manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BURG WATCHER
  6. •
  7. Measuring Instrument
  8. •
  9. BURG WATCHER ProfiScale PRECISE PS 7215 User manual

BURG WATCHER ProfiScale PRECISE PS 7215 User manual

Other BURG WATCHER Measuring Instrument manuals

BURG WATCHER PRECISE User manual

BURG WATCHER

BURG WATCHER PRECISE User manual

BURG WATCHER ProfiScale PRECISE User manual

BURG WATCHER

BURG WATCHER ProfiScale PRECISE User manual

BURG WATCHER ProfiScale CROSS User manual

BURG WATCHER

BURG WATCHER ProfiScale CROSS User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PRECISE PS 7215
PRECISE
BURG-WÄCHTER KG
Altenhofer Weg 15
58300 Wetter
Germany
ProfiScale PRECISE
Digital caliper
en Operating instructions
ZERO
ABS
/
cm
inch
150 mm
BA PRECISE 06/2015
www.burg.biz
ProfiScale PRECISE PS 7220 2
EXTRA
+
+
1,5V
C D
AB
E
Introduction
The PRECISE PS 7215 digital callipers will simplify numerous domestic and
industrial tasks.
The ProfiScale PRECISE digital callipers offer a convenient and easy way of
measuring the finest distances and diameters. The digital display shows the
results in clearly legible form and with an accuracy of 0.01 mm. Readings
can also be displayed in inches.
Please read the operating instructions fully and keep them in a safe place.
Illustration
AInch/millimetre switching (inch/millimetre toggle button)
BORIGIN button
CON/ OFF button
DZero setting button (ZERO/ABS)
EBattery cover
Safety instructions
Failure to observe the following instructions
may result in personal injury:
1. Before using the device, you must read these instructions carefully to
ensure that you operate the device safely. Keep these instructions in a
safe place.
2. Keep the device away from children and unauthorized persons.
3. For safety reasons and to maintain the warranty on the device, repairs
must only be carried out by qualified personnel using genuine parts.
4. Never expose the device to an electric voltage, as this could damage
the electronics.
5. Do not use the device in the vicinity of inflammable or explosive gases.
6. Do not use the device if it is defective.
7. Handle the device with care and do not drop it.
8. To avoid functional errors, do not dismantle the device.
9. Keep the device clean and dry.
10. When not in use, the device should be stored in the bag supplied.
11. Avoid contact with water and dust.
12. Do not use abrasive cleaners or solvents to clean the device. Use a
damp cloth and mild detergent.
13. Check the battery/batteries regularly to avoid damage.
14. Remove the battery if you are not going to use the device for a long
period.
Warranty
Congratulations!
Thank you for choosing ProfiScale quality measuring technology by BURG-
WÄCHTER. BURG-WÄCHTER offers a warranty of 2 years’ duration from the
date of purchase. The warranty does not cover damage caused by improper
use, overloading the device or incorrect storage as well as normal wear and
defects that only have an insignificant effect on the value or usability of
the device. The warranty shall be immediately invalidated if unauthorized
persons work on the device. In the event that a warranty claim arises, please
hand over the entire device incl. packaging, description and batteries along
with the sales receipt to your dealer.
Technical data
Measuring accuracy 0.01mm
Power supply 1.5V button cell
Measurement speed 1.5m /s
Operating temperature 0 to +40°C
Relative air humidity <80 %
Storage temperature –10 to 60°C
Operating the device
Instructions
• Press the “ON/OFF” button to switch on the device.
• Press the “in/mm” button to select the required unit.
• Calibrate the callipers by pushing the two jaws together and pressing the
“ZERO/ ABS” button.
ZERO/ABS button / ORIGIN button
• The “ZERO/ ABS” button is for the relative zero point and for switching
between absolute and relative measurement. When switching on the
device, it is initially always in the absolute measurement mode.
• Press the “ZERO/ABS” button to switch to the relative measurement
mode.
• To return to the absolute measurement mode, you must push the two
jaws together again. Then press the “ZERO/ABS” button again. When
going from one mode to the other, the original zero position remains
unchanged.
• Exception: you press the “ORIGIN” button and the zero point set here is
retained even after you switch off the callipers.
ProfiScale PRECISE PS 7220 3
EXTRA
+
+
1,5V
C D
AB
E
Important information/troubleshooting
Replacing the battery
An incorrect display (flashing numbers or no display at all) indicates an
empty battery. To replace the battery, press the battery compartment cover
in the direction indicated by the arrow on the cover and replace the old
battery with a fresh one. Note that the positive side of the battery must face
upwards.
Problem Possible cause Solution
Flashing numbers Battery empty Replace battery
No display 1. Battery empty
2. Faulty contact
1. Replace battery
2. Clean the battery
compartment and insert
the battery again.
Numbers no longer
change on the display
Technical fault in the
circuit
Remove the battery
and wait one minute
before re-inserting it.
Disposing of the device
Dear customer,
Please help us avoid unnecessary waste.
Should you intend to dispose of this device at any time, please remember
that many components of this device contain valuable materials, which can
be recycled.
Please be aware that electrical and electronic equipment and
batteries shall not be disposed of as household waste, but
rather collected separately. Please obtain information on the
collecting points for electrical waste from the responsible
authority of you municipality.
If you have any questions concerning the EC declaration
of conformity, please use [email protected]
Printing and typesetting errors excepted.
We reserve the right to make technical changes.