Ceriotti Imperial G57103 User manual

ISTRUZIONIDI MONTAGGIO- USO E MANUTENZIONEASSEMBLY INSTRUCTIONS - USEGE CONDITION
GB
VERSIONI:
VERSIONS:
ART.:G57103
ART.:G57103A
alzagambe elettrico
electric footrest
ART.:G57103V
Vibro + alzagambe elettrico
Vibro + electric footrest
Imperial

ATTREZZATURA NECESSARIA:
NEEDED TOOLS:
ART. : G57103/A/V Imperial CONSEGNA - DELIVERY
pag.01
mm 6
mm 8
CONDIZIONI GENERALI - GENERAL CONDITIONS

FISSAGGIO A PAVIMENTO
FLOOR FIXING
pag.02
4X
ARTT.: G57103-A\V Imperial POSIZIONAMENTO - PLACING
8X
FISSAGGIO ANTERIORE CON SILICONE
VEDI PAG.7 N.5
FRONT FIXING WITH SILICON
SEE PAG.7 N.5
PUNTI DI FISSAGGIO POSTERIORI
VEDI PAG.6 N.3
BACK FIXING POINTS
SEE PAG.6 N.3
PUNTI DI FISSAGGIO ANTERIORI
VEDI PAG.6 N.4
FRONT FIXING POINTS
SEE PAG.6 N.4
PUNTI DI FISSAGGIO POSTERIORI
VEDI PAG.6 N.4
BACK FIXING POINTS
SEE PAG.6 N.4
ART. : G57103
FIX AT THE FLOOR THE BODY OF THE
WASHING SECURELY USING THE DOWELS
OR OTHER FIXING SYSTEMS SUITABLE TO
THE EXISTING PAVEMENT
FISSARE A PAVIMENTO LA SCOCCA DEL
LAVAGGIO IN MODO SICURO UTILIZZANDO
TASSELLI O ALTRI SISTEMI DI FISSAGGIO
ADATTI ALLA PAVIMENTAZIONE ESISTENTE.
ART. : G57103\A
ART. : G57103\V

ARTT.: DIMENSIONI - DIMENSIONS
pag.03
QUOTE ESPRESSE IN MILLIMETRI - SHARES IN MILLIMETERS
970
600.0*
DISTANZA MINIMA CONSIGLIATA
MINIMUM DISTANCE SUGGESTED
*
780
PARETEO ARREDO - WALL ORFORNITURE
PARETEO ARREDO- WALLOR FORNITURE
500*
1240.0
1240.0
1800.0
560
520
G57103-A\V Imperial
780

ACQUA FREDDA
COLD WATER
SCARICO
DRAIN
ACQUA CALDA
WARM WATER
ALLACCIAMENTO
ELETTRICO
ELECTRICAL
CONNECTION
AREA UTILE PER
L’ALLACCIAMENTO IDRICO
AREA PROFIT FOR
HYDRAULIC CONNECTION
DISTANZA MINIMA CONSIGLIATA
MINIMUM DISTANCE SUGGESTED
*
200
930 590*
600*
780
ARTT.: POSIZIONAMENTO - PLACING
ATTENZIONE!
L’ALLACCIAMENTO ALL’IMPIANTO
ELETTRICO ED IDRICO, DEVE
ESSERE ESEGUITO DA
PERSONALE QUALIFICATO
ED AUTORIZZATO NEL RISPETTO
DELLA NORMATIVA VIGENTE.
ATTENTION!
THE ELECTRICAL AND
HYDRAULIC CONNECTION
MUST BE CARRIED OUT BY
QUALIFIED AND AUTHORIZED
STAFF IN COMPLIANCE WITH
THE LAW.
150
1910
*
920
780
570X730 mm (ART. G57103)
570x350 mm (ART. G57103\A \V)
ART. G57103\A \V
ART. G57103
G57103-A\V Imperial pag.04

1
mm 6
4X
pag.05
INSTALLAZIONE E MONTAGGIO INSTALLATION & ASSEMBLY
INSERIRE LA
CERAMICA NELLA SUA
SEDE E FISSARLA CON
LE 4 VITI IN DOTAZIONE.
INSERT
CERAMICS IN HIS
PLACE AND FIX IT
WITH 4 SCREWS
PROVIDED.
ART. : G57103-A\V Imperial

