
SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com E-Mail: sale@carymart.com
Usage (with the transmitter):
The receiver can be used to control both DC 0~28V andAC 110~240V equipments.
Notice: The receiver is relay output, not DC/AC power output. Initial state of relay output terminals: Terminals B and C are Normally Open;
Terminals A and B are Normally Closed.
If you want to control DC 12V lamp, do as following:
1) Connect the live wire of the AC power supply to terminal “L / +” of receiver, and the neutral wire of the AC power supply to terminal “N / -“of
receiver.
2) Connect terminal C of receiver to the positive pole of the DC power supply , connect terminal B of receiver to the positive pole of the DC lamp,
and connect the negative pole of the DC lamp to the negative pole of the DC power supply.
If you want to controlAC 220V lamp, do as following:
1) Connect the live wire of the AC power supply to terminal “L / +” of receiver, and the neutral wire of the AC power supply to terminal “N / -“of
receiver.
2) Connect terminal C of receiver to the live wire of the AC power supply, connect terminal B of receiver to one side of the AC lamp, and connect
another side of the AC lamp to the neutral wire of the AC power supply.
Setting different control modes (We have set the receiver as Toggle control mode before delivery. If you want to use other control
modes, do as following operation):
1) Setting control mode Toggle: Connect Jumper-2.
Control mode Toggle (with transmitter CV-6): Press -> On; Press again -> Off.
Press button 1: Turn on relay of receiver 1 (connect B and C, disconnect Aand B), the lamp1 is on.
Press button 1 again: Turn off relay 1 of receiver 1 (disconnect B and C, connect Aand B), the lamp1 is off.
Press button 2: Turn on relay of receiver 2 (connect B and C, disconnectA and B), the lamp2 is on.
Press button 2 again: Turn off relay of receiver 3 (disconnect B and C, connect A and B), the lamp2 is off.
…
Press button 6: Turn on relay of receiver 6 (connect B and C, disconnect Aand B), the lamp6 is on.
Press button 6 again: Turn off relay of receiver 6 (disconnect B and C, connect A and B), the lamp6 is off.
2) Setting control mode Momentary: Connect Jumper-1.
Control mode Momentary (with transmitter CV-6): Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on relay of receiver 1 (connect B and C, disconnectA and B), the lamp1 is on.
Release button 1: Turn off relay of receiver 1 (disconnect B and C, connectA and B), the lamp1 is off.
Press and hold button 2: Turn on relay of receiver 2 (connect B and C, disconnectA and B), the lamp2 is on.
Release button 2: Turn off relay of receiver 2 (disconnect B and C, connect Aand B), the lamp2 is off.
…
Press and hold button 6: Turn on relay of receiver 6 (connect B and C, disconnectA and B), the lamp6 is on.
Release button 6: Turn off relay of receiver 6 (disconnect B and C, connectA and B), the lamp6 is off.
3) Setting control mode Latched: Disconnect Jumper-1 and Jumper-2.
Control mode Latched (with transmitter CV-6): Press -> On, another relay Off; Press another button -> Off.
Press button 1: Turn on relay of receiver 1 (connect B and C, disconnect Aand B), the lamp1 is on.
Turn off the other relays of receivers (disconnect B and C, connect Aand B), the other lamps are off.
Press button 2: Turn on relay of receiver 2 (connect B and C, disconnect Aand B), the lamp2 is on.
Turn off the other relays of receivers (disconnect B and C, connect Aand B), the other lamps are off.
…
Press button 6: Turn on relay of receiver 6 (connect B and C, disconnect A and B), the lamp 6 is on.
Turn off the other relays of receivers (disconnect B and C, connect Aand B), the other lamps are off.
Manual control terminals:
The receiver has manual control terminals, you can connect external devices, sensors, or manual switches to control the receiver.
1) Signal input:
You can connect external devices (with low level output signal) to terminals “1”, “3”, the external device’s output signal can control the receiver.
When the external device outputs low level signal to terminal “1”and “3“, turn on the relay (connect terminals B and C, disconnect terminalsAand
B).
When the external device does not output signal to terminal “1”and “3“,turn off the relay (disconnect terminals B and C, connect terminals A and
B).
2) The manual switches:
You can connect one manual switch to terminals “1”, “3”, and then you can use this manual switch to control the receiver.
When connect terminals “1”and “3”, turn on the relay (connect terminals B and C, disconnect terminalsA and B).
And when disconnect terminals “1”and “3”, turn off the relay (disconnect terminals B and C, connect terminals Aand B).
How to pair the transmitter to the receiver:
1) Press the learning button of receiver; signal LED on the receiver keeps shining. The receiver enters into status of LEARNING.
2) Press any one button on remote control. If signal LED flashes quickly 15 times and turns off, it means learning is successful.