Calcana SR Series Guide

SR-SERIES Specifications, Installation, Operation Service and Spare Parts Manual
Printed in USA ©2019 Calcana USA Ltd. Rev 5 1/19
Low Intensity Infrared Heater/Radiateur à infrarouge a faible intensité
For either indoor or outdoor installation/Installer à l’intérieur ou à l’extérieur
Also for Brooder Use/Aussi pour l’eveage des poules
For Industrial, Commercial, Agricultural Applications.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause property
damage, injury or death. Read (refer to) the
installation operating and maintenance instructions
thoroughly before installing or servicing this
equipment. For assistance or additional information
consult a qualified installer, service agency or the gas
supplier.
ADVERTISSEMENT. L’installation déplacée,
l’ajustement, le changement, le service ou
l’entretien peuvent causer les dommages de
propriété, la blessure ou la mort. Lire (se référer à)
l’installation qui fonctionne et les instructions
d’entretien à fond avant d’installer ou entretenir
cet équipement. Pour obtenir de l’aide ou les
informations supplémentaires consultent un
programme d’installation, une agence de service
ou le fournisseur de gaz qualifié.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may result;
causing property damage, personal injury or loss of
life.
ADVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette notice
pour réduire au minimum le risqué d’incendie ou
d’explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.
-Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
DANGER: WHAT TO DO IF YOU SMELL GAS:
1) Extinguish any open flame
2) DO NOT try to light any appliance.
3) DO NOT use or touch any electrical switches.
4) DO NOT use any phone in your building
5) Turn off gas.
6) Open Windows
7) Leave the building
8) Immediately call your gas supplier from a
neighbor’s phone or after you have left the
building. Follow the gas supplier's instructions.
9) If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier
- Ne pas entreposer ni utiliser d’essence ni d’autres
vapours ou liquidés inflammables à proximité de cet
appareil ou de tout autre appareil.
DANGER: QUE FAIRE SI VOUV SENTEZ UNE
ODEUR DE GAZ:
1) Éteindre la flamme ouverte
2) Ne pas tenter d’allumer d’appareils
3) Ne touchez à aucun interrupteur.
4) Ne pas vous server des téléphonés dans le
bâtiment ou vous vous trouvez.
5) le Virage du gaz.
6) Ouvrir Windows
7) Part le bâtiment
8) Appelez immédiatement votre fournisseur de
gaz depuis un voisin ou âpres que vous êtes
parti le bâtiment. Suivez les instructions du
fournisseur.
9) Si vous ne pouvez rejoindre le service des
incendies.
- L’installation et I' entretien doivent être assures par
un installateur ou un service d’entretien qualifié ou
par fournisseur de gaz.
WARNING: Heat exchanger surface is hot. Do not touch surface or burn may result. Combustible material or
articles should not be placed on or near heater. Observe clearance to combustibles as noted on heater and in this
manual.
INSTALLER: Leave this manual with the
appliance.
CONSUMER: Retain this manual for future
reference.
INSATLLATEUR: Laissez cette notice
avec I’ appareil.
CONSOMMATEUR: Conservez cette
notice pour consultation ultérieure.
Calcana USA Ltd.
30201 County Rd 49
Loxley, AL. 36551
Tel: 251-964-4400
Fax: 251-964-4404

