Page 2 of 20 Intimidator™ Spot LED 150 User Manual (Rev. 01g)
TABLE OF CONTENTS
1. Before you Begin............................................................................. 3
What is Included............................................................................................3
Unpacking Instructions..................................................................................3
Text Conventions..........................................................................................3
Icons..............................................................................................................3
Safety Notes..................................................................................................4
2. Introduction...................................................................................... 5
Product Overview..........................................................................................5
Product Dimensions......................................................................................6
3. Setup................................................................................................. 7
AC Power......................................................................................................7
Mounting .......................................................................................................8
4. Operation.......................................................................................... 9
Control Panel Operation................................................................................9
Menu Map.....................................................................................................9
Menu Map (hidden).....................................................................................10
Configuration (DMX) ...................................................................................11
Configuration (Standalone Modes).............................................................11
DMX Channel Assignments and Values.....................................................13
5. Technical Information.................................................................... 15
General Maintenance..................................................................................15
General Troubleshooting ............................................................................16
Returns Procedure......................................................................................17
Claims .........................................................................................................17
Contact Information.....................................................................................17
DMX Primer.................................................................................................18
6. Technical Specifications............................................................... 20
Document Information
The information and specifications contained in this document are subject to change without
notice. CHAUVET® assumes no responsibility or liability for any errors or omissions that may
appear in this manual.
© Copyright 2011 CHAUVET®. All rights reserved
Printed in P.R.C.
Electronically published by CHAUVET® in the United States of America
Author Editor
A. Chiappone R. Jones

Intimidator™ Spot LED 150 User Manual (Rev. 01g) Page 3 of 20
1.
B
EFORE YOU
B
EGIN
What is Included
1 x Intimidator™ Spot LED 150
1 x Mounting bracket
2 x mounting bolts
1 x safety eyebolt
1 x Power Cord
1 x Warranty Card
1 x User Manual
Unpacking Instructions
Immediately upon receiving this product, carefully unpack it and check the container in
which you received it. Make sure that you have received all the parts indicated above
and that they are all in good condition. If the material inside the container (this product
and any other accessory included with it) appears damaged from shipping, or if the
container shows signs of mishandling, notify the shipper immediately. In addition,
retain the container and all the packing material for inspection.
See the Claims section in the “Technical Information” chapter.
Text Conventions
Convention Meaning
<Menu> A key to be pressed on the fixture’s control panel
1~512 A range of values
50/60 A set of values of which only one can be chosen
Settings A menu option not to be modified (for example, showing the operating
mode/current status)
Menu > Settings A sequence of menu options to be followed
ON A value to be entered or selected
Icons
Icon Meaning
This paragraph contains critical installation, configuration, or operation
information. Failure to comply with this information may render the
fixture partially or completely inoperative, cause damage to the fixture,
or cause harm to the user.
This paragraph contains important installation or configuration
information. Failure to comply with this information may prevent the
fixture from functioning correctly.
This paragraph reminds you of useful, although not critical, information.
Product at a Glance
Internal dimmer
Auto Programs
Outdoor Use
Auto-ranging Power Supply
Sound Activated
Replaceable Fuse
DMX
User Serviceable
Master/Slave
Duty Cycle

Page 4 of 20 Intimidator™ Spot LED 150 User Manual (Rev. 01g)
Safety Notes
Please read the following notes carefully because they include important safety
information about the installation, usage, and maintenance of this product.
Keep this User Manual for future consultation. If you sell this product to another
user, be sure that they also receive this document.
Always make sure that the voltage of the outlet to which you are connecting this
product is within the range stated on the decal or rear panel of the fixture.
This product is for indoor use only! To prevent risk of fire or shock, do not expose
this fixture to rain or moisture.
This product is for indoor use. Do not submerge this product.
Make sure there are no flammable materials close to the unit while operating.
Always install this product in a location with adequate ventilation, at least 20 in (50
cm) from adjacent surfaces.
Be sure that no ventilation slots on the unit’s housing are blocked.
Always disconnect this product from the power source before cleaning it or
replacing the fuse.
Make sure to replace the fuse with another of the same type and rating.
If mounting this product overhead, always secure it to a fastening device using a
safety cable.
The maximum ambient temperature (Ta) is 104° F (40° C). Do not operate this
product at higher temperatures.
In the event of a serious operating problem, stop using the unit immediately.
Never try to repair this product. Repairs carried out by unskilled people can lead
to damage or malfunction. Please contact the nearest authorized technical
assistance center.
Never connect this product to a dimmer pack.
Make sure the power cord is not crimped or damaged.
Never disconnect the power cord by pulling or tugging on the cord.
Never carry a fixture from the power cord or any moving part. Always use the
hanging/mounting bracket or the handles.
Always avoid direct eye exposure to the light source when this fixture is on.

