(SHEET 1 OF 3)
IS1951A(09/22)
URBANE II WALL SENSOR SOAP DISPENSER
INSTALLATION INSTRUCTIONS
Important Information
Trim kit (2-38) and body kit (1) are supplied separately.
*
Installation
2) Check that the tiling flange on the housing (1a) is flush with the
finished wall/tile face, Fig. 3. Cut if required.
i) Remove protective cover(1c) from mounting body (1b).
ii) Check that the front face of the mounting elbow(1b) is at least
5mm from the front of finished wall/tile face (See Fig. 3). 5mm
spacer (5) & 10mm spacer (6) are provided to bring the outlet
forwards if required. Spacers (5)or (6) can be placed between
item (2b) and body (1b), see Fig. 2.
iii) Insert the soap & air tubes (7) & (8) into the housing (1a) and pass
them through the hole of connection point (1a) as shown in (Fig. 2).
Wire draw/fish tape can be used by carefully tying it to the tubes and
pass through the conduits (not supplied) until the tubes come out
at the open end, Do not pull the soap tubes out forcefully. Place the
mixing valve (2a) inside the housing as shown in (Fig. 2 & 3).
iv) Fit the spring washers (3) onto the 3 screws (4).
v) Align the 3 holes on the flange (2b) with the holes on mounting
body (1b), insert screw (4) along with washer (3) through the
flange (2b) and into the threaded hole in body (1b). Then fit the
remaining screws in remaining 2 holes in similar manner and
tighten using 3mm allen key.
Roughing kit:
Fit the housing (1a) onto a noggin in the wall and secure using 4
screws (not supplied) through the holes, Fig. 1.
Before tightening, horizontal alignment must be checked by using the
flat face on the top of the housing (1a).
Important:-
1)
*The front face of the mounting plate or noggin must be parallel to the
finished wall/tile face.
To avoid damaging the mounting body(1b) , do not remove the
protective cover (1c) until installing the trim kit.
*
*The rotational alignment of the housing (1a) must be accurate.
Trim kit:
Connection point (1d) is provided for terminating standard 25mm
electrical conduit upto the control unit (16) mounted in front of the wall.
*
vi) Ensure foam seal (9a) & 'O'ring (9c) fitted on to wall cover plate (9b),
insert black sensor cable (10) from the cover plate (9) into housing(1a)
and pass it through the hole of connection point (1d) as shown in (Fig. 3).
Continue feeding the cable through the conduits(not supplied) until the
black cable end comes out the open end in front of the wall. Slide cover
plate (9) over threaded nipple (2c), position the cover plate by keeping
the sides vertical, push wall cover plate (9) firmly against the wall/tile face.
Screw the adaptor (11) onto threaded nipple (2c), using a wrench
tighten it untill the cover plate (9) is held securely against the wall/tile
face as shown in (Fig. 3). DO NOT OVERTIGHTEN.
Note: Wire draw/ fish tape can be used by carefully tying it to the cable
end and pass through the conduits(not supplied) until the cable comes
out at the open end in front of the wall.
vii) Ensure the 'O'ring fitted onto the outlet tube (12), align two holes behind
the outlet 13) with two dowel pins on wall cover plate (9), position the
outlet spout insert vertically pointing down as shown in (Fig. 3). Tighten
grub screw (14) using allen key 2.5.
Determine a suitable location for installation of control unit(16) near the
in-wall conduit exit point before proceeding with control unit mounting.
Important: Do not pull the sensor cables forcefully, as it can damage
the sensor cables or sensor connection.
The soap tube (7), air tube (8) and sensor cable item (10) in the
trim kit are 1.5m long.
*
Both water based & non-water based soap solutions can be used.
Soap solution viscosity should be within 100 to 2500 cps.
For high viscosity soap solutions the foam level knob (37) must be
set to minimum at '-' no air to enable smooth dispensing.
For water based solutions, the foam level knob (37) must be turned
anti-clockwise towards '+' max. air. '-' no air position is only suitable
for high viscosity non water based soap solutions. (See Fig. 10)
*
*Soap control unit must be primed before first use and after every
refill. Follow priming instructions, as shown in Fig.10.
The soap control unit (16) is mains powered only. Separate battery
box (25) is supplied which can be used as a battery backup.
*
The wall/tile cut-out must be 44 x 94mm to ensure enough
sealing surface for cover plate (10), Fig. 1.
The allowable in-wall range from finished wall/tile face to the
noggin is 50 - 60mm, Fig. 3.
*
*
4b) Soap control unit installation (Removable):
6) Battery box installation :
For installation into solid walls; (brick, concrete etc.)
i) Drill two 6mm holes, 40mm deep and 22mm apart vertically
