................................36
4.8.4. Adjusting the DC Bus Threshold Voltage Setting ..........................................................................37
Figure 4-2: 3460C1 Control Board Layout ............................................................................................37
5. START-UP, MAINTENANCE AND TROUBLESHOOTING.........................................39
5.1. M3460R Start-up / Field Test Procedure....................................................................................39

Table of Contents
5
5.2. M3460B Start-up / Field Test Procedure....................................................................................40
5.3. Maintenance Items......................................................................................................................40
5.3.1. Capacitor Replacement Recommendations.....................................................................................40
5.3.2. Capacitor Testing Procedure...........................................................................................................42
5.3.3. Cleaning..........................................................................................................................................42
5.3.4. Fans.................................................................................................................................................42
5.3.5. Heatsinks.........................................................................................................................................42
5.4. Troubleshooting.......................................................................................................................... 43
Table 5-1: Troubleshooting Guide.........................................................................................................43
5.5. Technical Help –Before You Call .............................................................................................44
6. ENGINEERING DATA ........................................................................................................45
6.1. Ratings........................................................................................................................................45
Table 6-1: M3460 kW Ratings...............................................................................................................45
Table 6-2: Factory Setpoints for DC Bus Threshold and Test Boost Voltages......................................45
Table 6-3: M3460R Minimum Input Voltages.......................................................................................45
Table 6-4: M3460B Battery Bank Typical Values.................................................................................45
Table 6-5: M3460R Model Specifications for 230 –480 VAC Systems...............................................46
Table 6-6: M3460B Model Specifications for 230 –480 VAC Systems...............................................46
6.2. Efficiency / Power Consumption................................................................................................47
6.3. Branch Circuit Protection and Wire Sizing................................................................................47
Table 6-7: M3460R Input Power Wiring Sizes and Fusing ...................................................................47
Table 6-8: M3460B Input Power Wiring Sizes and Fusing ...................................................................47
6.4. Dimensions and Mechanical Drawings......................................................................................48
Figure 6-1: M3460-E1 Enclosure Dimensional Outline.........................................................................48
Figure 6-2: M3460-E2 Enclosure Dimensional Outline.........................................................................49
Figure 6-3: M3460-E3 Enclosure Dimensional Outline.........................................................................50
Figure 6-4: M3460-E4 Enclosure Dimensional Outline.........................................................................51
Figure 6-5: M3460-E5 Enclosure Dimensional Outline.........................................................................52
7. APPENDICES........................................................................................................................53
7.1. M3460 Installation Considerations.............................................................................................53
7.2. Specifying an Ultracapacitor Storage Bank for Full Outage Protection With M3460R Models 53
7.2.1. Energy Required for Outage ...........................................................................................................55
7.2.2. Minimum Capacitor Bank Voltage .................................................................................................55
7.2.3. Peak Current....................................................................................................................................55
7.2.4. Capacitor Specifications .................................................................................................................56
7.2.5. Minimum Series String...................................................................................................................56
7.2.6. Available Joules..............................................................................................................................56
7.3. Steering Diode Sharing with a Bonitron M3460 Ride-Thru.......................................................57
Figure 7-1: Diode Sharing Example.......................................................................................................59
7.4. Sag Only Installations & Circulating Currents...........................................................................60
Figure 7-2: M3460R Typical Configuration without Energy Storage....................................................60
Figure 7-3: M3460R Typical Configuration with Current Flow............................................................61
Figure 7-3: M3460R Typical Configuration with Current Flow with affected SCR Highlighted..........62
Figure 7-4: M3460R Typical Configuration with Ultracapacitor Storage Bank....................................63

D_M3460_D_CMAN_vall_00a 4/17/2020
6
This page intentionally left blank

D_M3460_D_CMAN_vall_00a 4/17/2020
7
1. INTRODUCTION
1.1. WHO SHOULD USE THIS MANUAL
This manual is intendedfor use by anyone who is responsible for integrating, installing,
maintaining, troubleshooting, or using this equipment with any AC drive system.
Please keep this manual for future reference.
1.2. PURPOSE AND SCOPE
This manual is a user’s guide for the model M3460 ride-thru voltage regulator. It will
provide the user with the necessary information to successfully install, integrate, and
use this in a variable frequency AC drive system.
In the event of any conflict between this document and any publication and/or
documentation related to the AC drive system, the latter shall have precedence.
1.3. MANUAL REVISION
The initial release of M3460 voltage regulator is Rev 00a.
Figure 1-1: M3460R in E1 Chassis and M3460B in E2 Chassis

