Captron CHT3 Series User manual

CHT3
Original Operating Instructions
CHT3-4 CHT3-5
CHT3
Original Operating Instructions
CHT3-4 CHT3-5

Table of Contents
Safety........................................................................................... 3
General safety.......................................................................... 3
Notes and symbols used.......................................................... 3
Personnel qualifications............................................................5
Intended use............................................................................. 5
Reasonably foreseeable misuse.............................................. 5
Technical specifications................................................................6
Connection options................................................................... 6
Connection plan........................................................................7
Drilling pattern...........................................................................9
Dimensional drawing CHT3-4.................................................10
Dimensional drawing CHT3-5.................................................11
General description.................................................................... 11
Assembly....................................................................................12
Maintenance...............................................................................13
Maintenance operations......................................................... 13
Disassembly............................................................................... 14
Disposal......................................................................................14
Manual updates..........................................................................14
Imprint.........................................................................................15
Product description.................................................................... 16

This manual has been written for technicians/installers and
operators and should be kept for future reference. Read these
operating instructions carefully and make sure that you have fully
understood the contents before installing or working with the CHT3.
Safety
General safety
All work on electrical systems or operating equipment may only
be carried out by a specially qualified electrician according to the
applicable electrotechnical regulations.
The safety of the system in which the SENSORswitch is integrated
is the responsibility of the operator.
Notes and symbols used
Warning notes in relation to personal injury / material damage are
formulated according to the "SAFE” principle. This means they
contain information on the type and source of the hazard, potential
consequences as well as how to avoid and avert danger. The
following hazard classifications apply in the safety notes:
DANGER
Danger designates a hazardous situation, which,
if ignored, will lead to death or serious injury. The
symbol next to the warning indicates the type
and source of the danger.
WARNING
Warning designates a hazardous situation,
which, if ignored, may lead to death or serious
injury. The symbol next to the warning indicates
the type and source of the danger.

CAUTION
Caution designates a hazardous situation, which,
if ignored, may lead to injury. The symbol next to
the warning indicates the type and source of the
danger.
NOTICE
Notice designates a situation, which may cause material
damages and impair the product’s function if attention is not
paid.
TIP
Tip provides additional useful information about the handling of
the product.
Symbol Meaning
4Avoiding and adverting danger in the warning note
►Instructions for action
All instructions to be followed within a procedure are
always listed in chronological order.
■List

WARNING
Improper work on electrical systems!
Electric shock can result in death or life-
threatening injuries.
4Before working on electrical systems,
disconnect them from their voltage supply
and secure them against being switched on
again.
4Work on electrical installations should be
carried out only by qualified personnel in
compliance with local and national electrical
regulations and specifications.
Personnel qualifications
A qualified electrician is a person with suitable technical training,
expertise and experience as well as knowledge of relevant
standards, who can evaluate the work assigned to them
correspondingly and recognize potential risks.
Intended use
The SENSORswitch is intended for use in accordance with the
items listed here, the values from the “Technical specifications”
chapter and the product description.
■Only connect the product to a limited energy source as per IEC
61010 or an NEC class 2 power supply unit.
■Source current < 4 A at maximum operating voltage.
Reasonably foreseeable misuse
The switch is not suitable for:
•use as a foot switch.
•use in potentially explosive atmospheres.
•use with inductive loads without a free-wheeling diode.
•use as a safety component as per directive 2006/42/EC.