Intimidator™ Spot LED 150 User Manual (Rev. 01g) Page 5 of 20
2.
I
NTRODUCTION
Product Overview
DMX in
DMX outPower in
Power out
Fuseholde
r

Page 6 of 20 Intimidator™ Spot LED 150 User Manual (Rev. 01g)
Product Dimensions

Intimidator™ Spot LED 150 User Manual (Rev. 01g) Page 7 of 20
3.
S
ETUP
AC Power
This product has an auto-ranging power supply and it can work with an input voltage
range of 100~240 VAC, 50/60 Hz.
To determine the power requirements for a particular fixture, see the label affixed to
the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s
listed current rating indicates its average current draw under normal conditions.
Always connect this product to a protected circuit (circuit breaker or fuse),
making sure that it has an appropriate electrical ground to avoid the risk of
electrocution or fire.
Never connect this product to a rheostat (variable resistor) or dimmer circuit,
even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Power Linking
This fixture provides power linking via the Edison outlet located in the back of the unit.
Please see the diagram below for further explanation.
PowerLinking
Diagram
You can power link up to 11 Intimidator™ Spot LED 150 units on 120 VAC or up
to 20 Intimidator™ Spot LED 150 units on 230 VAC.
The power linking diagram shown above corresponds to the North American
version of this product ONLY! If using this product in other markets, you must
consult with the local CHAUVET® distributor as power linking connectors and
requirements may differ in your country or region.
GenericFixtureHousing
1
st
Fixture 2
nd
Fixture3
r
d
Fixture
Otherfixtures

Page 8 of 20 Intimidator™ Spot LED 150 User Manual (Rev. 01g)
Mounting
Orientation
The Intimidator™ Spot LED 150 may be mounted in any position, provided there is
adequate room for ventilation around it.
Rigging
Be sure that the structure onto which you are mounting this product can support its
weight. Please see the “Technical Specifications” section of this manual for weight
information.
Make sure to mount the fixture securely to a rigging point, whether an elevated
platform or a truss.
When rigging this product onto a truss, you should use a mounting clamp of
appropriate weight capacity. The bracket has a 13 mm hole, which is appropriate for
this purpose.
When mounting this product overhead, always use a safety cable.
Before deciding on a location for this product, always make sure that it will be easy to
access the unit for maintenance and programming purposes.
When power linking multiple fixtures, you must always consider the length of the
power linking cable and mount the fixtures close enough for the cable to reach them.
MountingDiagram
Bracket
attachment
Rubber feet
(
4
)
Safety bolt
attachment
Bottom of fixture

Intimidator™ Spot LED 150 User Manual (Rev. 01g) Page 9 of 20
4.
O
PERATION
Control Panel Operation
To access the control panel functions, use the four buttons located underneath the display.
Button Function
<MODE/ESC> Press to find an operation mode or to
back out of the current menu option
<UP> Press to scroll down the list of options
or to find a higher value
<DOWN> Press to scroll up the list of options or
to find a lower value
<ENTER> Press to activate a menu option or a
selected value
Menu Map
Mode Programming Steps Description
DMX Mode d*** d001~512 Selects the DMX starting address
Operating
Mode
NASL SLoU Automatic slow
NAFA FASt Automatic fast
NStS SrUn Sound-active mode
SLAU SonU Slave mode
Pan Invert Standard pan PAN Reverse the pan direction
Inverted pan rPAN
Tilt Invert Standard tilt tit Reverse the tilt direction
Inverted tilt rtit
Display Invert Standard display dis Use this function for hanging the product
upside down
Inverted display rdis
Personality Advanced 11CH Select the DMX personality
Basic 6CH
Pan Range
Pan 540° PA54
Select the maximum pan range
Pan 360° PA36
Pan 180° PA18
Tilt Range
Tilt 270° ti27
Select the maximum tilt range
Tilt 180° ti18
Tilt 90° ti 9
Reset System reset rESt Reset all motors
Load Factory
Defaults Load default LoAd Use this to revert all settings for the fixture
back to the factory-defaults values

