Brivo ACS6000 User manual

BRIVO ACS6000
INSTALLATION MANUAL
8/15/2017

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
2
Legal Disclaimers
Federal Communications Commission (FCC) Compliancy
You are cautioned that changes or modifications not expressly approved by the part responsible for compliance
could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation or when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
•Re-orient or relocate the receiving antenna.
•Increase the distance between the equipment and receiver.
•Connect the equipment into an outlet on a circuit other than the one to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference and
2. This device must accept any interference received, including interference that may cause undesired
operation of the device.
FCC RF Radiation Exposure Statement
1. This transmitter must not be co-located or operate in conjunction with any other antenna or transmitter.
2. This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of 20
centimeters between the radiator and your body.
Underwriter Laboratories (UL) Compliance
The ACS6000 complies with the UL 294 Standard for access control units with the following restrictions:
•The Ethernet port is for supplemental use only. The unit will continue to operate standalone if the
network connection is interrupted.
•The monitoring software is not UL evaluated.
Canada-Underwriters Laboratories (C-UL) Compliancy (CSA C22.2 No. 205)
For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the Canadian Electrical Code.
UL294 Performance Levels
Model Number
Access Control Line
Security Level
Destructive Attack
Level
Endurance Level
Stand-by Power
Level
Conditions
Brivo ACS6000 and
ACS6008 Level I Level I Level IV Level I N/A
Parts and Service
The ACS6000 control panel contains no user serviceable parts. The lithium battery is not serviceable and is to be
replaced by qualified service technicians only.

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
3
Documentation Disclaimer and Restrictions
Information in this document is subject to change without notice and does not represent a commitment on the
part of Brivo Systems LLC. For the most up-to-date information, visit www.brivo.com.
This document and the data herein shall not be duplicated, used or disclosed to others for procurement or
manufacturing, except as authorized with the written permission of Brivo Systems LLC. The information contained
within this document or within the product itself is considered the exclusive property of Brivo Systems LLC. All
information in this document or within the hardware and software product themselves is protected by the
copyright and/or other intellectual property laws of the United States.
Product Support
All support for this product is provided by the third-party dealer. Please contact the dealer who installed the
product with questions and support requests.
© 2017 Brivo Systems LLC. All rights reserved.
Brivo®is a trademark of Brivo Systems LLC. Brivo Systems LLC., 7700 Old Georgetown Road, Suite 300, Bethesda,
MD 20814

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
4
Table of Contents
INTRODUCTION .............................................................................................................................................................5
PRE-INSTALLATION PROCEDURES..................................................................................................................................7
GENERAL ASSEMBLY PROCEDURES .............................................................................................................................13
INSTALLATION PROCEDURES .......................................................................................................................................22
POWERING AND TESTING PROCEDURES .....................................................................................................................37
CONFIGURATION PROCEDURES...................................................................................................................................39

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
5
Introduction
Document Objectives
This Installation Manual provides step-by-step instructions for installing the Brivo ACS6000 Control Panel. Its
primary audience is trained access control installation technicians (Installers) who are responsible for installing the
ACS6000 Control Panel at client sites.
This version of the manual is also intended for IT personnel, who should use it in conjunction with the Brivo Panel
Networking Admin Interface Guide. It may be used by dealers and their sales professionals to help them conduct
pre-sales, and to provide client support during the installation process. Finally, it may be used for in-house training
purposes and ongoing support.
Document Layout
This manual is organized into a series of procedural checklists, detailing steps you must follow to ensure a safe and
effective installation. The main sections of the manual are:
•Pre-Installation Procedures
•General Assembly Procedures
•Installation Procedures
•Powering and Testing Procedures
•Configuration Procedures
Terminology
Following is a list of terms that are used throughout this document. While some of these terms may have other
meanings, the definitions provided below are the ones intended in this Installation Manual.
•Control chassis. The main chassis for a control panel. The control chassis contains the MAIN BOARD,
POWER SUPPLY BOARD (PSB) and may also contain one expansion board, either a DOOR BOARD or an
INPUT OUTPUT BOARD (if using a standard chassis) or three expansion boards in any combination of
DOOR BOARDs or INPUT OUTPUT BOARDs (if using a large chassis).
•Expansion chassis. Additional chassis, containing POWER SUPPLY BOARD and one or two expansion
boards, either DOOR BOARDs and/or INPUT OUTPUT BOARDs.
•Large expansion chassis. Additional chassis, containing POWER SUPPLY BOARD and up to four expansion
boards, either DOOR BOARDs and/or INPUT OUTPUT BOARDs.
•Control panel. The complete system of control chassis and expansion chassis for an account. A control
panel will have the MAIN BOARD (contained in the control chassis) and a number of additional expansion
chassis (standard or large) to hold a maximum of 14 additional DOOR BOARDs and/or INPUT OUTPUT
BOARDs (for a total maximum of 15 boards).
•Access control system (ACS). The complete interaction between a control panel, the Brivo product (Onair
or Onsite Server) and in the case of Brivo Onair, the Brivo Onair cloud server.
•Brivo Onair®. Brivo’s cloud based software application which enables the end user to manage his or her
Brivo Onair account.
•Brivo Onair Cloud Server. The off-site servers, hosted by Brivo, that are used to store an account’s
database. Configuration and maintenance of the control panel is managed through Brivo Onair.
•Brivo Onsite Server. Brivo’s appliance-based application which enables the end user to manage his or her
Brivo Onsite Server account.

