ProfiScale PRECISE
Digital caliper
en Operating instructions
ZERO
ABS
/
cm
inch
150 mm
ProfiScale PRECISE PS 7220 2
EXTRA
+
+
1,5V
C D
AB
E
Introduction
The PRECISE PS 7215 digital callipers will simplify numerous domestic and
industrial tasks.
The ProfiScale PRECISE digital callipers offer a convenient and easy way of
measuring the finest distances and diameters. The digital display shows the
results in clearly legible form and with an accuracy of 0.01 mm. Readings
can also be displayed in inches.
Please read the operating instructions fully and keep them in a safe place.
Illustration
AInch/millimetre switching (inch/millimetre toggle button)
BORIGIN button
CON/ OFF button
DZero setting button (ZERO/ABS)
EBattery cover
Safety instructions
Failure to observe the following instructions
may result in personal injury:
Before using the device, you must read these instructions carefully to1.
ensure that you operate the device safely. Keep these instructions in a
safe place.
Keep the device away from children and unauthorized persons.2.
For safety reasons and to maintain the warranty on the device, repairs3.
must only be carried out by qualified personnel using genuine parts.
Never expose the device to an electric voltage, as this could damage4.
the electronics.
Do not use the device in the vicinity of inflammable or explosive gases.5.
Do not use the device if it is defective.6.
Handle the device with care and do not drop it.7.
To avoid functional errors, do not dismantle the device.8.
Keep the device clean and dry.9.
When not in use, the device should be stored in the bag supplied.10.
Avoid contact with water and dust.11.
Do not use abrasive cleaners or solvents to clean the device. Use a12.
damp cloth and mild detergent.
Check the battery/batteries regularly to avoid damage.13.
Remove the battery if you are not going to use the device for a long14.
period.
Warranty
Congratulations!
Thank you for choosing ProfiScale quality measuring technology by BURG-
WÄCHTER. BURG-WÄCHTER offers a warranty of 2 years’ duration from the
date of purchase. The warranty does not cover damage caused by improper
use, overloading the device or incorrect storage as well as normal wear and
defects that only have an insignificant effect on the value or usability of
the device. The warranty shall be immediately invalidated if unauthorized
persons work on the device. In the event that a warranty claim arises, please
hand over the entire device incl. packaging, description and batteries along
with the sales receipt to your dealer.
Technical data
Measuring accuracy 0.01mm
Power supply 1.5 V button cell
Measurement speed 1.5m /s
Operating temperature 0 to +40°C
Relative air humidity <80 %
Storage temperature -10 to 60°C
Operating the device
Instructions
Press the “ON/OFF” button to switch on the device.•
Press the “in/mm” button to select the required unit.•
Calibrate the callipers by pushing the two jaws together and pressing the•
“ZERO/ ABS” button.
ZERO/ABS button / ORIGIN button
The “ZERO/ABS” button is for the relative zero point and for switching•
between absolute and relative measurement. When switching on the
device, it is initially always in the absolute measurement mode.
Press the “ZERO/ABS” button to switch to the relative measurement•
mode.
To return to the absolute measurement mode, you must push the two•
jaws together again. Then press the “ZERO/ABS” button again. When
going from one mode to the other, the original zero position remains
unchanged.
• Exception: you press the “ORIGIN” button and the zero point set here is
retained even after you switch off the callipers.
ProfiScale PRECISE PS 7220 3
EXTRA
+
+
1,5V
C D
AB
E
Important information/troubleshooting
Replacing the battery
An incorrect display (flashing numbers or no display at all) indicates an
empty battery. To replace the battery, press the battery compartment cover
in the direction indicated by the arrow on the cover and replace the old
battery with a fresh one. Note that the positive side of the battery must face
upwards.
Problem Possible cause Solution
Flashing numbers Battery empty Replace battery
No display 1. Battery empty
2. Faulty contact
1. Replace battery
2. Clean the battery
compartment and insert
the battery again.
Numbers no longer
change on the display
Technical fault in the
circuit
Remove the battery
and wait one minute
before re-inserting it.
Disposing of the device
Dear Customer,
please help to reduce waste. Should you decide to dispose of the device,
please bear in mind that many of the components it contains are made from
valuable material that can be recycled.
Please do not throw the device into the normal waste bin. Contact the
responsible office in your area and ask about collection points for electrical
waste.
Printing and typesetting errors excepted.
We reserve the right to make technical changes.

Other BURG WATCHER Measuring Instrument manuals

BURG WATCHER PRECISE User manual

BURG WATCHER

BURG WATCHER PRECISE User manual

BURG WATCHER ProfiScale CROSS User manual

BURG WATCHER

BURG WATCHER ProfiScale CROSS User manual

BURG WATCHER ProfiScale PRECISE PS 7215 User manual

BURG WATCHER

BURG WATCHER ProfiScale PRECISE PS 7215 User manual

Popular Measuring Instrument manuals by other brands

Delta-T Devices WET150 quick start guide

Delta-T Devices

Delta-T Devices WET150 quick start guide

Delta HD2105.2 operating manual

Delta

Delta HD2105.2 operating manual

B meters IWM-LR3 user manual

B meters

B meters IWM-LR3 user manual

red lion Legend Plus Series manual

red lion

red lion Legend Plus Series manual

General DOM5512SD user manual

General

General DOM5512SD user manual

TELEDYNE API T100 user manual

TELEDYNE API

TELEDYNE API T100 user manual

TSI Instruments Quest Edge 7 user manual

TSI Instruments

TSI Instruments Quest Edge 7 user manual

DigiTrak FALCON F5 quick start guide

DigiTrak

DigiTrak FALCON F5 quick start guide

PCB Piezotronics HT352A21/NC Installation and operating manual

PCB Piezotronics

PCB Piezotronics HT352A21/NC Installation and operating manual

Hach POCKET COLORIMETER II Basic user manual

Hach

Hach POCKET COLORIMETER II Basic user manual

Lumel ND20CT user manual

Lumel

Lumel ND20CT user manual

Orion 2030 Reference manual

Orion

Orion 2030 Reference manual

SpiroClinic Compact user manual

SpiroClinic

SpiroClinic Compact user manual

Satimo EME Guard user manual

Satimo

Satimo EME Guard user manual

Tense PTM-01 quick start guide

Tense

Tense PTM-01 quick start guide

Eurolube 1168034 Service guide

Eurolube

Eurolube 1168034 Service guide

Fluke 805 FC user manual

Fluke

Fluke 805 FC user manual

KYORITSU KEW 6310 instruction manual

KYORITSU

KYORITSU KEW 6310 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.