ccei tild VP User manual

OPERATING INSTRUCTIONS
tild VP
Wifi / Bluetooth connect-
ed electric control box
Réf : PF10Y700 (/701 /702) V02
Table of Contents
1. Technical specifications ................................................................................................................... 2
2. Pack contents ............................................................................................................................... 2
3. Compatible with the Vigipool environment ............................................................................................ 3
3.1. Bluetooth® and Wifi control ................................................................................................... 3
4. Installation and connection ............................................................................................................... 4
4.1. Pump protection .................................................................................................................. 4
4.2. Coupled / uncoupled auxiliary output ......................................................................................... 5
4.3. Pump prohibited / forced operation / T°C / Pool cover .................................................................... 5
5. Choice of the Vigipool "central unit" appliance ....................................................................................... 6
6. “Connection” indicator .................................................................................................................... 7
7. Operating principles ....................................................................................................................... 8
7.1. 3-position switches ............................................................................................................... 8
7.2. Filtering and heat regulation management ................................................................................... 8
7.3. Anti-freeze monitoring .......................................................................................................... 8
7.4. Programming ...................................................................................................................... 8
7.5. Compatible lights ................................................................................................................ 9
8. Application .................................................................................................................................. 9
9. Reset to zero ................................................................................................................................ 9
A. Declaration of conformity ............................................................................................................. 10
Read these instructions carefully before installing, commissioning and using this product.
MPNT0440 v2.0EN (16/01/2023)

OPERATING INSTRUCTIONS tild VP v2.0EN
1. Technical specifications
Dimensions 410 x 310 x 150mm
Electricity supply
230V AC.
PF10Y700: 30mA ground fault circuit breaker to be provided upstream.
PF10Y701 and PF10Y702: ground fault circuit breaker built into the control
box.
Weight 6.5 kg
Protection rating IP-55
Compatible filtering pumps 1.5 HP - Single phase. C16 protection.
Auxiliary output 1.5HP max if booster pump - Single phased. Max 230V. C16 protection
Light output 12V / 100VA. C10 protection
Heat pump output (PF10Y700 / 702 only) 230V. D16 protection for heat pump
Bluetooth® Low Energy (v4.x)
Conforms to the R&TTE Directive 1999/5/EC
Wifi 802.11 b/g/n and "dual band" (2.4 Ghz only)
2. Pack contents
1 control box with tild VP module shipped with cable glands
and grommet.
1 temperature sensor with Ø50mm 1/2" fixing collar
4 fixing screws and anchors (bag)
1 Technical manual (this document) and 1 wiring diagram
2

OPERATING INSTRUCTIONS tild VP v2.0EN
3. Compatible with the Vigipool environment
The tild VP box is compatible with all the devices in the Vigipool environment. The Vigipool environment gathers together
many interconnected water treatment and maintenance appliances that can be controlled by a single application: Vigipool.
The appliances exchange the different measurement data and their actions with each other using a wireless proprietary connec-
tion between the appliances. Different appliances are available (electric filtration box, LED control, pH regulation, connected
pH / ORP analyser, remote touch display, etc.).
3.1. Bluetooth® and Wifi control
The tild VP control box has an embedded Bluetooth® and Wifi transmitter used to control your appliance from a smartphone
or tablet. To be able to control the tild VP, you need an iOs (Apple®) or Android smartphone or tablet running Bluetooth®
Low Energy (v4.x) or Wifi 802.11 b/n/g. Other operating systems (Windows Phone®,...) or devices not running the above-
mentioned pre-requisites are not supported.
For a Wifi connection, the local Wifi details (SSID and password) need to be entered and a Vigipool account created to connect
your tild VP to the Wifi router and control the tild VP using local Wifi and remotely. (see attached specific "Vigipool World"
leaflet)
With Bluetooth, only one telephone / tablet can be connected to the control box at a time. To
connect from another device first disconnect the device which is already connected.
The software embedded in the appliance can be updated automatically. To do this, it must be
connected to WiFi or to another Vigipool appliance that is itself connected to WiFi. If you only
usetheappliancewithBluetooth,youcancreateanaccesspointfromyourphonetotemporarily
connect the appliance and update its software if necessary.
3.1.1. Bluetooth® pairing
On the first connection (using Bluetooth), after having selected your appliance from the list, to pair your smartphone with
the tild VP, approach the smartphone until it is in contact with the appliance, or press button (B) on it when the application
prompts you to do so and indicator (A) flashes blue quickly.
Pairing is only possible via the Vigipool app. Do not attempt pairing from the smartphone's
Bluetooth settings.
3

