MATRON-Light with 2250-M Field Guide, Page 12
a) Recording Control has been set for activation by the MATRON-3 hand-
switch.
b) The has been set to meaning that we are recording sound
signals in the frequency range up to about 6.6kHz. Other recording frequency ranges and
their meanings are given in the following table.
Approximate sound recording times
corresponding to Memory card sizes:
Recording
Quality
description
Approximate
frequency
range for
sound
recording
(kHz)
Sampl-
ing
speed:
(kHz)
Memory
usage
(audio
signals
only):
KB/s
1
MByte 128
MByte 256
Mbyte 512
MByte 1
GByte
Low 3.3 8 16 62s 2.2 hr 4.4 hr 8.8 hr 17 hr
Fair 6.6 16 32 31s 1.1 hr 2.2 hr 4.4 hr 8 hr
Medium 10 24 48 21s 44 m 1 hr 2.2 hr 5.8 hr
High 20 48 96 10s 22 min 44 min 1 hr 2.9 hr
The above table is based on sound recording only. The amount of space needed for noise results
should also be taken into account and can be calculated from a spreadsheet available from our
website: http://www.bksv.co.uk/?ID=3556.
As an example, for the above measurement set-up (8 days logging at 1sec intervals), the required
space is approximately 1Mbyte. Therefore the sound recording times estimated above should be
slightly reduced depending on the size of the memory card in use.
c) The has been set to . Z-weighting is equivalent to Linear
frequency weighting (that is, the signal is not frequency weighted by A- or C-
weightings).
d) The should be set to for the MATRON-Light application.
e) Set the to a suitable value like (typically 100 to 120dB) for
your measurements. The sound recording has a 96dB range from the level you set for the
Peak Recording Level.
f) The is the duration of the sound recorded before the MATRON-3 hand-
switch is pressed to start the recording. For the “Fair” recording quality set in (b) above,
the maximum time is 50 seconds. This facility may be switched off by selecting .
g) The is the duration of the sound recorded after the MATRON-3 hand-
switch is pressed to stop the recording. The maximum time is 5 minutes. This facility may
be switched off by selecting .
h) If you wish to restrict the recording time for each push of the MATRON-3 hand-switch to
reduce the amount of listening time after the investigation, then set the to
.
i) If you wish, you can set a for the sound recording.
j) You can also set a for the sound recording (typically 5 minutes).
The settings in “Occupational Health” are not relevant in the MATRON-Light application.
2.2.10 Tap on (Menu) followed by to reveal: