Bticino 321071 User manual

1
321071
A (mm) B (mm) C (mm)
255 198 27
B
A C
1
2
10
34 5 6
9
8
7
14
15
16
17
18
11 12 13
19
20 21
D45 System
10” touch screen handsfree internal unit
BT00852-a-EN 03/09/2014
Description
D45 System 10” touch screen video internal unit. Complete door entry functions with
alarm managements. International standard SOS pushbutton, intercom function,
programming device touch screen functions. Digital photo frame and camera functions.
Direct call to switchboard function. 6 different default selectable ringtones (can be
changed with your favourite music). Slot for SD CARD. Surge protection. Wall mount
installation.
Power supply : 18-30 Vdc
Stand by absorption: ≤ 100 mA @ 30 V
Max. operating absorption: ≤ 200 mA @ 30V
Operating temperature: (-10)-(+40)°C
LCD display size : 10.2”
LCD display resolution : 800 x 480
Supported SD CARD : 32 Gb maximum
Supported music files : mp3, wav, wma
Dimensional data Legend
1. Mini USB port
2. SD CARD socket
3. Message information LED
4. Connection status LED
5. Alarm LED
6. Microphone
7. Door lock release pushbutton
8. Communication pushbutton
9. SOS pushbutton
10.10”LCD touch screen display
11.Download connector
12.Configurator housing
13.Local power connector
14.Anti removal alarm sensor connector
15.SOS alarm connector
16.SEP entrance panel connector
17.Alarm sensor connector
18.Unlock device connector
19.RJ45 System BUS connector
20.Anti removal switch
21.Loudspeaker
Front & side views
Rear view
Technical data

2
32107110” touch screen handsfree internal unit
BT00852-a-EN 03/09/2014
F F I I #I #I
Configuration
When the biggest number of #FF in whole system is ≤ 20, and the biggest number
of #II is ≤4, and the total risers number is ≤ 50, we recommend to choose (MODE 1)
configuration for system.
When the biggest number of #FF in whole system is more than 20, or the biggest
number of #II is more than 4, we suggest to use (MODE 2) configuration to setup #FF
(choose the biggest number #FF of system) and #II (choose the biggest number #II of
system), then calculate total IU number of system. If the total number (#FF * #II * R ) is
less or equal 4000, use of (MODE 2) is suggested.
Indoor handset must be configured for following parameters:
FF : Floor number
II : Apartment number
#II: Maximum apartments quantity per floor
in a riser
Two different configuration modes available for whole system:
configuration MODE 1 and configuration MODE 2. The main characteristics for each
configuration mode are listed below. POSITION MODE 1 MODE 2
FFF FF
F
III II
I
#I Default for #II is 04,
need not connect the congurator
II
(#II setup using same value for all
system handsets).
#I
Two dierent device conguration ways available:
WAY 1: conguration settings by touch screen
WAY 2: conguration setting by inserting physical congurators
Conguration setting by touch screen - WAY 1 :
At the lower right corner of the main interface, press on the icon, you will enter in the setting page. Click on the icon, to input the installation password (default
password : 686868) and click on the (OK) icon to conrm, you will come to the installation page.
Note : when you come to the sub menu, click on the white circle at front of the setting item, if selected there is a red dot in the white circle. When you operate with the digital
keyboard, click on the (C) icon to delete the last number; click on the (OK) icon to conrm
Room Number Lift
SOS Detector
IU Type Entry Panel
Restore
Home
Back