D_M3460_D_CMAN_vall_00a 4/17/2020
8
1.4. SYMBOL CONVENTIONS USED IN THIS MANUAL AND ON EQUIPMENT
Earth Ground or Protective Earth
AC Voltage
DC Voltage
DANGER!
DANGER: Electrical hazard - Identifies a statement that indicates
a shock or electrocution hazard that must be avoided.
DANGER!
DANGER: Identifies information about practices or circumstances
that can lead to personal injury or death, property damage, or
economic loss.
CAUTION!
CAUTION: Identifies information about practices or circumstances
that can lead to property damage, or economic loss. Attentions
help you identify a potential hazard, avoid a hazard, and
recognize the consequences.
CAUTION!
CAUTION: Heat or burn hazard - Identifies a statement regarding
heat production or a burn hazard that should be avoided.

D_M3460_D_CMAN_vall_00a 4/17/2020
9
2. PRODUCT DESCRIPTION
Bonitron’s M3460 ride-thru voltage regulators provide protection from power quality events
for variable frequency drives (VFDs) that use a fixed rectifier and DC bus. The M3460R
provides sag protection for up to 2 seconds at 50% line sag on all 3 phases. It can also
provide protection from short term full outages of up to 2 seconds with the addition of
storage systems, such as capacitors. The M3460B, in conjunction with a battery bank,
provides full outage protection for up to 4 minutes at full power rating or 15 minutes at
50% power rating during a full outage.
Industries with continuous processes can suffer huge losses from equipment downtime,
loss of production, or damaged product when VFDs trip on under-voltage conditions.
Traditional UPS solutions are connected in series, which decreases the overall drive
system reliability. All Bonitron ride-thru products connect in parallel with the drive, thus
increasing system availability and reliability.
The M3460 regulates incoming voltage tothe DC bus of the variable frequency drive. This
allows the drive to “ride through” these events while maintaining motor speed and torque
without experiencing drive shutdown.
ADVANTAGES
•Reliability
•Parallel connection to AC system
•M3460 maintenance can be done while normal process is on-line
•Works with almost any fixed bus, variable frequency, PWM drive
•Only 2-3 parallel connections
•Can use existing AC feed wiring and breakers
•Instant response
•Bumpless transfer
•Easy commissioning
2.1. RELATED PRODUCTS AND DOCUMENTS
2.1.1. PRODUCTS
S3460UR SERIES RIDE-THRU SYSTEMS
Complete systems that use ultracapacitor storage for short term power
outages.
S3460BR SERIES RIDE-THRU SYSTEMS
Complete systems that use batteries for longer term power outages.
M3534 SERIES RIDE-THRU MODULES
Voltage regulators used for sag or outage protection of lower power systems.
M3528 BATTERY AND ULTRACAPACITOR CHARGERS
Chargers for high voltage storage strings.

D_M3460_D_CMAN_vall_00a 4/17/2020
10
2.1.2. DOCUMENTS
Please refer to the KIT 3660DD5 manual for more details about the DD5 Digital
Display. This manual is available at www.bonitron.com or by contacting
Bonitron.
2.2. PART NUMBER BREAKDOWN
Figure 2-1: Example of Part Number Breakdown
- - - -
D
Display
SystemVoltage Rating
Power Rating
Outage Duration
Chassis Size
M3460R
H
100
240
E1
Base Model Number
BASE MODEL NUMBER
The base model number for all ride-thru modules in this series rated for 2 second
operation is M3460R. The base model number for all ride-thru modules in this series
rated for 4-15 minute operation is M3460B.
SYSTEM VOLTAGE RATING
The M3460 is available in several input voltage ratings. This rating is indicated by a
code as shown in Table 2-1.
Table 2-1: System Voltage Rating Codes
RATING
CODE
NOMINAL VOLTAGE
(AC LINE /DRIVE BUS)
L
230 VAC / 325 VDC
E
380 - 415 VAC / 540 - 585 VDC
H
460 VAC / 650 VDC
POWER RATING
The power rating indicates the maximum power inkilowatts that can safely be handled
by the M3460 and is represented by a 3-digit value based on the nominal DC system
voltage rating and the maximum output current rating of the M3460. For instance, the
rating code for a 100kW M3460 is 100.
OUTAGE DURATION
The outage duration indicates the amount of time (in seconds) the M3460B module is
able to hold the DC bus at the threshold level while loaded to the rated current. This
duration is directly represented by a 3-digit value. For example, 240 in this position,
represents 240 seconds (4 minutes) of outage duration.
This code is omitted on M3460R models.
CHASSIS SIZE
five enclosed chassis sizes are indicated by a code as shown in Table 2-2. This
chassis size is determined by the current rating of the unit.

