CBA RA-4961-DSQ User manual

RA-4961-DSQ
Wireless Outdoor PIR Sensor
Manual
•
For use with RA-4961 series receivers
•Wirelessly monitor driveways walkways
or other areas
•Up to 1 000ft (305m) transmission range*
•Programmable activation time
•
Programmable sensing range up to
40ft (12m)
•Runs on batteries for a convenient
wireless installation
•Adjustable mounting angle
* Transmission range will vary depending on installation and operating environment.
®

CBA Wireless Outdoor PIR Sensor
2SECO-LARM U.S.A., Inc.
Specifications:
Parts List:
1x Wireless Outdoor PIR Sensor
4x Screws
Dimensions:
Overvie :
Sensor
Battery
compartment
Photo
Sensor
Test
button
Sleep timer
Range
Filter
Mounting
base
Sunshield
Model number
RA
-
4961
-
DSQ
Frequency
914.8MHz
Transmission range*
Up to 1
000ft (305m)
Channels
1
Po er supply
4x AA
Batteries
(Not included)
Current
dra
Standby
70µA
Max
18mA
Estimated battery life
300 days (3 triggers/day)
Lo battery indicator
Zone LED on receiver blinks continuously
PIR sensor range
13' (4m) / 23' (7m) / 26' (8m) / 39'
(12m)
PIR sensor
detection
angle
1
2
º
(with
lens
cover)
/
15º
(without cover)
IP rating
IP45
Operating temperature
-
4º~140º F (
-
20º~60º C)
Dimensions
3
7
/
8
"x3
13
/
16
"x4
3
/
4
" (98
x97x120 mm)
4x
Screw anchors
1x Manual
Side Back (Cover removed) Front
*Transmission range will vary depending on installation and operating environment.
Lens Cover
(Removable)
3
13
/
16
"
(97mm)
3
7
/
8
"
(98mm)
2
3
/
4
"
(70mm)
4
3
/
4
"
(120mm)

CBA Wireless Outdoor PIR Sensor
SECO-LARM U.S.A., Inc. 3
Installation:
1.
Select the location where the sensor will be mounted.
2. The sensor should be mounted 6~9 feet (2~3 meter) above ground have
a clear view of the desired detection area and be safe from water.
3. Use the four included mounting screws to mount the sensor to the surface.
4. Point the sensor toward the desired detection area (lens cover can be
removed to widen the detection angle).
6~9'
(2~3m)
Programming the Sensor:
1.
To access programming functions the cover of the se
nsor
must be removed.
2. Remove the sunshield from the sensor.
3. Using a screwdriver remove the screws from the front of
the sensor and remove the cover.
Removing the Cover
Range
Pairing the Sensor:
Test
button
1.
Follow
the
pairing
instructions for the
RA-4961-K1Q receiver or RA-4961-VPQ wireless receiver to
enter pairing mode. (Refer to the RA-4961-K1Q or
RA-4961-VPQ manual for detailed pairing instructions).
2. Press the "Test" button. This will activate the sensor for pairing.
3. The receiver will beep once and cycle to the next channel to confirm successful pairing.
1.
Use the DIP Switches to program various functions.
2. Refer to the guide below for DIP switch programming.
Programming the DIP Switches
Photo
Sensor
Sleep timer
Filter
*Default Setting
3~6
ft
/
s
*
(1~2
m
/
s
)
1.5~3
ft
/
s
(0.5~1
m
/
s
)
c.
Filter
–
The detection speed of the sensor can be set for varying object speeds.
ON* OFF
d.
Photo Sensor
–
When ON the sensor will be inactive during the day or when
near a bright light source.
Range
7s*
30s
a.
Sleep Timer
–
The sensor will not reactivate for the
set amount of time after the sensor is triggered.
13' (4m) 23' (7m)
39' (12m)* 26' (8m)
b.
Range
–
The range of the sensor can be set for
varying
installation environments.

CBA Wireless Outdoor PIR Sensor
4SECO-LARM U.S.A., Inc.
Installing Batteries:
Also Available from SECO
-
LARM:
1.
Remove the sunshield from the sensor.
2.
Using a screwdriver remove the screws from the front
of the sensor and remove the cover.
3. Place 4x AA batteries (not included) in the battery
compartment making sure to observe correct polarity.
4. Replace the cover and screws.
5. Replace the sunshield.
Battery
compartment
Wireless
Alert System
RA-4961-K1Q
Wireless
Magnetic Contact
RA-4961-MCQ
Wireless
Indoor PIR Sensor
RA-4961-PRQ
Wireless
Mailbox/Tilt Sensor
RA-4961-MBQ
Wireless
Vibrating Receiver
RA-4961-VPQ
Wireless
Pushbutton
RA-4961-PBQ
Note: Low battery is indicated on the receiver. Refer to the RA-4961-K1Q or RA-4961-VPQ for more information.
FCC COMPLIANCE STA
TEMENT:
FCC ID: YAHDWS
-
100
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT
ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Notice: The changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment. IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements
no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device
exceeding the RF exposure requirements and void user’s authority to operate the device.
NOTICE
:
The information and specifications printed in this manual are current at the time of publication.
However the
SECO-LARM policy is one of continual development and improvement. For this reason SECO-
LARM reserves the right to
change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Trademarks
are the property of SECO-LARM USA Inc. or their respective owners.
Copyright © 2015 SECO-LARM U.S.A. Inc. All rights reserved. This material may not b
e reproduced or copied in whole or
in part without the written permission of SECO-LARM.
LIMITED
WARRANTY:
This SECO-
LARM product is warranted against defects in material and workmanship while
used in normal service for one (1) year from the date of sale to the original customer. SECO-
LARM’s obligation is limited to
the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO-LARM.
This Warranty
is void if damage is caused by or attributed to acts of God physi
cal or electrical misuse or abuse neglect repair or
alteration improper or abnormal usage or faulty installation or if for any other reason SECO-
LARM determines that such
equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole
obligation of SECO
-
LARM and the purchaser’s exclusive remedy shall be limited to the replacement or repair only at
SECO-LARM’s option. In no event shall SECO-LARM be liable for any special collateral incidental or co
nsequential
personal or property damage of any kind to the purchaser or anyone else.
SECO
-
LARM
®
U.S.A., Inc.
16842 Millikan Avenue Irvine CA 92606 Website: www.seco-larm.com
PIHVK1
Phone: (949) 261-2999 | (800) 662-0800 Email: sales@seco-larm.com
MiRA-4961-DSQ_150916.doc
Table of contents
Other CBA Accessories manuals
Popular Accessories manuals by other brands

S+S Regeltechnik
S+S Regeltechnik PHOTASGARD RHKF Operating Instructions, Mounting & Installation

Medisana
Medisana HU A61 instruction manual

Balluff
Balluff BES 516-300-S345-S4-N user guide

For Your Little One
For Your Little One FYLO-15 instruction manual

Leviton
Leviton OSC10-M0W installation instructions

BASETech
BASETech 1890360 operating instructions