Brahler MSI8V CDSVAN User manual

BRÄHLERICS
CDSVAN Digital Conference Management System
MSI8V Compact Transmitter
Operating instructions
Ver. 1.3

Printed in Germany
If you have questions about this manual please contact:
Brähler ICS Konferenztechnik
International Congress Service AG
P.O. Box 32 64
D-53627 Königswinter
Wahlfelder Mühle 3
D-53639 Königswinter
Tel.: +49 (0)2244 930-100
E-Mail: [email protected]m
You will find further information about our products on the internet at:
http://www.braehler.com
©2003
BRÄHLER ICS AG, Königswinter
All rights reserved, especially (also partly) the translation, reprint, reproduction through copying or other similar
methods.
BRÄHLER ICS reserves the right to make changes without notice.
INFRACOM® and DIGIMIC® are registered trademarks
Operating instructions BGE-MSI8V.doc
Mar-07

CDSVAN MSI8V
3
CAUTION
DANGER OF ELECTRIC SHOCK
DO NOT OPEN DEVICES
Do not open housing with mains cable connected.
Maintenance operations may only be executed by
qualified personnel.
Our equipment and installations have been built and tested according to the latest state of the art. Under normal
conditions, they do not require any special maintenance.
However, please be aware of the following:
secure and stable position of the installation
sufficient ventilation - never operate equipment near heat sources such as heating radiators etc.
power connection - install all power cables to avoid damaging
connecting cables - avoid trip-traps
liquids - avoid penetration of liquids into the housing
exclusively operate equipment via wall sockets that are connected to ground according to the relevant
specifications and regulations
Warning: Never expose equipment to rain or humidity
Please be also aware of the fact that rough handling of the equipment, such as strong bumps or vibrations, may
result in damages. Inappropriate handling and storage, i.e. handling and storage not in conformity with the
operating instructions, may as well lead to equipment damages.

MSI8V CDSVAN
4

CDSVAN MSI8V
5
Content
About this manual ............................................................................................. 6
Symbols ........................................................................................................................6
Important remarks............................................................................................. 7
For customers in the EU and in the USA .............................................................................7
For customers in the United Kingdom ................................................................................ 7
Safety ...........................................................................................................................7
Installation ...................................................................................................................7
Cleaning........................................................................................................................7
Repacking......................................................................................................................7
General .........................................................................................................................8
Important information .................................................................................................... 8
Overview........................................................................................................... 9
System function .............................................................................................................9
Use...............................................................................................................................9
Compact transmitter MSI8V ............................................................................................ 10
Installation and starting up...............................................................................12
Termination LINK.......................................................................................................... 12
Connecting the VAN-IN socket ........................................................................................ 12
Connecting the VAN-LINK socket..................................................................................... 12
Connecting LINE-OUT sockets ......................................................................................... 12
Connecting RF-LINK socket ............................................................................................ 13
Connecting radiator sockets ........................................................................................... 13
Connecting mains power ................................................................................................ 13
Starting Up ......................................................................................................14
Tuning input/output levels ............................................................................................ 14
OPERATION.......................................................................................................15
LED AF and ON on front side........................................................................................... 15
Infrared test diodes ...................................................................................................... 15
Overview ..................................................................................................................... 16
Applications.....................................................................................................17
Appendix .........................................................................................................20
Technical Data MSI8V .................................................................................................... 20
Optional accessories...................................................................................................... 20
Bloc diagram................................................................................................................ 21
System Components ...................................................................................................... 21
Troubleshooting ........................................................................................................... 22
Table of language signs (ISO639).................................................................................... 23
Service form................................................................... Fehler! Textmarke nicht definiert.
Adresses ..........................................................................................................26

MSI8V CDSVAN
6
About this manual
Symbols
The following symbols and fonts are used in this manual:
Indicates an important note, which has to be followed to guarantee that the functions of the unit, the
security of any data or your health are not put at risk
Indicates additional information, remarks and tips
Describes activities that must be performed in the shown order
Words in bold letters require your special attention.

