manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Leviton
  6. •
  7. Security Sensor
  8. •
  9. Leviton decora IPV02 User manual

Leviton decora IPV02 User manual

WARNINGS AND CAUTIONS:
• Ifyouarenotsureaboutanypartoftheseinstructions,consultanelectrician.
• Cleanoutersurfacegentlywithdampclothonly.DO NOT usesoapsorcleaningliquids.
• Nouserserviceablecomponents.DO NOT attempttoserviceorrepair.
• UsethisdeviceWITH COPPER OR COPPER CLAD WIRE ONLY.
WARNINGS AND CAUTIONS:
• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE
POWER IS OFF BEFORE WIRING!
• Tobeinstalledand/orusedinaccordancewithelectricalcodesandregulations.
• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,DO NOTinstalltocontrolareceptacle.
• DO NOT controlaloadinexcessofspeciedratingsoryoumaydamageproperty,orcauseinjuryordeath.
RESET
RESET
TEST
TEST
1 2
0 3
Push down tabs per
diagram, one at a time and
rotate forward to release
1 2
0 3
1 2
0 3
Attach new face by inserting
bottom hinge tabs, then pivot
and snap the color kit to attach
Tools needed to install your Device
Changing the color of your device
Slotted/PhillipsScrewdriver ElectricalTape Pliers
Pencil   Cutters  Ruler
√
INSTALLING YOUR DEVICE
NOTE: UsecheckboxeswhenStepsarecompleted.
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
Step 1 WARNING:TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWERatcircuitbreakerorfuseandtest
thatpowerisoffbeforewiring!
2
4
3
1
Single-Pole
1. Line(Hot)
2. Neutral
3. Ground
4. Load
Step 2 Identifying your wiring application
(most common):
NOTE:Ifthewiringinthewallbox
doesnotresembleanyofthese
congurations,consultanelectrician.
WIRING SENSOR:
Connect wires per WIRING DIAGRAM as follows:
NOTE: Agroundconnectionisrequiredtooperate.Usethegroundwire
intheelectricalboxforgroundconnection.Ifthereisnogroundwire,
makesuretheelectricalboxisgroundedandattachthegroundwireto
theboxwithascrew.
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• LineHotwallboxwiretoterminalscrewmarked"BK".
• Loadwallboxwiretoterminalscrewmarked"RD".
• ProceedtoStep5.
Hot (Black)
Neutral (White)
Red
Black
Black
White
LOAD
Line
120VAC, 60 Hz
Sensor
Green
Ground
BK
RD
Terminal
Screw marked
Red (RD)
2
Terminal
Screw marked
Black (BK)
4
1
3
Single Pole Wiring Application:
Step 4
Single Pole Wide View Motion Activated Light Control
Cat. No. IPS02, IPV02 - INDOOR USE ONLY
Ratings:120VAC,60Hz-300WIncandescent-150WLED,CFL-200VAELV,MLV-Fluorescent2.5A-Resistive-1/6thHP
INSTALLATION INSTRUCTIONS
PK-93020-10-00-2A
FEATURES
• Cat.No.IPS02andIPV02haveasensingareaofcoverageof30ft.x
30ft.,andasensingangleof180
O
(seeSensingAreaCoveragegure
onpage2)
• Adjustablelightandtime-delaycontrolsarelocatedonthefrontofthe
device.Seeadjustmentsettingsectiononpage2fordetails.
• LEDindicatorisusedtoalerttheuserofthestatusofthedevice.
• AdjustableTimeDelaysettingfor30seconds,5minutes,
15minutesand30minutes.
• Occupancysensorscanbeconvertedtovacancysensors.
See Adjustment Section page 2.
LOCATION / MOUNTING
Thedevicerespondstotemperaturechangesandcareshouldbetaken
whenmountingthedevice.DO NOTmountdirectlyaboveaheatsource,
inalocationwherehotorcolddraftswillblowdirectlyonthesensor,or
whereunintendedmotion(e.g.,hallwaytrafc)willbewithinsensor’s
eld-of-view.
Preparing and connecting wires:
Thisdevicecanbewiredusingsidewireterminalscrews.
Chooseappropriatewirestrippingspecicationsaccordingly.
Strip Gage
(measure bare wire
here or use gage on
back of the sensor)
5/8”
(1.6 cm)
Cut
(if necessary)
Side Wire Connection
Sidewireterminalsaccept#14-12
AWGsolid copper wire only.
Step 3
Back Wire
Backwireopeningsuse#14-12
AWGsolid copper wire only.
BK
RD
YL 3-Way
Yourdevicemayincludecoloroptions.Tochangecoloroftheface
proceedasfollows:
• Makesurethattheendsofthewiresfromthewallboxarestraight
(cut if necessary).
• Removeinsulationfromeachwireinthewallboxasshown.

