buratti meccanica Clorofilla SAVANA User manual

Clorofilla
Buratti Meccanica S.r.l. Page 1of 16
Serial Number
Manufacturing year
USE AND MAINTENANCE MANUAL
Original Instructions
English

Clorofilla
Buratti Meccanica S.r.l. Page 2of 16
1.INTRODUCTION page 3
1.1. THE MANUAL page 3
1.2. COPYRIGHT page 3
1.3. HOW TO READ THIS MANUAL page 3
1.4. GENERAL WARNINGS page 3
2.GENERAL INFORMATION page 4
2.1. MANUFACTURER’S DATA page 4
2.2. CLOROFILLA SAVANA’S DATA page 4
2.3. WARRANTY page 4
2.4. GENERAL WARNINGS page 4
3.GENERAL DESCRIPTION page 5
3.1. MAIN CHARACTERISTICS AND FUNCTIONS page 5
3.2. HOW TO USE CLOROFILLA SAVANA page 5
3.3. CLOROFILLA SAVANA’S COMPONENTS page 6
3.4. TOOLS page 7
3.5. DIMENSIONS page 7
4.UNPACKING AND INSTALLATION page 8
4.1 RECOMMENDED INSTALLATION page 8-9
4.2 ASSEMBLING AND START-UP page 10
4.3 ELECTRIC WIRING page 11
4.4 ELECTROMAGNETIC COMPATIBILITY page 11
5.MAINTENANCE page 12
5.1. MAINTENANCE OPERATIONS page 12
5.2. CLOROFILLA SAVANA’S DISPOSAL page 12
6. ATTACHMENTS page 13

Clorofilla
Buratti Meccanica S.r.l. Page 3of 16
1. INTRODUCT
1.1. THE MANUAL
IMPORTANT: This manual must be carefully stored and replace in case of any deterioration or
lack of readability.
1.2. COPYRIGHT
This manual is under the ownership of BURATTI MECCANICA S.r.l. Every duplicate, even partial, is
strictly prohibited. The descriptions and the illustrations given in this manual are not binding.
BURATTI MECCANICA S.r.l. is the only one who can edit it.
© RESERVED RIGHTS: Every reproduction right in this manual is reserved to BURATTI MECCANICA
S.r.l.
Reprint, duplication and translation are prohibited without a written authorization by BURATTI
MECCANICA S.r.l. even partially. The manual cannot be given to third parties without any written
authorization by BURATTI MECCANICA S.r.l..
1.3. HOW TO READ THIS MANUAL
In this manual have been used recurring graphic styles with the aim to make the comprehension
easier. Warnings and/or the instructions that are essential have been highlighted with the following
symbols:
IMPORTANT: means a very important information worthy of attention.
ATTENTION: means helpful hints that must be taken into consideration to avoid damaging
CLOROFILLA TRAIL or its parts.
1.4. GENERAL WARNINGS
This manual has been issued by the manufacturer and it is part of CLOROFILLA’s equipment. It
contains all the information needed to guarantee its usage and maintenance.
BURATTI MECCANICA S.r.l. cannot predict every single risk, hence all the warnings included in this
manual may not cover all security’s cautions. If you have any doubt regarding installation, use and
maintenance procedures, please refer to BURATTI MECCANICA S.r.l.
IMPORTANT: The person in charge of the installation of CLOROFILLA TRAIL must have read this
manual in all its parts before the start-up.
IMPORTANT BURATTI MECCANICA S.r.l. has the right to amend CLOROFILLA TRAIL and its technical
documentation without any requirement by third parties. Contents and warning of this manual are
valid starting from the issuing.
Q
Q
Q
Q

Clorofilla
Buratti Meccanica S.r.l. Page 4of 16
2. GENERAL INFORMATION
2.1. MANUFACTURER’S DATA
Buratti Meccanica S.r.l.
Headquarter: via Archimede n. 535, 47521 Cesena (FC)
Tel. +39 0547 301623
Fax. +39 0547 645734
Web: http://www.burattimeccanica.com
Mail: info@burattimeccanica.com
2.2. CLOROFILLA SAVANA’S DATA
CLOROFILLA’S work stand data, which are the object of this manual, are the following
SERIAL NUMBER:
MANUFACTURING YEAR:
ATTENTION: Do not remove or damage the identification plate.
2.3. WARRANTY
CLOROFILLA’s warranty lasts 24 months. CLOROFILLA SAVANA has successfully passed in the factory
all the tests required by the manufacturer.
Warranty does not cover vandalism and tampering but only materials, manufacturing and assembly
defects.
2.4. GENERAL WARNINGS
The manufacturer waives any and all responsibility for damages caused by non-observance of the
instructions of this manual.
ATTENTION: Before starting any operation, check the working area looking for possible endangered
condition for people or CLOROFILLA SAVANA.
ATTENTION: CLOROFILLA SAVANA must be only used with bicycles.