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
6
Wiring Recommendations
Signal
Belden # or
Equivalent
AWG
Twisted
Pair
Conductor
Shielded?
Max Length
RS-485 Comm, two wire
9841
24
Yes
Yes
4000 ft
Power (22 gauge)
5504FE
22
Yes
Yes
600 ft
Power (18 gauge)
6300FE
18
Yes
Yes
1500 ft
RJ45-Ethernet
N/A
Cat5
Yes
Yes
1500 ft
CAN Bus
N/A
Cat 5
Yes
Yes
1500 ft
Fire Alarm Relay
6300FE
18
Yes
Yes
1500 ft
Request-to-Exit
5520FE/6300FE
22/18
Yes
Yes
1500 ft
Door Contact
5500FE
22
Yes
Yes
1500 ft
Transformer Block
6300FE
18
Yes
Yes
100 ft
Molex Connector
N/A
22
Yes
No
1 ft
Earth ground
N/A
6
Yes
Yes
20 to 40 ft
Reader Option 1 (22 AWG)
5504FE
22
Yes
Yes
250 ft
Reader Option 2 (20 AWG)
5400FE
20
Yes
Yes
300 ft
Reader Option 3 (18 AWG)
6300FE
18
Yes
Yes
500 ft
Additional Resources
The following additional resources are available for the installer as well as the client.
•Panel Networking Admin Interface Guide
•Reader/Keypad Wiring Guide
•Installation Worksheet: Network
•Installation Worksheet: Door Board
•Installation Worksheet: Input Output Board
•Brivo Onair Quick Start Guide
•Brivo Cellular Network Router Configuration Guide
•Brivo Onsite Server Quick Start Guide
•Technical Support: 1-866-BRIVO-4-U
•www.brivo.com

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
7
Pre-Installation Procedures
Before you begin installing the Brivo control panel, perform the following tasks to ensure a safe, speedy, and
successful installation.
Understand the function of the Brivo ACS6000 control panel.
The ACS6000-E and ACS6000-A are four (4) reader control panels with multiple access points (up to four
readers per chassis). This control panel is considered a standalone system. The main board has two (2)
readers on-board, and one additional expansion board can be integrated with the main board which will
form the four (4) reader panel. Additional expansion panels (ACS6000-EXP) can connect to the main
control panel with two expansion boards in each. Each expansion board can be a door board (two (2)
readers on board) or an input-output board.
The Brivo ACS6000-E uses an on-board Ethernet interface to communicate via any TCP/IP networking
technology that can be connected through a hub, router or switch, including Wi-Fi and satellite
communications. It is an IP-enabled Access Control System that interacts with the Brivo Onair cloud server
via the Internet application Brivo Onair.
The Brivo ACS6000-A is identical to the ACS6000-E except that the ACS6000-A communicates to a Brivo
Onsite Server instead of the Brivo Onair cloud server.
The ACS6008-E and ACS6008-A are identical to their respective ACS6000 models except for a larger
enclosure which allows for two additional expansion boards (door board or input-output boards). Also,
the ACS6008 series are connected to two (2) 12V, 7Ah batteries for standby power (Batteries should be
connected in parallel).
Understand Brivo ACS6000 control panel product compatibility.
The ACS6000 control panel is compatible with a large number of standard reader models including the
following (UL tested for compatibility) reader models: HID600, Identiv 8110, HID RPK40, Allegion MTK15,
AWID KP-6840, and OSDP reader 921PTPTEK00385. Brivo products are designed to accommodate the
latest updates in Wiegand and OSDP using RS-485 reader formats. The ACS6000 control board is
compatible with Wiegand devices that transmit up to 255-bit data and OSDP readers using RS-485.
A current list of compatible readers and keypads is maintained on Brivo’s website at
http://www.brivo.com. If you have a specific model of reader or keypad that is not listed on the Brivo
website, please contact Technical Support at 1-866-BRIVO-4-U to determine compatibility.
Verify that the client site is ready to support the installation.
1. Check with the IT department to ensure that the ACS6000 control panel to be installed is
compatible with the company’s local area network (LAN).
a) The ACS6000 control panel is equipped with a standard RJ-45 socket that accepts a CAT5
or CAT6 cable with an RJ-45 plug on any 10/100 Ethernet network. Physically connecting
the panel is the same as plugging any computer or other device into the LAN.
b) Refer to the Panel Networking Admin Interface Guide for instructions on connecting to
the LAN. The Panel Networking Admin Interface Guide also contains a complete list of
requirements regarding TCP/IP configuration parameters and information about
security considerations.
2. Download the appropriate Quick Start Guide from the Brivo website and provide it to the Master
Administrator. This document provides instructions for registering and configuring the control
panel in the appropriate application.
3. For Brivo Onair accounts, make sure the account has been created and the control panel is
registered through Brivo Onair. If the control panel has not been registered by the dealer, the