Page 10 of 20 Intimidator™ Spot LED 150 User Manual (Rev. 01g)
Menu Map (hidden)
This fixture has a hidden menu. The purpose of this menu is to adjust the home position
(electronic adjustment) of the attributes listed below.
Mode Programming Steps Description
Pan adjustment P*** P000~255 Adjust the pan home position
Tilt adjustment t*** t000~255 Adjust the tilt home position
Gobo wheel
adjustment G*** G000~255 Adjust the gobo wheel home position
Color wheel
adjustment C*** C000~255 Adjust he color wheel home position
LED dimmer
threshold d*** d000~255 Adjust the LED dimming threshold
(minimum)
Accessing the hidden menu
1) Press and hold <MODE/ESC> for at least 10 seconds.
2) Use <UP> or <DOWN> to input the following access code: 2323.
3) Press <ENTER>.

Intimidator™ Spot LED 150 User Manual (Rev. 01g) Page 11 of 20
Configuration (DMX)
Set this product in DMX mode to control it with a DMX controller.
1) Connect this product to a suitable power outlet.
2) Turn this product on.
3) Connect a DMX cable from the DMX output of the DMX controller to the DMX
input socket of this product.
Starting Address
When selecting a starting DMX address, always consider the number of DMX
channels the selected DMX mode uses. If you choose a starting address that is too
high, you could restrict the access to some of the fixture’s channels.
The Intimidator™ Spot LED 150 uses up to 11 DMX channels in the advanced
personality, which defines the highest configurable address to 502.
If you are not familiar with the DMX protocol, you may refer to the “DMX Primer”
section in the “Technical Information” chapter.
To select the starting address, do the following:
1) Press <MODE/ESC> repeatedly until d*** shows on the display.
2) Press <ENTER>.
3) Use <UP> or <DOWN> to select the starting address.
4) Press <ENTER>.
Configuration (Standalone Modes)
Set this product in one of the standalone modes to control it without a DMX controller.
1) Connect this product to a suitable power outlet.
2) Turn this product on.
Sound Active Mode
To enable the Sound Active mode, do the following:
1) Press <MODE/ESC> repeatedly until one of the following shows on the display:
NASL, NAFA, NStS, SLAU.
2) Use <UP> or <DOWN> to select NStS.
3) Turn the music on.
4) Press <ENTER>.
The fixture will only respond to the low frequencies of the music (bass and
drums).
Automatic Mode
Never connect a fixture that is operating in any standalone mode, whether
Static, Automatic, or Sound to a DMX string connected to a DMX controller.
This is because fixtures in standalone mode may transmit DMX signals that
could interfere with the DMX signals from the controller.
To enable the Automatic Mode, follow the instructions below:
1) Press <MODE/ESC> repeatedly until one of the following shows on the display:
NASL, NAFA, NStS, SLAU.
2) Use <UP> or <DOWN> to select NAFA (fast) or NASL (slow).
4) Press <ENTER>.

Page 12 of 20 Intimidator™ Spot LED 150 User Manual (Rev. 01g)
Master/Slave Mode
This mode allows a single Intimidator™ Spot LED 150 unit (the “master”) to control
the actions of one or more Intimidator™ Spot LED 150 units (the “slaves”) without the
need of a DMX controller. The master unit will be set to operate in either Automatic or
Sound Active mode, while the slave units will be set to operate in Slave Mode. Once
set and connected, the slave units will operate in unison with the master unit.
Configure the units as indicated below.
Slave units:
1) Press <MODE/ESC> repeatedly until one of the following shows on the display:
NASL, NAFA, NStS, SLAU.
2) Press <ENTER> to accept.
3) Set the DMX address to “001”, as previously explained.
5) Connect the DMX input of the first slave unit to the DMX output of the master unit.
6) Connect the DMX input of the subsequent slave units to the DMX output of the
previous slave unit.
7) Finish setting and connecting all the slave units.
Master unit:
1) Set the master unit to operate in either Automatic or Sound mode, as previously
indicated.
2) Make the master unit the first unit in the DMX daisy chain.
Configure all the slave units before connecting the master unit to the DMX
daisy chain.
Never connect a DMX controller to a DMX string configured for Master/Slave
operation because it may interfere with the signals from the master unit.
Do not connect more than 31 slave units to the master unit.

