www.casals.com
CV072018-1
CTRL-MAX
USER MANUAL AND SETUP INSTRUCTIONS
2
CV072018-1
INDEX
SCREEN
VERSION WITH INTEGRATED SCREEN
LEGEND
CHANGE OF THE SET POINT
LOCAL COMMAND
INVESTMENT MODE HEATING OR REFRIGERATION
ALARMS
p. 3
p. 3
p. 3
p. 4
p. 4
p. 4
p. 4
3
CV072018-1
1
2
3
4
5 6 7 8
9
SCREEN
VERSION WITH INTEGRATED SCREEN
LEGEND
CTRL-MAX
ON/OFF BUTTON
aTurn the unit on or
off manually
aReturn
OK BUTTON
aSelect the menu
aConfirm the value
aChange between loop
1 and loop 2, status of
the digital outputs and
controller time
aPress> 2 seconds to
access the entrances and
exits, the schedule or the
inversion of summer /
winter mode
HIGH / LOW BUTTON
aIncrease / decrease the value (setpoint)
aChange in the menu within parameter setting mode
1Loop indication: Bar 1 = loop 1, Bar 2 = loop 2
2Indication of loop temperature value 1 or 2
3Indication of heating or cooling operation mode
4Indication of the set point value
5Active digital output indication (1 to 6)
6Schedule indication
7Manual override, delay on enable function
8Ventilation On
9Control output
High/low button
OK button
On/Off button
Left button ESC
4
CV072018-1
CHANGE OF THE SETPOINT POINT
Press the“up” or“down”key to increase or decrease the set point for the current control loop.
LOCAL COMMAND
The unit can be commanded locally even if you have programmed an operating schedule to turn on or off automatically.
To turn the unit on or off
INVESTMENT MODE HEATING OR REFRIGERATION (H / C)
The investment can be made through the display, making the following sequence of steps.
1. Press the“OK”button for about 3 seconds until“SEL”appears.
2.Turn the “up” or the “down”button to“H-C”.
3. Enter the menu, press the“OK” button.
4. Switch between the“warm up” or“cool down”mode on the“up”or “down”button.
5. Confirm with “OK”
ALARMS
The controller has multiple alarms configured according to the type of device.
Here is a table of alarms that can appear on the screen and their activation conditions.
SEL
H-C
ALARM DESCRIPTION ACTIVATION CONDITION
1 Flow failure alarm in the insufflation fan When the ventilation is ON and after 30 seconds there is no
feedback from the pressure switch
2 Flow failure alarm on the return fan When the ventilation is ON and after 30 seconds there is no
feedback from the pressure switch
3 Dirty filter alarm
When the ventilation is ON and after 120 seconds the filter
switch recognizes a differential pressure greater than the set
value
4Thermal protection alarm of the electrical resistance the
coil
When at insufflation temperature it exceeds the fixed tem-
perature limit
NOTE: For the verification of the alarm, after the resolution, the OK button must be pressed.
The alarm condition persists after checking, the alarm is activated again.

Other manuals for CTRL-MAX

1

Other Casals Control Panel manuals

Casals CTRL-MAX2 User manual

Casals

Casals CTRL-MAX2 User manual

Casals CTRL-DPH Manual

Casals

Casals CTRL-DPH Manual

Popular Control Panel manuals by other brands

Tekmar D 270 Data brochure

Tekmar

Tekmar D 270 Data brochure

Bentel Security KYO 4 M user manual

Bentel Security

Bentel Security KYO 4 M user manual

Vimar Elvox RS17.P Installer quick guide

Vimar

Vimar Elvox RS17.P Installer quick guide

Fischer Panda P6+ manual

Fischer Panda

Fischer Panda P6+ manual

GE 45129 quick start guide

GE

GE 45129 quick start guide

Yamaha DCP1V4S-US manual

Yamaha

Yamaha DCP1V4S-US manual

Pentek VFD-ALT Owner and operational manual

Pentek

Pentek VFD-ALT Owner and operational manual

BLAUBERG Ventilatoren SE Vento Expert W user manual

BLAUBERG Ventilatoren

BLAUBERG Ventilatoren SE Vento Expert W user manual

Maxlogic ML-121X Operating and maintenance manual

Maxlogic

Maxlogic ML-121X Operating and maintenance manual

Cofem CCO122 manual

Cofem

Cofem CCO122 manual

Advantech UbiQ user manual

Advantech

Advantech UbiQ user manual

Moeller MI4 Hardware and engineering

Moeller

Moeller MI4 Hardware and engineering

Pulsar 17/40/DSPR/S/PUSTA Assembly instruction

Pulsar

Pulsar 17/40/DSPR/S/PUSTA Assembly instruction

Siemens SXL-EX datasheet

Siemens

Siemens SXL-EX datasheet

Kidde TM0058 user guide

Kidde

Kidde TM0058 user guide

Victron energy Blue Power BMV-602 instruction manual

Victron energy

Victron energy Blue Power BMV-602 instruction manual

Elkron MP500/4N Programming manual

Elkron

Elkron MP500/4N Programming manual

Honeywell Gamewell-FCI GWF-7075 Installation and operation manual

Honeywell

Honeywell Gamewell-FCI GWF-7075 Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.