OPERATING INSTRUCTIONS tild VP v2.0EN
4. Installation and connection
For safety reasons and in compliance with the NF C15-100 standards, the tild VP control box
must be installed
• either at over 3.50 m from the pool edge. This distance takes into account the distance around
obstacles. If the tild VP control box is installed behind a wall, the distance will include the
length of the path taken to move around the wall to reach the box.
• or in an in-ground space in the immediate vicinity of the swimming pool. In this case the
space must be accessible via a hatch which requires a tool to open it.
The control box is shipped without a power supply cable. It must be powered using a 230V
output protected by a 30mA ground fault circuit breaker in compliance with the NF C15-100
standard.
The tild VP control box is installed in several steps.
• Fix the tild VP control box to a wall (4 fixing screws)
• connect the different accessories controlled by the control box inside, as well as the power supply (see wiring diagram)
4.1. Pump protection
The pump is protected by a 16A magnetic-thermal circuit breaker. On your installation, the pump must be protected from short-
circuits and overheating risks (jammed motor shaft, wear, running empty, high surrounding temperature).
To prevent short-circuits, the magnetic-thermal circuit breaker delivered in the control box is perfectly suitable.
To prevent overheating risks, start by checking that the pump is self-protected using a built-in thermal safety device.
If that is not the case, or when in doubt, adapt the magnetic-thermal circuit breaker to the pump power consumption. In that
case you can use:
• A classic motor circuit breaker (with built-in thermal value) calibrated to the pump power
• Or a magnetic-thermal circuit breaker (C or D curve depending on the start-up current value) also calibrated to the rated
pump power.
As an example, for a 0.75 HP pump that consumes 4.5 A WITHOUT BUILT-IN THERMAL SAFETY, a 6 A thermal
protection should be provided.
4

OPERATING INSTRUCTIONS tild VP v2.0EN
4.2. Coupled / uncoupled auxiliary output
The auxiliary output can be coupled to the filtering or not.
In Treatment, Heating or Booster mode, the output is coupled
and users have no operations to carry out: neither in the appli-
cation, nor electrically in the control box.
In Auxiliary mode (connection of exterior lighting or an ap-
pliance not directly linked to the pool for example), users can
configure the auxiliary as UNCOUPLED. In that case the ap-
plication parameters need to be changed as does the control
box (terminals on the right of the contacts, on the lower rail).
For the electric configuration, just switch the coupled bridge
(terminals 2 and 3 - position A on the diagram opposite)
to the uncoupled position (terminals 1 and 2 - position B on
the diagram opposite).
4.3. Pump prohibited / forced operation / T°C / Pool cover
When a level regulation is to be coupled to the tild VP, you can use the Forced operation (MF) and Pump prohibited (IP)
inputs. The MF input will force filtering to start regardless of the scheduled times (for example: to empty a buffer tank when
its level is too high).
The IP input will force filtering to stop during filling or when the level is too low for example. To connect to the 2 IP terminals,
first remove the bridge.
• Forced operation (terminals A and B)
• Pump prohibited (terminals C and D
• Cover (dry contact) (CC terminals)
• Temperature sensor (TT terminals)
5

