ABuilding Safety. Building Security.
Optical-Thermal Detector
OH-13001
• Addressable conventional technology
• Combination of optical and thermal
characteristics of fi re
• Individual detector addressing by
means of optional address module
• Optional connection of remote
indicator
• Sealed electronics
Description
The Optical-Thermal Detector OH-13001 uses both the
scattered light principle as well as a separate thermal
detection unit. It was developed to detect the characte-
ristics of fi re in a wide range of applications, and to avo-
id deceptive alarms. The modern design of both measu-
rement systems and the analysis of the parameters by
means of a special algorithm allow to reliably evaluate
the characteristics of fi re. This makes it an all-rounder
that is used in virtually all fi elds of fi re detection.
Intelligent evaluation algorithms compensate for the
contamination of the optical measurement system,
thus keeping the response sensitivity of the detector
constant for a long time. In this way, false alarms can
be avoided to a great extent. If the contamination can
not be compensated any further, or if a fault occurs in
the measurement system, this is indicated by a yellow
fl ashing of the multicoloured status LED.
Addressable conventional technology is used for alarm
transmission to the fi re detection control panel. By
means of the optional Address Module NG60-1, each
detector can be addressed individually, thus allowing to
display the detector address, as well as an assigned
element text, on a suitable fi re detection control panel.
The detector can be attached to various bases and it
can be protected against theft.
Specifi cations
Operating voltage Supply through the detector line voltage
Current consumption typ. 65µA (quiescent)
Ambient temperature - 40°C to +70°C (no condensation or icing)
Relative humidity 0 – 98% (no condensation)
Dimensions ø × H 100 × 42 (mm)
Colour white
Weight 80g
Approval VdS G204040
Order number 241061
Order name Optical-Thermal Detector/Conv./ORBIS/Apo OH-13001

Other LST Security Sensor manuals

LST ECO1000BREL24L User manual

LST

LST ECO1000BREL24L User manual

LST 5451EIS User manual

LST

LST 5451EIS User manual

LST FI750/RF/OT User manual

LST

LST FI750/RF/OT User manual

LST 2251CTLE User manual

LST

LST 2251CTLE User manual

LST Orbis 246042 User manual

LST

LST Orbis 246042 User manual

LST Series 200 User manual

LST

LST Series 200 User manual

LST FI750/RF/OT User manual

LST

LST FI750/RF/OT User manual

LST 2100RFT-AS User manual

LST

LST 2100RFT-AS User manual

LST 5351E User manual

LST

LST 5351E User manual

LST Series 65/XP95 User manual

LST

LST Series 65/XP95 User manual

LST 2351TEM User manual

LST

LST 2351TEM User manual

LST AW-55000-420 User manual

LST

LST AW-55000-420 User manual

LST IR2 16581 User manual

LST

LST IR2 16581 User manual

LST FTX-P1 User manual

LST

LST FTX-P1 User manual

LST 5351TE User manual

LST

LST 5351TE User manual

LST AD-58000-400 User manual

LST

LST AD-58000-400 User manual

LST UVIR2 16591 User manual

LST

LST UVIR2 16591 User manual

LST ECO1000 User manual

LST

LST ECO1000 User manual

LST B401RM User manual

LST

LST B401RM User manual

LST 200 Series User manual

LST

LST 200 Series User manual

LST ASR-45681-242 User manual

LST

LST ASR-45681-242 User manual

LST Orbis RB-10004 User manual

LST

LST Orbis RB-10004 User manual

LST 246100 User manual

LST

LST 246100 User manual

LST AMS-58000-700 User manual

LST

LST AMS-58000-700 User manual

Popular Security Sensor manuals by other brands

Honeywell FSL100-IR3 Technical handbook

Honeywell

Honeywell FSL100-IR3 Technical handbook

EMX LRS-C1 instruction manual

EMX

EMX LRS-C1 instruction manual

Sofamel D-WATCH 648 instructions

Sofamel

Sofamel D-WATCH 648 instructions

WATERGUARD Solo user manual

WATERGUARD

WATERGUARD Solo user manual

Fireye FLAME SIGNATURE SCANNER 1000 manual

Fireye

Fireye FLAME SIGNATURE SCANNER 1000 manual

Niko 353-702111 M42LR user manual

Niko

Niko 353-702111 M42LR user manual

AJAX DoorProtect quick start guide

AJAX

AJAX DoorProtect quick start guide

Honeywell Purple Peeper C7012A instructions

Honeywell

Honeywell Purple Peeper C7012A instructions

Tatsuta Electric Wire & Cable AD-AS-1LDMA Operation manual

Tatsuta Electric Wire & Cable

Tatsuta Electric Wire & Cable AD-AS-1LDMA Operation manual

Theben compact office EIB installation manual

Theben

Theben compact office EIB installation manual

SENSTAR MPS-4100 Product guide

SENSTAR

SENSTAR MPS-4100 Product guide

THORLABS APD440A Operation manual

THORLABS

THORLABS APD440A Operation manual

CoCo APIR-2150 Quick installation guide

CoCo

CoCo APIR-2150 Quick installation guide

MUELLER CO. 107 Series instructions

MUELLER CO.

MUELLER CO. 107 Series instructions

Crow SH-SIRINT-9F instruction manual

Crow

Crow SH-SIRINT-9F instruction manual

IMMAX NEO 07526L user manual

IMMAX

IMMAX NEO 07526L user manual

Theben 201 9 290 installation manual

Theben

Theben 201 9 290 installation manual

Ger Detect River G user manual

Ger Detect

Ger Detect River G user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.