Intimidator™ Spot LED 150 User Manual (Rev. 01g) Page 13 of 20
DMX Channel Assignments and Values
11-CH
Channel Function Value Setting
1 Pan 000 255 0~540°
2 Tilt 000 255 0~270°
3 Pan fine 000 255 0~3°
4 Tilt fine 000 255 0~3°
5 Pan/tilt speed 000 255 Fast~slow
6 Color
000 005
006 011
012 017
018 023
024 029
030 035
036 041
042 047
048 053
054 063
064 069
070 075
076 081
082 087
088 093
094 099
100 105
106 111
112 117
118 127
128 191
192 255
Open (white)
1 (yellow)
2 (magenta)
3 (green)
4 (red)
5 (cyan)
6 (orange)
7 (blue)
8 (light green)
9 (light red)
White/yellow (split colors)
Yellow/magenta (split colors)
Magenta/green (split colors)
Green/red (split colors)
Red/cyan (split colors)
Cyan/orange (split colors)
Orange/blue (split colors)
Blue/light green (split colors)
Light green/light red (split colors)
Light red/white (split colors)
Rotate clockwise (slow~fast)
Rotate counter-clockwise (slow~fast)
7 Shutter
000 003
004 007
008 215
216 255
Blackout
Open
Strobe (0.5~20 Hz)
Open
8 Dimmer 000 255 0~100%
9 Gobo
000 005
006 011
012 017
018 023
024 029
030 035
036 041
042 047
048 053
054 063
064 073
074 079
080 085
086 091
092 097
098 103
104 109
110 115
116 121
122 127
128 191
192 255
Open
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Gobo 8
Gobo 9
Gobo 1 (gobo shake)
Gobo 2 (gobo shake)
Gobo 3 (gobo shake)
Gobo 4 (gobo shake)
Gobo 5 (gobo shake)
Gobo 6 (gobo shake)
Gobo 7 (gobo shake)
Gobo 8 (gobo shake)
Gobo 9 (gobo shake)
Open
Rotate clockwise (slow~fast)
Rotate counter-clockwise (slow~fast)
10 Control
000 007
008 027
028 047
048 067
068 087
088 107
108 127
128 147
148 167
168 187
188 207
208 227
228 247
248 255
No function
Enable pan/tilt move-in-black
Enable gobo move-in-black
Disable pan/tilt/gobo move-in-black
Enable color move-in-black
Disable pan/tilt/color move-in-black
Disable gobo/color move-in-black
Disable pan/tilt/gobo/color move-in-black
Reset pan
Reset tilt
Reset color
Reset gobo
Reset all
No function
11 Pan/tilt Movement macros
000 007
008 023
024 039
040 055
056 071
No function
Automatic movement 1
Automatic movement 2
Automatic movement 3
Automatic movement 4
Continues on the next page

Page 14 of 20 Intimidator™ Spot LED 150 User Manual (Rev. 01g)
Continued from previous page
Channel Function Value Setting
11 Pan/tilt Movement macros
072 087
088 103
104 119
120 135
136 151
152 167
168 183
184 199
200 215
216 231
232 247
248 255
Automatic movement 5
Automatic movement 6
Automatic movement 7
Automatic movement 8
Sound-active movement 1
Sound-active movement 2
Sound-active movement 3
Sound-active movement 4
Sound-active movement 5
Sound-active movement 6
Sound-active movement 7
Sound-active movement 8
6-CH
Channel Function Value Setting
1 Pan 000 255 0~540°
2 Tilt 000 255 0~270°
3 Color
000 005
006 011
012 017
018 023
024 029
030 035
036 041
042 047
048 053
054 063
064 069
070 075
076 081
082 087
088 093
094 099
100 105
106 111
112 117
118 127
128 191
192 255
Open (white)
1 (yellow)
2 (magenta)
3 (green)
4 (red)
5 (cyan)
6 (orange)
7 (blue)
8 (light green)
9 (light red)
White/yellow (split colors)
Yellow/magenta (split colors)
Magenta/green (split colors)
Green/red (split colors)
Red/cyan (split colors)
Cyan/orange (split colors)
Orange/blue (split colors)
Blue/light green (split colors)
Light green/light red (split colors)
Light red/white (split colors)
Rotate clockwise (slow~fast)
Rotate counter-clockwise (slow~fast)
4 Shutter
000 003
004 007
008 215
216 255
Blackout
Open
Strobe (0.5~20 Hz)
Open
5 Dimmer 000 255 0~100%
6 Gobo
000 005
006 011
012 017
018 023
024 029
030 035
036 041
042 047
048 053
054 063
064 073
074 079
080 085
086 091
092 097
098 103
104 109
110 115
116 121
122 127
128 191
192 255
Open
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Gobo 8
Gobo 9
Gobo 1 (gobo shake)
Gobo 2 (gobo shake)
Gobo 3 (gobo shake)
Gobo 4 (gobo shake)
Gobo 5 (gobo shake)
Gobo 6 (gobo shake)
Gobo 7 (gobo shake)
Gobo 8 (gobo shake)
Gobo 9 (gobo shake)
Open
Rotate clockwise (slow~fast)
Rotate counter-clockwise (slow~fast)
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9