CDSVAN MSI8V
7
Important remarks
For customers in the EU and in the USA
Our equipment has been tested and complies with the requirement of the CE test. This guarantees the protection
against harmful interferences, when the equipment is operating in a commercial environment. If the unit is not
proper installed to this user manual it may causes radio interferences. Any changes or modifications not explicit
approved in this manual could void your authority to operate this equipment.
For customers in the United Kingdom
The wires in the main lead are colored in accordance to the following codes:
Green-and-yellow: Earth
Blue: Neutral
Brown Live
If the colours of the wires in the mains lead of this unit are not corresponding with the coloured markings of the
terminals in your plug, so please proceed as follows:
The green-and-yellow wire must be connected to the plug terminal marked with the letter E, with the safety earth
symbol or with green-and-yellow colour. The blue wire must be connected to the terminal marked with the letter N
or with black colour. The brown wire must be connected to the terminal marked with the letter L or with red colour.
The equipment must be connected to earth!
Safety
Check that the operating voltage of the unit is identical with the voltage of your local mains power. If a voltage
conversion is required, consult your BRÄHLER ICS dealer or qualified personnel.
Should any liquid or solid object fall into the cabinet, unplug the unit and have it checked by qualified personnel
before it will be used again. Unplug the unit from the wall outlet or set the Main Power switch to OFF if it is not used
for several days. To disconnect the cord, pull it out holding the plug. Never pull the cord itself.
Installation
Allow adequate air circulation to prevent internal heat accumulation. Do not place the unit on a surface (rugs,
blankets, etc.) that may block the ventilation holes.
Do not install the unit in locations near heat sources such as radiators or air ducts, nor in places exposed to direct
sunlight, excessive dust or humidity, mechanical vibration or shock.
To avoid condensation do not install the unit where the temperature may increase rapidly.
Cleaning
To keep the surface of the housing in a proper condition, periodically clean it with a soft cloth. Large staining may
be removed with a cloth lightly dampened with a mild detergent. Never use organic solvents such as thinners or
abrasive cleaners since these might damage the surface.
Repacking
Save the original shipping box and packing material. For maximum protection, re-pack the unit as originally packed
from the factory.
If not supplied with the equipment, a complete transportation and storage box system is available from BRÄHLER
ICS. We recommend using this system for long-term protection and care.

MSI8V CDSVAN
8
General
Please keep this manual together with the CDSVAN Compact Transmitter MSI8V. If you hand on the units to third
parties, please include this manual.
Please read the manual carefully, taking special care when you see this symbol as it indicates important
information!
This product is conform to the rules of the following European directive:
89/336/EWG
Council directive to the alignment of the rules of rights of all member states about the electromagnetic compatibility,
modified through RL 91/263/EWG, 92/31/EWG and 93/68/EWG of the council. Further information is available on
request.
The warranty will expire, if you cause defectives through inappropriate use or handling of the unit.
Important information
The unit should not be used at the maximum volume setting. Adjust the volume to a more suitable level.
High sound pressure levels will damage your hearing!

CDSVAN MSI8V
9
Overview
The Compact Transmitter MSI8V is used within the CDSVAN Conference System for transmission of 8 audio
channels by infrared light.
System function
The audio signals are converted into frequency modulated infrared light and then transmitted by means of
INFRACOM Radiators HLN82, which are directly connected to the MSI8V. The original (OR) and up to 7 other
languages can be simultaneously transmitted on different carrier frequencies by narrowband frequency modulation.
Infrared radiators transmit the information carried by the audio channels in the form of frequency-modulated
infrared light. The transmitted signals are received by the INFRACOM Receiver IRX and can be monitored by
headphones. Receivers can be moved at will anywhere within the area that is fully illuminated by the radiators.
They can be switched to receive up to 32 channels.
With miniature-switches on the front panel the frequency band can be chosen and the channels can be switched
ON or OFF. With a rotating switch it is possible to assign up to 32 transmission channels.
3 infrared transmitter diodes on the front panel allow monitoring for the technician without radiators.
LEDs on the front panel are indicating the operation mode: channel ON (red) and audio signal available (green).
Use
In combination with the digital microphone management system CDSVAN, the system can provide the best
possible communication facilities for organized events that need to use several languages.
Each and every participant (a term often used is "delegate") can use the microphone system to speak, and what he
or she says will be translated simultaneously so that other delegates will be able to listen to it in one of the several
languages. This technique permits direct communication in several languages even at very large scale events.
It is a simple matter to set up the INFRACOM system in such a way that it is protected against eavesdropping from
outside. Since all information is transmitted in the form of light waves, it is possible to use opaque material as
necessary to limit the area to which it is to be transmitted. Dark curtains drawn across windows, for instance, are
enough to shield a room reliably from the outside world.
Although the CDSVAN system is most commonly used in combination with an INFRACOM interpretation system
and microphone-management system it is also possible to use it for other purposes.
During organized events, for instance, it is possible to use infrared light to transmit information to individual
participants wearing receivers without disturbing anyone else present.
Another example might be museums applications. There it is possible to provide information on individual exhibits
by means of infrared light radiated only to a limited area in front of the particular exhibit. Visitors listen to the
information with receivers and headphones.

