Captron CHT3-1 User manual

CHT3
Original Operating Instructions
CHT3-1 / CHT3-2 / CHT3-A
CHT3-V / CHT3-N / CHT3-S
CHT3
Original Operating Instructions
CHT3-1 / CHT3-2 / CHT3-A
CHT3-V / CHT3-N / CHT3-S

Table of Contents
Safety........................................................................................... 3
General safety.......................................................................... 3
Notes and symbols used.......................................................... 3
Personnel qualifications............................................................5
Intended use.............................................................................5
Reasonably foreseeable misuse.............................................. 5
Technical specifications................................................................6
Connection options................................................................... 6
Connection plan........................................................................8
Drilling pattern...........................................................................9
Dimensional drawing.............................................................. 10
General description.................................................................... 11
Assembly....................................................................................12
Recommended screw types................................................... 13
Maximum dimensions of the screws...................................... 13
Maintenance...............................................................................13
Maintenance operations......................................................... 13
Clean CHT3............................................................................ 14
Disassembly............................................................................... 14
Disposal......................................................................................15
Options....................................................................................... 15
Manual updates..........................................................................15
Imprint.........................................................................................16
Product description / Product description.................................. 17

This manual has been written for technicians/installers and
operators and should be kept for future reference. Read these
operating instructions carefully and make sure that you have fully
understood the contents before installing or working with the CHT3.
TIP
Metric and imperial measurements are used in drawings.
Imperial measurements are marked with [ ].
Safety
General safety
All work on electrical systems or operating equipment may only
be carried out by a specially qualified electrician according to the
applicable electrotechnical regulations.
The safety of the system in which the SENSORswitch is integrated
is the responsibility of the operator.
Notes and symbols used
Warning notes in relation to personal injury / material damage are
formulated according to the "SAFE” principle. This means they
contain information on the type and source of the hazard, potential
consequences as well as how to avoid and avert danger. The
following hazard classifications apply in the safety notes:
DANGER
Danger designates a hazardous situation, which,
if ignored, will lead to death or serious injury. The
symbol next to the warning indicates the type
and source of the danger.

WARNING
Warning designates a hazardous situation,
which, if ignored, may lead to death or serious
injury. The symbol next to the warning indicates
the type and source of the danger.
CAUTION
Caution designates a hazardous situation, which,
if ignored, may lead to injury. The symbol next to
the warning indicates the type and source of the
danger.
NOTICE
Notice designates a situation, which may cause material
damages and impair the product’s function if attention is not
paid.
TIP
Tip provides additional useful information about the handling of
the product.
Symbol Meaning
4Avoiding and adverting danger in the warning note
►Instructions for action
All instructions to be followed within a procedure are
always listed in chronological order.
■List

WARNING
Improper work on electrical systems!
Electric shock can result in death or life-
threatening injuries.
4Before working on electrical systems,
disconnect them from their voltage supply
and secure them against being switched on
again.
4Work on electrical installations should be
carried out only by qualified personnel in
compliance with local and national electrical
regulations and specifications.
Personnel qualifications
A qualified electrician is a person with suitable technical training,
expertise and experience as well as knowledge of relevant
standards, who can evaluate the work assigned to them
correspondingly and recognize potential risks.
Intended use
The SENSORswitch is intended for use in accordance with the
items listed here, the values from the “Technical specifications”
chapter and the product description.
■Only connect the product to a limited energy source as per IEC
61010 or an NEC class 2 power supply unit.
■Source current < 4 A at maximum operating voltage.
Reasonably foreseeable misuse
The switch is not suitable for:
•use as a foot switch.
•use in potentially explosive atmospheres.
•use with inductive loads without a free-wheeling diode.
•use as a safety component as per directive 2006/42/EC.

Technical specifications
Operating voltage 24 V (16.8 to 32 V)
Load current max. 400 mA
Output pulse
dynamic
static
approx. 300 ms
Corresponds to operating time
Reverse polarity protection Protection of all cables/lines
Short circuit protection Protected against short circuit and
overload
Voltage drop max. 3 V at 400 mA
Power consumption at 24 V
with signal tone
with vibration
with signal tone and vibration
max. 30 mA
max. 70 mA
max. 130 mA
max. 200 mA
Operating temperature
dynamic
static
-30 °C (-22 °F) … +80 °C (176 °F)
0 °C (32 °F) … +55 °C (131 °F)
Degree of protection IP Front IP69K
Type of actuation Capacitive
Actuation force No actuation force required
max. altitude 2000 m above sea level
Relative air humidity max. 95%, non-condensing
Connection options
Plug
CHT3-_5_ …
Plug M8, 4-pin
CHT3-_5_ …
Plug M8, 5-pin

