2
The bolts have to be extended. Press the ”SET“
button – the hour display is blinking.
Press the ”H/M“ button until the required hour is
displayed.
(Hour display: A 1-12 = 1-12 o´clock, P 1-12 = 13-24
o´clock). Press the ”SET“ button – the minute display
is blinking. Press the ”H/M“ button again until the
required minute is displayed. For conrmation press
the ”SET“ button.
CLOCK TIME ADJUSTMENT
The safe reaches its intended protective function only
after it has been xed to a massive part of a building.
Please use the marked xing points (at the wall and/
or on the oor) in order to secure the necessary local
connection.
INSTALLATION
Press the ”Enter“ button, enter the master code
(factory code 12345678) and press the ”Enter“
button again. The LCD will show ”PASS 1“, starting
a 10 second count. Once this period has passed the
user code will be displayed for a short moment and
the door opens automatically. ATTENTION: In order
to close the safe the user code must be entered
anew (see also “Changing to a new user code”).
OPENING THE SAFE WITH THE MASTER CODE
Subjet to errors and changes.
Point Safe < 03-2006
If you want to use the safe in the Hotel version, it can
be shifted form the normal mode to the Hotel mode
with the master code. The door has to be opened
and the bolts have to be extended. Press ”Enter“,
enter your 8-digit master code and press “Enter“
again. The LCD shows ”PASS 1“, starting a 10 second
count. Press the ”Enter“ button within this 10 sec.
period, enter the code ”16805“ and conrm the
shifting by pressing ”Enter“. The LCD shows
”SET-05“. If now the door remains open for more
than 5 minutes, the user code has to be entered
again. If you want to shift back to the normal mode
please proceed as mentioned above and use the code
“16800” in the according point. ”SET-00“ will appear
on the LCD and the user code will be valid indenitely
also when the door is open.
SPECIAL FEATURE HOTEL VERSION:
Power supply: 5 x LR6/AA/1,5V batteries
(Alkaline)
Working humidity: 20%~95% rH – non-condensed /
non-condensing
TECHNICAL INFORMATION
The door has to be open and the bolts have to be
extended. Press the ”Enter“ button, enter the master
code (factory code 12345678) and press the ”Enter“
button. The LCD will display “PASS 1“, starting a 10
second count. Press the “Enter” button again within
this 10 sec. period. Now enter the new master code
(8 digits), press the ”Enter“ button, enter the new
master code for a second time and press the “Enter“
button once more. If the LCD shows “Good”, the
electronic has now saved the new code.
CHANGING OF THE MASTER CODE