•All components need to
be installed in accordance
with the user manual
instructions for correct
performance of unit.
•This appliance should be
used in conjunction with
a safety switch.
•This appliance is not
intended for use by
persons (including
children) with reduced
physical, sensory or
mental capabilities,
or lack of experience
and knowledge, unless
they have been given
supervision or instruction
concerning use of the
appliance by a person
responsible for their safety.
2 Cli-Mate Recommends
Safety First
7 Components
9 Functions
12 Care & Cleaning
13 Troubleshooting
Contents

3
•Do not operate any
appliance with a damaged
cord or plug or after the
appliance malfunctions, or
has been damaged in any
manner.
•If the supply cord
is damaged, it must
be replaced by the
manufacturer, its service
agent or similarly
qualified persons in order
to avoid a hazard.
•Children should be
supervised to ensure that
they do not play with the
appliance.
•Do not use appliance for
other than intended use.
•Do not disassemble, repair
or re-form the unit, it may
cause injury, fire or other
malfunctions. A qualified
service agent must make
all service adjustments.
Unauthorised
disassembling of the
product will void
the warranty.
•Unplug from outlet when
not in use and before
cleaning. Never plug in
or unplug unit with wet
hands.
•Do not use unit outdoors
or expose to greasy
or damp environments.
•Keep the rear air inlet
and outlet free from air
blocking materials such
as clothing, plastic bags
or papers. Air flow
is required for the unit
to operate effectively.
•Place unit on a flat
location at least 30cm
from wall or other
appliances.
•When the unit is in
operation, keep all body
parts, jewellery, hair and
loose clothing away from
the openings
•Unit must be placed
on a stable flat surface to
reduce possible excessive
vibration and noise.

4
•Keep the unit away
from fire, flammable gas,
combustible products
or vapours, and corrosive
substances.
•Do not operate the unit
without filters.
•When transporting the
air purifier, always hold
the handles on the side
of the unit.
•To protect against
fire, electric shock and
personal injury, do not
immerse cord, plugs,
or appliance in water
or other liquid.
•Do not place on or near
a hot gas, electric burner
or heating appliance.
•Check voltage to be sure
that the voltage indicated
on the nameplate agrees
with your voltage.
SPECIAL
PRODUCT
INSTRUCTIONS
•This appliance is designed
for household use only. Do
not use
this unit outdoors or on
wet surfaces.
• To achieve highest
efficiency, please close all
windows
and or doors.
• The appliance air vents
and air grilles must not
be obstructed at any time.
Air flow is required for the
unit to operate effectively.
Place unit in a flat well-
ventilated location at least
30cm from wall or other
appliances.
• Units must be placed on
a flat stable surface to
reduce possible excessive
vibration and noise.
• Units must never be
placed and operated on
an angle as water spillage
from reservoir can occur.

5
• Empty the water when
water reservoir is full or
not in use for a prolonged
period.
• Recommended operating
temperature range is
minimum 5 degrees
Celsius (RH 41%) and
maximum 37 degrees
Celsius (RH 98%).
• Any servicing other
than cleaning and
user maintenance will
violate the terms of
this WARRANTY and
warranty will be null and
void.
Note: RH = Relative Humidity
IMPORTANT
SAFEGUARDS
FOR ALL
ELECTRICAL
APPLIANCES
•Unwind the power cord
fully before use.
• Do not let the power
cord hang over the edge
of a bench or table, touch
hot surfaces, or become
knotted.
• To protect against electric
shock do not immerse
power cord, power plug
or appliance in water
or any other substance.
• This appliance is not
intended for use by
persons (including
children) with reduced
physical, sensory or mental
capabilities, or lack of
experience or knowledge,
unless they have been
given supervision or
instruction concerning
use of the appliance
by a person responsible
for their safety.

6
FOR HOUSEHOLD USE ONLY
SAVE THESE INSTRUCTIONS
•Children should be
supervised to ensure
they do not play with
the appliance.
•It is recommended
to regularly inspect the
appliance. Do not use the
appliance if power cord,
power plug or appliance
becomes damaged in
anyway. Return the
entire appliance to
the nearest authorised
Cli-Mate Service Centre
for examination and/
or repair.
•Any maintenance other
than cleaning should
be performed at an
authorised Cli-Mate
Service Centre.
•This appliance is
recommended for
household use only.
Do not use this appliance
for anything other than
its intended use. Do not
use in moving vehicles or
boats. Do not use outdoors.
Misuse may cause injury.
•The installation of
a residual current
device (safety switch)
is recommended to
provide additional safety
protection when using
electrical appliances.
It is advisable that
a safety switch with
a rated residual operating
current not exceeding
30mA be installed in the
electrical circuit supplying
the appliance. See your
electrician for professional
advice.
WARNING
Fully unwind the cord
before use.