Clorofilla
Buratti Meccanica S.r.l. Page 5of 16
3. GENERAL DESCRIPTION
CLOROFILLA SAVANA is a bench for the service of bicycles that can be used to recharge e-bikes’
batteries; the bench provides two charging sockets with their own compartments where it is
possible to shelter and lock one own’s battery charger.
The bench also provides two bike racks made of wood on its sides.
3.1. MAIN CHARACTERISTICS AND FUNCTIONS
MAIN CHARACTERISTICS AND FUNCTIONS
RECHARGE
BICYCLE STAND
URBAN FURNITURE
3.2. HOW TO USE CLOROFILLA SAVANA
Place the bicycle’s wheel in the rack.
Connect the battery charger and put it in the metal compartment; close the metal lid.
The presence of a metal ring allows to secure both the compartment and the bicycle with a lock
and keep them safe during recharge.
CLOROFILLA SAVANA is meant to be a two seats bench while recharging the battery of the e-bike.

Clorofilla
Buratti Meccanica S.r.l. Page 6of 16
3.3. CLOROFILLA SAVANA’S COMPONENTS
Ref.
Qty
DESCRIPTION
1
2
Bike rack
2
2
Compartment for battery charger
3
1
Wooden seat
4
2
Electric socket
5
2
Safety ring for lock
3.4. TOOLS
1
2
4
1
3
5

Clorofilla
Buratti Meccanica S.r.l. Page 7of 16
CLOROFILLA SAVANA bench comes with 2 Schuko power sockets and 2 lateral bike racks. The two
sockets are placed inside the metal compartments provided with a ring that allow to secure the
battery charger inside the compartment and the bicycle while charging with the same lock.
3.5. DIMENSION

Clorofilla
Buratti Meccanica S.r.l. Page 8of 16
4. UNPACKING AND INSTALLATION
Unpack the machine and ensure that it has not been damaged during transport.
Packaging dimensions cm: 100 x 120 x 60 cm
Packaging type: wood
Packaging weight: about 50kg
The installation is entirely borne by the buyer. For any technical information (installation specifics,
electrical connection, floor characteristics, electromagnetic compatibility) please refer to this use
and maintenance manual.
4.1 RECOMMENDED INSTALLATION
CLOROFILLA must be fixed to a concrete base or any other compact and not slatted resistant
material. The recommended technical characteristics are the following.
welded wire mesh Ø6 100x100
lift during bottom pouring
free terrain
concrete slab C20/25
SECTION A-A
Installation height of the net 125

Clorofilla
Buratti Meccanica S.r.l. Page 9of 16
POWER CORD OUTLET
Anchor characteristics
Non-cracked concrete
Type
Anchorage
depth
hef
[mm]
Minimum support
thickness
hmin
[mm]
Torque
Tinst
[Nm]
Recommended
tensile load
Nracc3
[kN]
Recommended
shear load
Vracc3
[kN]
1) The appropriate safety factors have been taken into account.
2) It is possible to use lower span and edge distance only if the recommended load has been reduced.
3) For a combination of tensile and shear actions, the reported loads must be reduced
Critical
span
scr,N2
[mm]
Recommended
shear load
Vracc
[kN]
Critical edge
distance
ccr,N2
[mm]
Recommended
shear load
Vracc
[kN]

Clorofilla
Buratti Meccanica S.r.l. Page 10 of 16
4.2 UNBOXING PROCESS AND START-UP
CLOROFILLA SAVANA comes fixed to a wooden platform
1) Cut the plastic straps (scissors).
2) Unscrew the safety nuts (13 mm wrench) and cut the plastic stripes.
3) Fix Clorofilla Savana to the ground. The installation is completed.
ATTENTION: do not use CLOROFILLA SAVANA BENCH until it hasn’t been fixed to the floor.

