Brivo ACS5000 User manual

!
!
ACS5000 Panel (A/E/S)
Installation Manual
Rev 1
ENG-DOC-003

ACS5000 Installation Manual Page 2
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
Legal Disclaimers
Federal Communications Commission (FCC) Compliancy
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation or when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Re-orient or relocate the receiving antenna (panels using cellular routers only).
• Increase the distance between the equipment and receiver.
• Connect the equipment to a circuit other than the one to which the receiver is connected.
• Consult the dealer for help.
Underwriter Laboratories (UL) Compliance
The ACS5000 complies with the UL 294 Standard for access control units with the following restrictions:
• The Ethernet port is for supplemental use only. The unit will continue to operate standalone if the
network connection is interrupted.
• The monitoring software is not UL evaluated.
Canada-Underwriters Laboratories (C-UL) Compliancy
For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the Canadian Electrical
Code.
Parts and Service
The ACS5000 control panel contains no user serviceable parts. The lithium battery is not serviceable and
is to be replaced by qualified service technicians only.
Documentation Disclaimer and Restrictions
Information in this document is subject to change without notice and does not represent a commitment on
the part of Brivo Systems LLC. For the most up-to-date information, visit www.brivo.com and click Dealer
Login to gain access to the Extranet.
This document and the data herein shall not be duplicated, used or disclosed to others for procurement or
manufacturing, except as authorized with the written permission of Brivo System LLC. The information
contained within this document or within the product itself is considered the exclusive property of Brivo
Systems LLC. All information in this document or within the hardware and software product themselves is
protected by the copyright and/or other intellectual property laws of the United States.
Activation of Services Agreement
Any use of this product is subject to the activation of the Brivo Systems LLC., Services Agreement. Please
request a copy from Brivo Systems LLC., and review this agreement carefully.
© 2017 Brivo Systems LLC. All rights reserved.
Brivo®is a registered trademark of Brivo Systems LLC. Brivo Systems LLC., 7700 Old Georgetown Road,
Suite 300, Bethesda, MD 20814

ACS5000 Installation Manual Page 3
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
Table of Contents
INTRODUCTION...........................................................................................................................................4
PRE-INSTALLATION PROCEDURES...........................................................................................................6
FOR ACS5000-E PANELS USING THE BRIVO CELLULAR NETWORK ROUTER ....................................12
GENERAL ASSEMBLY PROCEDURES .....................................................................................................13
POWERING AND TESTING PROCEDURES ..............................................................................................18
INSTALLATION PROCEDURES .................................................................................................................20

ACS5000 Installation Manual Page 4
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
Introduction
Document Objectives
This Installation Manual provides step-by-step instructions for installing the Brivo ACS5000 control panel. Its
primary audience is trained access control installation technicians (Installers) who are responsible for installing
the ACS5000 at client sites.
The manual is also intended for IT personnel, who should use it in conjunction with the Panel Networking
Admin Interface Guide. It may be used by dealers and their sales professionals to help them conduct pre-sales,
and to provide client support during the installation process. Finally, it may be used for in-house training
purposes and ongoing support.
Document Layout
This manual is organized into a series of procedural checklists, detailing steps you must follow to ensure a safe
and effective installation. The main sections of the manual are:
• Pre-Installation Procedures
• General Assembly Procedures
• Power and Testing Procedures
• Installation Procedures
Terminology
Following is a list of terms that are used throughout this document. While some of these terms may have other
meanings, the definitions provided below are the ones intended in this Installation Manual.
• Control chassis. The main chassis for a control panel. The control chassis contains the MAIN BOARD,
and may also contain one expansion board, either a DOOR BOARD or an INPUT OUTPUT BOARD (if
using a standard chassis) or three expansion boards in any combination of DOOR BOARDs or INPUT
OUTPUT BOARDs (if using a large chassis).
• Expansion chassis. Additional chassis, containing one or two expansion boards, either DOOR BOARDs
and/or INPUT OUTPUT BOARDs.
• Large expansion chassis. Additional chassis, containing up to four expansion boards, either DOOR
BOARDs and/or INPUT OUTPUT BOARDs.
• Control panel. The complete system of control chassis and expansion chassis for an account. A control
panel will have the MAIN BOARD (contained in the control chassis) and a number of additional
expansion chassis (standard or large) to hold a maximum of 14 additional DOOR BOARDs and/or
INPUT OUTPUT BOARDs (for a total maximum of 15 boards).
• Access control system (ACS). The complete interaction between a control panel, the Brivo product
(OnAir, OnSite, or OnSite Server) and in the case of Brivo OnAir, the Brivo OnAir cloud server.
• Brivo OnAir®. Brivo’s cloud based software application which enables the end user to manage his or
her Brivo OnAir account.
• Brivo OnAir Cloud Server. The off-site servers, hosted by Brivo, that are used to store an account’s
database. Configuration and maintenance of the control panel is managed through Brivo OnAir.
• Brivo OnSite. Brivo’s standalone software application which enables an end user to manage his or her
Brivo Onsite account.
• Brivo OnSite Server. Brivo’s appliance-based application which enables the end user to manage his or
her Brivo OnSite Server account.