4X
N.4 PUNTI DI FISSAGGIO
N.4 FIXING POINTS
4
3
ACQUA FREDDA
COLD WATER
ACQUA CALDA
WARM WATER
SCARICO
DRAIN
pag.06
SOLO PER ART. : G57103\A \V
ONLY FOR ART. : G57103\A \V
4X
N.4 PUNTI DI
FISSAGGIO
N.4 FIXING POINTS
FIX AT THE FLOOR
WITH 4 ANCHORS
AS SHOWN
AND MAKE THE
HYDRAULIC
CONNECTION.
FISSARE A PAVIMENTO
CON 4 TASSELLI
COME INDICATO
ED EFFETTUARE
L’ALLACCIAMENTO
IDRAULICO
APRIRE COMPLETAMENTE IL
POGGIAGAMBE DOPO AVER
EFFETTUATO L’ALLACCI-
AMENTO ELETTRICO E
FISSARE A PAVIMENTO LA
SCOCCA DELLA POLTRONA
CON 4 TASSELLI COME
INDICATO A DISEGNO.
COMPLETELY OPEN THE
LEGREST AFTER DO
ELECTRICAL CONNECTION
AND FIX TO THE FLOOR
THE SHELL OF ARMCHAIR
WITH 4 DOWELS AS
INDICATED ON DRAWING.
ART. : G57103-A\V Imperial

pag.07
SOLO PER ART.: G57103
ONLY FOR ART.: G57103 5
6
mm 8
PER FISSARE A PAVIMENTO
LA SCOCCA DELLA POLTRO-
NA, APPLICARE DEL SILICO-
NE TRA LA PIASTRA PRE-
SENTE ALLA BASE DELLA
SCOCCA E IL PAVIMENTO
STESSO.
TO FIX ON FLOOR THE BODY
OF THE ARMCHAIR, APPLY
SILICON BETWEEN THE PLATE
AT THIS BASE AND TO THE
FLOOR TOO.
REGISTRARE L’OSCILLANTE RUOTANDO IN SENSO ORARIO PER
STRINGERE E ANTIORARIO PER SMOLLARE A SECONDA DELLE
VOSTRE ESIGENZE.
ATTENZIONE: L’OSCILLANTE NON NECESSITA DI NESSUNA LUBRIFICAZIONE.
RECORDER THE TILT ROTATING CLOCKWISE FOR TIHTEN OR ANTICLOCKWISE
FOR SLACKEN TO SECOND YOUR REQUIREMENTS.
ATTENTION: THE TILT DOES NOT NEED OF ANYKIND OF LUBRIFICATION
ART.: G57103-A\V Imperial

pag.08
SOLO PER ART.: G57103\A
ONLY FOR ART.: G57103\A 7
8
PER ALZARE L’APPOGGIAGA-
MBE PREMERE IL TASTO N.1,
PER ABBASSARLO PREMERE IL
TASTO N.2
TO LIFT UP THE LEGREST PUSH
THE BUTTON N.1, TO LOWER IT
PUSH THE BUTTON N.2
SOLO PER ART.: G57103\V
ONLY FOR ART.: G57103\V
1 (ALTO)
2 (BASSO)
ART.: G57103 \A\V Imperial
ATTIVAZIONE/DISATTIVAZIONE
MASSAGGIO SEDUTA-POGGIAGAMBE
ACTIVATION / DEACTIVATION
SEAT MASSAGE-LEGREST
ATTIVAZIONE / DISATTIVAZIONE
ZONE MASSAGGIANTI SULLO SCHIENALE
ACTIVATION / DEACTIVATION
VIBRO ZONES ON THE BACK
REGOLAZIONE INTENSITA’
VIBRAZIONE MASSAGGIANTE
INTENSITY ADJUSTMENT
MASSAGE VIBRATION
REGOLAZIONE RITMO
CAMBIO ZONA
( SOLO IN PROGRAMMA omp)
RHYTHM REGULATION
ZONE CHANGE
(Only OMP program)
OMP
ATTIVAZIONE PROGRAMMI MASSAGGIANTI:
PREMUTO UNA VOLTA --> PROGRAMMA 1
PREMUTO DUE VOLTE --> PROGRAMMA 2
ACTIVATION MASSAGE PROGRAMS:
PRESSED ONCE -> PROGRAM 1
PRESSED TWICE -> PROGRAM 2
SALITA DISCESA POGGIAGAMBE
UP - DOWN LEGREST
OMP
STOP
STOP
STOP VIBRAZIONE
STOP VIBRATION
1-4
5
intensity
-+
rhythm
-+
1-4
5

