Brighter Eye 1200 Pro User manual

1
Eye 1200 Pro

2
TABLE OF CONTENTS
1. Safety Instructions.............................................................................................................3
2. Technical Specifications....................................................................................................4
3. How To Control Unit ..........................................................................................................5
4. How to Control Unit with Art-Net .....................................................................................11
5. Troubleshooting...............................................................................................................12
6. Cleaning...........................................................................................................................13
Statement
The product has full capability and intact packing when it leaves factory. All the users should
comply with provided warnings and manual. Any damages caused by misuse are not included in
our guarantee. We cannot be responsible for any malfunctions & problems owing to ignoring the
manual.

3
1. Safety Instructions
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also
receive this instruction booklet.
Unpack and check carefully there is no transportation damage before using the unit.
Before operating, ensure that the voltage and frequency of power supply match the power requirements of
the unit.
It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
The unit is for indoor use only. Use only in a dry location.
The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be
sure that no ventilation slots are blocked.
Disconnect main power before replacement or servicing.
Make sure there are no flammable materials close to the unit while operating as it is fire hazard.
Use safety cable when fixes this unit. DO NOT handle the unit by taking its head only, but always by taking its
base.
Maximum ambient temperature is Ta: 40℃. DO NOT operate it where the temperature is higher than this
Unit surface temperature may reach up to 85℃.
DO NOT touch the housing bare-hands during its operation. Turn off the power and allow about 15 minutes
for the unit to cool down before replacing or serving.
In case of serious operating problem, stop using the unit immediately. Never try to repair the unit by
yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the
nearest authorized technical assistance centre. Always use the same type spare parts.
DO NOT touch any wire during operation as high voltage might be causing electric shock.
Warning:
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture.
DO NOT open the unit within five minutes after switching off.
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.
Caution:
There are no user serviceable parts inside the unit. DO NOT open the housing or attempt any repairs by yourself.
If your unit requires service, please contact your nearest dealer.
Installation:
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid
vibration and slipping while operating. And make sure that the structure to which you are attaching the unit is
secure and is able to support a weight of 10 times of the unit’s weight. Always use a safety cable that can hold 12
times of the weight of the unit when installing the fixture.
The equipment must be fixed by professionals. And it must be fixed at the safe place where it is not available for
other people.

4
2. Technical Specifications
Light Sources: 19*40W 4IN1 OSRAM RGBW COB LED
Beam Angle:2.2°- 55°
Power Consumption: 1100w
Power Voltage: AC 100-260V, 50/60Hz
Dimension:37*30.5*51cm
Package:(L*D*H):49*40*61cm
Net Weight:20.4 KG
Gross Weight: 26 KG
Control
DMX Channel:22/69/88 Channels
Art-Net mode : 57/76 channels
Control Modes: DMX512,Artnet protocol, RDM Pan/Tilt
Pan : 540°/ 630° ,Tiit : 270°
Pan/Tilt Resolution: 8/16 bit
Construction
Display:180° reversible LCD Display
Data In/Out socket: 3-pin & 5-pin XLR sockets Power
Socket: Powercon in
Bracket: Double brackets Protection Rating: IP20
Features
Dimmer:0~100% smooth dimming ;two dimmer model in optional( delay or without delay)
Outstanding color macro effect
Fast, quiet operation and flicker free
Led temperature protection & Fan run speed automatic based on the head temperature
LED single controlled, can display numbers, letters and arrows. Wonderful flower effect plus zoom

5
3. How To Control The Unit
The DMX512 is widely used in intelligent lighting control, with a DMX 512 controller. connect several lights
together, DMX in and DMX out, 3 pin XLR connectors: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal
(+)
Display:
MENU To select the programming functions
DOWN To go backward in the selected functions
UP To go forward in the selected functions
ENTER To confirm the selected functions
Set DMX Address Code
1. Press "Menu" to "Set DMX Address", and press "ENTER" key.
2. Show "Set DMX Address DMX Address:001",Press the "UP and DOWN" keys to amend.
3. Press "ENTER" key to save and Exit, Press the "MENU" Key to exit without saving
Address
Address 001~XXX
Set DMX
Address
Inf
DMX Value
ALL…
Display
DMX Value
Led
Temperature
XXXC/F
Fixture Hours
Current
Hours
Total Hours
Last Hours
Ethernet IP
X.X.X.X
IP Address