Intimidator™ Spot LED 150 User Manual (Rev. 01g) Page 15 of 20
5.
T
ECHNICAL
I
NFORMATION
General Maintenance
Dust build up reduces light output performance and can cause overheating. This can
lead to reduction of the light source’s life and/or mechanical wear. To maintain
optimum performance and minimize wear, you should clean your lighting fixtures at
least twice a month. However, be aware that usage and environmental conditions
could be contributing factors to increase the cleaning frequency.
To clean this fixture, follow the instructions below:
Unplug the fixture from power.
Wait until the fixture is cold.
Use a vacuum (or dry compressed air) and a soft brush to remove dust collected
on the external surface/vents.
Clean all external optics with a mild soap solution, ammonia-free glass cleaner, or
isopropyl alcohol.
Apply the solution directly to a soft, lint free cotton cloth or a lens cleaning tissue.
Softly drag any dirt or grime to the outside of the external optics.
Gently polish the external optics until they are free of haze and lint.
Always dry the external optics carefully after cleaning them.
Do not spin the cooling fans using compressed air because you could damage
them.

Page 16 of 20 Intimidator™ Spot LED 150 User Manual (Rev. 01g)
General Troubleshooting
Symptom Possible Cause Possible Action
Circuit breaker
or fuse keeps
blowing
Excessive load on the circuit Make sure that the total load
does not exceed 80% of the
breaker or fuse nominal current
Short circuit along the power
lines Check the power lines and
power cords
Product does not
power up
No energy on power outlet Check power outlet
Change to another outlet
Loose or damaged power cord Check the power cord
Blown fuse Replace blown fuse with a good
one of the same type and rating
Internal problem Send product for repair
Fixture does not
respond to DMX
Wrong starting address on the
fixture Set the correct starting address
on the fixture
Use the right fader(s) on the
controller
Wrong DMX personality on the
fixture Set the correct DMX fixture’s
personality
Assign the faders accordingly
Wrong operating mode set on
the fixture Change the fixture settings
Loose or damaged DMX cable Check the DMX cable before
the faulty unit
Internal problem Send product for repair
Intermittent DMX
Problems
Signal cables are not DMX
compatible Replace non DMX cables with
true DMX cables
Interference with AC or radio
signals Keep DMX cables away from
AC wires or radio equipment
DMX cable too long Install an optically coupled DMX
amplifier right before the fixture
with intermittent problems
Too many fixtures connected Install an optically coupled DMX
amplifier after unit #32
Terminator not connected Install a terminator, as indicated
in the “DMX Primer” section.
If you still experience problems after trying the above solutions, contact
CHAUVET® Technical Support.

