Digital caliper
en Operating instructions
ZERO
ABS
/
cm
inch
150 mm
BA PRECISE 06/2015
www.burg.biz
ProfiScale PRECISE PS 7220 2
EXTRA
+
+
1,5V
C D
AB
E
Introduction
The PRECISE PS 7215 digital callipers will simplify numerous domestic and
industrial tasks.
The ProfiScale PRECISE digital callipers offer a convenient and easy way of
measuring the finest distances and diameters. The digital display shows the
results in clearly legible form and with an accuracy of 0.01 mm. Readings
can also be displayed in inches.
Please read the operating instructions fully and keep them in a safe place.
Illustration
AInch/millimetre switching (inch/millimetre toggle button)
BORIGIN button
CON/ OFF button
DZero setting button (ZERO/ABS)
EBattery cover
Safety instructions
Failure to observe the following instructions
may result in personal injury:
1. Before using the device, you must read these instructions carefully to
ensure that you operate the device safely. Keep these instructions in a
safe place.
2. Keep the device away from children and unauthorized persons.
3. For safety reasons and to maintain the warranty on the device, repairs
must only be carried out by qualified personnel using genuine parts.
4. Never expose the device to an electric voltage, as this could damage
the electronics.
5. Do not use the device in the vicinity of inflammable or explosive gases.
6. Do not use the device if it is defective.
7. Handle the device with care and do not drop it.
8. To avoid functional errors, do not dismantle the device.
9. Keep the device clean and dry.
10. When not in use, the device should be stored in the bag supplied.
11. Avoid contact with water and dust.
12. Do not use abrasive cleaners or solvents to clean the device. Use a
damp cloth and mild detergent.
13. Check the battery/batteries regularly to avoid damage.
14. Remove the battery if you are not going to use the device for a long
period.
Warranty
Congratulations!
Thank you for choosing ProfiScale quality measuring technology by BURG-
WÄCHTER. BURG-WÄCHTER offers a warranty of 2 years’ duration from the
date of purchase. The warranty does not cover damage caused by improper
use, overloading the device or incorrect storage as well as normal wear and
defects that only have an insignificant effect on the value or usability of
the device. The warranty shall be immediately invalidated if unauthorized
persons work on the device. In the event that a warranty claim arises, please
hand over the entire device incl. packaging, description and batteries along
with the sales receipt to your dealer.
Technical data
Measuring accuracy 0.01mm
Power supply 1.5V button cell
Measurement speed 1.5m /s
Operating temperature 0 to +40°C
Relative air humidity <80 %
Storage temperature –10 to 60°C
Operating the device
Instructions
• Press the “ON/OFF” button to switch on the device.
• Press the “in/mm” button to select the required unit.
• Calibrate the callipers by pushing the two jaws together and pressing the
“ZERO/ ABS” button.
ZERO/ABS button / ORIGIN button
• The “ZERO/ ABS” button is for the relative zero point and for switching
between absolute and relative measurement. When switching on the
device, it is initially always in the absolute measurement mode.
• Press the “ZERO/ABS” button to switch to the relative measurement
mode.
• To return to the absolute measurement mode, you must push the two
jaws together again. Then press the “ZERO/ABS” button again. When
going from one mode to the other, the original zero position remains
unchanged.
• Exception: you press the “ORIGIN” button and the zero point set here is
retained even after you switch off the callipers.
ProfiScale PRECISE PS 7220 3
EXTRA
+
+
1,5V
C D
AB
E
Important information/troubleshooting
Replacing the battery
An incorrect display (flashing numbers or no display at all) indicates an
empty battery. To replace the battery, press the battery compartment cover
in the direction indicated by the arrow on the cover and replace the old
battery with a fresh one. Note that the positive side of the battery must face
upwards.
Problem Possible cause Solution
Flashing numbers Battery empty Replace battery
No display 1. Battery empty
2. Faulty contact
1. Replace battery
2. Clean the battery
compartment and insert
the battery again.
Numbers no longer
change on the display
Technical fault in the
circuit
Remove the battery
and wait one minute
before re-inserting it.
Disposing of the device
Dear customer,
Please help us avoid unnecessary waste.
Should you intend to dispose of this device at any time, please remember
that many components of this device contain valuable materials, which can
be recycled.
Please be aware that electrical and electronic equipment and
batteries shall not be disposed of as household waste, but
rather collected separately. Please obtain information on the
collecting points for electrical waste from the responsible
authority of you municipality.
If you have any questions concerning the EC declaration
of conformity, please use [email protected]
Printing and typesetting errors excepted.
We reserve the right to make technical changes.

Other BURG WATCHER Measuring Instrument manuals

BURG WATCHER ProfiScale PRECISE User manual

BURG WATCHER

BURG WATCHER ProfiScale PRECISE User manual

BURG WATCHER ProfiScale CROSS User manual

BURG WATCHER

BURG WATCHER ProfiScale CROSS User manual

BURG WATCHER PRECISE User manual

BURG WATCHER

BURG WATCHER PRECISE User manual

Popular Measuring Instrument manuals by other brands

Trinity SLM102 user manual

Trinity

Trinity SLM102 user manual

PCB Piezotronics IMI SENSORS TOM602D01 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS TOM602D01 Installation and operating manual

ELECTROMATIC Check-Line RH1 Calibration guide

ELECTROMATIC

ELECTROMATIC Check-Line RH1 Calibration guide

UniData Communication Systems Starflow QSD manual

UniData Communication Systems

UniData Communication Systems Starflow QSD manual

Shodex CLNpak EV-2000 Operation manual

Shodex

Shodex CLNpak EV-2000 Operation manual

Irradian L202PMS User handbook

Irradian

Irradian L202PMS User handbook

Gude Expert Power Meter manual

Gude

Gude Expert Power Meter manual

Omega SP-005 user guide

Omega

Omega SP-005 user guide

Spectrum 6110FS user manual

Spectrum

Spectrum 6110FS user manual

ELC MiniStore 3 user manual

ELC

ELC MiniStore 3 user manual

Niigata seiki WCDI-6D instruction manual

Niigata seiki

Niigata seiki WCDI-6D instruction manual

SenNet IoT Pulse Counter Sigfox quick start guide

SenNet

SenNet IoT Pulse Counter Sigfox quick start guide

LaMotte WaterLink SpinTouch 3580-AU manual

LaMotte

LaMotte WaterLink SpinTouch 3580-AU manual

Saia PCD2.H110 manual

Saia

Saia PCD2.H110 manual

Nibe EME 10 Installer manual

Nibe

Nibe EME 10 Installer manual

SYSMEX CyFlow Cube 6 V2m operating manual

SYSMEX

SYSMEX CyFlow Cube 6 V2m operating manual

palintest ChloroSense HR Quick test guide

palintest

palintest ChloroSense HR Quick test guide

GOK BC-1-4 Assembly and operating manual

GOK

GOK BC-1-4 Assembly and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.