OPERATING INSTRUCTIONS tild VP v2.0EN
5. Choice of the Vigipool "central unit" appliance
Please refer to the attached "Vigipool World" page for more information
On delivery or after a reset (see "Reset” section),the multi-colour LED (A) flashes slowly white after the initialisation phase.
This corresponds to the choice of the appliance that will perform the Vigipool "central unit" function (see attached specific
"Vigipool World" page):
• If the installation only has this appliance, press the selection button (A). The appliance is then configured as a Vigipool
"central unit" and other appliances can be added to the installation later.
• If the installation has several Vigipool World compatible appliances
– If an appliance is already configured as a Vigipool "central unit", press the button on the Vigipool "central unit" if it has
been powered on for more than one minute. (If it has been powered on for less than a minute, there is no need to press its
button). Your tild VP then connects to the Vigipool "central unit": It stops flashing white and switches to normal operation.
– If no other appliance is already configured as a Vigipool "central unit", turn on all the appliances and press the button on
the appliance you want to use as a Vigipool "central unit". The other products will then connect to the appliance you have
validated as the Vigipool "central unit", they stop flashing white and switch to normal operation mode.
When the tild VP is configured as a Vigipool "central unit", LED (A) lights in green and flashes green when it accepts the
connection of new Vigipool compatible appliances. tild VP accepts new appliances for 5 minutes after it is powered on, or
after its (B) button is pressed.
If you want to change the Vigipool "central unit” appliance, the system must be reset (see "Re-
setting to zero")
6

OPERATING INSTRUCTIONS tild VP v2.0EN
6. “Connection” indicator
The (A) indicator on the front of the module lights in different colours depending on the controller status and may also flash.
Below is a table listing all the statuses:
Flashes slowly white
When the unit is delivered, or after a reset, it flashes white while waiting
for the Vigipool "central unit" to be selected.
See “Choice of the Vigipool "central” unit" section.
Flashes rapidly blue Pairing request from a smartphone (first connection only).
See "Bluetooth® pairing” section.
Steady blue A smartphone is connected to the appliance using Bluetooth®.
Flashes slowly green The tild VP is configured as a Vigipool "central unit" and accepts the con-
nection of new Vigipool compatible appliances (This status is normal dur-
ing the 5 minutes after powering up or after pressing the (B) button.
Steady green
The tild VP is properly connected: If it is configured as a Vigipool "central
unit", it is connected to WiFi. If not, it is connected to the Vigipool "central
unit".
tild VP does not accept the connection of new Vigipool compatible appli-
ances (Normal operating mode).
Flashes blue every two seconds
The tild VP is configured as a Vigipool "central unit", is not configured for
WiFi, and is waiting for a connection from a smartphone via Bluetooth®.
tild VP does not accept the connection of new Vigipool compatible appli-
ances (Normal operating mode).
Flashes rapidly red/green
tild VP is not connected. If it is configured as a Vigipool "central unit", it
is not connected to WiFi (incorrect password or network out of range). If
it is configured to connect to another Vigipool "central unit" appliance, it
cannot connect to that appliance.
Important: the blue LED is less visible in bright light.
7