3
32107110” touch screen handsfree internal unit
BT00852-a-EN 03/09/2014
Room Number IU Type
Configuration
Click on the white circle to select“With apartment interface 323009”or“Without
apartment interface 323009”. If you select“With apartment interface 323009”,you
can’t set the room number because this is directly set by the apartment interface. If
you select“With apartment interface 323009, two modes are available: direct call
mode and normal call mode. With direct call mode, the room number is a digital
value (1 to 4000).With normal call mode, the room number is a combination of oor
number and room number. You need to set the room number and the maximum
apartment quantity per oor.
Click on the white circle to select“With lift controller”or“Without lift controller”.
If you select“With lift controller”, a lift icon will appear in the main interface. In
idle state, press this icon or the unlock key to call the lift.
Note : lift control function should be equipped with a lift controller interface and
supported by the lift manufacturers. Default setting is without lift controller.
Click on the white circle to select SOS alarm contact status“Normal open” or
“Normal close”.
Default setting is Normal open.
The alarm detector sub menus include two pages, the setting item in the rst page as
below :
Enable /Disable : enable or disable the detector, click on the “Enable”or“Disable”to
switch enable /disable.
Detector mode : set the detector normal open or normal close, select“ON”(normal
open) or“OFF”(normal close) to switch detector mode.
Denition : dene the detector type, (area1-infrared), (area2-door contact), (area3-
smoke), (area 4-gas), (area5-infrared/no infrared), (area 6- infrared/no infrared),
(area 7- infrared/no infrared), (area 8- infrared/no infrared), click on the“infrared”or
“no infrared”to switch detector denition of area 5 to area 8. Area1 to area 4 can’t be
changed.
Status : display the detector status, when it becomes blue detector is enabled and
when it becomes gray means disabled.
Areas : show area1 to area 8 alarms.
Click on“Reset”to restore the parameters of the page to default value.
Click on the PgDn icon to have access to the second page. Setting item in the second
page as below:
Alarm : dene alarm whether with sound, click on the white circle to select“YES/ON”.
Eective time for alarmed : click on the white circle to set the eective time as 40
sec./100 sec./150 sec./210 sec./225 sec.
Delay : when the detector monitors an alarm, it will report the message after the
setting delay time. You can click on the white circle to set the delay time as 40 sec./100
sec./150 sec./210 sec./225 sec. For Area 3 and Area 4 you can’t set delay time.
Click on“reset”to restore the parameters of the page to default value.
Click on the PgUp icon to return to the rst page
Lift Entry Panel
SOS Restore
Detector
Click on the white circle to select“Master”or“Slave”IU. When one apartment install
multiple handsets, if the handsets be called, only the master handset opens the video,
slave handsets do not open the video. If the slave handset answered, the other handset
returns to static, the answered handset open the video and audio, and then you can
talk with the entry panel.
Default setting is master handset.
Click on the white circle to select“Doorbell”or“Entry panel”. If the handset linked
is a small entry panel, we can set whether monitor the small entry panel, if you select
“Monitor enable”,“Video door phone”menu will display“ ”.
When the small entry panel call handset, the handset will ring and turn on the video;
if linked with doorbell ,it can’t monitor and when the handset detect income signal the
handset only ringing for 10 seconds.
Click on“OK”to restore all the parameters to default value or click on“Cancel”to abort
your operation.

4
32107110” touch screen handsfree internal unit
BT00852-a-EN 03/09/2014
Configuration
Example (A):
The number of handsets is 1204, each floor has 4 handsets, the system configuration
mode is Mode 1, the handset configuration should be as follows
POSITION CONFIGURATION VALUE REMARKS
F 1
F 2
I 0 It is ok not to insert congurator 0
I 4
#I Because the default value of #II is 4, no
congurator is needed
#I
Example (B):
The number of handsets is 1206, each floor has 8 handsets. System configuration mode
2 is used. The handset configuration should be as follows:
POSITION VALUE REMARKS
F 1
F 2
I 0 It is ok not to insert congurator 0
I 6
#I 0 It is ok not to insert congurator 0
#I 8
Configuration setting by inserting phisical configurators - WAY 2 :
Side pushbutton functions
SOS Key : in case of urgent or unexpected situation, press on the “SOS key” to send the
alarm message to the management center.
Answer Key :
When a visitor calls the host, press the “Answer key” to talk with him, during which you
can press again on the key to end the talk.
Unlock Key :
During the communication with the entrance panel or the small entrance panel, press
on the “Unlock key” to unlock and call the lift.
Icons quick explanations
F F I I #I #I
Back Return to previous menu
Home Return to the main interface
PgUp Page up
PgDn Page down
Anti-disturb mode, the status LED on (red)
Outside mode, the status LED on (pink)
Home mode, the status LED on (blue)

5
32107110” touch screen handsfree internal unit
LED indicators
IU device supports an SD CARD (32 Gb max.). The icon pops up at the up-right angle of
the screen, meaning that the storage card has been inserted. When inserted, sound and
image media contents can be used.
Supported audio format : MP3, WAV, WMA.
Supported images format : JPG, BMP.
Device can be connected to a PC by using an universal USB cable in order to share music
and photos. PC must be equipped with the USB 2.0 and one of the following operating
systems :
MAC OS X v10.5.8 or higher version
Windows 7, Windows Vista or Windows XP Home or Professional(SP3).
SD Card storage Device connection
LED Status of the internal unit
Status LED
Red ON Anti disturb mode
Blue ON Common mode
Pink ON Outside mode
Red Quick flash Being called, no answer
Red Slow flash Talking
Information LED
Off Dim No new message
Blue Quick flash New message
Alarm LED
Off DIM Unguarded
Red Slow flash Guarded, without alarm
Red Quick flash Alarm occurs
BT00852-a-EN 03/09/2014
Other Bticino Touchscreen manuals
Popular Touchscreen manuals by other brands

interactive scape
interactive scape Scape Tangible 43 operating manual

Beijer Electronics
Beijer Electronics X2 marine 15 manual

CIAT
CIAT DynaCIAT LG instruction manual

Sanuvox
Sanuvox Bio Smart Screen instruction manual

Elo TouchSystems
Elo TouchSystems 1937L user manual

panel
panel PC PSG2-EP Series user manual