6
X.X.X.X
IP Mark
Software
Version
VX.X.X…
Software
Version
Option Config
Pan Tilt
Pan Reverse
ON/OFF
Tilt Reverse
ON/OFF
Pan-Degree
540/630
Encoder
ON/OFF
Pan Tilt
Speed 1~4
Speed
Service
Password
XXXX
Password
Code=123
RDM PID
0-131071
RDM PID
IP Address
Manual Set
Art-Net On
IP2
Art-Net On
IP10
IP Mask
X.X.X.X
IP Mask
Universe
OFF, 1-255
Art Universe
LED Address
1-512
LED Address
Source Select
DMX
Signal Select
DMX
Art-Net
Art
DMX&Art-Net
DMX and Art
Display
Shutoff
2-60 m
Reverse
ON/OFF
Lock On
ON/OFF
Temperature
Celsius
Fahrenheit
Reset Default
ON/OFF
Reset to
Factory
Default
Manual
Control
Manual
PAN
…..
White All
Password = XXX
…..
White All = XXX
Test Channel
PAN
…
White All
Calibration
Password
Password = XXX
PAN
PAN=XXX
TILT
Tilt=XXX
Reset
Reset All
Reset All Motors
DMX
Mode Set
Standard
Standard Mode
Shape RGB
Shape Mode With RGB
Shape RGBW
Shape Mode With RGBW

7
DMX&Net RGB
Shape Mode With RGB While DMX&Art-Net select
DMX&Net RGBW
Shape Mode With RGBW While DMX&Art-Net select
DMX : 22/69/88 channels
Art-Net : 57/76 channels
PS. Channels with shadow are controlled by Art-Net
Mode/Channel
Value
Function
Standard
Shape RGB
Shape RGBW
DMX&Net RGB
DMX&Net RGBW
1
1
1
controlled by DMX
1
1
PAN Movement 8bit :
0-255
Pan Movement
2
2
2
2
2
Pan Fine 16bit
0-255
Fine control of Pan movement
3
3
3
3
3
TILT Movement 8bit :
0-255
Tilt Movement
4
4
4
4
4
Tilt Fine 16bit
0-255
Fine control of Tilt movement
5
5
5
5
5
Speed Pan/Tilt movement:
0-225
max to min speed
226-255
no function
6
6
6
6
6
Strobe:
0-81
Led turn off
32-63
Led turn on
64-95
Strobe effect slow to fast
96-127
Led turn on
128-159
Pulse-effect in sequences
160-191
Led turn on
192-223
Random strobe effect slow to fast
224-255
Led turn on
7
7
7
7
7
Dimmer intensity:
0-255
Intensity 0 to 100%
8
8
8
8
8
Dimmer Mode:
0-20
Mode1
21-40
Mode2
41-60
Mode3
61-80
Mode4
81-100
Mode5
100-255
Mode1

8
9
9
9
9
9
LED Gamma:
0-59
Mode1
60-119
Dimmer 2.2
120-179
Dimmer 2.4
180-239
Dimmer 2.6
10
10
10
10
10
Zoom :
0-255
Zoom adjustment
11
11
11
11
11
Rotation:
0-127
0-60 positioning
128- 190
Zoom Rotation Forward min to max speed
191-192
Zoom Rotation Stop
193-255
Zoom Rotation Reverse min to max speed
12
Rainbow:
0-7
No function
8-39.
RED to YELLOW
40-71
YELLOW to GREEN
72-103
GREEN to CYAN
104-135
CYAN to BLUE
136-167
BLUE to MAGENTA
168-199
MAGENTA to RED
200-231
RED to WHITE
232-255
Crossfading colours from slow to fast
13
Color Presets:
0-4
No function
5--9
White1
10--14
White2
15-19
White3
20-24
White4
25-29
White5
30-34
White6
35-39
Color1
40-44
Color2
45-49
Color3
50-54
Color4
55-59
Color5
60-64
Color6
65-69
Color7
70-74
Color8
75-79
Color9
80-84
Color10
85-89
Color11
90-94
Color12
95-99
Color13
100-104
Color14
105-109
Color15