7
Components
A. Dry Air Outlet
B. Handle
C. Humid Air Inlet Grille
D. Continuous Drainage Outlet
(For hose connection)*
E. Water Reservoir
F. Power Cord
G. LED Monitor
H. Control Panel
I. Water Pane
* Continuous drainage hose is an extra drainage
option; hose does not need to be connected if using
the water reservoir to catch condensed water.
I
E
F
G
H
A
C
D
B

8
Components
POWER
Turns unit ON/OFF.
MODE
Allows selection of dehumidification speed
• Quiet dehumidification (Low speed)
• Normal dehumidification (Medium speed)
• Fast dehumidification (High speed)
HUMID
Allows selection of different room relative
humidity ratios (40%/50%/60%). Unit is
automatically set on continuous mode when
turned on.
TIMER
To set automatic off timer at 1 /2 / 4 /8 hour
settings.
ION
Switches ionizer ON/OFF.
CONTROL PANEL

9
OPERATION INSTRUCTIONS
1. Plug unit into power socket and press
POWER button to turn unit on, unit
will beep three times and LED monitor
lights will illuminate indicating current
settings. The dehumidification setting is
automatically set at continuous.
2. To select the dehumidification mode,
press MODE button to select Quiet (L),
normal (M), or fast (H) dehumidification
respectively. LED light will indicate current
setting.
NOTE
When fast dry (H) dehumidification mode is
set, humidity ratio setting cannot be set.
3. To select room relative humidity (RH)
ratio, press HUMID button to select 40%-
50%-60% respectively. When selecting
the HUMID ratios this will change the
unit operating MODE accordingly (Low/
Medium/Continuous).
NOTE
If the ambient relative humidity (RH) is less
than 2% of the selected room relative humidity
ratio the unit will automatically switch off,
(refer to POWER DOWN PROCEDURE on
page 9)
4. To turn on ioniser function, press ION
button. ION LED light will remain blinking
when ionizing function is operating.
5. To set automatic off timer, press TIMER
button until LED light is on desired time
1/2/4/8 hours.
PRODUCT SPECIFICATIONS CLI-DH8D AIR DEHUMIDIFICATION SYSTEM
DEHUMIDIFICATION 8 LITRES/DAY
DEHUMIDIFYING CAPACITY 0.33 kg/hour
AIR CIRCULATION 120 cbm/hour
POWER CONSUMPTION 650 watts
CAPACITY OF WATER TANK 2.0 L
NOISE LEVEL ≤50dB
N.W 6.3 kgs
G.W 7.0 kgs
SUITABLE ROOM SIZE 30 m²
PRODUCT DIMENSIONS 351 x 180 x 500 mm
Functions

10
6. As unit operates, condensed water will
drain into water reservoir. When water
reservoir is full, unit will beep 10 times and
WATER FULL indicator light will blink.
Unit will automatically stop operating.
The water reservoir must be removed and
emptied before unit will operate again.
POWER DOWN PROCEDURE
Important: As a protection mechanism the
fan will continue to run for 4 minutes after the
internal heater switches off.
To switch off the unit press the POWER button.
The heater will immediately switch off and
the LED lights on the display panel will switch
off. The fan and motor will run for a further 4
minutes before switching off automatically.
ENERGY SAVING FUNCTION
When the set humidity ratio is reached the
unit will automatically power down. The unit
will then test the environment humidity by
running on low speed for 3 minutes in every
30 minutes. If the humidity raises above the set
humidity then the unit will automatically start.
PROTECTION OF INTERNAL OVER
HEATING
In the event the unit malfunctions and
overheats due to air intake or air outlet being
obstructed or blocked by foreign objects, the
unit will shut down automatically. Unplug unit
from wall socket and allow unit to cool down
for a minimum of 5 minutes before operating
the unit again.
NOTE
The appliance air vents and air grilles must not
be obstructed at any time. Air flow is required
for the unit to operate effectively. Place unit
in a flat well-ventilated location at least 30cm
from wall or other appliances. Units must
be placed on a flat stable surface to reduce
possible excessive vibration and noise.
TILT PROTECTION
In the event that the unit is knocked over or
tilted over 45o angle while in operation, the
internal heater will stop operating. The fan
and motor will continue to run for 4 minutes
(to cool down the unit) before stopping
completely.
Once the machine is fully upright, the unit
will need to be turned on by pressing POWER
button. The unit will start operating as per its
last settings, except for the timer which will
need to be re-set.