Technical specifications
Operating voltage 24 V (16.8 to 32 V)
Load current max. 400 mA
Output pulse
dynamic
static
Approx. 300 ms
Corresponds to operating time
Reverse polarity protection Protection of all cables/lines
Short circuit protection Protected against short circuit and overload
Voltage drop max. 3 V at 400 mA
Power consumption at 24 V
with vibration
max. 30 mA
max. 130 mA
Operating temperature
dynamic
static
-30 °C (-22 °F) … +80 °C (176 °F)
0 °C (32 °F) … +55 °C (131 °F)
Degree of protection IP Front IP69K
Type of actuation Capacitive
Actuation force No actuation force required
max. altitude 2000 m above sea level with "CSA listing"
Relative air humidity max. 95%, non-condensing
Connection options
Plug
CHT3-_5_ …
Plug M8, 4-pin
CHT3-_5_ …
Plug M8, 5-pin

CHT3-_8_ …
Plug M12, 4-pin
CHT3-_8_ …
Plug M12, 5-pin
Strands
CHT3-_7_ …
200 mm single strands with wire end ferrules
Wire end ferrules with plastic collars DIN 46228
Wire cross-section strands 0.25 mm2
Connection plan
PNP-NO, 4-pin
+VDC
+VDC / LED1
PNP-NO
0V
3
4
2
1
LED1
LED2
brown
white
black
blue
Load

PNP-NO 4-pin with tactile feedback
+VDC
+VDC / LED1
PNP-NO
0V
3
4
2
1
LED1
LED2
brown
white
black
blue
MLoad
PNP-NO 5-pin
LED1
LED2
+VDC / LED1
+VDC / LED2
PNP-NO
0V
+VDC
3
4
2
5
1
brown
white
grey
black
blue
Load

Drilling pattern

Dimensional drawing CHT3-4...
CHT3-4...

Dimensional drawing CHT3-5...
General description
The supplied switch can have options that differ from those shown
in this manual. This does not affect the function.
The CHT3 is equipped with 16 LEDs to indicate operating

conditions. Optionally, the SENSORswitch provides a tactile or
acoustic feedback when actuated.
Assembly
WARNING
Improper work on electrical systems!
Electric shock can result in death or life-
threatening injuries.
4Before working on electrical systems,
disconnect them from their voltage supply
and secure them against being switched on
again.
4Work on electrical installations should be
carried out only by qualified personnel in
compliance with local and national electrical
regulations and specifications.
Requirements: Mounting surface is level and clean.
► Disconnect the system from its voltage supply and secure it
against being switched on again.
► Set the desired position of the SENSORswitch and drill the hole
according to the drilling pattern.
► Unscrew the lock nuts (B) from the SENSORswitch (A).
► Insert the SENSORswitch into the prepared hole and screw the
lock nuts (B) back on.
► Position the SENSORswitch (A) and tighten the lock nuts with
max. 1 Nm.
► Connect the SENSORswitch electrically according to the
connection plan.

Maintenance
Maintenance operations
Carry out the following maintenance operations at the specified
intervals.
Maintenance operation as needed annually
Clean the button surface X
Check cables for intactness and firm
fit
X
Check screw connections for
tightness
X
NOTICE
Solvents contained in cleaning agents can attack the
plastic of the button!
4Clean the surface of the button with a neutral cleaning agent
or a damp microfiber cloth.

Disassembly
► Disconnect the system from its voltage supply and secure it
against being switched on again.
► Disconnect the electrical connection and remove the lock nuts.
Disposal
Different types of electrical and electronic components must be
recycled according to their type. All applicable statutory, state and
local laws and regulations must be complied with.
Manual updates
CAPTRON reserves the right to make changes to the contents of
this manual as needed. The most current version can be found on
our website www.captron.com .
Scan QR code for more information
or visit our website cht3.captron.com.

Product description
Product description
Other manuals for CHT3 Series
1
This manual suits for next models
3
Table of contents
Other Captron Switch manuals
Popular Switch manuals by other brands

Digisol
Digisol DG-GS1550 Management guide

Network Technologies
Network Technologies VEEMUX SM-8X4-HDA Installation and operation manual

D-Link
D-Link DGS-3630 SERIES Hardware installation guide

LEGRAND
LEGRAND 4 226 81 Installation and user manual

Ayre
Ayre EX-8 owner's manual

ATEN
ATEN Master View CS-74A user manual