9
110-114
Color16
115-119
Color17
120-124
Color18
125-129
Color19
130-134
Color20
135-139
Color21
140-144
Color22
145-149
Color23
150-154
Color24
155-159
Color25
160-164
Color26
165-169
Color27
170-255
Reserved
14
Color Presets Dimmer:
0-255
Dimmer 100 to 0%
15
Chase Patterns:
1--14
Led trun off
15-30
Chase 1
31-46
Chase 2
47-62
Chase 3
63-78
Chase 4
79-94
Chase 5
95-110
Chase 6
111-126
Chase 7
127-142
Chase 8
143-158
Chase 9
159-174
Chase 10
175-190
Chase 11
191-206
Chase 12
207-222
Chase 13
223-238
Chase 14
239-255
Chase 15
16
Chase Speed:
0-125
Fast to Slow Backward
126-130
Stop(Speed=0)
131-255
Slow to Fast Forward
17
Chase Fade:
0-255
Fade Chase
18
Red LED -all arrays :
0-255
Red ( 0-Black , 255-100% Red )
19
Green LED-all arrays :
0-255
Green ( 0-Black , 255-100% Green )
20
Blue LED -all arrays :
0-255
Blue ( 0-Black , 255-100% Blue )
21
White LED -all arrays :

10
0-255
White ( 0-Black , 255-100% White )
22
12
12
12
12
Lamp on/off, reset, internal programs:
0-79
Normal
80-99
All motor reset
100-255
Normal
13
13
controlled by Art.-Net
1
Red LED -array 1 :
0-255
Red ( 0-Black , 255-100% Red )
14
14
2
2
Green LED-array 1
0-255
Green ( 0-Black , 255-100% Green )
14
15
3
3
Blue LED -array 1 :
0-255
Blue ( 0-Black , 255-100% Blue )
16
4
White LED -array 1 :
0-255
White ( 0-Black , 255-100% White )
16
17
4
5
Red LED -array 2 :
0-255
Red ( 0-Black , 255-100% Red )
17
18
5
6
Green LED-array 2
0-255
Green ( 0-Black , 255-100% Green )
18
19
6
7
Blue LED -array 2 :
0-255
Blue ( 0-Black , 255-100% Blue )
20
8
White LED -array 2 :
0-255
White ( 0-Black , 255-100% White )
19
21
7
9
Red LED -array 3 :
0-255
Red ( 0-Black , 255-100% Red )
20
22
8
10
Green LED-array 3
0-255
Green ( 0-Black , 255-100% Green )
21
23
9
11
Blue LED -array 3 :
0-255
Blue ( 0-Black , 255-100% Blue )
24
12
White LED -array 3:
0-255
White ( 0-Black , 255-100% White )
22
25
10
13
Red LED -array 4 :
0-255
Red ( 0-Black , 255-100% Red )
23
26
11
14
Green LED-array 4
0-255
Green ( 0-Black , 255-100% Green )
24
27
12
15
Blue LED -array 4 :
0-255
Blue ( 0-Black , 255-100% Blue )
28
16
White LED -array 4 :
0-255
White ( 0-Black , 255-100% White )
25
29
13
17
Red LED -array 5 :
0-255
Red ( 0-Black , 255-100% Red )
26
30
14
18
Green LED-array 5
0-255
Green ( 0-Black , 255-100% Green )
27
31
15
19
Blue LED -array 5 :
0-255
Blue ( 0-Black , 255-100% Blue )
32
20
White LED -array 5 :
0-255
White ( 0-Black , 255-100% White )