ACS5000 Installation Manual Page 5
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
Wiring Recommendations
Signal
Belden # or
Equivalent
AWG
Twisted
Pair
Conductor
Shielded?
Max
Length
Power (22 gauge)
5504FE
22
Yes
Yes
600 ft
Power (18 gauge)
6300FE
18
Yes
Yes
1500 ft
RJ45-Ethernet (CAN Bus)
N/A
Cat5
Yes
Yes
1500 ft
Fire Alarm Relay
6300FE
18
Yes
Yes
1500 ft
Request-to-Exit
5520FE/6300FE
22/18
Yes
Yes
1500 ft
Door Contact
5500FE
22
Yes
Yes
1500 ft
Transformer Block
6300FE
18
Yes
Yes
1500 ft
Molex Connector
N/A
22
Yes
No
1 ft
Earth ground
N/A
6
Yes
Yes
20 to 40 ft
Reader Data 1
5504FE
22
Yes
Yes
250 ft
Reader Data 2
5400FE
20
Yes
Yes
300 ft
Reader Data 3
6300FE
18
Yes
Yes
500 ft
Additional Resources
The following additional resources are available for the installer as well as the client.
• Networking Admin Interface Guide
• Reader/Keypad Wiring Guide
• Installation Worksheet: Network
• Installation Worksheet: Door Board
• Installation Worksheet: Input Output Board
• Brivo OnAir Quick Start Guide
• Brivo Cellular Network Router Configuration Guide
• Brivo OnSite Quick Start Guide
• Brivo OnSite Server Quick Start Guide
• Technical Support: 1-866-BRIVO-4-U
• www.brivo.com

ACS5000 Installation Manual Page 6
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
Pre-Installation Procedures
Before you begin installing the Brivo control panel, perform the following tasks to ensure a safe, speedy, and
successful installation.
Understand the function of the Brivo ACS5000 control panel (A/E/S).
The ACS5000-E, ACS5000-A, and ACS5000-S are four (4) reader control panels with multiple access
points (up to four readers per chassis). This control panel is considered a standalone system. The
main board has two (2) readers on-board, and one additional expansion board can be integrated with
the main board which will form the four (4) reader panel. Additional expansion panels (ACS5000-EXP)
can connect to the main control panel with two expansion boards in each. Each expansion board can
be a door board (two (2) readers on board) or an input-output board.
The Brivo ACS5000-E uses an on-board Ethernet interface to communicate via any TCP/IP networking
technology that can be connected through a hub, router or switch, including Wi-Fi and satellite
communications. It is an IP-enabled Access Control System that interacts with the Brivo OnAir cloud
server via the Brivo OnAir application.
The Brivo ACS5000-A is identical to the ACS5000-E except that the ACS5000-A communicates to a
Brivo OnSite Server instead of the Brivo OnAir cloud server.
The Brivo ACS5000-S is identical to the ACS5000-E except that the ACS5000-S cannot communicate
through the web. Instead, it is programmed through an on-board interface for data management.
The ACS5008-E, ACS5008-A, and ACS5008-S are identical to their respective ACS5000 models except
for a larger enclosure which allows for two additional expansion boards (for a total of up to four door
boards and/or input-output boards). Also, the ACS5008 series are connected to two (2) 12V, 7Ah
batteries for standby power (Batteries should be connected in parallel).
For communications to remote sites or other locations not served by wired bandwidth technologies,
the Brivo ACS5000-E can be linked to a Brivo Cellular Network Router (CNR).
Because the ACS5000-E downloads all credential information and operating parameters from the
Brivo OnAir cloud server, it must be properly installed and configured through the Brivo OnAir cloud
server before it is fully functional.
WARNING:
CHECK YOUR FIRMWARE
Please contact Brivo Technical Support at 866-274-8648, option 3 or email
the latest firmware. If it is not, please follow the instructions provided by Brivo
Technical Support to upgrade your firmware to the latest version before
proceeding with the installation.
Understand Brivo ACS5000 product compatibility.
The ACS5000 control panel is compatible with a large number of standard reader models including
the following (UL tested for compatibility) reader models: Essex KTP162, Essex KTP163, HID 5355,
HID 5365, HID 6005, HID 310, AWID KP-6840, and BIOSCRYPT VSmart. Brivo products are designed
to accommodate the latest updates in Wiegand formats. The ACS5000 control board is compatible
with Wiegand devices that transmit up to 255-bit data.
A current list of compatible readers and keypads is maintained on Brivo’s website at
http://www.brivo.com. If you have a specific model of reader or keypad that is not listed on the Brivo
website, please contact Technical Support at 1-866-BRIVO-4-U to determine compatibility.

