Brodware 2.2705.00 Operating and safety instructions

SUITABLE FOR 2.2705.00, 2.2705.02, 2.2705.20, 2.2705.22, 2.2705.30,
2.2705.70, 2.2706.00, 2.2706.02, 2.2706.20, 2.2706.22, 2.2706.30,
2.2706.70, 2.2706.94 2.2702.90 & 2.2702.92
ELECTRONIC SENSOR TAP
INSTALLATION & MAINTENANCE GUIDE

THANKYOU FOR YOUR PURCHASE OF
A SENSOR BASIN SET FROM BRODWARE
To ensure correct operation of the wall set for years
to come, please carefully read and understand the
following installation and maintenance instructions before
commencing the installation of your sensor wall set.
After reading this manual, if you still have any questions
about the installation process or correct maintainance
of the sensor wall set, please call us on +61 1300 800 300
or email us at technicalsupport@brodware.com
TECHNICAL DATA
PRE-INSTALLATION INFO
INSTALLATION GUIDES
SETTINGS ADJUSTMENT
MAINTENANCE
WARRANTY
TROUBLESHOOTING
SPARE PARTS
CONTENTS
031.
042.
053.
15
17
19
18
19
4.
5.
7.
6.
8.
1 2

Basin mounted electronic tap for cold or premixed water.
POWER SUPPLY: 6 X 1.5V AA / 240V-9V TRANSFORMER
MINIMUM WATER PRESSURE: 200KPA
MAXIMUM WATER PRESSURE: 500KPA IN ACCORDANCE WITH AS3500
SECURITY SHUT OFF: 90 SECONDS DEFAULT
HOT WATER TEMPERATURE: MAX 70˚C
ADJUSTABLE FLOW TIME: 3-12 SECONDS
ADJUSTABLE SENSOR RANGE: 80MM - 170MM
Failure to do so will void warranty.
AVOID REFLECTION ISSUES
• The sensor eye must be installed no closer than 300mm to any adjacent surface.
• Do not install the unit with the sensor eye above a plug/waste in a basin or sink.
•
• Do not install the sensor facing a mirror or any other system operated by an infra-red sensor.
•
WATER SUPPLY
•
line before the solenoid valve. Flush water supply lines thoroughly before installing the solenoid.
with Australian Standards AS3500. Failure to do so will void warranty.
• These units are not suitable for gravity feed systems.
CORRECT SOAP VISCOSITY
• Ensure that the correct soap is selected for the Brosmart Sensor Soap Dispensers. A soap with
SERVICE ACCESS
• Install the transformers and solenoids in a serviceable location (either behind a nearby service
•
• Brodware have extension leads if required (sold separately). Do not cut or make your own. Doing
so will void warranty.
SENSOR ADJUSTMENT
•
sold separately) for both the Brosmart Sensor Taps and Brosmart Sensor Soap Dispensers. If you
do not have one on site when installing, please contact you supplier.
If there are any issues with complying with any other above, please contact Brodware before
proceeding on 1300 800 300 or service@brodware.com.
TECHNICAL DATA PRE-INSTALLATION INFORMATION
POWER SUPPLY: BATTERY OR 9V TRANSFORMER
MINIMUM WATER PRESSURE: 200KPA
MAXIMUM WATER PRESSURE: 500KPA IN ACCORDANCE WITH AS3500
SECURITY SHUT OFF: 90 SECONDS
HOT WATER TEMPERATURE: MAX 70˚C
ADJUSTABLE FLOW TIME: 3-12 SECONDS
ADJUSTABLE SENSOR RANGE: 20-250MM
3 4