SR-SERIES
ii
TABLE OF CONTENTS
1.0 OWNERS RESPONSIBILITY ------------------------------1
2.0 INSTALLER RESPONSIBILITY---------------------------3
3.0 CODE COMPLIANCE ---------------------------------------4
4.0 SPECIFICATIONS: GENERAL SPECIFICATIONS -----5
5.0 DIMENSIONS ------------------------------------------------7
6.0 INSTALLATION CLEARANCES AND CLEARANCE TO
COMBUSTIBLES ----------------------------------------------------8
6.1 CLEARANCE TO COMBUSTIBLES FOR SPACE HEATING
AND BROODER INSTALLATION -------------------------------------------9
6.2 CLEARANCE TO COMBUSTIBLES FOR SPACE HEATING
AND BROODER INSTALLATION ----------------------------------------- 10
6.3 CLEARANCE TO COMBUSTIBLES FOR SPACE HEATING
AND BROODER INSTALLATION ----------------------------------------- 11
7.0 PRE-INSTALLATION INSPECTION: ------------------ 12
8.0 PACKAGING CONTENTS & DESCRIPTION OF
PARTS:-------------------------------------------------------------- 13
BURNER PACKAGE---------------------------------------------------- 13
PIPE BOXES------------------------------------------------------------- 14
10’ (3 M) REFLECTOR PACKAGE ----------------------------------- 15
15’ (4.16 M) REFLECTOR PACKAGE ------------------------------- 16
20’ (6.1 M) REFLECTOR PACKAGE--------------------------------- 17
30’ (9.1 M) REFLECTOR PACKAGE--------------------------------- 18
40’ (12.2 M) REFLECTOR PACKAGE ------------------------------- 19
50’ (15.2 M) REFLECTOR PACKAGE ------------------------------- 20
60’ (18.3 M) REFLECTOR PACKAGE ------------------------------- 21
70’ (21.3 M) REFLECTOR PACKAGE ------------------------------- 22
80’ (24.4 M) REFLECTOR PACKAGE ------------------------------- 23
10’ (3 M) EXTENSION KIT-------------------------------------------- 24
SIDE REFLECTOR PACKAGE ----------------------------------------- 25
90° ELBOW PACKAGE ------------------------------------------------ 26
180° U-BEND PACKAGE---------------------------------------------- 26
SIDE WALL VENT KIT ------------------------------------------------- 27
OUTDOOR INSTALLATION KIT-------------------------------------- 27
9.0 INSTALLATION ------------------------------------------- 28
9.1 PLANNING---------------------------------------------------------- 28
10.0 SUSPENSION OF HEATER: ----------------------------- 29
10.1 HORIZONTAL INSTALLATION---------------------------------- 29
SUSPENSION POINTS------------------------------------------------- 29
HORIZONTAL INSTALLATION --------------------------------------- 30
HORIZONTAL INSTALLATION --------------------------------------- 31
10.2 TILT INSTALLATION ---------------------------------------------- 32
25° TILT (ALL LENGTHS) --------------------------------------------- 32
45° TILT (ALL LENGTHS) --------------------------------------------- 33
11.0 ASSEMBLY OF COMPONENTS------------------------- 34
11.1 GENERAL INSTRUCTIONS--------------------------------------- 34
11.2 COMPONENT ASSEMBLY--------------------------------------- 35
BAFFLE - TRANSPORT POSITION----------------------------------- 35
BURNER HEAD TO FIRST 10’ (3 M) OF REFLECTOR PACKAGE36
JOINT HANGER TO REFLECTOR ------------------------------------ 36
CLAMP COUPLER------------------------------------------------------ 37
END CAP TO REFLECTOR -------------------------------------------- 37
BAFFLE/TURBULATOR INSTALLATION---------------------------- 38
VENT ADAPTOR INSTALLATION------------------------------------ 38
12.0 ASSEMBLY OVERVIEW --------------------------------- 39
12.1 ASSEMBLY OF OPTIONS ---------------------------------------- 39
12.2 REFLECTOR ASSEMBLY: ALL LENGTHS ---------------------- 40
10' (3M) REFLECTOR PACKAGE ------------------------------------ 40
15' (4.16M) REFLECTOR PACKAGE -------------------------------- 41
20' (6.1M) REFLECTOR PACKAGE---------------------------------- 42
30' (9.1M) REFLECTOR PACKAGE---------------------------------- 43
40' (12.2M) REFLECTOR PACKAGE -------------------------------- 44
50' (15.2M) REFLECTOR PACKAGE-------------------------------- 45
60' (18.3M) REFLECTOR PACKAGE-------------------------------- 46
70' (21.3M) REFLECTOR PACKAGE-------------------------------- 47
80' (24.4M) REFLECTOR PACKAGE-------------------------------- 48
SIDE WALL VENT KIT------------------------------------------------- 49
OUTDOOR INSTALLATION KIT ------------------------------------- 49
90° ELBOW KIT-------------------------------------------------------- 50
180° U-BEND KIT------------------------------------------------------ 51
SIDE REFLECTOR ------------------------------------------------------ 52
13.0 OPTIONAL COMBUSTION AIR SUPPLY ------------ 53
COMBUSTION AIR HORIZONTAL ---------------------------------- 54
COMBUSTION AIR VERTICAL--------------------------------------- 54
14.0 VENTING--------------------------------------------------- 55
VENTING MANUAL ---------------------------------------------- 55
ANSI Z83.20-2016/CSA 2.34-2016 ------------------------- 55
GAS PRODUCTS NO. 405 --------------------------------------- 55
JANUARY 1, 2019 ------------------------------------------------ 55
D. (CONTINUED) ROOF EXHAUST: TWO OR MORE UNITS - USE 'B'
STYLE CHIMNEY.------------------------------------------------------------- 59
15.0 OUTDOOR APPLICATIONS ---------------------------- 62
OUTDOOR INSTALLATIONS----------------------------------------- 62
16.0 UNVENTED APPLICATIONS --------------------------- 63
UNVENTED INSTALLATIONS---------------------------------------- 63
17.0 GAS PIPING------------------------------------------------ 64
18.0 GAS CONNECTION --------------------------------------- 65
FLEX CONNECTOR ---------------------------------------------------- 65
19.0 GAS INPUT RATE ---------------------------------------- 67
20.0 ELECTRICAL CONNECTION --------------------------- 68
ELECTRICAL CONNECTION BURNER HEAD ---------------------- 68
21.0 WIRING DIAGRAM -------------------------------------- 69
21.1 BURNER ASSEMBLY WIRING DIAGRAM --------------------69
21.2 BURNER ASSEMBLY WIRING DIAGRAM. LADDER
DIAGRAM--------------------------------------------------------------------- 70
22.0 THERMOSTATS ------------------------------------------ 71
22.1 LOW VOLTAGE (SINGLE HEATER)----------------------------- 71
LOW VOLTAGE: ONE THERMOSTAT - ONE HEATER ---------- 71
22.2 LINE VOLTAGE (TWO OR MORE HEATERS) ----------------72
LINE VOLTAGE: ONE THERMOSTAT –TWO OR MORE
HEATERS ---------------------------------------------------------------------- 72
23.0 INITIAL START-UP -------------------------------------- 73
24.0 GAS VALVES----------------------------------------------- 74
25.0 SEQUENCE OPERATION-------------------------------- 75
25.1 DESCRIPTION OF 3-TRY DIRECT SPARK IGNITION
SYSTEM: ----------------------------------------------------------------------75
25.2 OPERATIONS:------------------------------------------------------75
POWER UP/STANDBY------------------------------------------------ 75
HEAT MODE ----------------------------------------------------------- 75
FLAME FAILURE - RE-IGNITION------------------------------------ 75
26.0 TROUBLESHOOTING ----------------------------------- 76
NO POWER TO HEATER --------------------------------------------- 76
INITIAL ELECTRICAL CHECKS --------------------------------------- 76
INITIAL GAS CHECKS ------------------------------------------------- 77
ELECTRICITY AND GAS TO HEATER, BUT STILL INOPERATIVE77
CHECK CONTROL BOARD ------------------------------------------- 78
FAULT CONDITIONS-------------------------------------------------- 78
INTERNAL CONTROL FAULT---------------------------------------- 78
AIRFLOW FAULT - LOCK OUT (COMBUSTION AIR FLOW
PROBLEMS)------------------------------------------------------------------- 78
FLAME WITH NO CALL FOR HEAT (FLAME FAULT) ------------ 79
IGNITION LOCK OUT (FAILURE TO LIGHT)----------------------- 79
FLAME SENSOR CURRENT CHECK--------------------------------- 79
PROPER ELECTRODE LOCATION----------------------------------- 80
27.0 MAINTENANCE------------------------------------------- 81
28.0 PARTS: ----------------------------------------------------- 82

