manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Casals
  6. •
  7. Control Panel
  8. •
  9. Casals CTRL-MAX User manual

Casals CTRL-MAX User manual

Other manuals for CTRL-MAX

1

Other Casals Control Panel manuals

Casals CTRL-DPH Manual

Casals

Casals CTRL-DPH Manual

Casals CTRL-MAX2 User manual

Casals

Casals CTRL-MAX2 User manual

Popular Control Panel manuals by other brands

GENEVO PRiMA 6 installation manual

GENEVO

GENEVO PRiMA 6 installation manual

NAPCO X 255 - Programming instructions

NAPCO

NAPCO X 255 - Programming instructions

Next Systems UNIR1 230 instruction manual

Next Systems

Next Systems UNIR1 230 instruction manual

HORNER HE-XPW1E0 user manual

HORNER

HORNER HE-XPW1E0 user manual

DSC CLASSIC PC1555 instruction manual

DSC

DSC CLASSIC PC1555 instruction manual

Bosch Solution 2000 installation guide

Bosch

Bosch Solution 2000 installation guide

VRinsight MS Panel user manual

VRinsight

VRinsight MS Panel user manual

Zeiss SYCOP 3 Quick reference guide

Zeiss

Zeiss SYCOP 3 Quick reference guide

HULTSTEINS ECOFRIDGE DISPLAY user manual

HULTSTEINS

HULTSTEINS ECOFRIDGE DISPLAY user manual

Elkron C420 Programming manual

Elkron

Elkron C420 Programming manual

GST GST200-2 Installation and operation manual

GST

GST GST200-2 Installation and operation manual

Efka Variocontrol V810 instruction manual

Efka

Efka Variocontrol V810 instruction manual

RDZ PC-HRX user manual

RDZ

RDZ PC-HRX user manual

STG-BEIKIRCH MZ3 operation instruction

STG-BEIKIRCH

STG-BEIKIRCH MZ3 operation instruction

AMX AutoPatch CP-15 instruction manual

AMX

AMX AutoPatch CP-15 instruction manual

Cebora 208-10 instruction manual

Cebora

Cebora 208-10 instruction manual

Satel CA-6 KLED-S user manual

Satel

Satel CA-6 KLED-S user manual

Evolution IQ plus 800 installation manual

Evolution

Evolution IQ plus 800 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

www.casals.com
CV072018-1
CTRL-MAX
USER MANUAL AND SETUP INSTRUCTIONS
2
CV072018-1
INDEX
SCREEN
VERSION WITH INTEGRATED SCREEN
LEGEND
CHANGE OF THE SET POINT
LOCAL COMMAND
INVESTMENT MODE HEATING OR REFRIGERATION
ALARMS
p. 3
p. 3
p. 3
p. 4
p. 4
p. 4
p. 4
3
CV072018-1
1
2
3
4
5 6 7 8
9
SCREEN
VERSION WITH INTEGRATED SCREEN
LEGEND
CTRL-MAX
ON/OFF BUTTON
aTurn the unit on or
off manually
aReturn
OK BUTTON
aSelect the menu
aConfirm the value
aChange between loop
1 and loop 2, status of
the digital outputs and
controller time
aPress> 2 seconds to
access the entrances and
exits, the schedule or the
inversion of summer /
winter mode
HIGH / LOW BUTTON
aIncrease / decrease the value (setpoint)
aChange in the menu within parameter setting mode
1Loop indication: Bar 1 = loop 1, Bar 2 = loop 2
2Indication of loop temperature value 1 or 2
3Indication of heating or cooling operation mode
4Indication of the set point value
5Active digital output indication (1 to 6)
6Schedule indication
7Manual override, delay on enable function
8Ventilation On
9Control output
High/low button
OK button
On/Off button
Left button ESC
4
CV072018-1
CHANGE OF THE SETPOINT POINT
Press the“up” or“down”key to increase or decrease the set point for the current control loop.
LOCAL COMMAND
The unit can be commanded locally even if you have programmed an operating schedule to turn on or off automatically.
To turn the unit on or off
INVESTMENT MODE HEATING OR REFRIGERATION (H / C)
The investment can be made through the display, making the following sequence of steps.
1. Press the“OK”button for about 3 seconds until“SEL”appears.
2.Turn the “up” or the “down”button to“H-C”.
3. Enter the menu, press the“OK” button.
4. Switch between the“warm up” or“cool down”mode on the“up”or “down”button.
5. Confirm with “OK”
ALARMS
The controller has multiple alarms configured according to the type of device.
Here is a table of alarms that can appear on the screen and their activation conditions.
SEL
H-C
ALARM DESCRIPTION ACTIVATION CONDITION
1 Flow failure alarm in the insufflation fan When the ventilation is ON and after 30 seconds there is no
feedback from the pressure switch
2 Flow failure alarm on the return fan When the ventilation is ON and after 30 seconds there is no
feedback from the pressure switch
3 Dirty filter alarm
When the ventilation is ON and after 120 seconds the filter
switch recognizes a differential pressure greater than the set
value
4Thermal protection alarm of the electrical resistance the
coil
When at insufflation temperature it exceeds the fixed tem-
perature limit
NOTE: For the verification of the alarm, after the resolution, the OK button must be pressed.
The alarm condition persists after checking, the alarm is activated again.