OUTLET AND SENSOR INSTALLATION GUIDE
FOR 2.2705.00, 2.2705.20, 2.2706.00 AND
2.2706.20 MODELS
MIXER INSTALLATION:
sensor facing a mirror or any other system operated by an infra-red sensor.
on the drawing for correct positioning). Screw the outlet into position to the thread.
5. Feed the leads from the transformer and the solenoid through from the rear of the Sensor Mounting
Tube with the grub screw from the underside of the sensor face. If there is a gap between the
Tube accordingly.
6. Turn on the water and power supply, and test for functionality. Adjustments to the sensor range and
any set up queries, please refer to the troubleshooting section in the back of this booklet.
Note: If there is not enough length in either lead, do not cut or make your own lead. Modifying or
making your own lead will void warranty. Brodware have extension leads to suit (part numbers are in
NOTE: Use 32mm conduit to conceal wiring.
5 6

INSTALLATION GUIDE FOR 2.2702.90 & 2.2702.92
MIXER INSTALLATION:
1. Shut off water supply.
not to remove o-ring seal from the trim. It must be there to seal the mixer to the
bench top.
3. Screw the braided hose into the bottom of the mixer.
4. Fit the mixer with the trim to the bench top.
5. Refit the mounting plate and fixing but to the underside of the mixer. Do the nut up
finger tight. Ensure the tap is aligned and in the correct position.
6. Secure the tap by tightening the fixing nut using a wrench or a spanner.
CONTINUE TO PAGE 13 FOR FOLLOWING INSTRUCTIONS TO COMPLETE THE INSTALLATION
OF YOUR BRODWARE SENSOR TAP
7 8

STEP ONE:
1. Shut off water supply.
install
the sensor facing a mirror or any other system operated by an infra-red sensor.
dimensions on the drawing for correct positioning).
4. Below the male thread, a cut out of 50mm x 80mm is required in the wall to recess the
sensor and sensor mounting bracket. This is to be 110mm from centre of male thread, to
centre of the sensor eye.
5. Feed the leads from the transformer and from the solenoid from inside the wall cavity
connection, 1x female connection).
6. Run a thin bead of silicone sealant on the inside face of the cover plate to seal the unit to
male thread, and screw the outlet to the male thread.
separately). If there are any set up queries, please refer to the troubleshooting section in
the back of this booklet.
or making your own lead will void warranty. Brodware have extension leads to suit (part
place your order.
CONTINUE TO PAGE 13 FOR FOLLOWING INSTRUCTIONS TO COMPLETE THE INSTALLATION
OF YOUR BRODWARE SENSOR TAP
OUTLET AND SENSOR INSTALLATION GUIDE FOR
2.2705.02, 2705.22, 2.2706.02 AND 2.2706.22
910

STEP ONE:
1. Shut off water supply.
install the sensor facing a mirror or any other system operated by an infra-red sensor.
location/position. (Refer to the dimensions on the drawing for correct positioning).
4. Below the male thread, a cut out of 50mm x 80mm is required in the wall to recess the
sensor and sensor mounting bracket. This is to be 110mm from centre of male thread,
to centre of the sensor eye.
5. Feed the leads from the transformer and from the solenoid from inside the wall cavity
connection, 1x female connection).
6. Trial fit the spout nipple by screwing the spout nipple through the cover plate, and into the
back of the spout and cover plate, measure the gap and cut down themale thread on the
nipple to the desired length. Apply thread sealant or thread tape to the male thread of the
spout nipple, and screw the spout nipple into the female fitting in the wall.
9. Turn on the water and power supply, and test for functionality. Adjustments to the sensor
range and run time are done by using the appropriate remote control (sold separately).
If there are any set up queries, please refer to the troubleshooting section in the back
of this booklet.
or making your own lead will void warranty. Brodware have extension leads to suit (part
place your order.
CONTINUE TO PAGE 13 FOR FOLLOWING INSTRUCTIONS TO COMPLETE THE INSTALLATION
OF YOUR BRODWARE SENSOR TAP
OUTLET AND SENSOR INSTALLATION GUIDE FOR
2.2705.70 AND 2706.70
11 12

