3
Dear customer, first of all, thank you for you bought our product. It is advised for you to read the instruction book to
make a trial with the aim of understanding how the device work and then getting experience. This is a scientific and
electronic device and all the instructions in the book should be obeyed.
We wish success for your work.
ATTENTION! READ IT BEFORE USING THE PRODUCTS.
Information in this instruction book can be changed without your being known before.
This instruction book can't be copied, distributed or duplicated without BR SYSTEMS Detector’s permission,
it is certainly illegal.
General Information
BR 700 PRO products should also be used carefully like other electronic devices. Searching probs, main unit and
searching cable should be taken care they should be protected against hard substances and excessive force
shouldn't be applied to sockets
External influences
When BR 700 PRO products are worked in a normal way they do not cause any health problems or injuries.
BR 700 PRO do not generally become a threat to human body. It should kept away from children like electronic devices.
Be careful that all the precautions are taken against all kinds of risks. Do not use your device when it is under rain or
when the floor is extremely wet.
After being sure that probs are in soil and cable clipses are well plugged, tur on the device. When device is on probs
should never touch each other and should not be touched. More than the middle level of probs should be in soil.
Before the searching, be sure that the main unit battery is fully charged. Insufficient battery level may cause you to be
mistaken. Cleaning the probs with a wet cloth at the end of searching is advised.
ATTENTION! THERE IS 110 V POWER IN THE SEARCHING PROBS. DURING THE
SEARCHING AND WHEN CABLES ARE CONNECTED, DO NOT TOUCH THE SEARCHING
PROBS.

4
STARTING MEASUREMENT AND WATER DETECTION
Before starting measurement;
Check if the battery is fully charged. Get prepared beforehand according to search style ( square), on the field where you
want to search for probs.
Square working style
Be sure that cables clipses are fully and accurately plugged. Before you start work, if your working space is too dry soil,
make the ground where probs will be in slightly wet.
Tools required for work: rubber gloves to be protected from electric shock, hammer for the probs to be soil, cable pliers
to get probs from the soil, screwdriver for changing fuse, White towel to be protected from sunlight, metre to measure
location and length of electrodes. These tools will be helpful for your work.

5
1.1 Starting Meausurement and Searching water
Set the depth between each prob as double according to how many metres deep you want to search probs for
measurement. For example,
As an example in the photo ; there is 200 metres distance between each prob for water detection in 100 metres deep.
Cables length between probes and device should be 200 metres.
As in the Picture above, estimated depth of each prob should be its double. More than half part of probs should be in soil.
TURN the device on via ON / OFF button
There will be language selection menu on the main screen. Select device usage language on this menu, press on OK
button.
Language Selection Menu.

6

7
After language is selected device search screen will appear. You can select AUTOMATIC or MANUAL options in this
searching screen.
On device search screen, battery indicator is on the top left corner. Before starting
search you should be sure of your battery fully charged. If the indicator is % 20 or
less ,then maybe you get wrong readings.
1.2 AUTOMATIC SEARCH
Press on OK button which is on AUTOMATIC search on the screen. There are 6 times of measurement between 4 probs
The order is as below;
1 to 2 numbered probs,
2 to 3 numbered probs,
3 to 4 numbered probs,
1 to 4 numbered probs,
1 to 3 numbered probs,
2 to 4 numbered probs,
Searching between 2 ve 4 numbered probs, the result is written on the screen. In whichever probs are searched, led lamps
belonging to those probs on the device light. At the same device screen it is written which probs are searched. Please see
the pictures below.
After the automatic search between
all the probs finishes, measurement
results and depth detail are written
on the result screen.
Line : Lines where there are measurement
Depth : If water has been detected in the measurement average depth is written. If no
water is detected, NO WATER is written.
Result : According to measurement result quality of water detected between probs is
written. If water is not detected NO WATER is written.
When there is a disconnection of cables between probs and cables given together with the product, NO CONNECT is
written on device searching screen.

8
1.2 MANUAL SEARCHING
Press on OK button which is on MANUAL searching option on the screen. Press on OK button when you want
a measure. Measure will start in probs you have selected. In whichever probs there is a searching, led lamps belonging
to probs light on device. At the same device screen which probs are searched is written. Please see the pictures below.
1 and 2 numbered line has been
selected in manual search.
Details in the measurement are written
in manual searching detail page.
It is also written NO WATER on automatic searching as well as on manual one. If water has been detected, according to
water quality detail pages are written. According to water quality SALTY, MINERAL and FRESH are seperated. In
addition, on condition that there is a problem with manual searching detail page in the deepness links, it is written NOT
CONNECT.

9
THE EFFECTS OF WEATHER CONDITIONS AND FIELD CONDITIONS
1 - The device is produced for tough environmental conditions. However you shouldn't forget that your detector is a
sensitive electronic device. Don't be aware of using all features of your detector, but use it with care and protection.
2 - You must protect your detector from extreme cold and hot temperatures. For example don't leave it outside under
sun at hot summer days or in your car's trunk for a long time. Also don't leave it outside at cold winter days.
3 - Don't leave it under rain and at places with high moisture.
4 - Your detector must remain clean at all times. Clean the detector after every use. Don't use a too wet cloth etc. for
this.
5 - If you are not going to use your detector for a month or longer, take out its battery from the battery box, don't
leave it in the device.
TRANSPORTATION OF THE DETECTOR:
Your detector is an electronic device and the following must be paid attention about its transportation.
1 - Place the separable parts in the detectors hardcase or own package while transportation. Don't carry the parts
randomly in a bag or box etc. where they can harm each other or break.
2 - Be careful about not hitting anywhere or dropping the detector on the floor during transportation.
3 - Even the detector is in its the waterproof hardcase or package, don't leave it out at rain, snow or under sun.
4 - Especially if it's transported by a land vehicle, it must not be left under the sun even in the vehicle.
5 - While sending by cargo etc. it is best for the parts to be in their original packages, or if not possible, packaged
properly.
Maintenance
All repairing expenses stemming from technical problems are for free from the day you buy for 2 years.
Apply for your salesman for product service or for your questions. Main unit is analysed by a qualified
technician and if needed it is fixed. After 2 years all repairing expenses will be paid .
Provided that if you don't open the box or damage the product, then you will lose guarantee.
Your product being installed is delivered to you. Main unit under the delivery coverage, charger, 4 pieces of searching
probs and 4 pieces of search cables are given.

10
Table of contents
Other BR Security Sensor manuals
Popular Security Sensor manuals by other brands

BW Technologies
BW Technologies GasAlert Extreme user manual

hager
hager TX510 User instructions

Leuze lumiflex
Leuze lumiflex COMPACT EX2 Supplement for Connecting and Operating Instruction COMPACT

Pilz
Pilz PSEN ma1.3n-20 operating manual

Cerberus
Cerberus PYROTRONICS MSI-MB6 Installation and programming instructions

GEZE
GEZE GC 173 Supplementary sheet