Captron CANEO SR Series User manual

CANEO
Original operating instructions
seriesSR
CANEO
Original operating instructions
seriesSR

Table of Contents
Foreword...................................................................................... 3
Safety........................................................................................... 3
Notes and symbols used..........................................................3
General safety.......................................................................... 4
Personnel qualifications............................................................4
Intended use............................................................................. 4
Reasonably foreseeable misuse.............................................. 5
General description of seriesSR.................................................. 5
Assembly......................................................................................6
Recommended screw types..................................................... 8
Maximum dimensions of the screws........................................ 8
Configuring the five-pin version................................................8
Maintenance.................................................................................9
Disassembly................................................................................. 9
Disposal......................................................................................10
Technical specifications..............................................................10
Dimensional drawings.............................................................11
Drilling pattern.............................................................................................11
Dimensional drawing bar diameter 30 - 32 mm......................................... 12
Dimensional drawing bar diameter 34 - 35 mm......................................... 13
Dimensional drawing wall mounting........................................................... 14
Connection options................................................................. 15
Connection plan......................................................................15
Manual updates..........................................................................16
Legal notice................................................................................16
Imprint.........................................................................................17

Foreword
These operating instructions are intended for technicians/installers
and operators and should be kept for future reference. Read these
operating instructions carefully and make sure that you have
fully understood the contents before installing or working with the
SENSORswitches.
Safety
Notes and symbols used
Warning notes in relation to personal injury / material damage are
formulated according to the "SAFE” principle. This means they
contain information on the type and source of the hazard, potential
consequences as well as how to avoid and avert danger. The
following hazard classifications apply in the safety notes:
DANGER
Danger designates a hazardous situation, which,
if ignored, will lead to death or serious injury. The
symbol next to the warning indicates the type
and source of the danger.
WARNING
Warning designates a hazardous situation,
which, if ignored, may lead to death or serious
injury. The symbol next to the warning indicates
the type and source of the danger.
CAUTION
Caution designates a hazardous situation, which,
if ignored, may lead to injury. The symbol next to
the warning indicates the type and source of the
danger.
en

NOTICE
Notice designates a situation, which may cause material
damages and impair the product’s function if attention is not
paid.
TIP
Tip provides additional useful information about the handling of
the product.
Symbol Meaning
4Avoiding and adverting danger in the warning note
►Instructions for action
All instructions to be followed within a procedure are
always listed in chronological order.
■List
General safety
All work on electrical systems or operating equipment may only
be carried out by a specially qualified electrician according to the
applicable electrotechnical regulations.
The safety of the system in which the SENSORswitch is integrated
is the responsibility of the operator.
Personnel qualifications
A qualified electrician is a person with suitable technical training,
expertise and experience as well as knowledge of relevant
standards, who can evaluate the work assigned to them
correspondingly and recognize potential risks.
Intended use
seriesSR was developed for use as a stop request button in
local and long-distance public transport. It can be mounted on
support bars of different diameters or on even surfaces. seriesSR is

intended for use in accordance with the items listed here, the values
from the “Technical specifications” chapter, and the values from the
product description.
■Connect only to a SELV or PELV system.
■Max. permissible power supply < 100 W
Reasonably foreseeable misuse
Any use other than as specified in the section Intended use or
extending beyond this is deemed to be improper.
The SENSORswitch is not suitable for:
■use in potentially explosive atmospheres.
■use as a safety component as per directive 2006/42/EC
■use outdoors
General description of seriesSR
The supplied stop request button can have options that differ from
those shown in this manual. This does not affect the function.
A Rod mounting
B Mounting flange
C Circuit board with
connection
D Symbol film (placed in cup)
E Cup
en

Assembly
WARNING
Improper work on electrical systems!
Electric shock can result in death or life-
threatening injuries.
4Before working on electrical systems,
disconnect them from their voltage supply
and secure them against being switched on
again.
4Work on electrical installations should be
carried out only by qualified personnel in
compliance with local and national electrical
regulations and specifications.
TIP
For optimal operation, connect the SENSORswitch to a voltage
supply that has an ohmic path or capacitive path to the body.
Requirements: Mounting surface is clean.
► Disconnect the system from its voltage supply and secure it
against being switched on again.
► Select the desired position of the SENSORswitch and "Drilling
pattern ", page 11 mark.
► Select the diameter of the holes according to the recommended
screw type and start drilling.
► Check the connection cable and plug for damage and have
replaced if necessary.
► Install the mounting flange with the recommended screws.
The base of the head of the screws must not deform during
mounting.

► Connect the electrics on the circuit
board.
► Carefully press the circuit board onto
the mounting flange until the circuit
board clicks into place.
NOTICE
The cup cannot be removed without destroying it!
4Before mounting the cup, pay attention to the orientation of
the symbol and the braille.
4The braille must be facing upward.
en

► Align the symbol and carefully press the
cup onto the mounting flange until the
cup clicks into place.
Recommended screw types
■DIN EN ISO 7045 M4
■DIN EN ISO 7049 Ø3.9 mm
■DIN 7050 C M4
Maximum dimensions of the screws
The drawing shows the
maximum dimensions of the
screws.
Configuring the five-pin version
seriesSR is configured as a three-pin version. The customer can
activate the five-pin version themselves.
NOTICE
seriesSR cannot be switched from the five-pin version
back to the three-pin version!
4Before configuring seriesSR to the five-pin version, make
sure that the five-pin version is needed.