STEP TWO - CONNECTING THE WATER SUPPLY:
The solenoid valve is installed into the water connection to the outlet spout. This must be
accessible for servicing. An access panel in the wall under the outlet is a widely used option.
Observe the flow direction through the valve and ensure that no Teflon tape, copper filings,
before the valve.
The water supply is provided via normal plumbing practices, either cold or pre-mixed warm, using
a thermostatic mixing valve, plumbed to the solenoid, then to the outlet.
OUTLET AND SENSOR INSTALLATION GUIDE FOR ALL
MODELS (CONTINUED)
STEP THREE - CONNECTING THE POWER SOURCE:
1. Connect the cable coming from the electronic sensor unit or the solenoid valve connector.
connector (battery box or transformer).
sided adhesive foam tape. The cable connection must point down. (You can use
an optional extension cable in order to assemble the battery box up to 3m away from the
solenoid.)
transformer into the electricity wall socket and connect the connectors. Once secure,
plug and socket or quick connects, the unit and all of the interconnections should be
installed into a water-proof enclosure.
hand through the beam to turn the water on, and again to turn the water off.
d) If the automatically adjusted sensor range is not satisfactory to your purposes, please
refer to the section entitled “Settings Adjustment”.
13 14

STEP ONE - CONNECTING THE WATER SUPPLY:
1. Shut off water supply.
the water supply pipe and the mounting base, where you want to install the spout.
3. Cut two small holes for the mounting base support and drive the anchors in.
4. Remove the outlet and trim ring from the mounting base, by removing the securing grub
screw from the underside of the outlet.
5. Mount the mounting base with the support through the opening, and secure the base
support to the two holes using two screws.
wall falls between the min and max lines marked on the base.
6. Connect the water supply pipe from outlet side of the solenoid body to the inlet
connection on the mounting base.
8. Feed the wires through the cable sleeve
9. Connect the electronic unit’s connections coming out from the mounting base to the
solenoid and power supply connectors.
10. Fit the trim ring and outlet to the mounting base on the wall. Secure the unit with the grub
screw to the underside of the outlet.
OUTLET AND SENSOR INSTALLATION GUIDE
FOR 2.2706.94
15 16

•
compatible product model. The remote control is sold separately.
ADJUSTING THE SETTINGS WITH THE REMOTE CONTROL
• Connect the cable coming from the electronic sensor unit or the solenoid valve connector.
•
• Shut off the water supply. In order to adjust the sensor with the remote control, hold the
• Choose the function you want to adjust by pressing once on one of the function buttons.
After pressing once on a specific function button, a quick flashing of the red light at the
front of the sensor will occur. At this stage, you can change the setting by pressing the (+)
or the (-) buttons, every press will increase or decrease one unit.
• After finishing the adjustment, turn the water supply back on.
SETTINGS ADJUSTMENT
DETECTION RANGE
eye is visible. Then, press + to increase the range and – to reduce it.
distance is retained by the sensor, even if the power source is disconnected.
ENTRANCE TO THE SELF ADJUSTMENT MODE
flashing of the red light of the sensor eye is visible, remove the remote control and
move away from the sensor area. The ideal sensor range for the specific location
will be set automatically. Once the self adjustment has taken place the solenoid
valve will open for about 1 second as an indication that the ideal sensor range was
set and the product is ready for use.
SECURITY TIME
The Security time, prevents continuous running of water due to reflections or
vandalism. By default, if the sensor is covered for more than 90 seconds the water
flow will shut automatically.
To resume regular operation any obstruction must be removed.
visible. Then, press + to increase the security time and – to reduce it.
DELAY OUT TIME
This allows the adjustment of the flow time after the users hands have been
removed from the sensors range. A shorter delay out time will save more water.
A longer delay out time will assist in ease of use.
press + to increase the delay out time and – to reduce it.
17 18