D_M3460_D_CMAN_vall_00a 4/17/2020
11
Table 2-2: Chassis Size Codes
CHASSIS SIZE CODE
DIMENSIONS (H X WX D)
3460R
3460B
E1
30.00” x 24.00” x 13.00
85-127 A
-
E2
36.00” x 24.00” x 13.00”
170 A
85 A
E3
40.00” x 24.00” x 13.00”
-
127-170A
E4
48.00” x 24.00” x 13.00”
255-425 A
-
E5
60.00” x 24.00” x 13.00”
-
255-340 A
DISPLAY
The M3460R and M3460B modules are equipped with the DD5 digital display.
2.3. GENERAL SPECIFICATIONS
Table 2-3: M3460R General Specifications
PARAMETER
SPECIFICATION
Input AC Voltage
208 –480 VAC
Input DC Voltage
200 –585 VDC
Output DC Voltage
265 –650 VDC
DC Bus Current Rating
85 –425 ADC
Power Rating
25 –250 kW
Inactive Power Consumption
<200W
Duty Cycle (Full Load)
1%
Sag/Outage Duration
2 seconds
Enclosure Rating
NEMA 1 Enclosure
Operating Temperature
0 to +40ºC
Storage Temperature
-20 to +65 ºC
Humidity
Below 90% non-condensing
Atmosphere
Free of corrosive gas and conductive dust
Table 2-4: M3460B General Specifications
PARAMETER
SPECIFICATION
Input DC Voltage
200 –540 VDC
Output DC Voltage
265 –650 VDC
DC Bus Current Rating
85–340 ADC
Power Rating
25 –200 kW
Inactive Power Consumption
<200W
Duty Cycle (Full Load)
1%
Sag/Outage Duration
4 minutes at full power or 15 minutes at 50% power
Enclosure Rating
NEMA 1 Enclosure
Operating Temperature
0 to +40ºC
Storage Temperature
-20 to+ 65 ºC
Humidity
Below 90% non-condensing
Atmosphere
Free of corrosive gas and conductive dust

D_M3460_D_CMAN_vall_00a 4/17/2020
12
2.4. GENERAL PRECAUTIONS AND SAFETY WARNINGS
DANGER!
•HIGH VOLTAGES MAY BE PRESENT!
•NEVER ATTEMPT TO OPERATE THIS PRODUCT WITH THE
ENCLOSURE COVER REMOVED!
•NEVER ATTEMPT TO SERVICE THIS PRODUCT WITHOUT FIRST
DISCONNECTING POWER TO AND FROM THE UNIT.
•ALWAYS ALLOW ADEQUATE TIME FOR RESIDUAL VOLTAGES TO
DRAIN BEFORE OPENING THE ENCLOSURE.
•FAILURE TO HEED THESE WARNINGS MAY RESULT IN
SERIOUS INJURY OR DEATH!
CAUTION!
•CERTAIN COMPONENTS WITHIN THIS PRODUCT MAY GET HOT
DURING OPERATION.
•ALWAYS ALLOW AMPLE TIME FOR THE UNIT TO COOL BEFORE
ATTEMPTING SERVICE ON THIS PRODUCT.
•INSTALLATION AND/OR REMOVAL OF THIS PRODUCT SHOULD
ONLY BE ACCOMPLISHED BY A QUALIFIED ELECTRICIAN IN
ACCORDANCE WITH NATIONAL ELECTRICAL CODE OR
EQUIVALENT REGULATIONS.
•BEFORE ATTEMPTING INSTALLATION OR REMOVAL OF
THIS PRODUCT ,BE SURE TO REVIEW ALL SY STEM
DOCUMENTATION FOR PE RTINENT SAFETY
PRECAUTIONS.
•NO USER-SERVICEABLE PARTS ARE CONTAINED
WITHIN THIS PRODUCT.INOPERABLE UNITS SHOU LD BE
REPLACED OR RETURNED FOR REPAIR.
•THIS PRODUCT DOES NOT PROVIDE MOTOR OVERLOAD
PROTECTION.
ANY QUESTIONS AS TO APPLICATION, INSTALLATION, OR SERVICE
SAFETY SHOULD BE DIRECTED TO THE EQUIPMENT SUPPLIER.

