Structural Diagram
Installation Process
Parameter Table
Airflow Adjustment
1. Confirm the installation location
2. Drill the fresh air hole. The external
opening should be 5~10mm lower
than the internal opening to prevent
rain penetration
3. Install the fresh air pipe and the water
shield
4. Fill the gap between the air pipe and
the wall hole with polyurethane, and
keep it sealed
5. Drill 5 holes for the retaining bolts as
per the mounting plate and the fresh
air pipe
6. Knock the rubber plugs into the retaining
bolt holes and screw down the bolts
7. Hang the machine on the mounting plate
M6x60 self-tapping screw
with Φ8x60 expandable
rubber plug
hole Φ8x60
Φ168
hole for
air pipe
The bottom of
the fresh air hole
must be aligned
at the arced
bottom of the
shell for drainage
fresh air in
fresh air out
unit: mm
The fan or the circuit board is broken
Button failure
The outlet
grille is stained
The fan
doesn't work
The power plug is loose and has
poor connection
The button is stuck or the wire
is broken
Repair or replace it
The HEPA filter is blocked
Clean with a towel (to prevent
water from entering the fan)
The polluted air flows back (if
the filter is faulty, there is likely
dirt in the fan)
· Power switch
Level 1 (blue light): Suitable for sleep
Level 2 (green light): Suitable for room
Level 3 (yellow light): High air volume (Note
the AirPro will be more audible at this setting)
Filter Replacement
(operate after powering off)
Maintenance
· Design life: 20 years (the bearing may need
to be replaced during this period)
- Recommended maintenance:
1. Wash the coarse filter every month;
2. Replace the HEPA filter every four months;
3. Check the filtration efficiency and
ventilation effect regularly
- Service:4100-833-9333
- Web:www.broadair.net
· When the air volume is less than 70%,
the HEPA filter needs to be replaced
· Coarse filter washing: hold the machine
upwards 4mm to remove it from the wall,
take out the stainless steel coarse filter
from the back of the machine to wash, dry
and re-install. The coarse filter should be
cleaned after 500 hours of use, or every
half a month in heavily polluted areas
· HEPA filter replacement: remove the
machine from the wall, take out the
stainless steel coarse filter first, and then
the HEPA filter for replacement. The HEPA
filter should be replaced after 3,000 hours
of use. When installing the HEPA filter, the
arrow direction should be inward.
FE5
Name: AirPro Simple
Model:
Serial Number:
Date of Purchase:
Shop:
Inspector:
Seller:
Quality Certificate/ Warranty Card
Warranty
· 1-year warranty from the date of purchase.
For problems caused by design, manufac-
turing or transportation from factory, free
repair or replacement will be provided
· If the user is unable to provide a valid proof
of purchase, the warranty period should be
extended by 3 months according to the
production date shown on the unit
· If the AirPro was damaged due to inappro-
priate use or storage, or the sticker was torn
off, there will be a charge for repair
Filtration