manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Chemical Concepts
  6. •
  7. Cleaning Equipment
  8. •
  9. Chemical Concepts SG-5500 User manual

Chemical Concepts SG-5500 User manual

Whats in The Box:
1 - Spot Cleaning Gun
1 - Volume Control Spring (EXTRA)
1 - Atomizer Valve
1 - Air Hose
(EXTRA)
SG-5500
www.cci dom. com
TextileCleaning Gun
110V/ 60Hz
S/N: 00001
Chemical Consultants
INCORPORATED
1850 Wild Turkey Circle Corona CA 92880 USA
951/735-5511 FAX 951/735-7999 www.ccidom.com
Chemical Consultants
Model SG-5500
Textile Cleaning Gun
WARNING
110 volt electric gun - DO NOT
use with flammable liquids
SG-5500
www.ccidom.com
Textile Cleaning Gun
110V / 60Hz
S/N: 00001
Operating Instructions
With Built-In Quick Air Dry
Parts In Stock
Special Order
Frame Type
Tip Angle
Tip Type
Weight
Voltage
Hook Assembly
Output
Power Dissipation
Capacity
Nozzle
Solution
Polypropylene Frame
10 Degree Curve
Plate Brass
2.75 Lbs.
110 Volts / 60 Hz
U-hook Assembly
3.7 Oz.. (110 Cc) Per Minute
50 Watts
34 Oz. (1,000 Cc)
.012” (0.3 Mm)
The SG-5500 sprayer works
best at a distance of about
8-12” (20-30 cm) from
sprayer to fabric. To prevent
the fabric from being
damaged during the spraying
of fine
Optimal operating pressure will be between 60-80 psi (4 -5.5 Bar) when using Quick
Air Dry Feature.
Fill spot gun cup with a
non-flammable spot
cleaner chemical.
Plug Gun into
a 110V outlet.
Pull trigger to
dispense liquid.
Point in a safe
direction.
Turning clockwise will
decrease pressure and
the amount of dispensing
liquid.
Adjust Spray tip
2
3
5
1
4
6
MAINTENANCE
CAUTION
***WARNING
TROUBLESHOOTING
OPERATIONSPECIFICATIONS
NOTE: See back for
important Instructions
on how to properly set
up your spot gun.
-
Clockwise creates
high pressure jet
-
Counter clockwise
creates fan/mist
Turning knob counter clockwise
will increase pressure and the
amount of dispensing liquid.
-Turning clockwise will decreasepressure and the amount of dispensing liquid.
-Turning knob counter clockwise will increase pressure and the amount of dispensing liquid.
1 2 3 4 5 6
To find the ideal sweet spot begin by turning the rear knob all the
way clockwise.
Once the knob is all the way clockwise, you are goingto turn the
knob two full turns counter clock wise. You are now in the middle
of the sweet spot (Position 4)
From position 4 you can turn the knob one full turn clock wise or
counter clock wise to change flow characteristics.
2
3
1
1 2 3 4 5 6
When you have finished spraying more than one
week, or before storing the unit empty any
remaining residue out of the container. Pour some
lubricating oil on the suction tube to triggle switch
lubricating cylinder.
This unit releases a high pressure stream of product. Keep tip of gun pointed in safe
direction at all times. Keep hands and arms away from high pressure stream at all
times. Wear eye protection at all times.
DO NOT use this gun with flammable liquids. 110 volt electric motor has potential of
igniting flammable liquids.
The Quick Air Dry feature allows operator to clean and dry soiled areas simultaneously.
* When using Quick Air Dry do not exceed 100 psi (6.8 Bar)
Take off the cylinder and nozzle and use
a .125” (3.5 mm) round stick to knock
this side of nozzle to release the piston.
Then clean and lubricate the piston.
Take off nozzle and use blower to
discharge impurities.
1) Check the valve on nozzle.
2) Check if suction is fixed.
3) Check if control knob is adjusted to
right position.
4) Replace cylinder if it is
Motor operating, but no
liquid feeding.
The nozzle split or no
liquid feeding during
spraying.
Motor does not operate,
but humming sound
remains.
Impurities were in the
cylinder, causing nozzle to be
blocked.
When unit has stopped
spraying for a long time and
cylinder is not always
lubricated.
Max Flow Min Flow
Sweet Spot Setting
Quick Air Dry
WARNING: DO NOT USE FLAMMABLE LIQUIDS IN THE ELECTRIC GUN.
WARNING: DO NOT USE WATER IN THE ELECTRIC GUN.
WARNING: EXTREMELY HIGH PRESSURE JET OF FLUID. KEEP HANDS CLEAR AND POINT IN A SAFE DIRECTION.
Problem Possible Cause Solution
*For use with Non-flammable and
Non- Aqueous products only.
SG-5500
www.c cidom.com
extile Cleaning Gun
10V / 60Hz
1 2 3 4 5 6
Connect air hose (orange)
to the gun. Push tubing
completely over barb fitting.
Tighten retaining nut
clockwise,hand tight.
Connect quick disconnect
fitting to regulated air supply.
Use thumb to
operate quick
air dry feature.
SG-5500
www.ccidom .c om
extile Cleaning Gun
10V / 60Hz
VISIT US ONLINE
SourceOne.Nazdar.com
CALL US
888-578-5713
© 2016 Nazdar. All Rights Reserved.
Specifications subject to change without notice.
THIS PRODUCT IS BROUGHT TO YOU BY

Popular Cleaning Equipment manuals by other brands

Alfalaval Toftejorg SaniJet 20 instruction manual

Alfalaval

Alfalaval Toftejorg SaniJet 20 instruction manual

E-MAG Emmi 04 quick start guide

E-MAG

E-MAG Emmi 04 quick start guide

Alfalaval Toftejorg SaniMidget SB instruction manual

Alfalaval

Alfalaval Toftejorg SaniMidget SB instruction manual

Speed Clean Mini-Split Cassette Bib Kit Operating & maintenance instructions

Speed Clean

Speed Clean Mini-Split Cassette Bib Kit Operating & maintenance instructions

Parkside 102800 original operation manual

Parkside

Parkside 102800 original operation manual

Arcora WD 22 P Use and maintenance

Arcora

Arcora WD 22 P Use and maintenance

SJE OPTIMA X Series user manual

SJE

SJE OPTIMA X Series user manual

Pro-Ject Audio Systems VC-S3 Instructions for use

Pro-Ject Audio Systems

Pro-Ject Audio Systems VC-S3 Instructions for use

Mytee Dry GT user manual

Mytee

Mytee Dry GT user manual

Kärcher SP 9.000 Flat manual

Kärcher

Kärcher SP 9.000 Flat manual

Castex SCX-800 Operator and parts manual

Castex

Castex SCX-800 Operator and parts manual

Kooper Tornado 2420593 User instructions

Kooper

Kooper Tornado 2420593 User instructions

Kärcher PROCHEM Peak GTX2 operating instructions

Kärcher

Kärcher PROCHEM Peak GTX2 operating instructions

Truvox CIMEX X46 user manual

Truvox

Truvox CIMEX X46 user manual

Bosch UniversalBrush 3 603 CE0 0 Series Original instructions

Bosch

Bosch UniversalBrush 3 603 CE0 0 Series Original instructions

Graymills TL-Series Operation and maintenance instructions

Graymills

Graymills TL-Series Operation and maintenance instructions

Tab R6 user manual

Tab

Tab R6 user manual

KENT Ozone Disinfection Box Instruction handbook for installation, operation and maintenance

KENT

KENT Ozone Disinfection Box Instruction handbook for installation, operation and maintenance

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.