Programming Overview
There are two programming commands used with the DSK Keypad.
*3 is the Programming System Setup. This programming command allows the
programming of the Master Code, setting the main relay opening time, allows latching
(toggling) of the main relay, etc.
*1 is the Programming Command for programming user codes (page #). When
programming the user codes, you have the ability to assign users authorizations. You can
authorize a user to latch (if the system was set up to latch in the *3 programming
sequence), you can allow a user to program or delete codes or activate one of the other
outputs, etc.
The DSK Keypad is configured at the factory. Under normal installation, there is no need
to configure or reset the keypad unless the beeper needs to be quieter.
The Default Master Code is: 1 2 3
The Relay on Time is: 5 sec
Configuration
Input Requirements
The DSK keypad accepts 5VDC or 12-24VDC. System current draw (max) is as follows:
- Standby: 25mA
- During Operation: 100mA
Output Capabilities:
Main Door Output
SPDT relay rated at 24V 2A Max
Output A
A transistor output intended to drive a relay that can be programmed for one of the following:
1. CCTV or Light Controller - First key press triggers a Timed Output (1 to 99 seconds)
2. Auxiliary Output - Manual Control or Timed Output (1 to 99 seconds)
3. Second Door - Users can be assigned to open a 2nd door
4. Doorbell - Press # at the Keypad to trigger a 1 second output for a doorbell (not included)
Output B
A transistor output intended to drive a relay that can be programmed for one of the following:
1. CCTV or Light Controller - First key press triggers a Timed Output (1 to 99 seconds)
2. Auxiliary Output - Manual Control or Timed Output (1 to 99 seconds)
3. Third Door - Users can be assigned to open a 3rd door
4. Internal Alarm System - Detect Break-in, Door-ajar & Tamper
5. Doorbell - Press # at the Keypad to trigger a 1 second output for a doorbell (not included)
Programming System Setup - Continued
- Changing the Master Code (Default 1-2-3)
A. Enter 1 #
B. Enter the New Master Code followed by #
C. Return to Step 3 or enter * * to exit programming
Keypad Status After Step Completion
Step Beep Red LED Green LED
A Double Fast Flash Slow Flash
B Triple Fast Flash Solid
Note: If you forget the Master Code, momentarily ground the ORANGE wire. This will take
you to Step 3 of Programming System Setup. Once you enter setup mode, you have 30
seconds to begin the program sequence.
- Setting the Main Door Open Time (Default: 5 Seconds)
A. Enter 2 #
B. Enter the desired Door Open Time (1-99 Seconds), followed by #
Example: 2 # 1 5 # (15 Sec. Door Open Time)
C. Return to Step 3 or enter * * to exit programming.
Keypad Status After Step Completion
Step Beep Red LED Green LED
A Double Fast Flash Slow Flash
B Triple Fast Flash Solid
- Setting Latching Option (Default: Off)
A. Enter 3 #
B. Select the desired latching option:
Off- 0 #
Manual- 9 9 #
Timed- Enter the desired time interval in hours (1-98), followed by #
Example: 3 # 8 # (Sets timed latching for 8 hours)
C. Return to Step 3 or enter * * to exit programming.
Step Beep Red LED Green LED
A Double Fast Flash Slow Flash
B Triple Fast Flash Solid
- Configuring Output A (Default: Aux #1)
A. Enter 4 #
B. Select one of the following:
- CCTV / External Light
1) Enter 1 #
2) Enter the desired On Time (1-99 seconds), followed by #
Example: 4 # 1 # 1 5 #
(Sets CCTV/Light Option for 15 Seconds)
- Auxiliary Device Number 1
1) Enter 2 #
2) Enter the momentary output time (1-99 seconds), followed by #; -or- Enter 0 to set
the auxiliary device for Manual Operation (ON/OFF), followed by #
Example: 4 # 2 # 0 #
(Sets Auxiliary Device with Manual Operation)
9