USER MANUAL AND SETUP INSTRUCTIONS
2
CV072018-1
INDEX
SCREEN
VERSION WITH INTEGRATED SCREEN
LEGEND
CHANGE OF THE SET POINT
LOCAL COMMAND
INVESTMENT MODE HEATING OR REFRIGERATION
ALARMS
p. 3
p. 3
p. 3
p. 4
p. 4
p. 4
p. 4
3
CV072018-1
1
2
3
4
5 6 7 8
9
SCREEN
VERSION WITH INTEGRATED SCREEN
LEGEND
CTRL-MAX
ON/OFF BUTTON
aTurn the unit on or
off manually
aReturn
OK BUTTON
aSelect the menu
aConfirm the value
aChange between loop
1 and loop 2, status of
the digital outputs and
controller time
aPress> 2 seconds to
access the entrances and
exits, the schedule or the
inversion of summer /
winter mode
HIGH / LOW BUTTON
aIncrease / decrease the value (setpoint)
aChange in the menu within parameter setting mode
1Loop indication: Bar 1 = loop 1, Bar 2 = loop 2
2Indication of loop temperature value 1 or 2
3Indication of heating or cooling operation mode
4Indication of the set point value
5Active digital output indication (1 to 6)
6Schedule indication
7Manual override, delay on enable function
8Ventilation On
9Control output
High/low button
OK button
On/Off button
Left button ESC
4
CV072018-1
CHANGE OF THE SETPOINT POINT
Press the“up” or“down”key to increase or decrease the set point for the current control loop.
LOCAL COMMAND
The unit can be commanded locally even if you have programmed an operating schedule to turn on or off automatically.
To turn the unit on or off
INVESTMENT MODE HEATING OR REFRIGERATION (H / C)
The investment can be made through the display, making the following sequence of steps.
1. Press the“OK”button for about 3 seconds until“SEL”appears.
2.Turn the “up” or the “down”button to“H-C”.
3. Enter the menu, press the“OK” button.
4. Switch between the“warm up” or“cool down”mode on the“up”or “down”button.
5. Confirm with “OK”
ALARMS
The controller has multiple alarms configured according to the type of device.
Here is a table of alarms that can appear on the screen and their activation conditions.
SEL
H-C
ALARM DESCRIPTION ACTIVATION CONDITION
1 Flow failure alarm in the insufflation fan When the ventilation is ON and after 30 seconds there is no
feedback from the pressure switch
2 Flow failure alarm on the return fan When the ventilation is ON and after 30 seconds there is no
feedback from the pressure switch
3 Dirty filter alarm
When the ventilation is ON and after 120 seconds the filter
switch recognizes a differential pressure greater than the set
value
4Thermal protection alarm of the electrical resistance the
coil
When at insufflation temperature it exceeds the fixed tem-
perature limit
NOTE: For the verification of the alarm, after the resolution, the OK button must be pressed.
The alarm condition persists after checking, the alarm is activated again.

Other manuals for CTRL-MAX

1

Other Casals Control Panel manuals

Casals CTRL-DPH Manual

Casals

Casals CTRL-DPH Manual

Casals CTRL-MAX2 User manual

Casals

Casals CTRL-MAX2 User manual

Popular Control Panel manuals by other brands

INIM PREVIDIA COMPACT installation manual

INIM

INIM PREVIDIA COMPACT installation manual

eSSL inBIO460 Series user manual

eSSL

eSSL inBIO460 Series user manual

Zonefirst By-Pass Eliminator 24 BPE24 Installation and operating instructions

Zonefirst

Zonefirst By-Pass Eliminator 24 BPE24 Installation and operating instructions

Radionics D269 user guide

Radionics

Radionics D269 user guide

Trane Symbio CVRF installation instructions

Trane

Trane Symbio CVRF installation instructions

NuAire MRXBOX-VSC Installation & operating instructions

NuAire

NuAire MRXBOX-VSC Installation & operating instructions

Sony MKS-8010A installation manual

Sony

Sony MKS-8010A installation manual

BLUGUARD SmartBus P900-T32 Series user manual

BLUGUARD

BLUGUARD SmartBus P900-T32 Series user manual

ESAB GMH instruction manual

ESAB

ESAB GMH instruction manual

Johnson Controls Bentel Security tyco ABSOLUTA Plus Installer manual

Johnson Controls

Johnson Controls Bentel Security tyco ABSOLUTA Plus Installer manual

K-TRON K-Commander Programming manual

K-TRON

K-TRON K-Commander Programming manual

FAAC E124 manual

FAAC

FAAC E124 manual

Fröling RBG 3200 operating instructions

Fröling

Fröling RBG 3200 operating instructions

Toshiba TCB-EXS21TLE installation instructions

Toshiba

Toshiba TCB-EXS21TLE installation instructions

Satel INTEGRA Plus user manual

Satel

Satel INTEGRA Plus user manual

Xylem Bell & Gossett 4DWC instruction manual

Xylem

Xylem Bell & Gossett 4DWC instruction manual

Bosch Easy Series Selection guide

Bosch

Bosch Easy Series Selection guide

StayD MG5000 Installer setup guide

StayD

StayD MG5000 Installer setup guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.