MSI8V CDSVAN
10
Compact transmitter MSI8V
Front View
The CDSVAN Compact Transmitter MSI8V is part of the Congress Data System systems VAN (Virtual Audio
Network), which serves the cordless sound transmission by means of infrared light.
The sound signal is thereby converted into a frequency-modulated infrared light signal and emitted via transmitting
diodes. With special INFRACOM® receivers the light signal is recorded and re-converted into a sound signal,
which can then be heard on a set of headphones. Different frequencies of up to 32 channels can be transmitted
simultaneously with an FM narrow band modulation.
The CDSVAN Compact Transmitter MSI8V is used for modulating the sound signals on the different carrier
frequencies and for signal amplification.
The Compact Transmitter consists of a 19" housing (2HU).
Eight channels can be transmitted with one MSI8V (usually defined as Original + 7 languages).
On the front right-hand side of the Compact Transmitter MSI8V there is a POWER switch with a green ON LED
which shows whether the transmitter is switched on. Next to this there are three infrared test diodes for monitoring
the IR-signal even without IR-Radiator.
The operating elements of the eight infrared channels are also on the front side of the console.
Each infrared channel consists of a green AF LED for the original voice and interpreter voice, an ON LED, an ON /
OFF switch, two frequency band switches and a rotary switch for channel setting. This can be used to set the
channels independently of the frequency band switch.
Each channel can be set from OR - Ch31.

CDSVAN MSI8V
11
Rear View
The Compact Transmitter MSI8V contains the following sockets on the rear side:
VAN-IN (RJ45 socket) for connecting to the CDSVAN PC (Computer)
VAN-LINK (RJ45 socket) for cascading (Audio) with a second MSI8V
LINE-OUT: eight sockets for audio recording
RF-LINK: socket for cascading (RF) with further MSI8V
RADIATORS: 2 x BNC sockets for connecting INFRACOM® radiators HLN82A and HLN82B. Up to 10 radiators
can be connected directly at each output.
Mains power connector.

MSI8V CDSVAN
12
Installation and starting up
The Compact Transmitter has an ex-works mains voltage setting of 90 - 250 Volts by 50 – 60 Hz. If there
is another voltage range you must not connect this equipment. In connecting the system, special attention
is to be paid to ensure that all cables are installed in cable ducts or that they are fixed by cable clamps or
adhesive tape in such a way that there is no danger of somebody tripping over them.
Termination LINK
Termination of the LINK socket via DIP switch:
ON: LINK socket not used (open)
OFF: LINK socket connected with another Compact Transmitter MSI8V
Connecting the VAN-IN socket
RJ45 for the connection to the CDSVAN-PC (transmission of the channels)
The input is balanced via AF transformer.
Connecting the VAN-LINK socket
Within a 16 channel system (1+15) the LINK socket can be used to transmit the channels
8 – 15 to the next MSI8V.
In this case the RF-Link socket (next page) also should be connected between the 2 MSI8V.
Connecting LINE-OUT sockets
8 XLR LINE-OUT connector (male):
All eight channels fed into the MSI8V from
the CDSVAN system via CAT5 are
available at these connectors, e.g. for
audio distribution or recording purposes.

CDSVAN MSI8V
13
Connecting RF-LINK socket
BNC socket to cascade further Compact Transmitter MSI8V. To manage more Outputs you
can extend the system to more outputs.
Connecting radiator sockets
IR-LINE 1 and 2: BNC sockets for connecting INFRACOM® radiators HLN82A and
HLN82B. Up to 10 radiators can be connected directly to each socket.
Connecting mains power
Connect the delivered cable with this socket to ensure the
proper working of the Compact Transmitter.

MSI8V CDSVAN
14
Starting Up
The power supply is turned on via the power switch on the front side of the Compact Transmitter MSI8V.
When you use the Compact Transmitter the first time it is necessary to adjust the provided channels.
This procedure will allocate the transmitter frequencies to the respective channels.
For adjusting this allocation refer to the following figure. The scheme is enclosed with the Compact
Transmitter as a separate sticker which may be adhering to the front panel.
OFF
ON
Ch30-Ch37
OFF
ON
Ch14-Ch29
OFF
ON
ChOR-Ch13
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
1
4
1
5
1
6
1
7
OR
1
2
3
4
5
6
7
8
9
IF
10
11
12
13
The following allocation is shown on the figure above:
First figure: Channel 1; second figure: Channel 16; third figure: Channel 32
The left DIP-switch will activate the corresponding channel. DIP switch to ON means channel is active.
Tuning input/output levels
There are no controls necessary for a successful event.
All levels are set and stored within the CDSVAN software environment.