ACS5000 Installation Manual Page 7
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
Verify that the client site is ready to support the installation.
1. Check with the IT department to ensure that the ACS5000 to be installed is compatible with
the company’s local area network (LAN).
a) The ACS5000 is equipped with a standard RJ-45 socket that accepts a CAT5 cable
with an RJ-45 plug on any 10/100 Ethernet network. Physically connecting the panel
is the same as plugging any computer or other device into the LAN.
b) Refer to the Panel Networking Admin Interface Guide (or the Brivo OnSite
Administrator’s Manual in the case of the ACS5000-S) for instructions on connecting
to the LAN. The Panel Networking Admin Interface Guide (or Brivo OnSite
Administrator’s Manual) also contains a complete list of requirements regarding
TCP/IP configuration parameters, firewall and proxy settings, and information about
security considerations.
2. Download the appropriate Quick Start Guide from the Brivo website and provide it to the
Master Administrator. This document provides instructions for registering and configuring the
control panel in the appropriate application.
3. For Brivo OnAir accounts, make sure the account has been created and the control panel is
registered through Brivo OnAir. If the control panel has not been registered by the dealer, the
installer may either contact Brivo Technical Support for assistance or simply register the panel
directly.
4. Verify that the Master Administrator and any other employee who will be accessing the system
have Internet access on a computer equipped with a supported Web browser.
Verify shipping contents.
1. Locate and check the contents of the Control Panel kit.
The ACS5000 kit should contain the following parts:
a) 1 metal chassis (MCH-CHA-0001). Packed inside the chassis are:
• An identify label (ENG-LBL-0001) to be adhered to the inside of the door.
• 1 cardboard box containing the MAIN BOARD (B-ACS5000) (#1181-01-
0101A) and an Identity Label (#ENG-LBL-0004).
• 1 cardboard box containing a power supply board (#1181-01-0104A).
• 1 cardboard box containing accessories, including:
o 1 AC transformer (#ELC-XFM-AMS1)
o 1 7 Ah lead-acid battery (#ELC-BAT-B7001)
o 1 power cable assembly (#ELC-PWR-A001)
o 2 MOVs (Metal Oxide Varistors), (#ELC-MOV-M001)
o 16 EOL (End of Line) resistors (#ELC-EOL-R001)
o 2 10-inch 18-gauge battery wires (1 red, 1 black), with female
spade-type connectors (#ELC-BAT-W001)
o 1 AC Power Indicator LED (ELC-LED-L001).
b) 1 lock and key set (#MCH-LCK-0001)
c) 5 screws for power supply (#MCH-SCW-0001)
d) 5 standoffs for the MAIN BOARD (#MCH-SFF-0001)