Clorofilla
Buratti Meccanica S.r.l. Page 11 of 16
4.3 ELECTRIC WIRING
CLOROFILLA SAVANA bench operates a voltage of 220 - 230volt 50Hz. Connect the grounding wire,
plug CLOROFILLA SAVANA bench’s socket to the mains at 220volt, turn on the master switch.
ATTENTION: CLOROFILLA SAVANA must be connected to a network that complies with legal
standards and must be fixed to the floor. Plug CLOROFILLA SAVANA in.
4.4 ELECTROMAGNETIC COMPATIBILITY
With the aim to limit any external damage to CLOROFILLA please follow the following instructions:
• Every metallic part of CLOROFILLA must be placed on the floor,
To guarantee the correct functioning, the final user must guarantee that CLOROFILLA SAVANA has
been
properly placed to the ground.

Clorofilla
Buratti Meccanica S.r.l. Page 12 of 16
5. MAINTENANCE
Maintenance operations are easy and they can be done by everyone.
5.1. MAINTENANCE OPERATIONS
To guarantee a correct functioning of CLOROFILLA we recommend to do some easy maintenance
operations. The ordinary CLOROFILLA’s cleaning maintenance can be done using a wet cloth with a
non-aggressive cleaner. For any other maintenance or checks, refer to the chart 1.
Chart 1 –Maintenance
5.2. CLOROFILLA SAVANA’S DISPOSAL
In any case of disposal, in order to preserve the environment, divide metallic parts, wooden parts
and plastic parts from each other and hand everything out to the ecologic recycling depot.
ENVIRONMENT: Divide these components and dispose of them into recycling depots.
COMPONENT
ACTION
PERIOD
BASIC STRUCTURE
Check the presence of cracks
(visual inspection)
12 months
WOODEN PANELS
Check the presence of
corrosions
12 months
BICYCLE SUPPORTS
Check the presence of
corrosions
12 months
PAINTING
Visual inspection
24 months
ALL THE STRUCTURE
Regular inspection
24 months

Clorofilla
Buratti Meccanica S.r.l. Page 13 of 16
6. ATTACHMENTS
CE DECLARATION OF CONFORMITY
INSTALLATION DRAWING
ELECTRICAL PANEL

Clorofilla
Buratti Meccanica S.r.l. Page 14 of 16
CE DECLARATION OF CONFORMITY
The manufacturer
Buratti Meccanica S.r.l.
Via Archimede, 535 47521 Cesena (FC) –ITALIA
Tel. +39 0547 301623
DECLARES
that the equipment called CLOROFILLA SAVANA SEDUTA
Serial Number:
has been designed and built in compliance with the essential
health and safety requirements of the following directives:
2014/35/UE Low Voltage Directive (LVD)
ù2014/30/UE Electro Magnetic Compatibility Directive (EMC)
Place and date issued Signature
Cesena _______________ Buratti Meccanica S.r.l.

2P
In 10A
PI 4,5kA
Idn 0,03A / A
Socket UNEL Socket
UNEL
P30/P17 P30/P17
2P+T
10-16A
IP55
2P+T
10-16A
IP55
Id
CLOROFILLA MODEL "BENCH"
Socket UNEL P30/P17
2P+T / 10-16A IP55
Socket UNEL P30/P17
2P+T / 10-16A IP55
Safety switch
1N - In 10A - Idn 0,03A -
PdI 4,5kA
Attention! : The device is delivered for the voltage indicated on the technical label.
- As prescribed by current regulations, a single-pole magnetothermal switch in accordance with IEC 61008 or IEC 61009,
with a maximum rated current of 10A, must be interposed between the device and the distribution network.
- The connection to the electrical network must be carried out in accordance with the CEI 64-8 standards.
- Check the efficiency of the grounding system.
- The device must be included in an equipotential bonding system.
- Once the connection work is completed, it is necessary to ensure that the installation is done in accordance with best
practices, and the device functions as per the instructions.
- - To maintain the device's electrical safety efficiency, an annual maintenance is required, which includes checking the
proper functioning of the on-board differential switch.

Clorofilla
Buratti Meccanica S.r.l. Page 16 of 16
Other manuals for Clorofilla SAVANA
1
Table of contents
Other buratti meccanica Bicycle Accessories manuals

buratti meccanica
buratti meccanica Clorofilla SAVANA User manual

buratti meccanica
buratti meccanica Clorofilla Trail User manual

buratti meccanica
buratti meccanica Clorofilla Spot User manual

buratti meccanica
buratti meccanica Clorofilla User manual

buratti meccanica
buratti meccanica Clorofilla Sequoia User manual