Basin mounted electronic tap for cold or premixed water.
POWER SUPPLY: 6 X 1.5V AA / 240V-9V TRANSFORMER
MINIMUM WATER PRESSURE: 200KPA
MAXIMUM WATER PRESSURE: 500KPA IN ACCORDANCE WITH AS3500
SECURITY SHUT OFF: 90 SECONDS DEFAULT
HOT WATER TEMPERATURE: MAX 70˚C
ADJUSTABLE FLOW TIME: 3-12 SECONDS
ADJUSTABLE SENSOR RANGE: 80MM - 170MM
Failure to do so will void warranty.
AVOID REFLECTION ISSUES
• The sensor eye must be installed no closer than 300mm to any adjacent surface.
• Do not install the unit with the sensor eye above a plug/waste in a basin or sink.
•
• Do not install the sensor facing a mirror or any other system operated by an infra-red sensor.
•
WATER SUPPLY
•
line before the solenoid valve. Flush water supply lines thoroughly before installing the solenoid.
with Australian Standards AS3500. Failure to do so will void warranty.
• These units are not suitable for gravity feed systems.
CORRECT SOAP VISCOSITY
• Ensure that the correct soap is selected for the Brosmart Sensor Soap Dispensers. A soap with
SERVICE ACCESS
• Install the transformers and solenoids in a serviceable location (either behind a nearby service
•
• Brodware have extension leads if required (sold separately). Do not cut or make your own. Doing
so will void warranty.
SENSOR ADJUSTMENT
•
sold separately) for both the Brosmart Sensor Taps and Brosmart Sensor Soap Dispensers. If you
do not have one on site when installing, please contact you supplier.
If there are any issues with complying with any other above, please contact Brodware before
proceeding on 1300 800 300 or service@brodware.com.
TECHNICAL DATA PRE-INSTALLATION INFORMATION
POWER SUPPLY: BATTERY OR 9V TRANSFORMER
MINIMUM WATER PRESSURE: 200KPA
MAXIMUM WATER PRESSURE: 500KPA IN ACCORDANCE WITH AS3500
SECURITY SHUT OFF: 90 SECONDS
HOT WATER TEMPERATURE: MAX 70˚C
ADJUSTABLE FLOW TIME: 3-12 SECONDS
ADJUSTABLE SENSOR RANGE: 20-250MM
3 4