BATTERY MODELS ONLY
must be replaced.
TO REPLACE THE BATTERY ON BATTERY MODELS:
1. Carefully open the battery box.
3. Replace the used batteries with 6x AA batteries. (Lithium batteries are recommended).
4. Close the box.
CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
The Brodware product you have purchased has been designed to provide many years of
dependable service. However, the finish, as on all plumbing products, requires care to be
taken to retard the wear that will eventually occur.
pure soap liquid to remove stains and water spots.
such as Mr Sheen™, which is helpful in preventing water spots on all finishes.
the atmosphere, will regain their shine by polishing with Brasso™ or Autosol™.
• Due to impurities in most water supplies, a regular cleaning of aerators is recommended.
• Ensure in line filter is cleaned or replaced on a regular basis.
ALL WORK MUST BE CARRIED OUT BY A LICENSED PLUMBER
MAINTENANCE TROUBLESHOOTING
PROBLEM INDICATOR CAUSE SOLUTION
N O WAT E R
FLOW Sensor flashes
continuously when
user’s hands are
within the sensor’s
range.
Low battery Replace with 6 new
batteries.
Sensor does not
flash when user’s
hands are within
the sensor’s range
Range is too short Increase the range
using the remote
control
Range is too long Decrease the range
using the remote
control
Battery is completely used up Replace battery
See footnotes
Sensor is picking up reflections from
the washbasin or another object
Remove/eliminate
the cause.
Red light in the
sensor flashes
when user’s hands
are within range.
Connections between the
between the tap and solenoid are
disconnected
Connect the
solenoid to the tap.
Debris or scale in solenoid Replace the
solenoid.
Reduce the water
supply pressure
yet the pressure in the taps body
is higher. This could be caused by
a sudden increase in the water
supply pressure that the back chock
prevents from dropping, even after
Shut off water
supply and unscrew
the flexible pipes in
order to reduce the
pressure.
WAT E R
FLOW FROM
SPOUT
D O E S
N O T
STOP
Sensor flashes
when user’s hands
are within range.
Debris or scale in diaphragm Clean the orifice
or replace the
diaphragm
Red light in the
sensor does not
flash when user’s
hands are within
the sensor’s range
Clean or eliminate
cause of
interference
Sensor is picking up reflections from
the washbasin or another object.
Decrease the range
or eliminate cause
of reflection
WAT E R
F L O W I S
DIMINISHED
Filter or aerator is clogged Remove, Clean,
Re-Install
flow. To return to normal operation remove obstruction.
19 20

LIMITED WARRANTY
SPARE PARTS
THIS PRODUCT IS COVERED BY A LIMITED WARRANTY OF TWO YEARS FROM DATE
OF PURCHASE.
During this period, Brodware undertakes, at its option, to repair or replace any faults caused by
This guarantee does not cover faults or damage cause by incorrect installation and/or
maintenance, wear and tear, battery, or water composition. This includes, but is not limited to
• Improper manipulation, tampering, bad or lapsed maintenance.
• Foreign bodies, dirt or scale introduced by the water supply.
2. 2702.TF.0.00: BROSMART TRANSFORMER
2.2705.SF.0.00: BROSMART ROUND FRONT FIX SENSOR
2.2705.SP.0.00: BROSMART OVAL SENSOR - PROXIMITY ACTIVATION
2.2702.SO.0.00: BROSMART SOLENOID VALVE ONLY
2.2705.BD.0.01: BROSMART SOLENOID VALVE AND IN-WALL BODY
2.2702.EL.0.00: BROSMART SENSOR EXTENSION LEAD - 2M
2.2752.PU.0.00: BROSMART SOAP PUMP
2.2752.EX.0.00: BROSMART SOAP PUMP EXTENSION KIT
C27.02.RM: BROSMART REMOTE CONTROL FOR SENSOR TAPWARE
2.2752.RM.0.00: BROSMART REMOTE CONTROL FOR SOAP DISPENSER
MAINTENANCE NOTES
21 22

ICSEN 210509
This manual suits for next models
14
Table of contents