PSR42x series
Quick Start Guide
Power distribution unit
The quick start guide gives you an overview of all the front and rear controls and
connections on the PSR42x series. It allows you to get started with the installation of
it in your project.
Front:
2) Power button LED light
Switches the LED light ON or OFF
1) USB charger
The two USB type A connectors offer
the possibility to charge various devices
such as smartphones, tablets or similar
devices. It is not designed for plugging in
USB memory devices.
3) LED dimmer
The LED light can be dimmed by turning
the dial.
1
13
5
24 4
4) Circuit breaker
If a short-circuit occurs, the circuit
breaker will automatically switch over.
2
5) Construction
The construction is made using black
powder coated aluminum tted with
steel 19” mounting ears on each side.
The total height covers a single 19”
rackspace, allowing it to be installed in
any 19” housing or equipment rack.
6) AC power lead
The mains power supply (250V AC
- 50/60Hz) is standard tted. The
connection cable has a length of 2.5
meters.
Back:
7) Power outlet
There are multiple power outlets on the
back of the PSR42x. All devices in the
same rack can be supplied with power
at this location while being protected
against overcurrent and short-circuit.
Variants
- PSR429F/B - 19” Power distributor with
9 x French (Type E - CEE7/5) power
sockets
(‘F’ versions)
- PSR429G/B - 19” Power distributor with
9 x German (Type F - CEE 7/3) power
sockets
(‘G’ versions)
- PSR428UK/B - 19” Power distributor
with 8 x UK (BS-1363) power sockets
(‘UK’ versions)
7
Picture for reference: F version
Bottom:
Specications
8) Chassis earth connection point
A chassis earth connection point is
provided for easily connecting your rack/
enclosure to mains earth, as required by
safety regulations.
General specications (F & G version)
- Rated working voltage (UN): 250V AC
50/60 Hz
- Rated load current (IR): 16A
- Maximum power load (Pmax): 4000W
General specications (UK version)
- Rated working voltage (UN): 250V AC
50/60 Hz
- Rated load current (IR): 13A
- Maximum power load (Pmax): 3250W
USB Port specications
- 2 x USB TypeA connections
- 5V / 2.1 A supply (two ports combined)
LED light specications
- Switchable ON/OFF (switch)
- Dimmable between 25% and 100%
- Max 70 lumen
8
3
CATION - SERVICING:
This product contains no user serviceable parts.
Referall servicing to qualied service personnel.
Do not perform any servicing
(unless you are qualied to)
EC DECLARATION OF CONFORMITY
This product conforms to all the essential
requirements and further relevant specications
described infollowing directives: 2014/30/EU (EMC)
and 2014/35/ EU (LVD)
WASTE ELECTRICAL AND ELECTRONIC
EQUIPMENT (WEEE)
The WEEE marking indicates that this product should
not be disposed with regular household waste at
the end of its life cycle. This regulation is created
to prevent any possible harm to the environment or
human health.
This product is developed and manufactured with
high quality materials and components which can be
recycled and/or reused. Please dispose this product
at your local collection point or recycling centre for
electrical and electronic waste. This will make sure
that it will be recycled on an environmentally friendly
manner, and will help to protect the environment in
which we all live.
These symbols warn that there are no user
serviceable parts inside the unit. Do not open the
unit. Do not attempt to service the unit yourself. Refer
all servicing to qualied personnel. Opening the
chassis for any reason will void the manufacturer’s
warranty. Do not get the unit wet. If liquid is spilled
on the unit, shut it off immediately and take it to a
dealer for service.Disconnect the unit during storms
to prevent damage.
CAUTION
The symbols shown are internationally recognized
symbols that warn about potentional hazards of
electrical products. The lightning ash with arrowpoint
in an equilateral triangle means that the unit contains
dangerous voltages. The exclamation point in an
equilateral triangle indicates that it is necessary for
the user to refer to the users manual.
CAUTION:
ALWAYS KEEP THESE INSTRUCTIONS. NEVER
THROW THEM AWAY
ALWAYS HANDLE THIS UNIT WITH CARE
HEED ALL WARNINGS
FOLLOW ALL INSTRUCTIONS
NEVER EXPOSE THIS EQUIPMENT TO RAIN,
MOISTURE, ANY DRIPPING OR SPLASHING
LIQUID. AND NEVER PLACE AN OBJECT FILLED
WITH LIQUID ON TOP OF THIS DEVICE
NO NAKED FLAME SOURCES, SUCH AS LIGHTED
CANDLES, SHOULD BE PLACED ON THE
APPARATUS
DO NOT PLACE THIS UNIT IN AN ENCLOSED
ENVIRONMENT SUCH AS A BOOKSHELF
OR CLOSET. ENSURE THERE ISADEQUATE
VENTILATION TO COOL THE UNIT. DO NOT BLOCK
THE VENTILATION OPENINGS.
DO NOT STICK ANY OBJECTS THROUGH THE
VENTILATION OPENINGS.
DO NOT INSTALL THIS UNIT NEAR ANY HEAT
SOURCES SUCH AS RADIATORS OR OTHER
APPARATUS THAT PRODUCE HEAT.
DO NOT PLACE THIS UNIT IN ENVIRONMENTS
WHICH CONTAIN HIGH LEVELS OF DUST, HEAT,
MOISTURE OR VIBRATION
THIS UNIT IS DEVELOPED FOR INDOOR USE
ONLY. DO NOT USE IT OUTDOORS
PLACE THE UNIT ONASTABLE BASE OR MOUNT
IT IN A STABLE RACK
ONLY USE ATTACHMENTS & ACCESSORIES
SPECIFIED BY THE MANUFACTURER
UNPLUG THISAPPARATUS DURING LIGHTNING
STORMS OR WHEN UNUSED FOR LONG PERIODS
OF TIME
ONLY CONNECT THIS UNIT TOAMAINS SOCKET
OUTLET WITH PROTECTIVE EARTHING
CONNECTION
THE MAINS PLUG OR APPLIANCE COUPLER
IS USEDAS THE DISCONNECT DEVICE, SO
THE DISCONNECT DEVICE SHALL BE READILY
OPERABLE
USE THEAPPARATUS ONLY IN MODERATE
CLIMATES
4