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
8
installer may either contact Brivo Technical Support for assistance or simply register the panel
directly.
4. Verify that the Master Administrator and any other employee who will be accessing the system
have Internet access on a computer equipped with a supported Web browser.
Verify shipping contents.
1. Locate and check the contents of the Control Panel kit.
The ACS6000 control panel kit (B-ACS6000-MB) should contain the following parts:
a) 1 metal chassis. Packed inside the chassis are:
oAn identify label to be adhered to the inside of the door.
o1 cardboard box containing the MAIN BOARD and main board accessories.
o1 MAIN BOARD
o1 anti-static bubble wrap bag
o1 MAIN BOARD Accessory Kit
1 zipper bag
2 metal oxide varistors
16 2k ¼W 5% resistors
5 ACS6000 style standoffs
5 ACS5000 style standoffs
1 dipole antenna – 2dB (Wi-Fi antenna)
1 IPEX cable (Wi-Fi cable)
1 earth ground screw
1 4P power wire harness
o1 identity label
o1 cardboard box containing a power supply board (PSB) and PSB accessories.
o1 power supply board
o1 anti-static bubble wrap bag
o1 power supply board accessories kit
1 zipper bag
4 screws
o1 identity label
b) 1 cardboard box containing accessories, including:
•1 AC transformer
•1 7Ah lead-acid battery (x2 for ACS6008)
c) 1 lock and key set
d) 1 documentation set, including:
•Installation Manual (this document)

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
9
2. If additional DOOR BOARDs have been ordered with the control panel, locate and check the
contents of each 2-Door Board (B-ACS6000-DB) Kit. There may be up to 15 of these kits, and each
should contain the following parts:
a) 1 DOOR BOARD
b) 1 anti-static bubble wrap bag
c) 1 DOOR BOARD Accessory Kit
•1 zipper bag
•2 metal oxide varistors
•16 2k ¼W resistors
•5 standoffs for the DOOR BOARD
•1 4P Power wire harness
d) 1 identity label
3. If additional INPUT OUTPUT BOARDs have been ordered with the control panel, locate and check
the contents of each INPUT OUTPUT BOARD (B-ACS6000-IO) Kit. There may be up to 15 of these
kits, and each should contain the following parts.
a) 1 INPUT OUTPUT BOARD
b) 1 anti-static bubble wrap bag
c) 1 INPUT OUTPUT BOARD Accessory Kit
•1 zipper bag
•2 metal oxide varistors
•16 2k ¼W resistors
•5 standoffs for the INPUT OUTPUT BOARD
•1 4P power wire harness
d) 1 identity label
4. If additional expansion chassis have been ordered with the control panel, locate and check the
contents of each Expansion Chassis Kit (B-ACS6000-EXP) or Large Expansion Chassis Kit (B-
ACS6008-EXP). Each standard expansion chassis can hold up to two boards, including any
combination of door and/or Input Output boards. Each large expansion chassis can hold up to
four boards, including any combination of door and/or Input Output boards. There may be
enough Expansion Chassis kits or Large Expansion Chassis Kits to hold 1 MAIN BOARD, and any
combination of 14 door and/or Input Output boards. Each should contain the following parts:
a) 1 metal chassis
•1 lid
•1 box
•1 hinge pair short
•1 hinge pair long
b) 1 lock and key set
c) An identify label to be adhered to the inside of the door