CDSVAN MSI8V
15
OPERATION
Once the CDSVAN system has been properly started up and checked, there is usually no need for any further
intervention from the operator.
Most of the work involved with audio distribution should have been completed during the preselection of channels
and system start-up.
LED AF and ON on front side
AF: This LED indicates a signal on this output (for example line 1).
ON: This LED represents the ON-status of the corresponding output channel.
Remark: You should switch off not used channels to increase the IR power.
ON- and OFF-status is set with the left DIP-switch.
Infrared test diodes
Three transmitting test diodes allow testing the receivers at a maximum
distance of 3 meters between the test-LEDs and the receiver.

MSI8V CDSVAN
16
Overview
Power switch
Illustration 1 AF indicator
LED ON LED DIP-switch setting
channel range Channel
selection 3 Test diodes
VAN-IN LINE OUT,
channel 1-8
VAN-LINK Mains Power
Termination LINK Link connector
BNC Radiator
connectors
Illustration 2

CDSVAN MSI8V
17
Applications
In the following you see some examples in form of a block diagram:
Application 1
This diagram shows a complete application for an eight channel (OR + 7) interpreter system. Monitoring part is the
Receiver IRX together with the IR-Radiator HLN82B.
CDSVAN System Components
•CDSVAN PC: Including CDSVAN Software and DSP Hardware
•MSI8V: Compact Transmitter
•HLN82B: Radiator (10W/20W)
•IRX: Receiver for up to 32 channels

MSI8V CDSVAN
18
The next diagram (Application 2) shows the extension to a 16 channel system:
IRX
HLN82B
Compact
Transmitter
16x line out
(recording, PA)
MSI8V
VAN-link
VAN-IN
BNC
Ch16
Ch9
IR-LINK
MSI8V
VAN-link
VAN-IN
BNC
Ch8
Ch1
IR-LINK
DATA signal
CDSVAN PC
Compact
Transmitter
Application 2
Two Compact Transmitters MSI8V are linked to one system. The monitoring part consists of the Receiver IRX
together with the IR-Radiator HLN82B.
CDSVAN System Components
•CDSVAN PC: including CDSVAN Software and DSP Hardware
•MSI8V: Compact Transmitter
•HLN82B: Radiator (10W/20W)
•IRX: Receiver for up to 32 channels

CDSVAN MSI8V
19
The next diagram (Application 3) shows a complete interpreter system:
Application 3
This diagram shows a complete application for a multi channel interpreter system. Monitoring part is the Receiver
IRX together with the IR-Radiator HLN82B.
CDSVAN System Components
•CDSVAN PC: including CDSVAN Software and DSP Hardware
•MSI8V: Compact Transmitter
•PSU01/04: Power Supply
•DOLV: Interpreter console for one interpreter
•HLN82B: Radiator (10W/20W)
•IRX: Receiver for up to 32 channels

MSI8V CDSVAN
20
Appendix
Technical Data MSI8V
The unit is complying with the international standard IEC914.
Connections
•VAN-IN (1 x RJ45-socket) for connection to the CDSVAN-PC
•VAN-LINK (1 x RJ45-socket) for cascading (Audio) with a second MSI8V
•LINE-OUT (8 x XLR-plug) AF outputs for audio recording
•IR-LINE (2 x BNC-socket)
1: Connection for up to 10 INFRACOM radiators HLN82
2: Connection for up to 10 INFRACOM radiators HLN82
•IR-LINK (1 x BNC-socket) for cascading (RF) with further MSI8V
Features
•Green lighted mains switch for power ON indication
•Red LEDs for channel switched ON
•Green LEDs for Audio available (AF)
Transmission frequency
•55kHz - 1335kHz (channel 31) in 40kHz steps
Intermediate frequency
•455 kHz
Measurements
•Distortion: < 0.2%
•Signal-to-noise ratio: > 70dB
•Channel separation: > 60dB
Power Supply
•Mains power: (90 ... 250)VAC, (50 ... 60)Hz
•Power consumption: 40VA max
Housing
•19”, 2 HE, Aluminum, “silver” anodized
•W x H x D: (433 x 88 x 305)mm
Weight
•4.6kg
Optional accessories
(not included in delivery)
•INFRACOM Radiator HLN82
•INFRACOM Receiver IRX
•CAT5 cable (Standard), shielded, different length available
•BNC cable (50 Ohm) different length available
•Mounting brackets for rack assembly
Table of contents
Other Brahler Conference System manuals