ACS5000 Installation Manual Page 8
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
e) 1 tamper switch assembly (#ELC-TMP-A001)
f) 1 documentation set, including:
• Installation Manual (this document)
5. If additional DOOR BOARDs have been ordered with the control panel, locate and check the
contents of each 2-Door Board Kit (B-ACS5000-DB). There may be up to 14 of these kits (for a
total of 15 including the MAIN BOARD) and each should contain the following parts:
a) 1 DOOR BOARD (#1181-01-0102A).
b) 5 standoffs for the DOOR BOARD (#MCH-SFF-0001)
c) 6 EOL resistors (#ELC-EOL-R001)
d) 2 MOVs (Metal Oxide Varistors) (#ELC-MOV-M001)
e) 1 power cable assembly (#ELC-PWR-A001)
6. If additional INPUT OUTPUT BOARDs have been ordered with the control panel, locate and
check the contents of each INPUT OUTPUT BOARD Kit (B-ACS5000-IO).There may be up to 14
of these kits (for a total of 15 including the MAIN BOARD), and each should contain the
following parts.
a) 1 INPUT OUTPUT BOARD (#1181-01-0103A).
b) 5 standoffs for the INPUT OUTPUT BOARD (#MCH-SFF-0001)
c) 8 EOL resistors (#ELC-EOL-R001)
d) 1 power cable assembly (#ELC-PWR-A001)
7. If additional expansion chassis have been ordered with the control panel, locate and check
the contents of each Expansion Chassis Kit (B-ACS5000-EXP) or Large Expansion Chassis Kit
(B-ACS5008-EXP). Each standard expansion chassis can hold up to two boards, including any
combination of door and/or Input Output boards. Each large expansion chassis can hold up to
four boards, including any combination of door and/or Input Output boards. There may be
enough Expansion Chassis kits or Large Expansion Chassis Kits to hold 1 MAIN BOARD, and
any combination of 14 door and/or Input Output boards. Each should contain the following
parts:
a) 1 metal chassis (MCH-CHA-0001)
b) 1 lock and key set (#MCH-LCK-0001)
c) 5 screws for power supply (#MCH-SCW-0001)
d) 1 door label showing wiring and setup guide (Inside Door Label – Expansion (#ENG-
LBL-0003)
e) 1 tamper switch assembly (#ELC-TMP-A001), containing a tamper switch (ELC-TMP-
S001), wire (ELC-TMP-W001, and header connector (ELC-TMP-HC01)
f) 1 power supply board (#1181-01-0104A).
g) 1 AC transformer (#ELC-XFM-AMS1)
h) 1 pair of battery wires (#ELC-BAT-W001)
i) 1 AC Power Indicator LED (ELC-LED-L001), pre-installed in the chassis door.
j) 1 7 Ah lead-acid battery (#ELC-BAT-B7001)
Plan your installation.
1. Determine the size of your control panel.

ACS5000 Installation Manual Page 9
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
k) In addition to the control chassis, which contains the MAIN BOARD, there may be up
to seven expansion chassis (or four large expansions chassis).
l) The control chassis contains the MAIN BOARD, which also serves as a 2-door board,
and may also contain either a DOOR BOARD or an INPUT OUTPUT BOARD. If a large
chassis is used, the control chassis may contact any combination of 3 additional door
and/or Input Output boards.
m) Each expansion chassis may contain any combination of up to 2 door and/or Input
Output boards. Each large expansion chassis may contact any combination of 4 door
and/or Input Output boards.
• Each DOOR BOARD has two terminal nodes, each of which contains a
complete set of terminals for controlling a door. This means that each DOOR
BOARD can be used to control two doors.
• The same inputs and outputs that drive a door can also be used for other
devices as configured through Brivo Online. In other words, DOOR BOARDs
do not need to be used to control doors.
WARNING: Door Wiring
If a node is to be used for a door, do not connect any other device to the
following terminal blocks: REX & DOOR, DOOR LOCK RELAY, and READER.
• An INPUT OUTPUT BOARD cannot be used to control a door; however, it can
be used in any circumstance that uses contact closure to track change of
status.
8. You may download and complete the appropriate Installation Worksheets from Brivo’s
website.
9.
For ACS5000-E control panels using the Brivo Cellular Network Router only
: If possible, verify
the strength of the signal at the planned location of the Cellular Network Router.
Decide where to install each chassis.
1. Do not place the control chassis more than 100 feet from the transformer. This is the
maximum cable run allowed by the ACS power supply.
2. Calculate the distance between the control chassis and each expansion chassis using the
chart in Table 1 below. The calculations are based on the following restrictions.
a) The control chassis, containing the MAIN BOARD, and the first expansion chassis can
be up to 1500 feet apart.
b) Each time another expansion chassis is added, the maximum distance between the
first and last chassis decreases by 50 feet. So, if there are three chassis in a system,
the control chassis plus two expansion chassis, the two most distant chassis can be
no more than 1450 apart.