as shown in Fig. 8.
ii) Insert small end of wall plugs (33) into drilled holes and tap until
flush with wall/tile face.
iii) Align the slots on bracket (34) with the holes on the wall, pass the
screws (35) through the slots and insert into the wall plugs (33).
Then tighten the screws DO NOT OVERTIGHTEN.
iv) Slide the battery box (25) onto shoulder of bracket (34).
For installation into timber stud or MDF boards:
i) Drill two holes at 22mm apart vertically to suit the self tapping
screws supplied as shown in Fig. 8.
ii)Align the slots on bracket (34) with the holes on the wall, pass the
screws (35) through the slots and insert into the timber stud.
Then tighten the screws (35). DO NOT OVERTIGHTEN.
iii)Slide the battery box (25) onto the shoulders of bracket (34).
Plug the power supply (20) into the mains and turn it ON.
Determine a suitable location for installation of battery box (25) near the
soap control unit before proceeding with battery box mounting.
iv) Fit the screws (29) and tighten, DO NOT OVERTIGHTEN.
For installation into solid walls; (brick, concrete etc.)
i) Drill two 6mm holes, 52mm apart and 40mm deep horizontally as
shown in Fig. 6.
ii)Insert small end of wall plugs (26) into drilled holes and tap until flush
with wall/tile face.
iii)Insert screws (28) into wall plugs, screw them until the head is 6mm
away from wall/tile face as shown in Fig. 6.
iv)Mount the control unit (16) onto the screws (28).
For installation into timber stud or MDF boards:
i) Drill two holes at 52mm apart horizontally to suit the self tapping
screws supplied as shown in Fig. 6.
ii)Insert screws (28) into the holes and screw them until the head is 6mm
away from wall/tile face as shown in Fig. 6.
iii)Mount the control unit (16) onto the screws (28).
5) Soap Bottle Installation (See Fig. 9)
Pass the soap bottle (32) over the tube (31) coming out of the soap
control unit (16), screw the bottle under the unit and tighten.
Optional removable bracket (supplied) allows the control unit to be lifted
off quickly for easy access to pump functions and bottle re-fill.
i) Remove the screws (29) using a phillips head screw driver.
ii) Remove the wider fixing plate (27) and put it aside.
iii)Take the narrower fixing plate (30) out of the bag, fit it at the back of
the control unit (16) by aligning the holes on the fixing plate (30) with
the holes at the back of the control unit (16). The cut-outs on the plate
should be towards the bottom, as shown in Fig.6.
3) Connections :
a) Soap tube and air tube connections, (Fig. 7 & Fig. 11):
Identify the embossings "SOAP" & "AIR under the control unit (16).
Press clip (17), slide the clip down the tube labelled "SOAP". Fit
soap tube (7) onto the boss next to embossing "SOAP". Slide the clip
up over the tube (7) and ensure clip (17) is fitted onto groove of the
boss to prevent soap tube from being removed. In the same way,
fit air tube labelled as "AIR" (8) onto the boss next to embossing "AIR".
b) Sensor cable connection, (Fig.7):
By aligning the profile of connectors (18) & (19), connect the sensor
cable (10) from cover plate (9) to the end of sensor cable (19) of
soap control unit.
c) Power cable connection:
While aligning the 'D' profile of male and female connectors, connect
male connector of power cable (21) from power supply (20) to female
connector (22) of soap control unit (16) as shown in Fig. 7. Connect
male connector (24) to female connector (23) of battery box (25).
Ensure all cable connectors are pushed in fully.
4a) Soap Control unit installation (Fixed Mounting):
For installation into solid walls; (brick, concrete etc.)
i) Drill two 6mm holes, 40mm deep and 104mm apart horizontally as
shown in Fig. 4.
ii)Insert small end of wall plugs (26) into drilled holes and tap until flush
with wall/tile face.
iii)Align the slots on fixing plate (27) with the holes on the wall, pass the
screws (28) through the slots and insert into the wall plugs (26). Then
tighten the screws. DO NOT OVERTIGHTEN.
For installation into timber stud/MDF boards:
i) Drill two holes at 104mm apart horizontally to suit the self tapping
screws supplied as shown in Fig. 4.
ii)Align the slots on fixing plate (27) with the holes on the wall, pass the
screws (28) through the slots and insert into the wall plugs (26). Then
tighten the screws. DO NOT OVERTIGHTEN.
Insert/replace 4 x 1.5V 'D' batteries following the "-" & "+" markings.
2)
1) Remove screws (36) using a phillips head screw driver then
put the screws aside, remove the cover of battery box.
7) Adding/Replacing batteries (See Fig. 8)
3)
Fit the cover back on ensuring the seal is in place and compressed.
4)
The flat head screwdriver can be used in the battery box to prise the
cover open.