LIMITED5YEARWARRANTYANDEXCLUSIONS
Levitonwarrantstothe originalconsumerpurchaserand notforthe benetof anyone
else that this product at the time of its sale by Leviton is free of defects in materials
and workmanship under normal and proper use for five years from the purchase
date. Leviton’s only obligation is to correct such defects by repair or replacement, at
itsoption, ifwithin suchveyearperiod theproduct isreturnedprepaid, withproof of
purchasedate, anda descriptionoftheproblemtoLeviton Manufacturing Co., Inc.,
Att: Quality Assurance Department, 201 North Service Road, Melville, New York
11747.Thiswarrantyexcludesandthere isdisclaimed liabilityforlaborforremovalof
thisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperly
orinanimproperenvironment,overloaded,misused,opened,abused,oralteredinany
manner,orisnotusedundernormaloperatingconditionsornotinaccordancewithany
labelsorinstructions.There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose,but ifany impliedwarranty is
requiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,including
merchantabilityandtnessforaparticularpurpose,islimitedtoveyears.Leviton is not
liable for incidental, indirect, special, or consequential damages, including without
limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay
or failure to perform this warranty obligation.Theremediesprovidedhereinarethe
exclusive remedies under this warranty, whether based on contract, tort or otherwise.
PK-93020-10-00-2A©2012LevitonMfg.Co.,Inc.
• Positionallwirestoprovideroomin
outletwallboxfordevice.
• Ensurethattheword"TOP"is
facingupondevicestrap.
• Partiallyscrewinmountingscrews
inwallboxmountingholes.
• Restorepoweratcircuitbreakerorfuse.
• Wait40secondsforsensortopowerup.
• ForIPS02,lightswillautomaticallyturnON
afterpowerisapplied.
• ForIPV02,presspushpad.Lightsshould
turnON.
If lights still do not turn ON, refer to the
TROUBLESHOOTING section.
Step5
Restore Power:Restorepoweratcircuitbreakeror
fuse.Installation is complete.
Step 7
Device Mounting: TURN OFF POWER AT CIRCUIT
BREAKER OR FUSE.
Step 6
Installationmaynowbe
completedbytightening
mountingscrewsintowall
box.Attachwallplate.
OPERATION
NOTE: Dresswireswithabendas
shownindiagraminordertorelieve
stresswhenmountingdevice.
For additional information, contact Leviton’s Techline at
1-800-824-3005orvisitLeviton’swebsiteatwww.leviton.com
ThisproductiscoveredbyU.S.Pat.No.7,924,155&correspondingforeignpatents.
©2012LevitonManufacturingCo.,Inc.AllRightsIncludingTradeDressRightsReserved
DECORAisatrademarkofLevitonManufacturingCo.,Inc.registeredintheUnited
States,Canada,MexicoandChina.
ADJUSTMENT SETTINGS TROUBLESHOOTING
Lights do not operate with push pad and LED indicator does not
blink when motion is present:
• Ensurepropergroundconnectionispresentinthewallbox.
Whenconrmed,verifywiringconnectionstosensor.
Lights do not switch ON when motion is detected (IPS02):
• Motionisbeyondsensingrange,moveclosertoswitch.
• Adjustthelightleveladjustmenttowardlighter(counterclockwise),
dependingonroomconditions.
Lights always stay ON:
• ChecktimedelaysettingsandcomparetohowlongthelightsstayON.
• Ensurethatnomotionoccursincoverageareafortimeselected.
• Checkthatswitchisnotinstallednearaheatsource(e.g.,stove,lights,
heatvents)ordetectingmotionfromanadjacentarea(e.g.,hallway
trafc).Ifso,switchmayhavetoberelocated.
Lights do not turn ON - IPV02:
• Checkthatcontrolisinstalledcorrectly.
• CheckthatpowerisON.
• Checkthatlightbulbisfunctioning.
NOTE:Ifproblemscontinue,consultanelectrician.
