CBA RA-4961-PRQ User manual

RA-4961-PRQ
Wireless Indoor PIR Sensor
Manual
®
•
For use with RA-4961 series receivers
•Wirelessly monitor entryways, rooms, or
other areas
•p to 1,000ft (305m) transmission range*
•
Programmable activation time
•Runs on batteries for a convenient,
wireless installation
•Adjustable mounting angle
*Transmission range will vary depending on installation and operating environment

CBA Wireless Indoor PIR Sensor
2SECO-LARM U.S.A., Inc.
Specifications:
Overview:
Model num er
RA
-
4961
-
PR
Q
Frequency
914.8MHz
Transmission range*
p to 1,000ft (305m)
Channels
1
Power supply
1x 9VDC Battery
(Not included)
Current
draw
Stand y
7
µ
A
Max
18m
A
Estimated attery life
300 days (3 triggers/day)
Low attery indicator
Zone LED on rec
eiver blinks continuously
PIR sensor range
26' (8m)
PIR sensor detection angle
80
º
h
orizontal
Operating temperature
-
4º~140º F (
-
20º~60º C)
Dimensions
2
7
/
16
"x1
15
/
16
"
x
3
9
/
16
" (62x49x90
mm)
Front
Front (Cover removed)
Side
Sensor
LED
Mounting
bracket
Sensor
9V Battery
connector
LED
ON/OFF
Switch
Parts List:
1x
Wireless indoor PIR sensor
2
x Screw
s
Dimensions:
2x Screw anchors
1x Manual
*Transmission range will vary depending on installation and operating environment.
1x Sensor Bracket
2"
(51mm)
2
7
/
16
"
(62mm)
3
9
/
16
"
(90mm)
1
15
/
16
"
(49mm)

CBA Wireless Indoor PIR sensor
SECO-LARM U.S.A., Inc. 3
Installation:
1.
Select the location where the sensor will be mounted.
2. The sensor should be mounted 6~9ft (2~3m) above the ground, have a
clear view of the desired detection area, and be safe from water.
3. se the two included mounting screws to mount the sensor bracket to
the surface.
4. Slide the sensor down onto the bracket.
5. Point the sensor toward the desired detection area.
1.
To acc
ess the timer programming and install/change
the battery,
the cover of the sensor
must be removed.
Note: Remove the sensor from the bracket before removing the cover.
2. Push down behind the tab on the top of the sensor and carefully pull the cover away from
the sensor body.
Removing the Cover
Programming the Sensor:
1.
Follow the pairing instructions for the
RA
-
4961
-
K1Q receiver or RA
-
4961
-
VPQ wireless
receiver to enter the pairing mode. (Refer to the RA-4961-K1Q or RA-4961-VPQ manual for
detailed instructions).
2. Turn the sensor on and wait up to 15 seconds for the PIR to begin sensing.
3. Wave a hand in front of the sensor to activate it for pairing.
4. The receiver will beep once and cycle to the next channel
to confirm successful pairing.
1.
se the DIP Switch to program the sleep timer to 5 seconds
or 5 minutes. The sensor will
not reactivate for the set amount of time after the sensor is triggered.
Programming the Sleep Timer
*Default setting
5 Minutes
5 Seconds*
6~9’
(2~3m)
Pairing the Sensor:

CBA Wireless Indoor PIR Sensor
4SECO-LARM U.S.A., Inc.
FCC COMPLIANCE STATEMENT: FCC ID: YAHHAX-900
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC R LES. OPERATION IS S BJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CA SE HARMF L INTERFERENCE AND (2) THIS DEVICE M ST ACCEPT
ANY INTERFERENCE RECEIVED, INCL DING INTERFERENCE THAT MAY CA SE NDESIRED OPERATION. Notice:
The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority
to operate the equipment. IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change
to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the
RF exposure requirements and void user’s authority to operate the device.
Installing the Battery:
Also Availa le from SECO
-
LARM:
1.
Remove the cover by pushing down
behind
the
tab on the top of the sensor and carefully pulling
the cover away from the sensor body.
2. Connect a 9V battery to the battery connector.
3. Replace the cover.
Wireless
Vi rating Receiver
RA-4961-VPQ
Wireless
Alert System
RA-4961-K1Q
Wireless
Magnetic Contact
RA-4961-MCQ
Wireless
Push utton
RA-4961-PBQ
Wirele
ss
Outdoor PIR Sensor
RA-4961-DSQ
Note: Low battery is indicated on the receiver. Refer to the RA-4961-K1Q or RA-4961-VPQ manual for more information.
9V Battery
Wireless
Mail ox/Tilt Sensor
RA-4961-MBQ
NOTICE
:
The information and specifications printed in this manual are current at the time of publication.
However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-
LARM reserves the right to
change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Trademarks
are the property of SECO-LARM SA Inc. or their respective owners.
Copyright © 2015 SECO-LARM .S.A., Inc. All rights reserved. This material may not be r
eproduced or copied, in whole or
in part, without the written permission of SECO-LARM.
LIMITED
WARRANTY:
This SECO-
LARM product is warranted against defects in material and workmanship while
used in normal service for one (1) year from the date of sale to the original customer. SECO-
LARM’s obligation is limited to
the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty
is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or
alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-
LARM determines that such
equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole
obligation of SECO
-
LARM and the purchaser’s exclus
ive remedy, shall be limited to the replacement or repair only, at
SECO-LARM’s option. In no event shall SECO-
LARM be liable for any special, collateral, incidental, or consequential
personal or property damage of any kind to the purchaser or anyone else.
SECO
-
LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com
PIHVK1
Phone: (949) 261-2999 | (800) 662-0800 Email: sales@seco-larm.com
MiRA-4961-PRQ_150916.doc
Table of contents
Other CBA Accessories manuals
Popular Accessories manuals by other brands

Elkron
Elkron MEDEA installation manual

ENERGY SISTEM
ENERGY SISTEM Extra Battery 2500 quick guide

Owon
Owon 306 quick start guide

Harbor Freight Tools
Harbor Freight Tools ARMSTRONG Owner's manual & safety instructions

Helioscreen
Helioscreen RUBIX installation guide

SICK
SICK GL6L-P1 Series Operating instruction