Chemyx Fusion 4000 User manual

FUSION 4000 & 6000
USER MANUAL

2
EU Declaration of Conformity (DoC)....................................................................................................................6
General Description...............................................................................................................................................7
Warranty and Repair Information........................................................................................................................9
Warranty Information................................................................................................................................9
Repair Facilities and Parts........................................................................................................................10
Dead Pixel Policy......................................................................................................................................10
Serial Numbers.........................................................................................................................................10
Calibrations.........................................................................................................................................10
ProductOverview..................................................................................................................................................11
Principle of Operation..............................................................................................................................11
Controlled Elements.................................................................................................................................12
Specications...............................................................................................................................................15
Pump Setup...........................................................................................................................................................17
PoweringOn/OthePump....................................................................................................................17
Loading a Syringe.....................................................................................................................................18
AdjustingtheSafetyNut/StallRod........................................................................................................21
Pump Operation......................................................................................................................................22
Mode Selection Screen............................................................................................................................24
Pressure&TemperatureSettings(Fusion6000only).......................................................................25
Basic Mode............................................................................................................................................................26
Syringe Selection......................................................................................................................................26
Volume......................................................................................................................................27
Infusion/Withdrawal.................................................................................................................................28
Flow Rate..................................................................................................................................................28
Start-Time Delay......................................................................................................................................29
Step Loop..................................................................................................................................................29

3
Options...........................................................................................................................................................30
Flow-Rate Units........................................................................................................................................30
Options....................................................................................................................................31
Enable Volume Lock.................................................................................................................................31
Multi-Step Mode...................................................................................................................................................32
Setup.......................................................................................................................................32
Syringe Selection.....................................................................................................................................32
Total Steps................................................................................................................................................33
Loop All.....................................................................................................................................................33
Sub-Loops...........................................................................................................................................33
Flow-Rate Units........................................................................................................................................34
Step Parameters...................................................................................................................................................34
Volume.......................................................................................................................................35
Pump Control.......................................................................................................................................................36
System Settings....................................................................................................................................................39
Pump Control by Computer...............................................................................................................................41
Cable Requirements............................................................................................................................................41
Connecting............................................................................................................................................................41
COM Port Settings....................................................................................................................................42
Pump Commands................................................................................................................................................43
ChemyxPumpControllerPrograms.................................................................................................................48
Pump Maintenance.............................................................................................................................................49
Lubricating the Pump.............................................................................................................................49
Lubrication Instructions.........................................................................................................................49
Approved Lubricants...............................................................................................................................49
PumpAccessories................................................................................................................................................50

4
Appendices.................................................................................................................................................52
Appendix A: Syringe Volume/Diameter Reference............................................................................52
AppendixB:AvailableParts....................................................................................................................56
AppendixC:ContactInformation...........................................................................................................57

5
INTELLECTUAL PROPERTY
AllIntellectualProperties,asdenedbelow,ownedbyorwhichisotherwisethepropertyofChemyxInc.oritssuppliersrelatingtotheChemyxsyringepumps,includingbutnotlimitedto,accessories,
partsorsoftwarerelatingthereto(ChemyxSyringePumps),areproprietarytofederalandstatelaws,andinternationaltreatyprovisions.IntellectualPropertyincludesbutisnotlimitedto,inventions
(patentableorunpatentable),patents,tradesecrets,copyrights,software,rmware,computerprograms,andrelateddocumentationandotherworksofauthorship.Moreover,youagreethatyouwill
not,andwillnotattemptto,modify,preparederivativeworksof,reverseengineer,disassembletheChemyxsyringepumps,decompileorotherwiseattempttocreatesourcecodefromtherelated
software/rmware.NotitletoorownershipinIntellectualPropertyistransferredtoyou.AllapplicablerightsoftheIntellectualPropertyshallremainwithChemyxanditssuppliers.