11
28
33
16
21
Red LED -array 6 :
0-255
Red ( 0-Black , 255-100% Red )
29
34
17
22
Green LED-array 6
0-255
Green ( 0-Black , 255-100% Green )
30
35
18
23
Blue LED -array 6 :
0-255
Blue ( 0-Black , 255-100% Blue )
36
24
White LED -array 6:
0-255
White ( 0-Black , 255-100% White )
31
37
19
25
Red LED -array 7 :
0-255
Red ( 0-Black , 255-100% Red )
32
38
20
26
Green LED-array 7 :
0-255
Green ( 0-Black , 255-100% Green )
33
39
21
27
Blue LED -array 7 :
0-255
Blue ( 0-Black , 255-100% Blue )
40
28
White LED -array 7:
White ( 0-Black, 255-100% White)
…
…
…
…
…
…
67
85
55
73
Red LED -array19 :
0-255
Red ( 0-Black , 255-100% Red )
68
86
56
74
Green LED-array 19
0-255
Green ( 0-Black , 255-100% Green )
69
87
57
75
Blue LED -array 19 :
0-255
Blue ( 0-Black , 255-100% Blue )
88
76
White LED -array 19:
0-255
White ( 0-Black, 255-100% White)
4. How to control Unit with Art-Net
1. Setting IP Address, choose Manual set to input IP address manually. You can also choose ON IP2 or ON
IP10 auto set.
2. IP Mask , input 255.0.0.0
3. Universe choose OFF or 1
4. Source select, input signal selection, there are three options:
DMX only →input signal is DMX
Art-Net → input Art-Net signal
DMX &Art-Net→Simultaneous input DMX & Art-Net signal
Notice:

12
If DMXonly or Art-Net are selected, only Standard or Shape RGB or ShapeRGBW channels modes can be
chosen. Then only DMX or Art-Net signal separately control Pan/Tilt, Dimmer and RGBW, etc.
If DMX&ArtNet is selected, it means simultaneous control by DMX and Art-Net, and Art-Net only control
RGBW Channels, DMX control others channels. Meantime channel modes DMX&ArtnetRGB or
DMX&NetRGBW can be chosen.
For example, if DMX & Artnet RGB CH Mode is chosen, CH 1 - CH13 are controlled by DMX, RGB matrix is
controlled by Art-Net.
5. When Art-Net or DMX & Art-Net are selected as an input signal, it means that Art-Net
controller will control the unit. But, Art-Net controller also need the same IP address,
IP MARK to be set.
Setting via menu
Information →Ethernet IP →select search fixture’s IP Address, IP MARK information.
5. Troubleshooting
There are a few common problems presented below, that may occur during operation. Here are
some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if they are linked properly.
2. If the DMX LED is on and no response to the channel, check the address settings and
DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on
PCB of the unit or the previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or alongside to high voltage cables that may
cause damage or interference to DMX interface circuit.
C. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor
’
s drive IC on the PCB might be out of condition.

13
6. Cleaning the device
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light
output. Cleaning frequency depends on the environment in which the unit operates: damp, smoky or particularly dirty
surrounding can cause greater accumulation of dirt on the unit’s optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Table of contents
Other Brighter Dj Equipment manuals

Brighter
Brighter Pixel Beam User manual

Brighter
Brighter LED PROFILE 150C User manual

Brighter
Brighter Smart Spot 330 Pro User manual

Brighter
Brighter LED PROFILE 180CTO User manual

Brighter
Brighter HexaPatt One User manual

Brighter
Brighter Magic Matrix User manual

Brighter
Brighter Double Blind User manual

Brighter
Brighter Eye 900 Pro User manual

Brighter
Brighter FW 100 User manual

Brighter
Brighter X-Dot User manual