ACS5000 Installation Manual Page 10
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
Total # of chassis
Max allowed distance
2
1500
3
1450
4
1400
5
1350
6
1300
7
1250
8
1200
Table 1. Maximum Distance Calculations
c) Calculate the distance between each chassis and its associated keypad or reader.
The ACS5000 does not specify a maximum distance between the chassis and a
keypad or reader, but the keypad/reader manufacturer does. Follow manufacturer
guidelines for each keypad and reader.
d) Place each chassis within 500 feet of its associated electronic strike or latch.

ACS5000 Installation Manual Page 11
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
Follow safety precautions.
WARNING: Fire Code
NEVER CONNECT A KEYPAD/READER OR LOCK TO DOORS WITHOUT FIRST
CONSULTING THE APPLICABLE FIRE CODE. You must consult with, and get
approval from, local fire officials before installing locks or devices on any
doors that may be fire exits. Use of egress push buttons may not be legal.
Single action exits may be required. Always obtain proper permits and
approvals in writing before installing equipment
WARNING: Fail Secure Mode
DO NOT INSTALL THE SYSTEM IN THE FAIL SECURE MODE UNLESS
PERMITTED BY THE LOCAL AUTHORITY HAVING JURISDICTION. Doing so
may cause interference with the operation of panic hardware.
WARNING: Heat and Noise
DO NOT INSTALL THE CONTROL PANEL IN AN AREA THAT COULD DROP
BELOW 32 DEGRESS FAHRENHEIT OR EXCEED 120 DEGREES. Doing so
can cause damage to components within the control panel.
DO NOT INSTALL THE CONTROL PANEL NEAR OR ON THE SAME CIRCUIT
WITH DEVICES THAT PRODUCE LARGE AMOUNTS OF ELECTRICAL NOISE.
This includes grinders, electric motors and blowers, electrical switch-gear
and other electrically noisy equipment. Electrical noise can interfere with
panel operation. If it is not possible to install the panel away from such
sources of noise, it is advisable to isolate it by using a high-quality UPS
(Uninterruptible Power Supply) between the AC Mains and the transformer.
• Wiring methods should be in accordance with the National Electrical Code, ANSI/NFPA 70.
• Category 5 cabling is the minimum performance category recommended.
• If powered by 12VDC, the power supply must be a UL294 listed power supply.

ACS5000 Installation Manual Page 12
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
For ACS5000-E Panels using the Brivo Cellular Network Router
NOTE:
Please refer to the Brivo CNR Configuration Guide on the Brivo website
(http://www.brivo.com/wp-content/uploads/2015/01/S-Brivo-CNR-
Configuration-Guide.pdf) for step-by-step instructions on the configuration of
the Brivo CNR with the ACS5000-E panel.
WARNING:
Cable Connectors
THE CONNECTORS ON THE INTERNAL ANTENNA CABLE ARE VERY FRAGILE.
Be very careful when plugging in the equipment.
WARNING:
Attach antenna before powering the Brivo CNR.
NEVER POWER UP A BRIVO CNR BEFORE CONNECTING THE ANTENNA.
WARNING:
FCC RF Exposure
NO ONE SHOULD BE WITHIN 20cm (8 inches) OF THE ANTENNA WHEN IT IS
TRANSMITTING, as per the FCC RF exposure requirements for mobile
transmitter end products using the Galtronics, O dBd antenna.