IPS02
Auto On: LightswillautomaticallyturnONwhen
roomisoccupiedormotionisdetected.
TheIPS02willswitchlightsOFFwhenno
motionisdetectedinun-occupiedroomafterset
periodoftime.
Time delay adjustment:Refertosectionon
Adjustmentsettings.
TheIPS02willmanuallyturn-onlightsorthe
loadbydepressingtheON/OFFpaddleonthe
device.TheIPS02canbesettoonlyturnONby
thepushpad(noautomaticONoperation)byadjustingtheambientlight
controltothe"0"position.
IPV02
Manual On:TheIPV02requirestheusertomanuallyturn-onlightsorthe
loadbydepressingtheON/OFFpaddleonthedevice.
Thelightsorloadwillautomaticallyturn-offwhentheroomisleft
un-occupiedforasetperiodoftime.
Time delay adjustment:RefertosectiononAdjustmentsettings.
Locator Light LED:
LEDblinksonceevery2secondswhenmotionisdetectedandiftheload
isONorOFF.
FCC COMPLIANCE STATEMENT
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttofollowing
twoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevice
mustacceptanyinterferencereceived,includinginterferencethatmaycauseundesired
operationofthedevice.
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigital
Device,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovide
reasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.This
equipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalled
andusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethatinterferencewillnotoccurina
particularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioor
televisionreception,whichcanbedeterminedbyturningtheequipmentOFFandON,
theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowing
measures:
•ReorientorrelocatethereceivingAntenna.
•Increasetheseparationbetweentheequipmentandthereceiver.
•Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe
receiverisconnected.
•Consultthedealeroranexperiencedradio/tvtechnicianforhelp.
FCC CAUTION
AnychangesormodicationsnotexpresslyapprovedbyLevitonManufacturingCo.,Inc.,
couldvoidtheuser'sauthoritytooperatetheequipment.
SENSING AREA COVERAGE
Field-of-View (Horizontal)
Side (Vertical) Field-of-View
Testing your Device prior to mounting in
wall box:
1. Withpowerrestoredandwallplateremoved,removefaceofdeviceto
exposesettingcontrols,seecolorchangeinstructionsinpage1.Use
yourngerorasmallscrewdrivertoadjustthelightsensitivityandtime
settingsonthedeviceasfollows:
Light Level Adjustment:
• Turnthecontrolclockwise.LightswillturnONinlighterconditions.
• Turnthecontrolcounterclockwise.LightswillturnONinlesslighting
conditions.
Time Selection:
• Adjustthetimeselectortothedesiredlengthoftimethelightsareto
remainON.LightswillremainONfrom30secondsto30minutesafter
theroomisvacated.
• Turnthecontrolclockwise.LightswillremainONupto30minutes.
• Turnthecontrolcounterclockwise.LightswillremainONupto30
seconds.
2. Testthatthelightlevelandtimeselectionareasdesired.Ifnot,repeat
adjustmentsuntilsatised.
3. Mountwallplate.INSTALLATION IS COMPLETE.
Lens
Push
Pad
Locator
Light
1.5m
5ft
30ft
9.1m
30ft
9.1m
6ft
1.7m
1.8m
6ft
5ft
1.5m
30ft
9.1m
1.4m
4ft
8.4m
27ft
2.1m
7ft
1.5m
5ft
1.2m
4ft
1.7m
6ft
2.6m
8ft
Light Level
Adjustment
Time
Selection
1 2
0 3
1 2
0 3 0
1
2
3
Settings
30Sec
5Min
15Min
30Min
Time
NOTE:TooperatetheIPS02asavacancysensor(ManualON/AutoOFF):
rotatethelightlevelsensitivityfullycounterclockwise.
FOR CANADA ONLY
Forwarrantyinformationand/orproductreturns,residentsofCanadashouldcontact
LevitoninwritingatLeviton Manufacturing of Canada Ltd to the attention of
theQualityAssuranceDepartment,165HymusBlvd,Pointe-Claire(Quebec),
Canada H9R 1E9orbytelephoneat1800405-5320.