OPERATING INSTRUCTIONS tild VP v2.0EN
7. Operating principles
7.1. 3-position switches
On the side of the tild VP control box, there are 3-position switches. For each function (filtration, auxiliary, lighting), these
are used to select automatic or manual operation:
• On the "tild" position: Automatic: The function is controlled by the tild module,
• In the middle position "Off / 0": the function in question is off,
• On the "Manu" position: Forced operation (permanent activation) of the function in question.
To be able to control the functions using the application and its programming, set the switches
to the "tild" position.
7.2. Filtering and heat regulation management
The tild VP control box can be used to manage your pool filtering pump depending on the water temperature.
The filtration can be operated manually, programmed, or the appliance can be left to calculate the ideal filtration time every
day. In heat-regulated mode, the appliance will use the entered programmed time slots and adapt each one proportionally to the
temperature. The higher the temperature, the more the time increases and vice versa.
In other words, in “Programmed” mode, you define your filtering times as if the water were at 25°C. At that temperature, the
filtering should usually run for 11 to 13h (possibly spread over several running periods). Next, when heat regulation mode is
activated, the tild VP automatically adjusts the filtering to the water temperature.
If you find that the calculated filtration time is too low, increase the base programming. On the other hand, if you find that the
calculated filtration time is too long, reduce the base programming.
Be careful when switching to heat regulated mode. Incorrect settings (too short base filtering
time slots for example) could lead to insufficient filtering during the season. We recommend
you ask a professional for advice.
7.3. Anti-freeze monitoring
The tild VP control box has a built-in anti-freeze system which needs to be enabled and configured. Its threshold can be set
between 0 and +2°C.
• Below this threshold (If T° < Freezing T°), filtering will be regularly started (10 minutes every 30 minutes) to prevent the
water from having time to freeze by making it flow.
• This freeze protection mode stops as soon as the pool temperature exceeds the set threshold (as soon as T° > freezing T° + 1).
• If the pool temperature drops below 0°C, the pump runs continuously.
The freezing protection monitoring is not active if the "Filtration" switch is in the "Off / 0" position or if the pump's
circuit breaker is in the bottom position.
Below 12°C, the control box starts pro-active monitoring by running the filtering 30 minutes every 4 hours to renew the water
in the piping.
7.4. Programming
For each of the functions controlled by the tildVP, the application can be used to create two different programmes and to choose
on which day(s) they will be activated. For example, different programming times can be defined for weekends and weekdays.
8

OPERATING INSTRUCTIONS tild VP v2.0EN
7.5. Compatible lights
The tild VP control box can be used to control the lights installed in the pool. There are several operating modes available:
•Micro-cut colours: to control all commercially available multicolour lights. A micro-cut is used to switch from one colour
to the next colour / sequence,
•RC+ colour: is used to control CCEI colour lights: direct colour and sequence selection, brightness and speed management,
•Monochrome: pool light ON/OFF mode,
There are several programming modes available:
• A clock mode: a start time + an end time (two programs available with configurable days),
• A dusk mode: the tild VP turns the lights on automatically at dusk for a defined period.
8. Application
To download the Vigipool application, scan the QR CODE below. You can also search for Vigipool using the App Store and
Play Store search engines:
9. Reset to zero
It may be necessary to reset to initialise the tild VP to the factory settings.
There are two possibilities to do that:
With upstream power cut-off:
1. Switch off the power supply to the appliance and wait about a ten seconds,
2. Press and hold button (B) on the appliance,
3. Turn the power back on while keeping the button pressed,
4. Wait until indicator (A) flashes rapidly red,
5. Release the button. All parameters are reset to factory settings.
Without an upstream power cut-off:
1. Press and hold button (B) on the appliance for about 10 seconds,
2. Wait until indicator (A) flashes rapidly red,
3. Release the button. All parameters are reset to factory settings.
Carryingoutaresetwill erase allparametersinmemory(WiFi configuration, pairingofphones
and other Vigipool World appliances, etc.). The start up procedure must therefore be rerun
after a reset.
9

OPERATING INSTRUCTIONS tild VP v2.0EN
A. Declaration of conformity
Bleu Electrique SAS (FR47403521693) declares that the tild VP product meets the safety and elec-
tromagnetic compatibility requirements of European directives 2014/35/EU and 2014/30/EU.
Emmanuel Baret
Marseille, on 16/01/2023
Distributor's stamp
Date of sale: . . . . . . . . . . . . . . . . . . . . . . . Batch N°: . . . . . . . . . . . . . . . . . . . . . . . . . . .
10
This manual suits for next models
3
Table of contents
Other ccei Control System manuals
Popular Control System manuals by other brands

Pentair
Pentair SCREENLOGIC INTERFACE installation guide

Contro l4
Contro l4 Control4 Smart Home quick start guide

Laguna Tools
Laguna Tools SmartShop Maker owner's manual

Joyonway
Joyonway PB554 Simplified operation instruction

Rockford Fosgate
Rockford Fosgate SSC-1500 GEN II installation manual

CommScope
CommScope Teletilt ATC200-LITE-USB Setup