SR-SERIES
iii
28.1 BURNER HEAD AND RELATED PARTS ----------------------- 82
28.2 REFLECTOR AND TUBE PARTS--------------------------------- 83
28.3 PARTS LIST: -------------------------------------------------------- 84
REPLACEMENT BURNER HEADS ----------------------------------- 84
BURNER HEAD COMPONENTS------------------------------------- 85
TUBE COMPONENTS ------------------------------------------------- 86
REFLECTOR COMPONENTS ----------------------------------------- 86
29.0 WARRANTY ----------------------------------------------- 87
30.0 FUEL CONVERSION -------------------------------------- 88
30.1 CONVERSION KIT FOR HONEYWELL SINGLE INPUT GAS
VALVE 88
31.0 EXAMPLE OF CONVERSION KIT LABEL ------------ 92

SR-SERIES
iv
TABLE OF FIGURES
Figure 1. EQUIPMENT DIMENSION .......................................... 7
Figure 2. UNVENTED CLEARANCES........................................... 8
Figure 3. VENTED CLEARANCES................................................ 8
Figure 4. STANDARD REFLECTOR ............................................. 9
Figure 5. ONE SIDE REFLECTOR ................................................ 9
Figure 6. TWO SIDE REFLECTOR ............................................. 10
Figure 7. 25° TO 45° TILT........................................................ 10
Figure 8. U-Tube Standard ..................................................... 11
Figure 9. 25° TO 45° TILT U-Tube ........................................... 11
Figure 10. BURNER PACKAGE CONTENTS .............................. 13
Figure 11. PIPE BOX CONTENT ............................................... 14
Figure 12. 10’ (3 M) REFLECTOR PACKAGE CONTENTS .......... 15
Figure 13. 15’ (4.16 M) REFLECTOR PACKAGE CONTENTS ... 16
Figure 14. 20’ (6.1 M) REFLECTOR PACKAGE CONTENTS....... 17
Figure 15. 30’ (9.1 M) REFLECTOR PACKAGE CONTENTS ....... 18
Figure 16. 40’ (12.2 M) REFLECTOR PACKAGE CONTENTS ..... 19
Figure 17. 50’ (15.2 M) REFLECTOR PACKAGE CONTENTS..... 20
Figure 18. 60’ (18.3 M) REFLECTOR PACKAGE CONTENTS ..... 21
Figure 19. 70’ (21.3 M) REFLECTOR PACKAGE CONTENTS ..... 22
Figure 20. 80’ (24.4 M) REFLECTOR PACKAGE CONTENTS ..... 23
Figure 21. 10’ (3 M) EXTENSION PACKAGE CONTENTS .......... 24
Figure 22. SIDE REFLECTOR PACKAGE CONTENTS ................. 25
Figure 23. 90° ELBOW PACKAGE ............................................ 26
Figure 24. 180° U-BEND PACKAGE ......................................... 26
Figure 25. SIDE WALL VENT KIT.............................................. 27
Figure 26. OUTDOOR INSTALLATION PACKAGE CONTENTS... 27
Figure 27. EXAMPLE SUSPENSION DETAILS ........................... 29
Figure 28. HORIZONTAL INSTALLATION - 10' (3 M) PACKAGE 30
Figure 29. HORIZONTAL INSTALLATIONS –15’ (4.6 M) TO 80’
(24.4 M) PACKAGES................................................................. 31
Figure 30. 25° TILT.................................................................. 32
Figure 31. 45° TILT.................................................................. 33
Figure 32. BAFFLE/TURBULATOR REMOVAL FROM
TRANSPORTATION .................................................................. 35
Figure 33. BURNER HEAD INSTALLATION............................... 36
Figure 34. JOINT HANGER INSTALLATION .............................. 36
Figure 35. CLAMP COUPLER INSTALLATION........................... 37
Figure 36. END CAP INSTALLATION........................................ 37
Figure 37. BAFFLE / TURBULATOR INSTALLATION ................. 38
Figure 38. BAFFLE / TURBULATOR + FLUE ADAPTOR
INSTALLATION......................................................................... 38
Figure 39. 10' (3m) REFLECTOR PACKAGE INSTALLATION ..... 40
Figure 40. 15' (4.16m) REFLECTOR PACKAGE INSTALLATION 41
Figure 41. 20' (6.1m) REFLECTOR PACKAGE INSTALLATION .. 42
Figure 42. 30' (9.1m) REFLECTOR PACKAGE INSTALLATION .. 43
Figure 43. 40' (12.2m) REFLECTOR PACKAGE INSTALLATION 44
Figure 44. 50' (15.2m) REFLECTOR PACKAGE INSTALLATION 45
Figure 45. 60' (18.3m) REFLECTOR PACKAGE INSTALLATION 46
Figure 46. 70' (21.3m) REFLECTOR PACKAGE INSTALLATION.47
Figure 47. 80' (24.4m) REFLECTOR PACKAGE INSTALLATION.48
Figure 48. SIDE WALL VENT KIT INSTALLATION......................49
Figure 49. OUTDOOR INSTALLATION KIT................................49
Figure 50. 90° ELBOW KIT INSTALLATION...............................50
Figure 51. 180° U-BEND KIT INSTALLATION............................51
Figure 52. SIDE REFLECTOR INSTALLATION ............................52
Figure 53. OUTSIDE COMBUSTION AIR SUPPLY......................54
Figure 54. OUTDOOR INSTALLATIONS....................................62
Figure 55. UNVENTED INSTALLATIONS...................................63
Figure 56. GAS LINE CONNECTION WITH CERTIFIED FLEXIBLE
GAS CONNECTION ...................................................................66
Figure 57. ELECTRICAL JUNCTION BOX...................................68
Figure 58. BURNER ASSEMBLY WIRING DIAGRAM..................69
Figure 59. BURNER ASSEMBLY WIRING DIAGRAM. LADDER
DIAGRAM.................................................................................70
Figure 60. LOW VOLTAGE THERMOSTAT WIRING ..................71
Figure 61. LINE VOLTAGE THERMOSTAT WIRING...................72
Figure 62. GAS VALVE .............................................................74
Figure 63. PRESSURE REGULATOR..........................................74
Figure 64. FLAME SENSOR CURRENT CHECK ..........................79
Figure 65. PROPER ELECTRODE LOCATION.............................80
Figure 66. BURNER HEAD PARTS ............................................82
Figure 67. REFLECTOR AND TUBE PARTS................................83