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
10
d) Battery and PSU cardboard box
•1 power supply board
•1 pair of battery wires
•1 AC transformer
•1 7Ah lead-acid battery (x2 for ACS6008)
Plan your installation.
1. Determine the size of your control panel.
a. In addition to the control chassis, which contains the MAIN BOARD, there may be up to
seven expansion chassis.
b. The control chassis contains the MAIN BOARD, which also serves as a 2-door board, and
may also contain either a DOOR BOARD or an INPUT OUTPUT BOARD.
c. Each standard expansion chassis (ACS6000) may contain up to two boards, in any
combination of DOOR BOARDs and/or INPUT OUTPUT BOARDs.
•Each DOOR BOARD has two terminal nodes, each of which contains a complete set
of terminals for controlling a door. This means that each DOOR BOARD can be used
to control two doors.
•The same inputs and outputs that drive a door can also be used for other devices. In
other words, DOOR BOARDs do not need to be used to control doors.
WARNING: Door Wiring
If a node is to be used for a door, do not connect any other device to the following
terminal blocks: REX & DOOR, DOOR LOCK RELAY, and READER.
•An INPUT OUTPUT BOARD cannot be used to control a door; however, it can be
used in any circumstance that uses contact closure to track change of status.
d. Each large expansion chassis (ACS6008) may contain up to four boards, in any
combination of DOOR BOARDs and/or INPUT OUTPUT BOARDs.
•Each DOOR BOARD has two terminal nodes, each of which contains a complete set
of terminals for controlling a door. This means that each DOOR BOARD can be used
to control two doors.
•The same inputs and outputs that drive a door can also be used for other devices. In
other words, DOOR BOARDs do not need to be used to control doors.
WARNING: Door Wiring
If a node is to be used for a door, do not connect any other device to the following
terminal blocks: REX & DOOR, DOOR LOCK RELAY, and READER.
•An INPUT OUTPUT BOARD cannot be used to control a door; however, it can be
used in any circumstance that uses contact closure to track change of status.
2. Using the packing slip as a guide, complete the appropriate Installation Worksheets included with
your documentation set.

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
11
Decide where to install each chassis.
1. Do not place the control chassis more than 100 feet from the transformer. This is the maximum
cable run allowed by the ACS power supply.
2. Calculate the distance between the control chassis and each expansion chassis using the chart in
Table 1 below. The calculations are based on the following restrictions.
a) The control chassis, containing the MAIN BOARD, and the first expansion chassis can be
up to 1500 feet apart.
b) Each time another expansion chassis is added, the maximum distance between the first
and last chassis decreases by 50 feet. So, if there are three chassis in a system, the
control chassis plus two expansion chassis, the two most distant chassis can be no more
than 1450 apart.
Total # of chassis
Max allowed distance
2
1500
3
1450
4
1400
5
1350
6
1300
7
1250
8
1200
Maximum Distance Calculations
c) Calculate the distance between each chassis and its associated keypad or reader. The
ACS6000 does not specify a maximum distance between the chassis and a keypad or
reader, but the keypad/reader manufacturer does. Follow manufacturer guidelines for
each keypad and reader.
d) Place each chassis within 500 feet of its associated electronic strike or latch.
Follow safety precautions.
WARNING: Fire Code
NEVER CONNECT A KEYPAD/READER OR LOCK TO DOORS WITHOUT FIRST
CONSULTING THE APPLICABLE FIRE CODE. You must consult with, and get approval
from, local fire officials before installing locks or devices on any doors that may be
fire exits. Use of egress push buttons may not be legal. Single action exits may be
required. Always obtain proper permits and approvals in writing before installing
equipment
WARNING: Fail Secure Mode
DO NOT INSTALL THE SYSTEM IN THE FAIL SECURE MODE UNLESS PERMITTED BY
THE LOCAL AUTHORITY HAVING JURISDICTION. Doing so may cause interference
with the operation of panic hardware.