D_M3460_D_CMAN_vall_00a 4/17/2020
13
3. INSTALLATION INSTRUCTIONS
DANGER!
Installation and/or removal of this product should only be performed by a
qualified electrician in accordance with National Electrical Code or local
codes and regulations.
Proper installation of the M3460 ride-thru should be accomplished by following the steps
outlined below. Be sure to refer to the AC drive instruction manual as these steps are
performed. Please direct all installation inquiries that may arise during the installation and
startup of this product to the equipment supplier or system integrator. Please read this
manual completely before designing the drive system or enclosure layout to ensure all
required elements are included.
3.1. ENVIRONMENT
The installation site for M3460 should be chosen with several considerations in mind:
1. The unit has a NEMA 1 enclosure rating and will therefore require some protection
from the elements.
2. Conduit access for field wiring may be provided on the top-right surface of the
enclosure if desired.
3. The unit will require a minimum clearance of two (2) inches in all directions around
it when mounted near a non-heat source.
4. The mounting surface should be clean and dry.
The maximum ambient operating temperature of the M3460 should not exceed 40C.
Temperatures above this can cause overheating during operation.
The standby heat production of the M3460 is quite low, but can generate significant
heat during boosting. This is only of concern with the M3460B models because the
M3460R run time of 2 seconds will not allow the system to reach thermal equilibrium,
and should not cause thermal issues.
3.2. UNPACKING
Inspect the shipping crate and M3460 for damage.
Notify the shipping carrier if damage is found.
3.3. MOUNTING
Mounting dimensions can be found in Section 6.4.
Once the installation site has been selected as outlined above, the unit should be
mounted in place. The enclosure is provided with (4) 7/16” diameter mounting holes.
Mounting holes should be drilled and mounting studs or anchors installed before
positioning the enclosure. Mounting hardware is not supplied.

D_M3460_D_CMAN_vall_00a 4/17/2020
14
3.4. WIRING AND USER CONNECTIONS
Review this entire section before attempting to wire the M3460.
3.4.1. POWER WIRING
DANGER!
THE M3460CAN HAVE MULTIPLE POWER SOURCES,INCLUDING THE MAIN AC INPUT,
ENERGY STORAGE SYSTEMS AND THE DC CONNECTION TO THE VFD.
ENSURE THAT ALL SOURCES ARE DISCONNECTED AND LOCKED OUT BEFORE
ATTEMPTING SERVICE OR INSTALLATION.
FAILURE TO HEED THESE WARNINGS MAY RESULT IN SERIOUS INJURY
OR DEATH!
This section provides information pertaining to the field wiring connections of
the M3460. Actual connection points and terminal numbers of the AC drive
system will be found in the documentation provided with the drive system.
Be sure to review all pertinent AC drive system documentation as well as the
connection details listed below before proceeding.
Table 3-1: M3460R Power Wiring Connections
TERMINAL
DESIGNATION
FUNCTION
WIRING
SPECIFICATION
CONNECTION
TORQUE
AC Line
L1, L2, L3
AC Input
600 VAC
3/8" stud
150 lb-in
Storage Bus
+ -
DC Input
600 VAC
Existing
Diode / SCR
Check Device
Datasheet
Drive Bus
+ -
DC Output
600 VAC
3/8" stud
150 lb-in
Ground
600 VAC
5/16" stud
75 lb-in
Table 3-2: M3460B Power Wiring Connections
TERMINAL
DESIGNATION
FUNCTION
WIRING
SPECIFICATION
CONNECTION
TORQUE
Storage Bus
+ -
DC Input
600 VAC
3/8" stud
150 lb-in
Drive Bus
+ -
DC Output
600 VAC
3/8" stud
150 lb-in
Ground
600 VAC
5/16" stud
75 lb-in
Main power connections should be made with copper wire; use compression
fitting lugs. Wire sizing should be appropriate for the current being carried.
System ratings are listed in Section 6.1.
M3460 ride-thru units only provide full currents for a limited amount of time.
Therefore, wire heating is not as much a concern as mechanical strength.