SR-SERIES
1
1.0 OWNERS RESPONSIBILITY
Thank you for purchasing our product. We have designed this unit to provide you with years of trouble-free
heating enjoyment.
READ THIS MANUAL IN ITS ENTIRERTY! If you do not understand any of the safety or hazardous warnings
contained in this manual, or have questions or concerns about the installation, operation, maintenance or
service of this heater, or any other questions or concerns relating to this heater, you MUST CALL THE
FACTORY at the telephone number noted on the front cover of this manual or as detailed on the rating
plate on the heater before operating this heater. Store this manual in a location near the heater, for future
reference. Make sure installation is performed by well qualified, licensed contractors in the required field of
work. If in doubt, DO NOT allow unit to be installed.
DO NOT park vehicles or place combustible objects close to the heater other than specified on the Clearance
to Combustible chart located in this manual and on the heater. Failure to observe the clearance to
combustibles can result in property damage, injury or death.
IMPORTANT NOTICE: The installation portion of these instructions are for the use of qualified individuals
specially trained, licensed and experienced in the installation of this type of equipment and related system
components.
NOTE: - The words "shall" or "must" indicate a requirement which is essential to satisfactory and safe
performance.
GENERAL HAZARD WARNING: The heater and related gas piping, fitting & wiring must be installed
by individuals or firms qualified, licensed and specially trained and experienced in installation of this
type of equipment and related system components.
Only persons who can understand and follow the instructions shall install or service this heater.
Persons not qualified shall not install this equipment nor interpret these instructions.
Failure to comply with the precautions and instructions provided with this heater can result in death,
serious bodily injury and property loss or damage from hazards of fire, explosion, burn, asphyxiation,
carbon monoxide poisoning or electrical shock.
WARNING: Installation and repair should be done by a qualified service person. The heater should be
inspected before use and at least annually by a qualified service person and prior to heating season.
Heaters used in dusty locations such as brooder barns, sawmills, woodworking shops, etc. will require
maintenance on a more regular basis and more frequent cleaning may be required as necessary. It is
imperative that the control compartments, burner(s) and circulating air passageways of the appliance
be kept clean. Periodic examination of the venting system is to be performed.
No one should work on a heater unless they are a licensed/qualified gas fitter or contractor. For all
repairs, parts MUST originate from the manufacturer of this heater in order not to void CGA/AGA
certification. Safety devices are not allowed to be rendered inoperative and left unattended as this
action can cause property damage, injury or death. Failure to do so will void your warranty.

SR-SERIES
2
WARNING: Do not store or use halogen-emitting substances in the vicinity of this heater. Such
substances include chlorine based cleaners and swimming pool chemicals, water softening chemicals,
de-icing salts and chemicals, cleaning solvents such as carbon tetrachloride or perchloroethylene,
halogen type refrigerants, printing inks, paint and paint removers, varnishes, hydrochloric acid,
cements and glues, and masonry acid washing materials, The air used by the burner for combustion
must be free of halogens to avoid possible corrosion to the heating surfaces, which could result in
asphyxiation, fire and/or death.
WARNING: Children and adults should be alerted to the hazards of high surface temperatures and
should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same place as the heater.
Clothing or other flammable materials should not be hung from the heater, or placed on or near the
heater.
Any safety screen, guard or other protective device removed for servicing a heater must be replaced
prior to operating the heater.
Do not use this appliance if any part has been under water. Immediately call a qualified service
technician to inspect the appliance and to replace any part of the control system and any gas control
which has been under water.
Ne pas se server de cet appareil sil a été plongé dans I ‘eau, complètement ou en partie, Faire inspecter
I’ appareil par un technicien qualifié et remplacer toute partie du système de control et toute
commande qui ont été plongée dans I’ eau.

SR-SERIES
3
2.0 INSTALLER RESPONSIBILITY
WARNING:
FIRE OR EXPLOSION HAZARD
The heater and related gas piping and wiring must be installed only by individuals or firms well qualified and
licensed in the required field of work.
Read and understand this manual in its entirety BEFORE you install this heater. If you have any questions call
your local representative. Verify that the fuel on the installation site is the same as what is required for this
heater. Check heater for damage or missing parts. If damage has occurred, notify carrier or point of purchase
at once for reconciliation of damaged goods. We are not responsible for transit damage. Do not install if
heater is damaged.
If you do not understand any of the safety or hazardous warnings contained in this manual, or have
questions or concerns about the installation, operation, maintenance or service of this heater, or any other
questions or concerns relating to this heater, you MUST CALL THE FACTORY at the telephone number noted
on the front cover of this manual or as detailed on the rating plate on the heater before operating this
heater.
Verify that model, input & length is what was ordered and is appropriate for installation. If heater is too small
for the heating load of the building, property damage can occur due to freezing. If unit is too large, severe
heat damage call occur to the building and/or its contents, fire, explosion, injury or death. If in doubt compare
heat loss of building with unit on site. If you are unable to calculate heat loss, call your local representative
for assistance.
Installation shall be in accordance with local codes. (See ‘CODE COMPLIANCE’).
If installation requires tilting, DO NOT over tilt the unit. Units are certified for installations up to 45°; however
the maximum recommended tilt is 25°.
Install unit according to the “Clearance to Combustibles” for that particular heater and type of installation.
Make sure that clearances are maintained from vehicles parked below or in front of heater. Take into
consideration hoists. Failure to do so could result in property damage, injury or death.
Make sure unit is adequately suspended from ceiling or roof. Select hanging location that has adequate
strength to support heater.
If combustion air is contaminated or if there is a negative air pressure in the building, install outside air for
combustion (See pages 47 & 48 titles “Optional Outside Ah”).
If unit is to be sidewall vented, use part #5200210 (Sidewall Vent Kit). Make sure vent cap is past eave. (See
pages 49 - 52 titled “VENTING”).
Do not render safety devices inoperable. Make sure gas line and/or service have adequate capacity for the
increased load of heater.

