Safety Attention
a) Important Safety Instructions
• Be sure to read the user manual thoroughly prior to use and follow instructions for usage.
• After using or before cleaning the product, ensure the power is disconnected.
• Use the heating function with caution to avoid serious burns.
• If unsupervised, do not apply the product to insensitive or over-sensitive skin or to body parts with
poor circulation.
• Always ensure children or people with disabilities are supervised when using the product.
• Do not use undercover eg. under a pillow or blanket as this could cause fire, electric shock or
malfunction from overheating.
• Please stop using immediately if you feel uncomfortable.
• Do not use if the power cord or plugs are damaged - contact the service centre for inspection
and repair.
• Do not use spare parts that have not been recommended by the manufacturers.
• Do not insert or drop objects into any opening on the product.
• Always switch the massager off before disconnecting the power.
• This product cannot be used for self-diagnosis or treatment - please visit a healthcare professional
for this.
b) Use Environment
• Do not use the product in a wet or dusty environment in order to avoid product failure.
• Do not use this product at temperatures over 40º.
• Do not use the product outdoors.
• Do not use the product next to an electric heater or stove or in direct sunlight.
Product Specifications (DL08130)
Rated Voltage 220V
Rated Power 45W
Standards
GB 4 706.1-2005
GB 4 706.1-2008
Timer 15 minutes

www.careco.co.uk CareCo, Hubert Road, Brentwood, Essex, CM14 4JE
Zest Infrared Foot Massager - DL08130
c) Please consult your doctor before using this product if you have the following situations:
• Receiving medical treatment or experiencing physical discomfort
• Suffering from hypertension, heart disease, cerebral arteriosclerosis, and cerebral thrombosis
• Suffering from cancer
• Pregnant or menstruating
• Suffering from osteoporosis
• Using a pacemaker or implantable medical devices
• Suffering from acute diseases
• Please Note: This product is not suitable for minors
d) Buttons
• Do not operate the button with wet hands and keep the buttons away from water or other liquid.
• Do not fall asleep when using the product.
• Do not use this product when you are drunk or feeling uncomfortable.
• Do not use this product for longer than 30 minutes.
• Do not use if the product’s cloth cover has been damaged.
• Do not use the product one hour before and after eating so as to avoid adverse effects.
• Do not enable the heating function when the product is being used in a low room temperature. It is
recommended that you should gradually adjust the temperature to a normal range before
enabling heating.
• If the product is used immediately after being transferred from a cold environment to a warm
environment, the accumulation of water vapor inside the product may affect the normal operation of
the product or even cause mechanical failure. You are suggested to put the product in a normal room
temperature for 1 hour before use.
Maintenance
a) Storage
• The product should be stored in its box in dry, well-ventilated and cool conditions when it is not in use.
• Do not hang the product with the cord.
• Avoid scratching by sharp objects on the surface of the product.
• Do not put the product in direct sunlight or under condition of high temperature.
b) Cleaning
• Make sure the power button is off and unplug the power cord before cleaning.
• Use a dry cloth to clean the surface of the product.
• Do not use corrosive detergents, such as benzene or thinner, to clean the product.

www.careco.co.uk CareCo, Hubert Road, Brentwood, Essex, CM14 4JE
Zest Infrared Foot Massager - DL08130
c) Maintenance
• Keep the product clean and away from high humidity conditions.
• Please use a dust cover (not included in the box) to cover the product to prevent dust from coming
into it if it is not used for a long period of time.
Product Components
1. Central Surface: four independent buttons—controlling the product’s settings and functions
2. Central Massager Pad: Scratching—Acupressure on the arches with heating.
3. Front Massager Pad: Roller Kneading—Acupressure on the front soles
4. Rear Massager Pad: Push Kneading—Acupressure on the heels
5. Interior airbag—Air pressure on the insteps
6. Removable and washable fabric cover—cleaning
7. Bottom: Cord Wrap—keeps things tidy
Features and use of Diagram
Product Features
The modern egg-shaped design makes the product
lightweight and portable;
• A variety of functions including scratching, roller kneading
and push kneading acupressure, air pressure and heating;
• Massager pad that provides all-round massage and deep
acupressure to relax and relieve tension in the feet;
• Removable and washable cover for keeping clean;
• Cord wrap for added convenience.
Settings
a) Before use
• Check the product for any damage.
• Ensure a stable and comfortable use environment.
b) Use
• Untie the power cord and connect to power of 220V/50Hz
Default Settings:

www.careco.co.uk CareCo, Hubert Road, Brentwood, Essex, CM14 4JE
Zest Infrared Foot Massager - DL08130
Display
Timer Button: To set massage duration on timer.
Mode Button: This product provides two modes of massage to switch between.
Intensity Button: Controls the massage intensity. Mode 1 = LOW INTENSITY
Mode 2 = HIGH INTENSITY
Heating Button: When the product is turned on, push this button to control the heating
independently with a red light indicator (The heating is on in default).
Power Button: To turn on/off.
Warranty
Your CareCo branded product is under warranty to be free from defects in material and workmanship
for one year from date of purchase. This warranty expresses our confidence in the workmanship and
materials used for our products. In the event of a defect covered by this warranty, CareCo will, at our
discretion, replace the product or supply parts to remedy. This warranty does not cover device failure due
to owner misuse or negligence, or due to normal wear and tear. The warranty does not extend to non-
durable parts, such as rubber accessories, which are subject to normal wear and tear and require periodic
replacement. If you have any queries please contact CareCo.
Table of contents
Other CareCo Massager manuals