D_M3460_D_CMAN_vall_00a 4/17/2020
15
3.4.1.1. AC LINE (L1, L2, L3) CONNECTIONS
The AC input to the M3460R can temporarily reach up to 200% of the
normal input current during a power quality event. Size the upstream
current protection devices accordingly, so that the incoming AC will not
be interrupted by the temporary power draw.
During a power quality event, the AC inputto the drive will not be drawing
current. Sizing the incoming AC feed to supply both the drive and the
M3460R simultaneously is not necessary. Even though the input current
during a power quality event may be higher than the normal input current,
this temporary overload is allowed by most codes without upsizing the
normal AC feed bus.
Due to the increasedcurrents in the ACfeed during apower quality event,
the total voltage drop of the incoming AC feed should be considered to
make sure the voltage doesn't dip too low.
If line chokes are to be used in the system, the M3460R must be installed
on the load side of these chokes. This minimizes the possibility of
circulating currents through the M3460R and converter section of the
VFD.
There is no needto connect theAC line to theM3460R if an ultracapacitor
bank is beingused. The DC connections from the ultracapacitor bank can
be made to any two of the AC line connections so that the existing fuses
can be used for protection. Please note that one terminal will not be
connected. See Figure 3-4.
3.4.1.2. STORAGE BUS (+ -) CONNECTIONS
If an electrolytic capacitor bank is used with the M3460R, the input can
be attached directly to the diode bus bars marked Storage Bus. External
fusing between the capacitor bank and the M3460R is recommended.
The M3460B battery bank connections are made at the Storage Bus fuse
blocks at the top of the module.
Make sure the polarity is correct for these connections, as failure to do
so can cause severe damage to the system.
DANGER!
FOR SYSTEMS THAT HAVE DC STORAGE,ALWAYS MEASURE DC VOLTAGES AND
FOLLOW PROPER PRECAUTIONS TO ENSURE THEY ARE AT SAFE LEVELS BEFORE
MAKING CONNECTIONS.
3.4.1.3. DRIVE BUS (+ -) CONNECTIONS
The M3460 must have a DC bus connection directly to the DC bus filter
capacitors within the drives. Connections cannot be made through the
braking terminals or with precharge resistors or DC link chokes between
the output of the M3460 and the DC bus capacitors in the drive. Consult
the manufacturers' documentation or contact Bonitron for further
assistance.
Make sure the polarity is correct for these connections, as failure to do
so can cause severe damage to the system.
DANGER!
FOR SYSTEMS THAT HAVE DC STORAGE,ALWAYS MEASURE DC VOLTAGES AND
FOLLOW PROPER PRECAUTIONS TO ENSURE THEY ARE AT SAFE LEVELS BEFORE
MAKING CONNECTIONS.

D_M3460_D_CMAN_vall_00a 4/17/2020
16
3.4.1.4. GROUNDING REQUIREMENTS
All units come equipped with a ground stud that is connected to the
module chassis. Ground the chassis in accordance with local codes.
Typically, the wire gauge will be the same as is used to ground the
attached drive.
3.4.2. CONTROL INTERFACE AND I/O WIRING
Control wiring allows for remote enabling, testing, and monitoring of the
M3460. All units are equipped with the 3660DD5 digital display interface,
all connections are made to the 3660I4 interface board.
Refer to the KIT 3660DD5 manual for operational and functional details.
.
3.4.2.1. CONNECTIONS WITH DD5 DIGITAL DISPLAY
Table 3-3: User I/O Connections with 3660I4 Board
3660I4
TERMINAL
FUNCTION
ELECTRICAL
SPECIFICATIONS
WIRE
AWG
TORQUE
USER INPUTS
TB15 - 1
24V Common
5 VDC, 25 mA
16
2.1 lb-in
TB15 - 2
Input Common
TB15 - 3
Spare
TB15- 4
Ride-Thru Test (RT Test) Input
TB15 - 5
Ride-Thru Enable (RT EN) Input
TB15 - 6
Charger Equalize (CH EQ) Input
TB15 - 7
Charger Enable (CH EN) Input
TB15 - 8
Courtesy 24V
USER OUTPUTS
TB14 - 1
Output Common
250 VDC, 120 mA
16
2.1 lb-in
TB14 - 2
Ride-Thru Active (RT ACTIVE) Output
TB14 - 3
Fault 2 (N.O.) Output
TB14 - 4
Fault 1 (N.O.) Output
TB14 - 5
Spare 1 (N.O.)
TB14 - 6
Spare 2 (N.O)

D_M3460_D_CMAN_vall_00a 4/17/2020
17
Figure 3-1: M3460R I/O Terminal connection
1 2 3 4 5 6 7 8 9
I/O CONNECTIONS
COURTESY 24V
RIDE THRU EN
RIDE THRU TEST
INPUT COM
COURTESY COM
FAULT 1
FAULT 2
RT ACTIVE
OUTPUT COM
TERMINAL
FUNCTION
TB –1
Courtesy + 24V
TB –2
Ride-Thru ENABLE
TB –3
Ride-ThrU TEST
TB –4
Input COM
TB –5
Courtesy COM
TB –6
Fault 1
TB –7
Fault 2
TB –8
Ride-Thru Active (RTA)
TB –9
Output COM