SR-SERIES
4
3.0 CODE COMPLIANCE
Installation shall be in accordance with local building codes, or in the absence of local codes, in accordance
with:
FUEL SUPPLY:
CANADA: Natural Gas and Propane Installation Code, CSA B149.1 or latest edition.
USA: National Fuel Gas Code, ANSI Z223.1/NFPA 54, or latest edition.
ELECTRICAL GROUNDING:
CANADA: Canadian Electrical Code, CSA C22.1 or latest edition.
USA: National Electrical Code, ANSI/NFPA 70 or latest edition
In Canada: Electrical equipment and wiring shall comply with the applicable provisions of the current
Canadian Electrical Code, CAN/CSA C22.1, Part I and Part II, and CAN/CSA C22.2 No.3, Electrical
features of Fuel Burning Equipment.
PUBLIC GARAGE INSTALLATION:
Adequate clearances must be maintained according to the following standards:
CANADA: Natural Gas and Propane Installation Code, CSA B149.1 or latest edition.
USA: Parking Structures, ANSI/NFPA 88A or the standard for Repair Garages, ANSI/NFPA 88B or latest
edition.
AIRCRAFT HANGERS:
Adequate clearances must be maintained according to the following standards:
CANADA: Enforcing Authority.
USA: Aircraft Hangers, ANSI/NFPA 409
Check line and manifold pressure with a manometer to confirm unit is set according to the specification on
the rating plate. Perform check with all gas-fired appliances operating. (See pages 67, 73 & 74 for further
details).
Provide adequate accessibility clearances for servicing.
Leave copy of this manual with owner (or a copy) for future reference.
DO NOT INSTALL THIS UNIT IN RESIDENTIAL SPACES
HEATER OPERATION NOTE: Heater will have a higher heat output at the burner end as compared to the
exhaust end.
SPACE HEATING: As a general rule, it is suggested to locate the burner end toward the highest heat-loss area
(doors) of the space being heated. If you have any concerns or questions concerning orientation or layout of
the heater in your application, contact factory for assistance.
SPOT HEATING: On heaters with a straight line configuration as well as units that have the maximum length
of radiant tube selected for the input capacity of a given burner, there will be a noticeable and more
pronounced perception of greater heat output from the burner end of the heater as compared to the exhaust
end. As a general rule, it is suggested for spot heating applications, to use a u-tube configuration to provide
a more even source of heat. If you have any concerns or questions concerning orientation or layout of the
heater in your application. Contact factory for assistance.
NOTE: Condensation from the exhaust may occur from this heater when it starts the heating cycle. The
condensation will stop once the heater warms up. Make sure venting is sealed according to section titled
"VENTING" on page 49.

SR-SERIES
5
4.0 SPECIFICATIONS: GENERAL SPECIFICATIONS
Rating: (Input: Natural and Propane Gas)
In Canada: 0-4500' (1372 m) In USA: 0-2000' (610 m) - De-rate Above 2000' (610 m) (see page 67)
MODEL
BURNER INPUT BTU/hr
TUBE LENGTH
MIN
MAX
MIN
MAX
SR-40
N/A
40,000
10' (3 m)
20’ (6.1 m)
SR-40HL
20,000
40,000
10' (3 m)
20’ (6.1 m)
SR-40M
20,000
40,000
10' (3 m)
20’ (6.1 m)
SR-50
N/A
50,000
20' (6.1 m)
20’ (6.1 m)
SR-50HL
25,000
50,000
20' (6.1 m)
20’ (6.1 m)
SR-50M
25,000
50,000
20' (6.1 m)
20’ (6.1 m)
SR-60
N/A
60,000
20' (6.1 m)
40’ (12.2m)
SR-60HL
30,000
60,000
20' (6.1 m)
40’ (12.2m)
SR-60M
30,000
60,000
20' (6.1 m)
40’ (12.2m)
SR-75
N/A
75,000
20' (6.1 m)
40’ (12.2m)
SR-75HL
37,500
75,000
20' (6.1 m)
40’ (12.2m)
SR-75M
37,500
75,000
20' (6.1 m)
40’ (12.2m)
SR-80
N/A
80,000
20' (6.1 m)
30’
(9.14 m)
40’ (12.2m)
SR-80HL
40,000
80,000
20' (6.1 m)
30’
(9.14 m)
40’ (12.2m)
SR-80M
40,000
80,000
20' (6.1 m)
30’
(9.14 m)
40’ (12.2m)
SR-100
N/A
100,000
20' (6.1 m)
50’ (15.2m)
SR-100HL
50,000
100,000
20' (6.1 m)
50’ (15.2m)
SR-100M
50,000
100,000
20' (6.1 m)
50’ (15.2m)
SR-125
N/A
125,000
30’ (9.14m
50’ (15.2m)
SR-125HL
62,500
125,000
30’ (9.14m
50’ (15.2m)
SR-125M
62,500
125,000
30’ (9.14m
50’ (15.2m)
SR-150
N/A
150,000
40’ (12.2m)
60’ (18.3m)
SR-150HL
75,000
150,000
40’ (12.2m)
60’ (18.3m)
SR-150M
75,000
150,000
40’ (12.2m)
60’ (18.3m)
SR-175
N/A
175,000
40’ (12.2m)
70, (21.3m)
SR-175HL
87,500
175,000
40’ (12.2m)
70, (21.3m)
SR-175M
87,500
175,000
40’ (12.2m)
70, (21.3m)
SR-200
N/A
200,000
50’ (15.2m)
80’ (24.2)
SR-200HL
100,000
200,000
50’ (15.2m)
80’ (24.2)
SR-200M
100,000
200,000
50’ (15.2m)
80’ (24.2)
SR-225
SR-225HL
SR
N/A
225,000
60’ (18.3m)
80’ (24.2)
SR-225HL
125,000
225,000
60’ (18.3m)
80’ (24.2)
SR-225M
125,000
225,000
60’ (18.3m)
80’ (24.2)

