ACS2 Access controller User Manual
FEATURES
Working environment:
Voltage: DC +8 V-+15 V (standard 12V)
Current: ≤ 70mA
Temperature: 0 ℃-70 ℃
Humidity: 30% -90%
5 kinds of open-door mode
card to open the door
Password to open the door
* ① card + password to open the door
* ① card + card to open the door
* ① password + password to open the door
Wiring port definition and performance:
+12 V: power supply anode
GND: power supply cathode, public land
ALM: * ① alarm output and alarm output low level
ST: * ① STATUS door magnetism terminal
BT: BUTTON go button terminal, low-level unlock
DO: * ① Weigand 26 reader data lines (data 0)
D1: * ① Weigand 26 reader data lines (data 1)
NC: normally closed relay
NO: normally open relay
Features:
* ② 500 people registered capacity, high cost
performance, digging every hardware resources.
Quick issuers mode, whether it is registered
general card or the card with a password can be
registered,
passwords input setup by cardholders their own
input in the first time
① door state detection, only after close
stable then start locking signal, preventing the
door in the swing when the latch, resulting in
on the impact of electric locking bolt.
* ① with door magnetism interface, with the
alarm when open the door violence.
Indicator:
Red light: standby
Green light: active
Yellow light: yellow light flashing means waiting for
keyboard input, always yellow light open means
under the programming mode.
SHENZHEN CAMEL SECURITY CO., LTD
www.camelsecurity.com CAMELSECURITY---YOUR TRUSTED SECURITY SYSTEM SUPPLIER
2 / 3
Wiring diagram
1.Red
2.Blac
k
3.Yello
w
4.Gray
5.Blu
e
6.Gree
n
7.Whit
e
8.Brow
n
9.Purpl
e
10.Pin
k
11.Pin
k
Power port
alarm
Door
magnetis
m
Go-of
f
butto
n
External
Card reader
Electric Lock
control
Doorbell switch
+12V
GND
ALM
ST
BT
D1
D0
NC
NO
Bell1
Bell2
Program
1:Access to use the machine:
Directly in the sensor area corresponding switch use card or enter a password + "ENT" key
2:Access control machine programming methods;
1. "ENT" key: function keys, enter the programming mode
(1) By "ENT" button, MODE (orange) lights. (2) Input five digit system password, and then "ENT"
key, a short buzzer sound, MODE (orange) lights always open, access control machine
programmed into the system state.
Note: The password length of 4-8 bit arbitrary figure, if you forget your password, please do the
hardware system initialization, the initial password is "12345"!Click commands are only in a state
of the implementation of programming, after the completion of each order must be exit
programmed state, (No. 9 orders),and then re-enter the command to run other!
1. "0" button to open the door to amend delay time (in the programming mode effective)
(1) "0" button. (2) According to "5" (for 5 seconds delay, delay here range of 1-255 seconds)
(3) By "ENT" key, buzzer gives short-sound, delay modify success.
1. "1" key, modify system password (in the programming mode effective)
(1) press "1" key (2) input five digit number passwords. (3) By "ENT" key, buzzer gives short-sound,
password modification success.
Note: The password length bit arbitrary figures for the 4-8!
1. "2" key, adding card users (in the programming mode effective)
(1) press "2" key (2) input card number or card.
(3) By "ENT" button (if by card do not need to press "ENT"), a short buzzer-sound, the success of
the registration card.
2. Card record is a comma of right side of the card that 5 numbers, by virtue of this string of
numbers, you can write off this user card!
(Recommends when users card issuers, the profile number save)
5. "2" key, adding a password-based users (in the programming mode effective) (1)press "2" key (2)
Enter the number of passwords, password length 4-8 digit (3) by "ENT" key, buzzer gives short
sound, password registered success.
Note: when registration multi- number of the password, simply in order to repeat steps (2),(3), can
register a maximum of 500 passwords.
SHENZHEN CAMEL SECURITY CO., LTD
www.camelsecurity.com CAMELSECURITY---YOUR TRUSTED SECURITY SYSTEM SUPPLIER
3 / 3
6. "3" key to delete a single user (in the programming mode effective)
(1) "3" key (2) enter the registration number or password. (3) By "ENT" key, buzzer gives short
sound, the success of user write off.
Note: The number in support of 10, 8, 5-digit, write-off of more than a card or password, simply
repeat steps (2), (3).
7. “4” key, adding card + password-type users (card + card users, password + password users with
the same type of set) (in programming mode effective)
(1) by "4" key (2) input card number or card
(3) by "ENT" button (input card then do not need to press "ENT") buzzer gives short sound, a
successful user registration.
Note: 1. card + password refer to open the door.2. User passwords setup (enter) when user use
card to open door in the first time.
3. Other Notes, please refer ' accession card users'
8. "5" button, the system initialization (in the programming mode effective)
(1) by "50" key (2) by "ENT" key, buzzer gives a bell, all user data to delete the success, the factory
password recovery password is'12345 '.
9. The introduction of System Programming mode (two kinds of methods, choose one)
(1) according to different state, on many occasions by "ENT" key, know MODE (orange) lights went
out, access control system programming exit and the machine introduced into the normal working
condition.
3、Hardware initialization (initial password is'12345 ')
(1) power off (2) Hold down the door button.(3) on electricity, and continue to hold down the
door button three seconds.
(4) Bell buzzer, initialization complete.
4、Visitors doorbell
'ESC' to make use of the doorbell button, the corresponding two pink lines for the doorbell wiring,
if there is the use of wired doorbell, you can use this button as the trigger switch of doorbell.
NOTE: The system, according to guess password protection function, when the wrong password for
the input of more than five times, the keyboard will be locked 60 seconds!

Popular IP Access Controllers manuals by other brands

Roger MC16-SVC installation manual

Roger

Roger MC16-SVC installation manual

Sielox Class Series quick start guide

Sielox

Sielox Class Series quick start guide

Interlogix ACL800SUW-BS installation manual

Interlogix

Interlogix ACL800SUW-BS installation manual

RBH Access Technologies UNC100 Hardware manual

RBH Access Technologies

RBH Access Technologies UNC100 Hardware manual

Paxton ins-30093-EX quick start guide

Paxton

Paxton ins-30093-EX quick start guide

EverFocus ERK-871 Specifications

EverFocus

EverFocus ERK-871 Specifications

CyberData 011433 Operation guide

CyberData

CyberData 011433 Operation guide

CEM Systems Compact Door Interface Unit DIU 200 specification

CEM Systems

CEM Systems Compact Door Interface Unit DIU 200 specification

InVid Tech PAR-P2TEMPTABLET user manual

InVid Tech

InVid Tech PAR-P2TEMPTABLET user manual

ZKTeco ProMA Series quick start guide

ZKTeco

ZKTeco ProMA Series quick start guide

H3C WX2880X installation guide

H3C

H3C WX2880X installation guide

ZKTeco OP-200 quick start guide

ZKTeco

ZKTeco OP-200 quick start guide

LumiRing AIR-R Pro manual

LumiRing

LumiRing AIR-R Pro manual

DNF Controls 4000CL-MAV-PBIO user manual

DNF Controls

DNF Controls 4000CL-MAV-PBIO user manual

ACTi R21CF-31 installation guide

ACTi

ACTi R21CF-31 installation guide

ZKTeco ProMA Series user manual

ZKTeco

ZKTeco ProMA Series user manual

Paradox Digiplex DGP2-ACM1 installation manual

Paradox

Paradox Digiplex DGP2-ACM1 installation manual

Solid Solicard 4000 installation guide

Solid

Solid Solicard 4000 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.