► Apply operating voltage to
pin 2 or pin 5 (A) for at least
two seconds.
► Remove the operating
voltage from pin 2 or pin 5.
aThe circuit board is
configured as a five-pin
version.
Maintenance
With the exception of cleaning, seriesSR is maintenance-free. Clean
seriesSR with a damp microfiber cloth as needed.
NOTICE
Solvents contained in cleaning agents can attack the
plastic of the button!
4Clean the surface of the button with a neutral cleaning agent
or a damp microfiber cloth.
Disassembly
NOTICE
seriesSR cannot be removed without destroying it!
4The cup and mounting flange cannot be reused following
disassembly.
► Disconnect the system from its voltage supply and secure it
against being switched on again.
► Insert the flat head screwdriver between the cup and the
mounting flange and remove the cup with the screwdriver via
lever action.
► Loosen the screw connections and disconnect the electrical
connection.
en

Disposal
Different types of electrical and electronic components must be
recycled according to their type. All applicable statutory, state and
local laws and regulations must be complied with.
Technical specifications
Operating voltage 24 V (10 to 32 V)
Load current Max. 100 mA
Output PNP-NO
Output pulse Approx. 400 ms
LED1 White (different colors are possible with
symbol film)
LED2 Red
Reverse polarity protection Protection of all cables/lines
Short circuit protection Protected against short circuit and
overload
Voltage drop Max. 2.5 V at 100 mA
Power consumption at 24 V
with signal tone
Max. 30 mA
Max. 150 mA
Operating temperature -30°C (-22°F) to +80°C (176°F)
Storage temperature -55°C (-67°F) to +95°C (203°F)
Degree of protection IP IP40
Impact resistance IK IK08
Type of actuation Capacitive
Actuation force No actuation force required
Relative air humidity Max. 93%, non-condensing

Dimensional drawings
Drilling pattern
The hole diameter is specified for a M4 screw as an example.
For a self-tapping screw, the installer must select the appropriate
diameter.
en

Dimensional drawing bar diameter 30 - 32 mm

Dimensional drawing bar diameter 34 - 35 mm
en

Dimensional drawing wall mounting

Connection options
3-pin version 5-pin version
Plug JST, 3-pin Plug JST, 3-pin
Plug JST, 2-pin
Connection plan
3-pin
PNP-NO
+VDC
0V
3
4
1
LED1
LED2
Load
en

5-pin
LED1
LED2
+VDC / LED1
+VDC / LED2
PNP-NO
0V
+VDC
3
4
2
5
1
Load
Customer can configure themselves see Chapter , "Configuring the
five-pin version".
Manual updates
CAPTRON reserves the right to make changes to the contents of
this manual as needed. The most current version can be found on
our website www.captron.com .
Legal notice
The information contained in this document regarding sensors,
SENSORswitches, devices, applications, and software is for
informational purposes only and may be updated at any time. It is
your responsibility to ensure that your applications conform to your
specifications.
CAPTRON does not make any representations or warranties,
expressly or implied, with respect to the information, including but
not limited to its content, condition, quality, and suitability for a
particular purpose. CAPTRON rejects any liability arising from this
information and its use.
The use of CAPTRON sensors, SENSORswitches, devices,
applications, and software in life support and/or safety applications
is solely at the risk of the end consumer who purchased the product.
The end consumer further agrees to defend, indemnify, and hold
CAPTRON harmless from any damages, claims, actions, or

expenses arising from such use.
Unless stated otherwise, no licenses to CAPTRON’s intellectual
property rights are transferred, implied or otherwise.
Trademark
The CAPTRON, CANEO, and oneGRID names and logos are
registered trademarks of CAPTRON in various countries and are the
property of CAPTRON Electronic GmbH.
All other trademarks mentioned herein are the property of their
respective owners.
© 2022, CAPTRON Electronic GmbH, all rights reserved.
Imprint
The operating instructions have been authored and published by
CAPTRON Electronic GmbH
Johann-G.-Gutenberg-Straße 7
82140 Olching – Germany
Tel.: +49 (0) 8142 44 88 – 160
www.captron.com
Copyright 2023
CANEO seriesSR 1.0
en
Table of contents
Other Captron Switch manuals
Popular Switch manuals by other brands

UE
UE Field Safety System One Series Installation and maintenance instructions

Ankuoo
Ankuoo Neo Get started

THOMSON
THOMSON Grass Valley Triton TTN-BVS-0808 installation manual

Grandstream Networks
Grandstream Networks GWN7706 Quick installation guide

Barksdale
Barksdale UDS 7 operating instructions

ZyXEL Communications
ZyXEL Communications GS-105S Brochure & specs