This manual suits for next models

3

Other CAYMON Power Distribution Unit manuals

CAYMON PSR429 Series User manual

CAYMON

CAYMON PSR429 Series User manual

CAYMON PSR52 Series User manual

CAYMON

CAYMON PSR52 Series User manual

CAYMON PSR529 Series User manual

CAYMON

CAYMON PSR529 Series User manual

Popular Power Distribution Unit manuals by other brands

dehn 105 525 installation instructions

dehn

dehn 105 525 installation instructions

MTT MS3707H user manual

MTT

MTT MS3707H user manual

Daxten STARLINE datasheet

Daxten

Daxten STARLINE datasheet

Alpha Smart BDFB Technical guide

Alpha

Alpha Smart BDFB Technical guide

rollease acmeda AUTOMATE MT03-0301-411005 manual

rollease acmeda

rollease acmeda AUTOMATE MT03-0301-411005 manual

Clever Electronics NPM2000 user manual

Clever Electronics

Clever Electronics NPM2000 user manual

LEGRAND DPX3 1600 manual

LEGRAND

LEGRAND DPX3 1600 manual

Raritan Dominion Px Quick setup guide

Raritan

Raritan Dominion Px Quick setup guide

Nordost QBASE REFERENCE instruction manual

Nordost

Nordost QBASE REFERENCE instruction manual

Chatsworth Products eConnect K Series user manual

Chatsworth Products

Chatsworth Products eConnect K Series user manual

Rowe PDM60 instruction manual

Rowe

Rowe PDM60 instruction manual

LEGRAND 0 281Series manual

LEGRAND

LEGRAND 0 281Series manual

CyberPower 649532893508 Specification sheet

CyberPower

CyberPower 649532893508 Specification sheet

Show Tec PSA-16A3S manual

Show Tec

Show Tec PSA-16A3S manual

Tripp Lite PDU1230 owner's manual

Tripp Lite

Tripp Lite PDU1230 owner's manual

Tinker & Rasor CI-50 quick start guide

Tinker & Rasor

Tinker & Rasor CI-50 quick start guide

Tripp Lite PDUMH15 Specification sheet

Tripp Lite

Tripp Lite PDUMH15 Specification sheet

Murrelektronik MVK-MPNIO Series manual

Murrelektronik

Murrelektronik MVK-MPNIO Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.