11
Optional Continuous Drainage Installation
1. Ensure that unit is OFF and unplugged
from wall socket.
2. Remove water reservoir out and connect
water drain hose to spigot (continuous
drainage outlet) as shown
3. The other end of this hose must be placed
over a water drain.
NOTE
For the unit to drain correctly, no part of the
hose should be above the level of the water
spigot (continuous drainage outlet).

12
Care & Cleaning
CAUTION: Before carrying out any
maintenance or cleaning of the unit, make
sure that the power to the unit is turned off and
power cord is removed from the power socket.
• Do not clean unit with any abrasive cleaning
agents or solvents.
• Do not apply any water directly to the unit of
cleaning.
• Only use a soft clean cloth for all cleaning
purpose
CLEANING THE AIR FILTER:
Remove Air Intake Grille below to access filter.
Use a vacuum cleaner or wash in cool water
to clean filter. Allow to dry thoroughly before
replacing filter and Air Intake Grille in the unit.
Air filter should be cleaned every 3 months for
unit to continue to perform as stated.
Pull out
the filter
as shown
STORAGE
If not using the unit for a prolonged period,
switch off and unplug the unit, empty the water
reservoir, and allow minimum of two days for
unit to dry before packing away. Keep unit in a
dry and ventilated place.
REPAIR
If the unit or power cord is damaged, stop
using immediately and bring the unit to
authorised service center for repair, never
attempt to dismantle, repair or modify the unit
by yourself. Warranty will be null and void.

13
PROBLEM POSSIBLE CAUSES EASY SOLUTION
No Power. • Unit is not plugged into
wall socket. • Check connection to wall socket.
No Air. • Unit is not plugged into wall socket
• Humidity ratio (if set) has been
reached.
• Air outlet blocked.
• Water Reservoir is full.
• 1. Check connection to wall socket
• Wait 30 minutes, turn unit back on.
• Ensure there are no objects
obstructing air outlet.
• Empty water reservoir.
Unit Overheating. • Air ventilation around unit
not sufficient.
• Air intake grille or air outlet is being
obstructed or blocked by foreign
objects.
• There must be at least 30cm between
unit and wall or other appliances.
• Ensure there are no object
obstructing the air intake grille or
air outlet.
Loud Noise. • Unit not on a level flat surface.
• Faulty internals.
• Reposition or relocate unit onto a flat
surface.
• Call customer care.
Water at Base of Unit. • Water reservoir not installed
correctly.
• Continuous drainage hose not
connected to spigot properly.
• Continuous drainage hose outlet
not over water drain.
• Reinstall water reservoir.
• Check hose connection.
• Check hose outlet is flowing into
water drain.
Beeping Alarm Noise. • Water Reservoir is Full. • Remove and empty water reservoir.
Troubleshooting

14
Notes

15
Notes

Breville is a registered trademark of Breville Pty. Ltd. A.B.N. 98 000 092 928.
Copyright Breville Pty. Ltd. 2018.
Due to continued product improvement, the products illustrated/photographed
in this brochure may vary slightly from the actual product.
CLI-DH8D ANZ – A18
Web: www.breville.co.nzWeb: www.breville.com.au
Australian Customers
Phone: 1300 139 798
New Zealand Customers
Phone: 0800 273 845
Breville Customer Service Centre
Table of contents
Other Breville Other manuals
Popular Other manuals by other brands

Media Pointe
Media Pointe HD PORTAL user manual

Oceania
Oceania Optimale Series Installation instruction

Franke
Franke SIRX711C Installation and operating instructions

Tetra
Tetra ReptoFilter 250 instruction manual

Elaflex
Elaflex Swivel EA 075 Assembling manual

Oase
Oase HighLine Classic LED daylight 70 operating instructions

Daiwa
Daiwa TATULA-R100H operating instructions

Lince
Lince GOLD 869 OBLO Series Installation, operation and maintenance manual

NEC
NEC POWERUP RELEASE FINAL manual

Aquadistri
Aquadistri BlueMarine Skimmer 600 instruction manual

ABB
ABB REX 521 Technical Reference Manual, General

DAVIS
DAVIS Weather Envoy install guide