SR-SERIES
6
GAS PRESSURE at MANIFOLD:
GAS:
Natural Gas:
3.5" (8.89 cm) W.C.
L.P. Gas:
10.5" (26.67 cm) W.C.
Gas Connection
Size:
0.5" (1.27 cm) N.P.T.
GAS INLET PRESSURE:
GAS:
MINIMUM:
MAXIMUM:
Natural
4.5" (11.43 cm) W.C.
14.0" (35.56 cm) W.C.
L.P.
11.5" (29.21 cm) W.C.
14.0" (35.56 cm) W.C.
Flue Connection:
4" (10.16 cm)
COMBUSTION AIR INTAKE:
40,000 TO 80,000 Btu/hr input
4" (10.16 cm)
100,000 TO 200,000 Btu/hr input
6" (15.24 cm)
ELECTRICAL RATING:
DSI Ignition
120v 60Hz
1.0 Amps
40,000 to 80,000 Btu/hr input
2.25 Amps
100,000 to 200,000 Btu/hr input
Appliance
3 Prong Plug Connection
24 Volt Low Voltage Thermostat
ELECTRICAL RATING:
Appliance, 3 prong plug connection, 24 volt low voltage thermostat.
STANDARD EQUIPMENT:
Burner control housing is pre-assembled and pre-wired; unit comes complete with the following: industry
standard gas, electrical and venting connections, balanced air rotor, thermal overload protected motor, visual
burner inspection sight glass, combustion and air proving safety switches, 3-try spark ignition control, low
voltage thermostat connection, 4" aluminized steel combustion tube, polished aluminum standard reflector,
4" mild steel radiant heat exchanger, tube couplers, joint/hanger pieces, heat economizer baffle/turbulator,
low/line voltage thermostat, and hanging chain kit.
Optional Equipment:
- Side Reflectors
- Stainless Steel Construction
- Aluminized Steel Tube
- 90° Elbow Kit
- Side Wall Vent Kit
- Thermostat
- 180° U-Bend Kit
- Outdoor Installation Kit

SR-SERIES
7
5.0 DIMENSIONS
SIDE VIEW
Figure 1. EQUIPMENT DIMENSION
Table of Dimensions:
UNITS
DIMENSION "A" LENGTH
BURNER INPUT:
MIN
MAX
40,000 Btu/hr
10'-4" (3.15 m)
20’-4” (6.4 m)
50,000 Btu/hr
20'-4" (6.4 m)
20’-4” (6.4 m)
60,000 Btu/hr
20'-4" (6.4m)
40’-4” (12.3 m)
75,000 Btu/hr
20'-4" (6.4m)
40’-4” (12.3 m)
80,000 Btu/hr
20'-4" (6.4m)
40’-4” (12.3 m)
100,000 Btu/hr
20'-4" (6.4m)
50’-4” (15.3m)
125,000 Btu/hr
30’-4” (9.25m)
50’-4” (15.3m)
150,000 Btu/hr
40’-4” (12.3m)
60’-4” (18.4m)
175,000 Btu/hr
40’-4” (12.3m)
70’-4” (21.5m)
200,000 Btu/hr
50’-4” (15.3m)
80’-4” (24.5m)
225,000 Btu/hr
60’-4” (18.4m)
80’-4” (24.5m)

SR-SERIES
8
6.0 INSTALLATION CLEARANCES AND CLEARANCE TO COMBUSTIBLES
Installation of overhead heaters in garages or hangars MUST meet the requirements for bottom (below)
clearances detailed in CANADA: Natural Gas and Propane Installation Code, CSA B149.1 or latest edition or
USA: National Fuel Gas Code, ANSI Z223.1/NFPA 54, or latest edition.
WARNING: In all situations, clearances to combustibles must be maintained. Minimum clearance
from heater must be maintained from vehicles parked below heater. The posting of signs may be
required in storage areas referring to clearances to combustibles to the heater and/or limiting the
stacking height of stored Items near the heater specifying a maximum height. Clearances are not for
use in four (4) sided enclosures. Certain materials or items, when stored under the heater, will be
subjected to radiant heat and could be seriously damaged.
WARNING:The stated clearance to combustibles represents a surface temperature of 90°F (32°C)
above room temperature. Building material with low heat tolerance (such as plastics, vinyl siding,
canvas, tri-ply, etc) may be subject to degradation at lower temperatures. It is the installer's
responsibility to assure that adjacent materials are protected from degradation. When in doubt, check
heat tolerance of building material(s) with their manufacturer.
END CLEARANCES
(BURNER HEAD END)
Minimum clearances from air intake end of burner head to object is 12" (30.5 cm).
Provide adequate accessibility clearances for servicing and proper operation. Do not install unit in such a
manner that the combustion air entering the heater is reduced in any manner
OUTDOOR APPLICATIONS ONLY
UNVENTED
Figure 2. UNVENTED CLEARANCES
VENTED
Figure 3. VENTED CLEARANCES

