2www.bromic.com
MAINTENANCE:
If the power cord is damaged in any way, it must be replaced immediately by a service
agent or suitably qualified person.
TIP REPLACEMENT & DRESSING:
Note: Tip replacement or cleaning should only be done when the iron is at room
temperature. The tip can be changed or replaced by unscrewing the knurled nut barrel
assembly. It is essential that the iron is switched o and allowed to cool before and after
this operation, as damage may result if the iron is left on without the tip inserted. After
removing the tip, blow out any remaining oxide dust that may have formed in the tip
retaining area of the barrel. Care should be taken to avoid getting dust in your eyes.
Replace the tip and tighten the knurled nut barrel assembly using only hand pressure.
Pliers should only be used to tighten the nut if loosening occurs when the iron is hot.
Care should be taken not to over tighten the nut, as this may damage the element.
GENERAL CLEANING:
The iron may be cleaned with a damp cloth using small amounts of liquid detergent.
Never submerse the iron in liquid or allow any liquid to penetrate the case.
KEEP OUT OF REACH OF CHILDREN
POWER SUPPLY:
240V AC
Output: 25W, 40W or 80W*
Cable Length: 1.35m
Applications:
20W and 40W (ceramic heat element): Radio controls, hobbies and crafts, small electrical parts
80W model (*Mica heat element): Household electrical appliances, capacitors and heavy-duty
soldering applications requiring more heating power.
APPROVAL:
SAA-151950-EA approval for Electrical Equipment (25W and 40W)
AS/NZS 60335.2.45:2012; AS/NZS 60335.1:2011 standards
SAA-151950-EA approval for Electrical Equipment (80W)
AS/NZS 60335.2.45:2012; AS/NZS 60335.1:2011 standards