Intimidator™ Spot LED 150 User Manual (Rev. 01g) Page 17 of 20
Returns Procedure
The user must send the merchandise prepaid, in the original box, and with its original
packing and accessories. CHAUVET® will not issue call tags.
Call CHAUVET® and request a Return Merchandise Authorization Number (RMA #)
before shipping the fixture. Be prepared to provide the model number, serial number,
and a brief description of the cause for the return.
The user must clearly label the package with a Return Merchandise Authorization
Number (RMA #). CHAUVET® will refuse any product returned without an RMA #.
DO NOT write the RMA # directly on the box. Instead, write it on a properly
affixed label.
Once you have received the RMA #, please include the following information on a
piece of paper inside the box:
Your name
Your address
Your phone number
The RMA #
A brief description of the problem
Be sure to pack the fixture properly. Any shipping damage resulting from inadequate
packaging will be the customer’s responsibility. As a suggestion, proper UPS packing
or double-boxing is always a safe method to use.
CHAUVET® reserves the right to use its own discretion to repair or replace
returned product(s).
Claims
The carrier is responsible for any damage incurred during shipping to this product or
any part that shipped with it. Therefore, if the received merchandise appears to have
damages caused during shipping, the customer must submit the damage report and
any related claims with the carrier, not CHAUVET®. The customer must submit the
report upon reception of the damaged merchandise. Failure to do so in a timely
manner may invalidate the customer’s claim with the carrier.
For other issues such as missing components or parts, damage not related to
shipping, or concealed damage, the customer must make claims to CHAUVET®
within seven (7) days of receiving the merchandise.
Contact Information
World Headquarters
United Kingdom & Ireland
CHAUVET®
CHAUVET® Europe Ltd.
General Information
Address: 5200 NW 108th Avenue
Sunrise, FL 33351
Voice: (954) 929-1115
Fax: (954) 929-5560
Toll free: (800) 762-1084
Technical Support
Voice: (954) 929-1115 (Press 4)
Fax: (954) 756-8015
Email: [email protected]
General Information
Address: Unit 1C
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK
NG16 6NT
Voice: +44 (0)1773 511115
Fax: +44 (0)1773 511110
Technical Support
Email: uktech@chauvetlighting.com
World Wide Web
World Wide Web
www.chauvetlighting.com
www.chauvetlighting.co.uk

Page 18 of 20 Intimidator™ Spot LED 150 User Manual (Rev. 01g)
DMX Primer
The USITT DMX512-A data transmission protocol (DMX, from now on) is based on
the EIA-485 standard and it has 512 channels (001 to 512). This system requires a
controller (DMX controller), one or more DMX compatible fixtures, and a DMX circuit
(also known as “DMX universe”) to link the fixtures to the controller.
Depending on their complexity and features, DMX compatible fixtures may require
from one to more than 30 DMX channels to operate. Some DMX fixtures have
multiple operation modes (also known as “personalities”), each with its own number
of channels and controllable parameters.
Starting Address
In the DMX system, the controller sends DMX data to each fixture based on the
fixture’s starting address. The starting address is the number of the DMX channel
(001 to 512) assigned to the fixture’s first control channel (Channel 1). When
assigning starting addresses to multiple fixtures, it is critical to ensure that no starting
address is already in use by another fixture to prevent channels from overlapping.
Otherwise, the affected fixtures may operate erratically.
For instance, a user has two DMX compatible fixtures. Fixture “A” has four channels
and fixture “B” has six channels. If the user configures the starting address of fixture
“A” to “001”, channels 001 through 004 on the DMX controller will control fixture “A”.
This means that the user should assign the starting address of fixture “B” to “005” or
higher. For a starting address of “005”, the DMX controller would use channels 005 to
010 to control fixture “B”.
It is possible to control multiple fixtures of the same type by assigning each one of
them the same starting address. In this case, all the fixtures would respond in unison
(synchronized) to the signals from the DMX controller.
Fixture Linking (Daisy Chain)
DMX compatible fixtures receive the control signals
from the DMX controller through the DMX cables.
Each fixture has a DMX In and a DMX Out
connector. The figure to the right illustrates how the
fixtures link to each other using multiple segments of
DMX cable in a sequential format called “daisy
chain”.
The order in which the fixtures connect to the DMX
controller is irrelevant because all fixtures receive
the same DMX signals and they only respond to
them based on their individual starting addresses.
However, it is important to notice that the
connections between fixtures should always be as
short and direct as possible.
To ensure the integrity of the DMX signal, follow the
recommendations of the EIA-485 standard:
The maximum recommended cable length is 500 m (1,640 feet).
The maximum recommended number of fixtures on the same daisy chain is 32.
Connecting more than 32 fixtures on one daisy chain without the use of a DMX
optically-isolated splitter may result in deterioration of the digital DMX signal.
DMX
Controller
1
st
DMX
Fixture
2
nd
DMX
Fixture
Toother
fixtures