CHT3-_6_ …
Plug JST 2.54, 4-pin
CHT3-_6_ …
Plug JST 2.54, 5-pin
CHT3-_1_ …
Plug AMP 6.3, 4-pin
CHT3-_4_ …
Plug AMP 6.3, 4-pin
CHT3-_8_ …
Plug M12, 4-pin
CHT3-_8_ …
Plug M12, 5-pin
Strands
CHT3-_7_ …
200 mm single strands with wire end ferrules
Wire end ferrules with plastic collars DIN 46228
Wire cross-section strands 0.25 mm2

Connection plan
PNP-NO, 4-pin
+VDC
+VDC / LED1
PNP-NO
0V
3
4
2
1
LED1
LED2
brown
white
black
blue
Load
NPN-NO 4-pin
+VDC
0V / LED1
NPN-NO
0V
3
2
4
1
load
LED1
LED2
brown
black
white
blue
PNP-NO 5-pin
LED1
LED2
+VDC / LED1
+VDC / LED2
PNP-NO
0V
+VDC
3
4
2
5
1
brown
white
grey
black
blue
Load

Drilling pattern
V-assembly
CHT3-2CHT3-V

A-assembly
CHT3-1CHT3-SCHT3-NCHT3-A
Dimensional drawing
Exemplary presentation, plug M8, 4-pin

General description
The supplied SENSORswitch can have options that differ from
those shown in this manual. This does not affect the function. The
SENSORswitch is equipped with different color LEDs to indicate
operating conditions. The LEDs are actuated differently depending
on the pin configuration.

Assembly
Requirements: Mounting surface is level and clean.
► Disconnect the system from its voltage supply and secure it
against being switched on again.
► Set the desired position of the SENSORswitch and provide a
center hole of minimum Ø 50 mm to maximum Ø 58 mm.
TIP
The product description will indicate whether an A- or V-
assembly is involved.
► Position the SENSORswitch (B) in the A- or V-assembly, align
centered and vertically and mark holes (C).
► Select the diameter of the holes according to the recommended
screw type and start drilling.
► Connect the SENSORswitch (B) electrically according to the
connection plan.
► Install the SENSORswitch (B) with the recommended screws.
The screw head must not deform the mounting flange (B).
► Place cover ring (A) with
groove (D) downward and
press close to the button
surface. The cover ring
must be flush with the entire
button surface.
NOTICE
Mineral grease and oils can attack the plastic of the button!
4Do not use grease or oils to apply the cover ring (A).

Recommended screw types
■DIN EN ISO 1207 M4
■DIN EN ISO 7045 M4
■DIN EN ISO 1481 Ø3.9 mm
■DIN EN ISO 7049 Ø3.9 mm
Maximum dimensions of the screws
The drawing shows the
maximum dimensions of the
screws.
Maintenance
Maintenance operations
Carry out the following maintenance operations at the specified
intervals.

Maintenance operation as needed annually
Clean the button surface X
Check cables for intactness and firm
fit
X
Check screw connections for
tightness
X
NOTICE
Solvents contained in cleaning agents can attack the
plastic of the button!
4Clean the surface of the button with a neutral cleaning agent
or a damp microfiber cloth.
Clean CHT3
Switch off the SENSORswitch for cleaning to prevent unintentional
actuation.
NOTICE
Solvents contained in cleaning agents can attack the
plastic of the button!
4Clean the surface of the button with a neutral cleaning agent
or a damp microfiber cloth.
Disassembly
► Disconnect the system from its voltage supply and secure it
against being switched on again.
► Insert the flat head screwdriver into the groove (D) on the cover
ring (A) and remove the cover ring with the screwdriver via lever
action.
► Loosen the screw connections and disconnect the electrical
connection.

Disposal
Different types of electrical and electronic components must be
recycled according to their type. All applicable statutory, state and
local laws and regulations must be complied with.
Options
Braille characters Relief
Color variations
RAL 1023 RAL 7035 RAL 9017 RAL 3020 RAL 5017 RAL6024
Scan QR code for more information
or visit our website cht3.captron.de.
Manual updates
CAPTRON reserves the right to make changes to the contents of
this manual as needed. The most current version can be found on
our website. www.captron.com .

Product description / Product
description
Product description / Product description
This manual suits for next models
6
Table of contents
Other Captron Switch manuals
Popular Switch manuals by other brands

HP
HP 262586-B21 - IP Console Switch 3x1x16 KVM Quickspecs

Austin Hughes
Austin Hughes IP802H user manual

3Com
3Com 4007 Important notice

Cabletron Systems
Cabletron Systems 3T02-04 user guide

Panasonic
Panasonic ZEQUO 6700RE installation guide

Comnet
Comnet CNGE28FX4TX24MSPOE+ Installation and operation manual