6
Declaraon of Conformity
The PDF version of the latest DoC can be downloaded at www.chemyx.com/support
EU Declaration of Conformity (DoC)
We:
Declare that the DoC is issued under the sole responsibility of the manufacture and belongs to
the following product(s):
All Syringe Pump Model Names, including:
- Fusion 100
- Fusion 200
- Fusion 4000
- Fusion 6000
- Nexus 3000
- Nexus 6000
- NanoJet StereoTaxic
- Fusion 100T
- OEM
The object of the declaration described above is in conformity with the relevant Union harmo-
nization legislation:
The technical documentation required to demonstrate that the products meet the
requirements of the LV and EMC directives has been compiled and is available for
inspection by the relevant enforcement authorities.
Signature on behalf of manufacturer:
Authority:
Date:
Chemyx, Inc.
10905 Cash Road
Stafford, TX 77005
(281) 277-5499
sales@chemyx.com
- EN 613326-1: 2013 Electrical Components for measurement, control, and
laboratory use - EMC requirements - Part 1: General Requirements
- EN 61010-1: 2010 European Low Voltage Directive 2014/35/EU Safety
requirements for electrical equipment for measurement, control, and
laboratory use Part 1: General Requirements
- Directive 2011/65/EU of the European Parliament and of the Council of 8 June
2011 on the restriction of the use of certain hazardous substances in electrical
and electronic equipment.
Attention!
The attention of the specifier, purchaser, installer, or user is drawn to special measures and limitations to use which
must be observed when these products are taken into service to maintain compliance with the above directives.
Details of these special measures and limitations to use are available on request,
and are also contained in the product manuals.
Jeff Wu, Senior Engineer, Chemyx, Inc.
Date: March 1, 2018

7
General Descripon
manufacturer; warranty coverage provided by the equipment may be dropped as a result.
CHEMYX PRODUCTS ARE NOT APPROVED FOR CLINICAL USE ON HUMANS.
power converter from 220V to 110 V while in the 220V environment or vice versa.
The product should be properly grounded.
USE PROPER POWER SUPPLY
GROUND PRODUCT
Safety Informaon
connectors on or in the product.
DO NOT OPEN THE PUMP
DO NOT OPERATE WITH SUSPECTED FAILURES
PINCH HAZARD
Read all labels on the product to ensure proper usage.
OBSERVE ALL WARNING LABELS ON PRODUCT
CHEMYX IS NOT RESPONSIBLE FOR SYRINGE DAMAGE
CHEMYX IS SAFETY PRECAUTIONS

8
Warranty and Repair Informaon
) before returning a product.
Chemyx Inc.
Warranty Informaon
Improper or inadequate maintenance or operation.
Unauthorizedmodicationormisuseoftheproduct.
Operationoutsidetheelectricalspecicationsfortheproduct.
Operationoutsidethetemperaturespecicationsfortheproduct.
User-inducedinternalandexternalcontaminationsoftheinstrument.
Failure to use proper surge protection.
Improperproductreturn,packaging,andshipping
Removing serial number from syringe pump

9
us at
number to you.
Chemyx Returns
number label will void the warranty.
not responsible for errors generated from syringes.
Repair Facilies and Parts
Dead Pixel Policy
Serial Numbers
Calibraons

10
Product Overview
years of constant and reliable service.
into the syringe.
PRINCIPLE OF OPERATION

11
+1281-277-5499|www.chemyx.com
Controlled Elements
Syringe Holder Block
Safety Rod Lead Screw
PusherBlock
Syringe Clamp
SyringeChannels
Fusion 6000 pump components

12
+1281-277-5499|www.chemyx.com
elements by touch only requires a small amount of pressure; however, please do not use sharp objects as they may damage
the screen.
running, paused, or stopped.
CONTROLS
Navigation Keypad
Front Panel of Pump
Pump Controls Numeric Keypad