ACS5000 Installation Manual Page 13
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
General Assembly Procedures
Assemble and mount chassis.
1. Stick the identity label (ENG-LBL-0001) to the inside of the metal chassis.
2. Install the supplied nylon stand-offs into each chassis by inserting them from the rear.
NOTE:
This step MUST be performed before the chassis is mounted to the wall. Once
the chassis has been mounted, it is not possible to insert the stand-offs.
a) There are five stand-offs for each board, but there are more holes than that in the
chassis.
b) Determine which holes you will use based on the size of the boards you are installing.
3. Mount the chassis.
a) Use four bolts to mount each chassis securely in place.
b) Make sure the chassis door can swing open freely to allow for access after the
installation is complete.
4. Remove any knock-outs that may be required to accommodate conduit or wiring.
WARNING: Knockouts
DO NOT ATTEMPT TO REMOVE THE KNOCKOUTS WITH A HAMMER. Banging on
the knockouts may result in shock to the circuit boards, which could cause
permanent damage. Pry them out using a screwdriver.
5. Assemble the chassis.
a) Install the power supply board in each chassis first. If you install the MAIN BOARD or
a Door or INPUT OUTPUT BOARD first, you may find it difficult to position your
screwdriver in a way that will allow you to install the power supply board later.
b) Install the MAIN BOARD in the control chassis.
• Install each board by aligning it with the previously installed stand-offs and
then gently pressing it into place. You will hear a slight click as the board
settles into the locked position on the standoffs
c) If there is a DOOR BOARD or an INPUT OUTPUT BOARD for the control chassis, install
that now, using the procedures described for the MAIN BOARD.
d) If there are expansion chassis, install the appropriate DOOR BOARDs and/or INPUT
OUTPUT BOARDs in each chassis at this time, using the procedures described for the
MAIN BOARD.
e) You will note that the control panel kit contained an adhesive Identity Label. This
label should be affixed to the inside of the front door of the control chassis, beneath
the large wiring guide.
6. Install the tamper switch in each chassis.
a) Install the tamper switch in each chassis by removing the hex collar, seating the
switch inside the provided mounting bracket, and reattaching and tightening the hex
collar.

ACS5000 Installation Manual Page 14
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
Connect the MAIN BOARD and all expansion boards to a power supply board
1. Connect the MAIN BOARD in the control chassis to the power supply board.
Figure 1. Connect MAIN BOARD to Power Supply
2. If there is a DOOR BOARD or an INPUT OUTPUT BOARD in the control chassis, connect that to
the power supply board.
Figure 2. Connect Expansion Board to Power Supply
3. If there are expansion chassis, connect each DOOR BOARD and INPUT OUTPUT BOARD to the
power supply board in each chassis.
a) Use the power cable that came with each circuit board kit.
b) The Power connector uses a PC-style 4-wire molded (Molex) connector to deliver
+12V, Ground, AC, Power Detection, and Earth Ground to each board from the power
supply.
WARNING: Power Supply
DO NOT USE ANY POWER SUPPLY OTHER THAN THOSE SUPPLIED WITH YOUR
BRIVO PRODUCT.

ACS5000 Installation Manual Page 15
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
WARNING: Powering Electronic Strikes and Latches
DO NOT POWER ELECTRONIC STRIKES AND LATCHES WITH THE BATTERY (OR
OTHER POWER SOURCE) USED TO POWER THE CONTROL PANEL; DOING SO
WILL CAUSE DAMAGE TO THE BRIVO CONTROL PANEL. USE ONLY A UL LISTED
BURGLAR ALARM OR ACCESS CONTROL SYSTEM TO POWER ELECTRONIC
STRIKES AND LATCHES.
Connect the AC Power Indicator LED for each chassis to the power supply for that
chassis.
1. Mount the AC power indicated LED on the front door of the chassis by pushing it through the
hold in the upper left corner of the door and securing using the bolt and washer included with
your packaging.
2. Connect the white and green wires from the AC power indicated LED to the 16.5 VAC
terminals of the power supply board.
Connect the tamper switch to the MAIN BOARD and to one board in each expansion
chassis.
1. Connect the tamper switch to the MAIN BOARD in the control chassis.
Figure 3. Connect Tamper Switch to MAIN BOARD
a) The tamper header connects to the supplied tamper switch.
b) The header connector for the tamper switch should be connected to the TAMPER
pins located on the lower right side of the MAIN BOARD and each expansion board.
2. Connect the tamper switch to one expansion board (DOOR BOARD or INPUT OUTPUT BOARD)
in each expansion chassis.
Figure 4. Connect Tamper Switch to Expansion Board
NOTE:
If a chassis has two or more boards, connect the tamper switch to the upper
board.

