RE 92105-01-X-B2/2019.08.06, BoschRexrothAG
5Axial piston variable pump | A4CSG Series 30
Operating data monitoring – X parameters
Operating data monitoring – X parameters
Safety instructions
Temperature class T3–T1
ATEX category II 3G Ex h IIC T3–T1 Gc X
To observe the maximum leakage temperature of 90 °C,
at least one of the following measures must be taken and
checked regularly:
▶ Check the leakage temperature atport TorR(L)
(maximum distance 30cm)
▶ Check the maximum inlet temperature of60°C atthe
suction port
▶ Check a maximum inlet temperature that must
bedetermined for the following operating points when
commissioning:
– Maximum working pressure and maximum
possible flow
– Maximum working pressure and minimum flow
Also monitor the reservoir level. Take appropriate action
ifthe temperature exceeds limits.
When the minimum boost pressure of8bar isnot
reached, switch off the system immediately.
ATEX category II 2G Ex h IIC T3–T1 Gb X
To observe the maximum leakage temperature of90°C,
the following measures must betaken:
▶ Install the supplied temperature sensor onthe unit
according tothe specifications inchapter 7.4.9 ofthe
instruction manual.
▶ Continuously monitor the leakage temperature ofeach
pump with atemperature sensor onports TorR(L)
(maximum distance toport 30cm).
▶ Connect both temperature sensors with a switching-off
for the system atthe limit temperature of90°C.
▶ This shut-off function should betested during
commissioning; see Chapter 8.1.1 ofthe instruction
manual.
▶ Reservoir level monitoring isalso required.
When the minimum boost pressure of8bar isnot
reached, switch off the system immediately.
Operating conditions for T3 and T4
Size T3 T4
250 ● ●
355 ● ●
500 ● ●
500...-S2145 ●●1)
Safety instructions
Temperature class T4
The size500...–S2145 isapproved just up to 3bar case
pressure for temperature classT4.
ATEX category II 3G Ex h IIC T4 Gc X
To observe the maximum leakage temperature of 80 °C,
at least one of the following measures must be taken and
checked regularly:
▶ Check the leakage temperature atport TorR(L)
(maximum distance 30cm)
▶ Check the maximum inlet temperature of50°C atthe
suction port
▶ Check a maximum inlet temperature that must
bedetermined for the following operating points
when commissioning:
– Maximum working pressure and maximum
possible flow
– Maximum working pressure and minimum flow
Also monitor the reservoir level. Take appropriate action
ifthe temperature exceeds limits.
When the minimum boost pressure of8bar isnot
reached, switch off the system immediately.
ATEX category II 2G Ex h IIC T4 Gb X
To observe the maximum leakage temperature of80°C,
the following measures must betaken:
▶ Install the supplied temperature sensor onthe unit
according tothe specifications inchapter 7.4.9 ofthe
instruction manual.
▶ Continuously monitor the leakage temperature ofeach
pump with atemperature sensor onports TorR(L)
(maximum distance toport 30cm).
▶ Connect both temperature sensors with a switching-off
for the system atthe limit temperature of80°C.
▶ This shut-off function should betested during
commissioning; see Chapter 8.1.1 ofthe instruction
manual.
▶ Reservoir level monitoring isalso required.
When the minimum boost pressure of8bar isnot
reached, switch off the system immediately.
1) Just up to maximum 3bar case pressure