(SHEET 2 OF 3)
IS1951A(09/22)
URBANE II WALL SENSOR SOAP DISPENSER
6 mm
6mm
26 28
26
28
52mm
104mm
26
27
28
16
Fig.4
Soap control unit
Installation
31
24
22
Cut-outs
Fig.6
Fixing plate Installation
30
29
Fig.5
Fixing plate removal
29
Fig.2 - Mixing valve installation
6543
2a
1a
7
8
2b
2c 1b
50 - 60mm
5mm
50 - 60mm
Fig.3 - Cover plate & outlet installation
Conduits
(not supplied)
1a 1b
In-wall range
To front face of
mounting body
Tiling flange must be cut-
flush to finished wall/tile face
In-wall range
2a
9a
9c 9b
10
2c
1113
Dowel
'O'ring
14
15
12
Insert
1d
44 mm
mm94
Fig.1 - Roughing kit installation
1a
1c
Screws
not
supplied
1d

IS1951A(09/22)
URBANE II WALL SENSOR SOAP DISPENSER
22 mm
7
8
18
16
19
22
24
17
20
23
37
38
Soap tube
Air tube
Clips
Power supply
21
SOAP
AIR
25
Slots
Shoulder
35
34
33
36
Fig.8 - Battery box installation
Fig.7- Sensor cable, soap & air tube connections
Fig.11 - Soap control unit ports
SOAP OUT
AIR OUT
SOAP IN
(SHEET 3 OF 3)
31
37 38
Fig.10 - Soap control
unit functions
FOAM LEVEL DISCHARGE TIME
TO PRIME SOAP
PRESS FOR 2 SEC
32
31
Fig.9
Soap bottle
Installation
22
24
Other Caroma Dispenser manuals
Popular Dispenser manuals by other brands

Silver King
Silver King Majestic SK10MAJ Technical manual and replacement parts list

Bobrick
Bobrick Designer Series Instructions for installation, operation, maintenance

U-Line
U-Line H-9953 manual

Piusi
Piusi MC BOX 1.5 ETL Use and maintenance manual

Graco
Graco PR70 Series repair parts

Event Furniture
Event Furniture 240VOLT Operating & safety guide