Captron CHT3-1 User manual

CHT3
Original Operating Instructions
CHT3-1 / CHT3-2 / CHT3-A
CHT3-V / CHT3-N / CHT3-S
CHT3
Original Operating Instructions
CHT3-1 / CHT3-2 / CHT3-A
CHT3-V / CHT3-N / CHT3-S

Table of Contents
Safety........................................................................................... 3
General safety.......................................................................... 3
Notes and symbols used.......................................................... 3
Personnel qualifications............................................................5
Intended use.............................................................................5
Reasonably foreseeable misuse.............................................. 5
Technical specifications................................................................6
Connection options................................................................... 6
Connection plan........................................................................8
Drilling pattern...........................................................................9
Dimensional drawing.............................................................. 10
General description.................................................................... 11
Assembly....................................................................................12
Recommended screw types................................................... 13
Maximum dimensions of the screws...................................... 13
Maintenance...............................................................................13
Maintenance operations......................................................... 13
Clean CHT3............................................................................ 14
Disassembly............................................................................... 14
Disposal......................................................................................15
Options....................................................................................... 15
Manual updates..........................................................................15
Imprint.........................................................................................16
Product description / Product description.................................. 17

This manual has been written for technicians/installers and
operators and should be kept for future reference. Read these
operating instructions carefully and make sure that you have fully
understood the contents before installing or working with the CHT3.
TIP
Metric and imperial measurements are used in drawings.
Imperial measurements are marked with [ ].
Safety
General safety
All work on electrical systems or operating equipment may only
be carried out by a specially qualified electrician according to the
applicable electrotechnical regulations.
The safety of the system in which the SENSORswitch is integrated
is the responsibility of the operator.
Notes and symbols used
Warning notes in relation to personal injury / material damage are
formulated according to the "SAFE” principle. This means they
contain information on the type and source of the hazard, potential
consequences as well as how to avoid and avert danger. The
following hazard classifications apply in the safety notes:
DANGER
Danger designates a hazardous situation, which,
if ignored, will lead to death or serious injury. The
symbol next to the warning indicates the type
and source of the danger.

WARNING
Warning designates a hazardous situation,
which, if ignored, may lead to death or serious
injury. The symbol next to the warning indicates
the type and source of the danger.
CAUTION
Caution designates a hazardous situation, which,
if ignored, may lead to injury. The symbol next to
the warning indicates the type and source of the
danger.
NOTICE
Notice designates a situation, which may cause material
damages and impair the product’s function if attention is not
paid.
TIP
Tip provides additional useful information about the handling of
the product.
Symbol Meaning
4Avoiding and adverting danger in the warning note
►Instructions for action
All instructions to be followed within a procedure are
always listed in chronological order.
■List

WARNING
Improper work on electrical systems!
Electric shock can result in death or life-
threatening injuries.
4Before working on electrical systems,
disconnect them from their voltage supply
and secure them against being switched on
again.
4Work on electrical installations should be
carried out only by qualified personnel in
compliance with local and national electrical
regulations and specifications.
Personnel qualifications
A qualified electrician is a person with suitable technical training,
expertise and experience as well as knowledge of relevant
standards, who can evaluate the work assigned to them
correspondingly and recognize potential risks.
Intended use
The SENSORswitch is intended for use in accordance with the
items listed here, the values from the “Technical specifications”
chapter and the product description.
■Only connect the product to a limited energy source as per IEC
61010 or an NEC class 2 power supply unit.
■Source current < 4 A at maximum operating voltage.
Reasonably foreseeable misuse
The switch is not suitable for:
•use as a foot switch.
•use in potentially explosive atmospheres.
•use with inductive loads without a free-wheeling diode.
•use as a safety component as per directive 2006/42/EC.

Technical specifications
Operating voltage 24 V (16.8 to 32 V)
Load current max. 400 mA
Output pulse
dynamic
static
approx. 300 ms
Corresponds to operating time
Reverse polarity protection Protection of all cables/lines
Short circuit protection Protected against short circuit and
overload
Voltage drop max. 3 V at 400 mA
Power consumption at 24 V
with signal tone
with vibration
with signal tone and vibration
max. 30 mA
max. 70 mA
max. 130 mA
max. 200 mA
Operating temperature
dynamic
static
-30 °C (-22 °F) … +80 °C (176 °F)
0 °C (32 °F) … +55 °C (131 °F)
Degree of protection IP Front IP69K
Type of actuation Capacitive
Actuation force No actuation force required
max. altitude 2000 m above sea level
Relative air humidity max. 95%, non-condensing
Connection options
Plug
CHT3-_5_ …
Plug M8, 4-pin
CHT3-_5_ …
Plug M8, 5-pin

CHT3-_6_ …
Plug JST 2.54, 4-pin
CHT3-_6_ …
Plug JST 2.54, 5-pin
CHT3-_1_ …
Plug AMP 6.3, 4-pin
CHT3-_4_ …
Plug AMP 6.3, 4-pin
CHT3-_8_ …
Plug M12, 4-pin
CHT3-_8_ …
Plug M12, 5-pin
Strands
CHT3-_7_ …
200 mm single strands with wire end ferrules
Wire end ferrules with plastic collars DIN 46228
Wire cross-section strands 0.25 mm2

Connection plan
PNP-NO, 4-pin
+VDC
+VDC / LED1
PNP-NO
0V
3
4
2
1
LED1
LED2
brown
white
black
blue
Load
NPN-NO 4-pin
+VDC
0V / LED1
NPN-NO
0V
3
2
4
1
load
LED1
LED2
brown
black
white
blue
PNP-NO 5-pin
LED1
LED2
+VDC / LED1
+VDC / LED2
PNP-NO
0V
+VDC
3
4
2
5
1
brown
white
grey
black
blue
Load

Drilling pattern
V-assembly
CHT3-2CHT3-V

A-assembly
CHT3-1CHT3-SCHT3-NCHT3-A
Dimensional drawing
Exemplary presentation, plug M8, 4-pin
This manual suits for next models