SR-SERIES
9
6.1 CLEARANCE TO COMBUSTIBLES FOR SPACE HEATING AND BROODER INSTALLATION
WARNING: In all situations, clearances to combustibles must be maintained. Minimum clearance
from heater must be maintained from vehicles parked below heater. The posting of signs may be
required in storage areas referring to clearances to combustibles to the heater and/or limiting the
stacking height of stored Items near the heater specifying a maximum height. Clearances are not for use
in four (4) sided enclosures. Certain materials or items, when stored under the heater, will be subjected
to radiant heat and could be seriously damaged.
WARNING:The stated clearance to combustibles represents a surface temperature of 90°F (32°C)
above room temperature.Building material with low heat tolerance (such as plastics, vinyl siding, canvas,
tri-ply, etc…) may be subject to degradation at lower temperatures. It is the installer's responsibility to
assure that adjacent materials are protected from degradation. When in doubt, check heat tolerance of
building material(s) with their manufacturer.
INSTALLATION TYPE 1 - (inches) (cm)
INSTALLATION TYPE 2 –(inches) (cm)
Input*
A
B
C
D
Input*
A
B
C
D
40
6" (16cm)
12" (31cm)
36" (92cm)
12" (31cm)
40
6" (16cm)
12" (31cm)
36" (92 cm)
36" (92 cm)
50
6" (16cm)
12" (31cm)
36" (92cm)
12" (31cm)
50
6" (16cm)
12" (31cm)
36" (92 cm)
36" (92 cm)
60
6" (16cm)
15” (39cm)
44” (112cm)
15” (39cm)
60
6" (16cm)
12" (31cm)
44” (112cm)
36" (92 cm))
75
6" (16cm)
20” (51cm)
50” (127cm)
20” (51cm)
75
6" (16cm)
12" (31cm)
50” (127cm)
36" (92 cm)
80
6” (16cm)
20” (51cm)
53” (135cm)
20” (51cm)
80
6" (16cm)
20” (51cm)
53” (135cm)
40” (102cm)
100
6” (16cm)
22” (56cm)
55” (140cm)
22” (56cm)
100
6" (16cm)
22” (56cm)
55” (140cm)
40” (102cm)
125
6” (16cm)
22” (56cm)
55” (140cm)
22” (56cm)
125
6" (16cm)
22” (56cm)
55” (140cm)
40” (102cm)
150
6” (16cm)
24” (70cm)
60” (152cm)
24” (70cm)
150
6" (16cm)
24” (70cm)
60” (152cm)
40” (102cm)
175
6” (16cm)
24” (70cm)
65” (152cm)
24” (70cm)
175
6" (16cm)
24” (70cm)
65” (165cm)
40” (102cm)
175+20’
**
6” (16cm)
20” (51cm)
45” (115cm)
20” (51cm)
175+20’
**
6” (16cm)
16” (41cm)
45” (115cm)
36" (92 cm)
200
225
6” (16cm)
27” (69cm)
65” (165cm)
27” (69cm)
200
225
6” (16cm)
27” (69cm)
65” (165cm)
40” (102cm)
200
225+20’
**
6” (16cm)
20” (51cm)
45” (115cm)
20” (51cm)
200
225+20’
**
6" (16cm)
16” (41cm))
45” (115cm)
36" (92 cm)
Figure 4. STANDARD REFLECTOR
Figure 5. ONE SIDE REFLECTOR
*per 1,000 Btu/hr input ** Clearance 20’ (6.1m) downstream from burner
D
C
A
B

SR-SERIES
10
6.2 CLEARANCE TO COMBUSTIBLES FOR SPACE HEATING AND BROODER INSTALLATION
WARNING: In all situations, clearances to combustibles must be maintained. Minimum clearance
from heater must be maintained from vehicles parked below heater. The posting of signs may be
required in storage areas referring to clearances to combustibles to the heater and/or limiting the
stacking height of stored Items near the heater specifying a maximum height. Clearances are not for use
in four (4) sided enclosures. Certain materials or items, when stored under the heater, will be subjected
to radiant heat and could be seriously damaged.
WARNING:The stated clearance to combustibles represents a surface temperature of 90°F (32°C)
above room temperature.Building material with low heat tolerance (such as plastics, vinyl siding, canvas,
tri-ply, etc…) may be subject to degradation at lower temperatures. It is the installer's responsibility to
assure that adjacent materials are protected from degradation. When in doubt, check heat tolerance of
building material(s) with their manufacturer.
INSTALLATION TYPE 3 - (inches) (cm)
INSTALLATION TYPE 4 –(inches) (cm)
Input*
A
B
C
D
Input*
A
B
C
D
40
6" (16cm)
15" (39cm)
53" (135 cm)
15" (39cm)
40
6" (16cm)
6" (16cm)
36" (92 cm)
36" (92 cm)
50
6" (16cm)
20" (51cm)
60" (152 cm)
20" (51cm)
50
6" (16cm)
6" (16cm)
36" (92 cm)
36" (92 cm)
60
6" (16cm)
23" (59cm)
66” (168cm)
23" (59cm)
60
6" (16cm)
6" (16cm)
44” (112cm)
44” (112cm)
75
6" (16cm)
25" (64cm)
72” (183cm)
25" (64cm)
75
6" (16cm)
6" (16cm)
50” (127cm)
50” (127cm)
80
6” (16cm)
25" (64cm)
72” (183cm)
25" (64cm)
80
6" (16cm)
6" (16cm)
53” (135cm)
53” (135cm)
100
6” (16cm)
27" (69cm)
78” (199cm)
27" (69cm)
100
6" (16cm)
6" (16cm)
55” (140cm)
55” (140cm)
125
6” (16cm)
32" (82cm)
84” (214cm)
32" (82cm)
125
6" (16cm)
6" (16cm)
55” (140cm)
55” (140cm)
150
6” (16cm)
32" (82cm)
88” (224cm)
32" (82cm)
150
6" (16cm)
6" (16cm)
60” (152cm)
60” (152cm)
175
6” (16cm)
32" (82cm)
88” (224cm)
32" (82cm)
175
6" (16cm)
6" (16cm)
65” (152cm)
65” (152cm)
175+20’
**
6” (16cm)
24" (70cm)
48” (122cm)
24" (70cm)
175+20’
**
6” (16cm)
6” (16cm)
45” (115cm)
45” (115cm)
200
225
6” (16cm)
32" (82cm)
88” (224cm)
32" (82cm)
200
225
6” (16cm)
6” (16cm)
65” (165cm)
65” (165cm)
200
225+20’
**
6” (16cm)
24" (70cm)
48” (122cm)
24" (70cm)
200
225+20’
**
6" (16cm)
6" (16cm)
45” (115cm)
45” (115cm)
Figure 6. TWO SIDE REFLECTOR
Figure 7. 25° TO 45° TILT
* per 1,000 Btu/hr input ** Clearance 20’ (6.1m) downstream from burner
D
C
A
B