This manual suits for next models

1

Other Leviton Security Sensor manuals

Leviton HB011-PDX User manual

Leviton

Leviton HB011-PDX User manual

Leviton 47A00-2 User manual

Leviton

Leviton 47A00-2 User manual

Leviton ZLS10-ILW User manual

Leviton

Leviton ZLS10-ILW User manual

Leviton IPSD6 User manual

Leviton

Leviton IPSD6 User manual

Leviton decora OSSMT-M3 User manual

Leviton

Leviton decora OSSMT-M3 User manual

Leviton CRS4K User manual

Leviton

Leviton CRS4K User manual

Leviton decora ODS10-TD Series User manual

Leviton

Leviton decora ODS10-TD Series User manual

Leviton DOS02 User manual

Leviton

Leviton DOS02 User manual

Leviton Provolt ODC10-UDW User manual

Leviton

Leviton Provolt ODC10-UDW User manual

Leviton GreenMAX OSR15-MCW User manual

Leviton

Leviton GreenMAX OSR15-MCW User manual

Leviton 61A00-1 Mounting instructions

Leviton

Leviton 61A00-1 Mounting instructions

Leviton ODSMT-MD User manual

Leviton

Leviton ODSMT-MD User manual

Leviton ODC15-IDW User manual

Leviton

Leviton ODC15-IDW User manual

Leviton ZLS10-IDW User manual

Leviton

Leviton ZLS10-IDW User manual

Leviton decora IPV05 User manual

Leviton

Leviton decora IPV05 User manual

Leviton Intellect Solo Sensor ZLS05-ILW User manual

Leviton

Leviton Intellect Solo Sensor ZLS05-ILW User manual

Leviton ODC Series User manual

Leviton

Leviton ODC Series User manual

Leviton DECORA ODS15-IDI Series User manual

Leviton

Leviton DECORA ODS15-IDI Series User manual

Popular Security Sensor manuals by other brands

Stahl Intrinspak operating instructions

Stahl

Stahl Intrinspak operating instructions

Mars ATL-88-1A Operation and maintenance manual

Mars

Mars ATL-88-1A Operation and maintenance manual

Kidde KI-PHD Installation sheet

Kidde

Kidde KI-PHD Installation sheet

Bacharach MVR-300 installation guide

Bacharach

Bacharach MVR-300 installation guide

Risco ShockTec 600S installation instructions

Risco

Risco ShockTec 600S installation instructions

Rielta STEKLO-3RK installation guide

Rielta

Rielta STEKLO-3RK installation guide

SCIEX ExionLC Operator's guide

SCIEX

SCIEX ExionLC Operator's guide

Axis T8331 series installation guide

Axis

Axis T8331 series installation guide

Hytronik HCD038+HIR17 Installation and instruction manual

Hytronik

Hytronik HCD038+HIR17 Installation and instruction manual

3M DBI SALA 8705 Series User instruction

3M

3M DBI SALA 8705 Series User instruction

Wenglor P1MH Series operating instructions

Wenglor

Wenglor P1MH Series operating instructions

Siemens QBM4000 Series quick start guide

Siemens

Siemens QBM4000 Series quick start guide

AFRISO AHD 10 operating instructions

AFRISO

AFRISO AHD 10 operating instructions

BFT SIBOX instructions

BFT

BFT SIBOX instructions

System Sensor ED-TI Installation and maintenance instructions

System Sensor

System Sensor ED-TI Installation and maintenance instructions

DEWESOFT DC-CT Technical reference manual

DEWESOFT

DEWESOFT DC-CT Technical reference manual

GREENLINE GT-16 instruction manual

GREENLINE

GREENLINE GT-16 instruction manual

Vision-EL 80402 instructions

Vision-EL

Vision-EL 80402 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.