4-1. OUTPUT check
1. ▽key (1) + Power ON
⇒PROGRAM No. display (2) = check code
⇒menu display (3) = abbreviated output name
2. Press the or key (5) to check the operations for check codes 51 - 54.
3. For check code 55 and after, depress the foot switch to the 2nd step.
4. When returning to normal operation, turn power off and then on again.
When you press the key, the work clamps move to the left.
When you press the key, the work clamps move to the right.
When you press the key, the work clamps move forward.
When you press the key, the work clamps move back.
When you press the key, the work clamps rise.
When you press the key, the work clamps drop.
When you press the key, the thread nipper moves toward the home
position.
When you press the key, the thread nipper moves toward the retract
position.
The valve for the right work clamp turns on (*)
The valve for the left work clamp turns on (*)
The valve for the stepping foot turns on (*)
The valve for the inner clamping device turns on. (*)
The valve for the needle cooler turns on. (*)
The LEDs on the panel illuminate in sequence, and then each of the seven
segments of the PROGRAM No. display and menu display illuminate.
The thread trimmer solenoid turns on.
The tension release solenoid turns on.
The external wiper solenoid turns on.(*)