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
12
WARNING: Heat and Noise
DO NOT INSTALL THE CONTROL PANEL IN AN AREA THAT COULD DROP BELOW 32
DEGRESS FAHRENHEIT OR EXCEED 120 DEGREES FAHRENHEIT.Doing so can cause
damage to components within the control panel.
DO NOT INSTALL THE CONTROL PANEL NEAR OR ON THE SAME CIRCUIT WITH
DEVICES THAT PRODUCE LARGE AMOUNTS OF ELECTRICAL NOISE. This includes
grinders, electric motors and blowers, electrical switch-gear and other electrically
noisy equipment. Electrical noise can interfere with panel operation. If it is not
possible to install the panel away from such sources of noise, it is advisable to
isolate it by using a high-quality UPS (Uninterruptible Power Supply) between the
AC Mains and the transformer.

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
13
General Assembly Procedures
Assemble and mount chassis.
1. Stick the identity label to the inside of the metal chassis.
2. Install the supplied nylon stand-offs into each chassis by inserting them from the rear.
NOTE: This step MUST be performed before the chassis is mounted to the wall.
Once the chassis has been mounted, it is not possible to insert the stand-offs.
a) For the MAIN BOARD, there are 5 standoffs and 1 screw for the ground post, but there
are more holes than that in the chassis.
b) For DOOR BOARDs and INPUT OUTPUT BOARDs, there are five stand-offs for each
board, but there are more holes than that in the chassis.
c) Determine which holes you will use based on the size of the boards you are installing.
3. Mount the chassis.
a) Use four bolts to mount each chassis securely in place.
b) Make sure the chassis door can swing open freely to allow for access after the
installation is complete.
c) In tight spaces, the removable hinge design of the ACS6000/ACS6008 enclosures allow
an installer to completely remove the chassis door and replace it just as easily upon
completion of the installation.
4. Remove any knock-outs that may be required to accommodate conduit or wiring.
WARNING: Knockouts
DO NOT ATTEMPT TO REMOVE THE KNOCKOUTS WITH A HAMMER. Banging on
the knockouts may result in shock to the circuit boards, which could cause
permanent damage. Pry them out using a screwdriver.
5. Assemble the chassis.
a) Install the power supply board in each chassis first. If you install the MAIN BOARD or a
Door or INPUT OUTPUT BOARD first, you may find it difficult to position your
screwdriver in a way that will allow you to install the power supply board later.
b) Install the MAIN BOARD in the control chassis.
•Install each board by aligning it with the previously installed stand-offs and
then gently pressing it into place. You will hear a slight click as the board
settles into the locked position on the standoffs.
•After that, screw on the ground post screw on the bottom left corner.
c) If there is a DOOR BOARD or an INPUT OUTPUT BOARD for the control chassis, install
that now, using the procedures described for the MAIN BOARD.

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
14
d) If there are expansion chassis, install the appropriate DOOR BOARDs and/or INPUT
OUTPUT BOARDs in each chassis at this time, using the procedures described for the
MAIN BOARD.
e) You will note that the control panel kit contained an adhesive Identity Label. This label
should be affixed to the inside of the front door of the control chassis, beneath the large
wiring guide.
6. Verify presence of optical tamper reflector on the inside of the chassis door.
7. OPTIONAL: Install the physical tamper switch in the chassis.
a) Install the tamper switch in the chassis by removing the hex collar, seating the switch
inside the provided mounting bracket, and reattaching and tightening the hex collar.

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
15
Switch SW 7 setting description
Figure 1 - ACS6000 SW 7 Switch Bank Location
Figure 2 - ACS6000 SW 7 Switch Settings

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
16
Switch Setting
Description
Functionality Description
SW 7-1
Tamper
Enabled: Tamper functionality is in use
Disabled: Tamper functionality is not in use
SW 7-2
CAN Bus
Enabled: CAN Bus is terminated
Disabled: CAN Bus is not terminated
SW 7-3
SW 7-4
Maintenance Mode
For general operation, SW 7-4 needs to be in the Off position.
SW 7-5
SW 7-6
Factory Reset
How to perform factory reset:
•Ensure that SW 7-6 is in the OFF position.
•Power off MAIN BOARD.
•Place SW 7-6 dip switch in the ON position
•Power on the board and wait until you hear two two-second
long beeps and see the main heartbeat LED turn off.
•Within 10 seconds of hearing the beeps, place SW 7-6 dip
switch back into the OFF position.
•You will hear a one second-long beep and the main
heartbeat LED will start blinking again indicating the system
is performing a factory reset.
•After the factory reset is complete, you will hear 2 short
beeps.
•At this point, the factory reset is complete the system will
now run with factory default firmware.
SW 7-7
SW 7-8
Wi-Fi
Enabled: Wi-Fi can be used if configured.
Disabled: Wi-Fi cannot be used at all, even if configured.