pag.09
USO E MANUTENZIONE OPERATING INSTRUCTIONS
NO!
NO!
NON UTILIZZARE DETERGENTI
AGGRESSIVI ED EVITARE L’USO
DEL PHON IN PROSSIMITÁ DEL
RIVESTIMENTO.
DO NOT USE AGGRESSIVE
CLEANERS AND AVOID THE USE
OF THE DRYER IN PROXIMITY
OF THE COATING.
EVITARE LA VICINANZA CON
FORTI FONTI DI CALORE E LA
LUCE DIRETTA DEL SOLE.
AVOID THE PROXIMITY WITH
STRONG HEAT AND DIRECT
SUNLIGHT.
NEL CASO DI MACCHIE SUL
RIVESTIMENTO ASPORTARLE AL
PIù PRESTO CON ACQUA O UN
PRODOTTO IDONEO.
IN THE CASE OF STAINS ON
COATING REMOVE THEM AS
SOON AS POSSIBLE WITH
WATER OR A SUITABLE
PRODUCT.
ART.: G57103 \A\V Imperial

pag.10
GO!
STOP!
APERTURADELL’ACQUA
CHIUSURADELL’ACQUA
DOCCETTA ESTRAIBILE
EXTRACTABLE SHOWER
MONOCOMANDO
MIXER
CHIUSURA
SCARICO
A PRESSIONE
CLOSING
DRAIN
AT PRESSURE
REGOLAZIONE
ACQUA
CALDA-FREDDA
ADJUSTING
THE HOT-COLD
WATER
WATER OPEN WATER CLOSING
ART. : G57103 \A \V Imperial

pag.11
NO!
NO!
SOLO PER ART. G57103\a\v
ONLY FOR ART. G57103\a\v
NO!
NON SEDERSI SULL’APPOGGI-
AGAMBE APERTO
DO NOT SIT ON THE LEGREST
OPENED
NON SEDERSI O APPOGGIARSI
ALLA COLONNA PER NON
DANNEGGAIRE LA SUPERFICIE.
DO NOT SIT OR LEANING TO
THE COLUMN TO AVOID THE
DAMAGING OF THE SURFACE.
SONO VIETATE MODIFICHE O
RIPARAZIONI NON CONTENUTE
NEL PRESENTE MANUALE.
CHANGES AND REPAIRS ARE
PROHIBITED IF NOT CONTAINED
IN THIS MANUAL.
ART. : G57103 \A\V Imperial

pag.12
ART. : G57103 \A \V Imperial
NON ORIENTARE IL GETTO
D’ACQUA SULL’INNESTO DELLA
DOCCETTA.
DO NOT DIRECT THE JET OF
WATER ON THE GRAFT OF THE
SHOWER.
TOGLIERE IL TAPPO NEL CASO
DI NON UTILIZZO PROLUNGATO.
REMOVE THE CAP WHEN NOT
USING FOR PROLONGED TIME.
NON COPRIRE IL LAVELLO CON
PANNI O ALTRO
DON’T COVER THE WASHING
BASIN WITH CLOTHS OR OTHER
IN CASO DI PERDITE IRREGO-
LARI CHIAMARE L’ASSISTENZA.
IN CASE OF IRREGULARS
LOSSES CALL THE SERVICE.

pag.13
ART. : G57103 \A\V Imperial
Note:

pag.14
NO!
IDROCARBURI
CERA SOLVENTI SGRASSANTI
PAGLIETTA
NON UTILIZZARE PRODOTTI
DETERGENTI TROPPO AGGRE-
SIVI O ABRASIVI CHE POTREB-
BERO DANNEGGIARE IL
RIVESTIMENTO!
DO NOT USE TOO AGGRESSIVE
OR ABRASIVE CLEANING
PRODUCTS THAT COULD
DAMAGE THE COATING!
ATTENZIONE !
La ditta non risponde dei danni causati da un montaggio erroneo o
non corretto, eseguito da terzi
ATTENTION !
The company does not answre of the damages caused from an
erroneous or not corrected assembly, executed from thirds party
ART. : G57103 \A\V Imperial

This manual suits for next models
2
Table of contents
Other Ceriotti Personal Care Product manuals
Popular Personal Care Product manuals by other brands

Bauerfeind
Bauerfeind SacroLoc Instructions for use

Amika
Amika Polished Perfection Straightening Brush 2.0 quick start guide

Beurer
Beurer BS 89 Instructions for use

Wanasleep
Wanasleep Wanabesafe WHITE 2020 Manual instructions

Orliman
Orliman BE-300 Use and maintenance instructions

BeautyRelax
BeautyRelax Diamond microdermabrasion Peelmax Professional... user manual