Intimidator™ Spot LED 150 User Manual (Rev. 01g) Page 19 of 20
DMX Cabling
The DMX protocol requires using special data cables to accommodate for the high
speed digital signals it uses. Despite their apparent similarities, data cables are
electrically different from standard microphone cables because they can carry high
frequency digital signals and have better protection against electromagnetic
interference. You can purchase CHAUVET® certified DMX cables directly from a
dealer/distributor or make your own DMX cable.
If you choose to make your own DMX cable, you must use a data-grade cable such
as the Belden 9841, which has the following electrical characteristics:
Type: shielded, 2-conductor twisted pair
Maximum capacitance between conductors: 30 pF/ft
Maximum capacitance between conductor and shield: 55 pF/ft
Maximum resistance: 20 ohms/1000 ft
Nominal impedance: 100~140 ohms
DMXConnectors
Each DMX cable must have a male XLR connector on one end and a female XLR
connector on the other end. The DMX protocol indicates that the XLR connectors
must have five pins. However, most lighting fixtures use the 3-pin XLR connector.
The pin assignment of the 3-pin and 5-pin XLR connectors in a DMX cable is as
follows:
Male Plug
Female Plug
Signal 3-Pin
5-Pin
5-Pin
3-Pin Signal
Common 1
1
1
1 Common
Data - 2
2
2
2 Data -
Data + 3
3
3
3 Data +
Not used
4
4
Not used
Not used
5
5
Not used
You can use the above table to create a 3-pin/3-pin cable, a 5-pin/5-pin cable, or a 3-
pin to 5-pin adapter.
The DMX daisy chain uses a terminator to reduce signal transmission problems,
especially with long cables. The terminator consists of either a 3-pin or 5-pin XLR
male plug with a 120 Ω, ¼ W resistor connected to the wire side of pins 2 and 3, as
shown below.
The terminator plug connects to the DMX Out socket of the last DMX fixture in the
daisy chain.
Do not allow the common wire of the DMX cable to touch the fixture’s chassis
ground. This could cause a ground loop, which may affect your fixtures’
performance. Test all DMX cables with an ohmmeter to verify the correct
polarity of the wires, and to make sure that they are not touching the shield or
each other.

Page 20 of 20 Intimidator™ Spot LED 150 User Manual (Rev. 01g)
6.
T
ECHNICAL
S
PECIFICATIONS
Dimensions and Weight
Length Width Height Weight
8.1 in (205 mm) 8.3 in (211 mm) 11.5 in (291 mm) 9.3 lbs (4.2 kg)
Note: Dimensions in inches rounded to the nearest decimal digit.
Power
Power Supply Type Range Voltage Selection
Switching (internal) 100~240 V, 50/60 Hz Auto-ranging
Parameter 120 V, 60 Hz 230 V, 50 Hz (Europe only)
Consumption 54 W (0.7 A) 91 W (0.4 A)
Power I/O Input Output
Connectors IEC Edison
Cord plug Edison N/A
Light Source
Type Power Lifespan
LED 15 W 50,000 hours
Color Quantity LED Drive Current
White 1 3.6 mA
Photo Optic
Parameter Narrow Lenses
Illuminance @ 1 m 14,200 lux
Illuminance @ 2 m 2,714 lux
Beam angle 15º
Thermal
Maximum External Temp. Cooling System
104° F (40° C) Fan cooled
DMX
I/O Connectors Connector Type Channel Range
3-pin XLR Sockets 6, 11
Ordering
Item No. Item Name Item Code
INTIMSPOTLED150 Intimidator™ Spot LED 150 08010176
Other manuals for Intimidator Wash LED 150
7
Table of contents
Other Chauvet Projector manuals

Chauvet
Chauvet Q-SPOT 260 LED User manual

Chauvet
Chauvet LRG-55 User manual

Chauvet
Chauvet LG-3355 User manual

Chauvet
Chauvet Maverick Force 1 Spot User manual

Chauvet
Chauvet Gobo Shot 50W IRC User manual

Chauvet
Chauvet Gobo Shot 50W IRC User manual

Chauvet
Chauvet LFS-75DMX User manual

Chauvet
Chauvet SX GOBO DMX512 User manual

Chauvet
Chauvet SX Gobo User manual

Chauvet
Chauvet COLORado Batten Q15 User manual