13
+1281-277-5499|www.chemyx.com
channel in place during infusion and withdrawal.
of both infusion and withdrawal on a single pump channel.
the syringe in place during both infusion and withdrawal.
Bracket Release Knob
Bracket Release Knob
Flange Retaining Bracket
Flange Retaining Bracket
Plunger Retaining Bracket
Plunger Retaining BracketBracket Release Knob
FUSION 4000 SPECIFIC COMPONENTS
FUSION 6000 SPECIFIC COMPONENTS

14
Specicaons
Specicaon Fusion 4000 Fusion 6000
Movement Modes Infusion/
Withdrawal
Infusion/
Withdrawal
SyringeSizes
W(Min/Max) 0.5μL/140mL 0.5μL/255mL
Flow Rate Range (Smallest Syringe) 0.0001 to
1.08μL/min
0.0001 to
1.5679μL/min
Flow Rate Range (Largest Syringe) 0.0002 mL/min
to 128 mL/min
0.0002 mL/min
to 128 mL/min
DriveMechanism 0.9°steppermotorwith
1/128 microstepping
0.9°steppermotorwith
1/48 microstepping
Step Resolution 0.012μm/step 0.046μm/step
Nominal
Linear Force 29kg(65lbs) 227kg(500lbs)
Accuracy ±<0.35% ±<0.35%
Reproducibility ±<0.05% ±<0.05%
Operation Temp 4°C to 40°C
(40°F to 104°F)
4°C to 40°C
(40°F to 104°F)
Storage Temp -10°C to70°C
(14°Fto158°F)
-10°C to 70°C
(14°Fto158°F)

15
Specicaons (Connued)
Specicaon Fusion 4000 Fusion 6000
Data Ports
28cm (11in) 28cm (11in)
Width 26cm (10in)
Weight

16
Pump Setup
power supply.
currently installed on the pump at the top of the screen.
seconds as indicated by the countdown on the right of the
startup screen.
last mode the pump was in.
Powering On/O the Pump

17
however, some use cases may require syringes that are more accurate and durable.
Loading a Syringe
FUSION 4000
2
3
14
1.
2.
secure the syringe in place.
safety collar
angebracketknob
pusherblockknob
clamp

18
57
68
6.
8.
plunger bracket knob
pusherblockknob
plunger bracket knob
angebracketknob

19
1.
2.
screw the syringe clamp to secure the syringe in place.
syringe plunger.
FUSION 6000
2
1
3
567
8
6.
syringe plunger. The plunger cap for the syringe should
8.
place.
safety rod
pusherblock
clamp
plunger bracket knob pusherblock plunger bracket knob
angebracketknob

20
hits the safety mechanism and can no longer move forward, the pump will stop running, emit a long beep, and enter
Adjusng the Safety Nut/ Stall Rod
safety collar allows for the collar to be slid freely along the
top of syringe plunger when fully depressed.
The Fusion 6000 uses a stall rod instead of a collar to limit
set such that the length of the bar exposed on the right
the top of a fully depressed syringe plunger to the edge
FUSION 4000
FUSION 6000
Cauon:
This manual suits for next models
1
Table of contents
Popular Laboratory Equipment manuals by other brands

Millipore
Millipore Helicon S10 installation guide

Tuttnauer
Tuttnauer Elara 11 Technician manual

Agilent Technologies
Agilent Technologies 1290 Infinity II user manual

Nüby
Nüby IDVP50 manual

Thermo Scientific
Thermo Scientific EASY-Spray Series user guide

WLD-TEC
WLD-TEC gasprofi1 micro operating instructions

Radiometer Analytical
Radiometer Analytical TitraLab 980 Reference manual

Shimpo
Shimpo RK-3D instruction manual

Kendro
Kendro SORVALL Legend MACH 1.6/R instruction manual

SciCan
SciCan STATIM 7000 Field training manual

Thermo Scientific
Thermo Scientific Savant SpeedVac SPD140DDA Installation and operation

Bertin Technologies
Bertin Technologies Cryolys Evolution user manual