D_M3460_D_CMAN_vall_00a 4/17/2020
18
Figure 3-2: M3460B I/O Terminal connection
I/O CONNECTIONS
123456789
COURTESY 24V
RIDE THRU EN
RIDE THRU TEST
INPUT COM
COURTESY COM
FAULT 1
FAULT 2
RT ACTIVE
CHARGER ENABLE
10 11 12 13
CHARGER EQ
OUTPUT COM
STOR UV N.O.
STOR UV COM
L1
L2
L3 AC LINE
OUTPUT COM
CHARGING
READY
CH INPUT COM
EQUALIZE
ENABLE
14 15 16 17 18 19 20 21 22
CHARGER I/O
SIGNALS
TERMINAL
FUNCTION
TB –1
Courtesy + 24V
TB –2
Charger ENABLE
TB –3
Charger Equalize (EQ)
TB –4
Ride-Thru ENABLE
TB –5
Ride-Thru TEST
TB –6
Input COM
TB –7
Courtesy COM
TB –8
Fault 1
TB –9
Fault 2
TB –10
Ride-Thru Active (RTA)
TB –11
Output COM
TB –12
Storage Undervoltage (NO)
TB –13
Storage Undervoltage COM
TB –14
Charger READY signal
TB –15
Charger charginh signal
TB –16
Charger output com
TB –17
Charger enable signal
TB –18
Charger equalize signal
TB –19
Charger input com
TB –20
AC LINE L1
TB –21
AC LINE L2
TB –22
AC LINE L3

D_M3460_D_CMAN_vall_00a 4/17/2020
19
Figure 3-3: 3660I4 Board Layout
TB15
TB14
J3
TB3
TB7 61
TB9 61 81
INPUT COM
SPARE
RT OT
PCC
RTR
RTA
INPUT COM
DISCH OT
STORAGE OT
IMBALANCE
CH ACTIVE
CH FAULT
CH ENABLE
CH EQUALIZE
DISCHARGE
SPARE
OUTPUT COM
OUTPUT COM
RT ENABLE
RT TEST
TB11
+
-
TB8 TB6
1 1
1
TB5 TB1
TB4
2 3 4 1 2 3 4 1 2 3 4
TB2
13 L2 L1L3
+ - + -
TB13
4
1
-
+
68
1
1
TB12
4
1
COURTESY 24V
CH ENABLE
CH EQUALIZE
RT ENABLE
RT TEST
SPARE
INPUT COM
24V COM
SPARE 1 N.O.
SPARE 2 N.O.
FAULT 1 N.O.
FAULT 2 N.O.
RT ACTIVE
OUTPUT COM
RT BYPASS
RT NORMAL
CH BYPASS
CH NORMAL
DISCH BYPASS
DISCH NORMAL
SPARE 1
SPARE 2
TB16

D_M3460_D_CMAN_vall_00a 4/17/2020
20
3.5. TYPICAL CONFIGURATIONS
Figure 3-2: M3460R Typical Configuration without Energy Storage
FROM THE SAME FEED TRANSFORMER.
CONNECTED DOWNSTREAM.
2. IF LINE CHOKES ARE USED, RIDE-THRU MUST BE
1. INVERTER AND RIDE-THRU SHOULD BE POWERED
~NOTES~
CHOPPER
BRAKING
INTERNAL
VFD
INVERTER
BRAKING
RESISTOR
DISCONNECT
DRIVE
FEED
AC
CHOKES
LINE
GROUND
FAULT
SENSING
DISCONNECT
RIDE-THRU
M3460R
CHOPPER
+
-
+
-
DRIVE
BUS
STORAGE BUS
STORAGE BUS
Other manuals for M3460
1
Table of contents
Other bonitron Controllers manuals
Popular Controllers manuals by other brands

K-Rain
K-Rain PRO EX 2.0 instruction manual

AutomationDirect
AutomationDirect DirectLogic Series Application note

Timeguard
Timeguard ELU56 Installation & operating instructions

BZB Gear
BZB Gear BG-VOP-CB user manual

Delta
Delta AX Series instruction manual

WindowMaster
WindowMaster WMX 523 Installation instructions manual