SR-SERIES
11
6.3 CLEARANCE TO COMBUSTIBLES FOR SPACE HEATING AND BROODER INSTALLATION
WARNING: In all situations, clearances to combustibles must be maintained. Minimum clearance
from heater must be maintained from vehicles parked below heater. The posting of signs may be
required in storage areas referring to clearances to combustibles to the heater and/or limiting the
stacking height of stored Items near the heater specifying a maximum height. Clearances are not for use
in four (4) sided enclosures. Certain materials or items, when stored under the heater, will be subjected
to radiant heat and could be seriously damaged.
WARNING:The stated clearance to combustibles represents a surface temperature of 90°F (32°C)
above room temperature.Building material with low heat tolerance (such as plastics, vinyl siding, canvas,
tri-ply, etc…) may be subject to degradation at lower temperatures. It is the installer's responsibility to
assure that adjacent materials are protected from degradation. When in doubt, check heat tolerance of
building material(s) with their manufacturer.
INSTALLATION TYPE 5 - (inches) (cm)
INSTALLATION TYPE 6 –(inches) (cm)
Input*
A
B
C
D
Input*
A
B
C
D
40
6" (16cm)
12" (31cm)
60" (152cm)
12" (31cm)
40
6" (16cm)
6" (16cm)
51" (130 cm)
40" (102cm)
50
6" (16cm)
12" (31cm)
63" (161cm)
12" (31cm)
50
6" (16cm)
6" (16cm)
57" (145 cm)
40" (102cm)
60
6" (16cm)
12” (31cm)
63” (161cm)
12” (31cm)
60
6" (16cm)
6" (16cm)
60” (152cm)
43” (110cm)
75
6" (16cm)
12” (31cm)
69” (176cm)
12” (31cm)
75
6" (16cm)
6" (16cm)
66” (168cm)
47” (120cm)
80
6” (16cm)
20” (51cm)
69” (176cm)
20” (51cm)
80
6" (16cm)
6" (16cm)
66” (168cm)
47” (120cm)
100
6” (16cm)
22” (56cm)
76” (194cm)
22” (56cm)
100
6" (16cm)
6" (16cm)
71” (181cm)
53” (135cm)
125
6” (16cm)
22” (56cm)
79” (201cm)
22” (56cm)
125
6" (16cm)
6" (16cm)
77” (196cm)
62” (158cm)
150
6” (16cm)
24” (70cm)
84” (214cm)
24” (70cm)
150
6" (16cm)
6" (16cm)
80” (204cm)
67” (171cm)
175
6” (16cm)
24” (70cm)
86” (219cm)
24” (70cm)
175
6" (16cm)
6" (16cm)
84” (214cm)
70” (178cm)
200
225
6” (16cm)
27” (69cm)
86” (219cm)
27” (69cm
200
225
6” (16cm)
6” (16cm)
94” (214cm)
70” (178cm)
Figure 8. U-Tube Standard
Figure 9. 25° TO 45° TILT U-Tube
* per 1,000 Btu/hr input ** Clearance 20’ (6.1m) downstream from burner

SR-SERIES
12
7.0 PRE-INSTALLATION INSPECTION:
Refer to pages 13 to Error! Bookmark not defined. for packaging contents.
Inspect the shipping container and heater for any evidence of shipping damage. If heater damage is found,
notify freight carrier and file a claim.
WARNING:
IF HEATER IS DAMAGED, DO NOT INSTALL
Check that all parts and pieces are present and accounted for. Report any missing items to carrier or point of
purchase at once.
Check that overall general appearance, source of fuel required and model numbers match unit requested.
Report any discrepancy to carrier or point of purchase at once.
THOROUGHLY INSPECT THE EQUIPMENT
IMMEDIATELY UPON ARRIVAL
OUR RESPONSIBILITY FOR THIS SHIPMENT CEASED WHEN THE CARRIER SIGNED THE WAYBILL.
If goods are received short or in damaged condition, it is important that you notify the carrier and insist on a
notation of the loss or damage across the face of the freight bill; otherwise no claim can be enforced against
the transportation company.
If concealed loss or damage is discovered, notify your carrier at once and request an inspection. This is
absolutely necessary. A concealed damage report must be made within 15-days of delivery of shipment. Unless
you do this, the carrier will not entertain any claim for loss or damage. The Agent will make an Inspection and
grant a concealed damage notation. If you give the Transportation Company a clear receipt for goods that have
been damaged or lost in transit, you do so at your own risk and expense.
WE ARE WILLING TO ASSIST YOU IN EVERY POSSIBLE MANNER TO COLLECT CLAIMS FOR LOSS OR DAMAGE,
BUT THIS WILLINGNESS ON OUR PART DOES NOT MAKE US RESPONSIBLE FOR COLLECTION OF CLAIMS OR
REPLACEMENT OF MATERIAL. THE ACTUAL FILING AND PROCESSING OF THE CLAIM IS YOUR RESPONSIBILITY.
WE ARE NOT RESPONSIBLE FOR FREIGHT DAMAGED IN TRANSIT!
IF CONTENTS ARE DAMAGED:
EVEN THOUGH CARTON DOES NOT LOOK DAMAGED:
A. MAKE CLAIM TO DELIVERY CARRIER AT ONCE
B. SAVE CARTONS FOR INSPECTION BY CARRIER

SR-SERIES
13
8.0 PACKAGING CONTENTS & DESCRIPTION OF PARTS:
BURNER PACKAGE
Figure 10. BURNER PACKAGE CONTENTS

SR-SERIES
14
PIPE BOXES
Figure 11. PIPE BOX CONTENT

SR-SERIES
15
10’ (3 M) REFLECTOR PACKAGE
Figure 12. 10’ (3 M) REFLECTOR PACKAGE CONTENTS

SR-SERIES
16
15’ (4.16 M) REFLECTOR PACKAGE
Figure 13. 15’ (4.16 M) REFLECTOR PACKAGE CONTENTS
This manual suits for next models
33
Table of contents
Other Calcana Heater manuals
Popular Heater manuals by other brands

PureMate
PureMate PM1530 instruction manual

SAMUEL JACKSON
SAMUEL JACKSON Vulcain Service manual

RADSON
RADSON COSMOLEDO E Instruction

USSC
USSC Nashua 3600PB owner's manual

Olimpia splendid
Olimpia splendid CALDO CRYSTAL Instructions for installation, use and maintenance

HSS Hire
HSS Hire 56282 Operating & safety guide