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
17
Connect the MAIN BOARD and all expansion boards to a power supply board
1. Connect the MAIN BOARD in the control chassis to the power supply board.
Figure 3 - Connect MAIN BOARD to Power Supply
2. If there is a DOOR BOARD or an INPUT OUTPUT BOARD in the control chassis, connect that to the
power supply board.
Figure 4 - Connect Expansion Board to Power Supply
3. If there are expansion chassis, connect each DOOR BOARD and INPUT OUTPUT BOARD to the
power supply board in each chassis.
a) Use the power cable that came with each circuit board kit.
b) The Power connector uses a PC-style 4-wire molded (Molex) connector to deliver +12V,
Ground, Power Detection, and Earth Ground to each board from the power supply.
WARNING: Power Supply
DO NOT USE ANY POWER SUPPLY OTHER THAN THOSE SUPPLIED WITH YOUR
BRIVO PRODUCT.

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
18
WARNING: Powering Electronic Strikes and Latches
DO NOT POWER ELECTRONIC STRIKES AND LATCHES WITH THE BATTERY (OR
OTHER POWER SOURCE) USED TO POWER THE CONTROL PANEL; DOING SO WILL
CAUSE DAMAGE TO THE BRIVO CONTROL PANEL. USE ONLY A UL LISTED
BURGLAR ALARM OR ACCESS CONTROL SYSTEM TO POWER ELECTRONIC STRIKES
AND LATCHES.
The ACS6000 control panel Tamper On/Off Toggle in the off position deactivates both optical
and physical tamper switches.
Figure 5 - Tamper Switch and Optical Tamper Sensor Locations
NOTE: If the technician is installing the ACS6000 MAIN BOARD as a retrofit in an
ACS5000 enclosure, there is no optical reflector present. The optical tamper will
not function.
OPTIONAL: Connect the physical tamper switch to the MAIN BOARD and to one board in each
expansion chassis.
1. Connect the physical tamper switch to the MAIN BOARD in the control chassis.

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
19
Figure 6 - Connect Tamper Switch to MAIN BOARD
a) The tamper header connects to the supplied tamper switch.
b) The header connector for the tamper switch should be connected to the TAMPER pins
located on the lower right side of the MAIN BOARD and each expansion board.
2. Connect the tamper switch to one expansion board (DOOR BOARD or INPUT OUTPUT BOARD) in
each expansion chassis.
Figure 7 - Connect Tamper Switch to Expansion Board
NOTE: If a chassis has two boards, connect the tamper switch to the upper board.
NOTE: If the tamper switch is not going to be used, leave the supplied jumper on
this connector to keep the circuit closed.
Connect the battery leads to the power supply
WARNING: Backup Battery
DO NOT CONNECT THE BACK-UP BATTERY AT THIS TIME. Premature connection of
the battery terminals may cause damage to the control panel.

Brivo ACS6000 Installation Manual
© 2017 Brivo Systems LLC. All rights reserved. P-MAN-PUB-ACS6000 Installation Manual
20
1. Connect the battery wires that come with each circuit board kit to the power supply BATTERY
INPUT terminal block.
a) Connect the black wire to the ground (GND) terminal.
b) Connect the red wire to the +12V terminal.
c) Make sure the battery wires are segregated at least ¼ inch away from all other
input/output wiring.
NOTE: Power Standby Level 1 for UL listed systems.
Figure 8 - Connect Battery Leads to Power Supply
Other manuals for ACS6000
1
Table of contents
Other Brivo Control Panel manuals
Popular Control Panel manuals by other brands

Beninca
Beninca CP.BISON OTI manual

Savch
Savch SC-3000 Series user manual

Zehnder Rittling
Zehnder Rittling ComfoTouch XL QuickGuide Installation

Mitsubishi
Mitsubishi GOT1000 Series user manual

ELECTRONIC ASSEMBLY
ELECTRONIC ASSEMBLY EA KIT129-6 manual

BSS Audio
BSS Audio Soundweb London BLU-6 installation guide