ACS5000 Installation Manual Page 16
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
NOTE:
If the tamper switch is not going to be used, leave the supplied jumper on the
connector to keep the circuit closed.
Connect the battery leads to the power supply
WARNING: Backup Battery
DO NOT CONNECT THE BACK-UP BATTERY AT THIS TIME. Premature connection
of the battery terminals may cause damage to the control panel.
1. Connect the battery wires (#ELC-BAT-W001) that come with each circuit board kit to the
power supply BATTERY INPUT terminal block.
a) Connect the black wire to the ground (GND) terminal.
b) Connect the red wire to the +12V terminal.
Figure 5. Connect Battery Leads to Power Supply
Wire the AC transformer to the power supply
WARNING: Transform Connection
DO NOT CONNECT THE TRANSFORMER TO A SWITCHED OUTLET OR
OTHERWISE CONTROLLED AC OUTLET.
DO NOT CONNECT THE TRANSFORMER TO THE 120 VAC OUTLET UNTIL ALL
WIRING IS COMPLETED.

ACS5000 Installation Manual Page 17
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
1. Use 18 AWG wire (minimum grade) to connect the screw terminals on the transformer to the
16.5 VAC POWER INPUT terminal block on the power supply board, using terminals AC1 and
AC2.
Figure 6. Connect AC Transformer to Power Supply

ACS5000 Installation Manual Page 18
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
Powering and Testing Procedures
WARNING: Power Precautions
BEFORE POWERING UP THE CONTROL PANEL, CHECK THE FOLLOWING
CONNECTIONS. MAKE SURE THAT:
• The transformer is NOT plugged into the 120 VAC outlet.
• All wiring to the back-up battery is DISCONNECTED.
Power up the control panel.
1. Plug the transformer into a 120 VAC outlet.
2. Check ALL power indicators:
a) Check the power supply board to confirm that the green LED is on and blinking,
indicating that AC power is being supplied to the board and that the board is
producing 12 VDC power.
b) Check the MAIN BOARD to confirm that the LOCAL HRTBT (local heartbeat) and MAIN
HRTBT (main heartbeat) have come on and are blinking.
• The local heartbeat should begin blinking immediately.
• The main heartbeat can take 30-60 seconds to establish a steady beat.
Figure 7. MAIN BOARD Heartbeats
c)
For ACS5000-E control panels using a Brivo Cellular Network Router
, make sure the
Brivo Cellular Network Router is powered when connecting it to the MAIN BOARD.

ACS5000 Installation Manual Page 19
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
d) Check each DOOR BOARD to confirm that the LOCAL HRTBT has come on and is
blinking, indicating that 12 VDC power is present.
Figure 8. Expansion Board Local Heartbeat
e) Check each INPUT OUTPUT BOARD to confirm the LOCAL HRTBT has come on and is
blinking.
f) If any of these power indicators is not correct (i.e., the LED light does not come on or
does not begin blinking, check the connections from the power supply to each of the
circuit boards. If all connections are good but there is a still a problem with the power
indicator, contact Technical Support.
NOTE:
A steady light is an indication of a problem, just as much as no light is.
3. If ALL power indicators are correct, attach the back-up battery and check that ALL indicators
remain the same. Only then should you go on to Installation Procedures.

ACS5000 Installation Manual Page 20
© 2017 Brivo Systems LLC. All rights reserved. Rev 1
Installation Procedures
Establish CAN BUS Wiring
1. If there is an expansion board in the control chassis, connect it to the MAIN BOARD.
Figure 9. Connect Expansion Board to MAIN BOARD
2. When dealing with expansion chassis, connect the second expansion board to the first one in
each expansion chassis.
This manual suits for next models
3
Table of contents
Other Brivo Control Panel manuals
Popular Control Panel manuals by other brands

Jackson Systems
Jackson Systems Comfort System Z-300-HP Wiring diagram

Sony
Sony RCP-1500 Operation guide

Sonetonix
Sonetonix CS-BP8-B user manual

Behringer
Behringer ULTRAPATCH PRO PX2000 user manual

Honeywell
Honeywell MM3-MASTERTROL MM-3 Schematics document

Haes
Haes AlarmSense Installation, commissioning & operating manual