CHIEF LW46UxP User manual

I N S T A L L A T I O N I N S T R U C T I O N S
46"/47"/48"/49"/50"/55" Portrait Wall Kiosks
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
LW46/47/48/49/50/55UxP

LW46/47/48/49/50/55UxP Installation Instructions
2
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively “Milestone”), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
Lever Lock™ is a trademark of Middle Atlantic Products, Inc. All
rights reserved.
DEFINITIONS
MOUNTING SYSTEM: A MOUNTING SYSTEM is the
primary Chief product to which an accessory and/or component
is attached.
ACCESSORY: AN ACCESSORY is the secondary Chief
product which is attached to a primary Chief product, and may
have a component attached or setting on it.
COMPONENT: A COMPONENT is an audiovisual item
designed to be attached or resting on an accessory or mounting
system such as a video camera, CPU, screen, display,
projector, etc.
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all mounting systems
are properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this mounting system can result in serious personal injury
or damage to equipment! It is the installer’s responsibility to
make sure the structure to which this mounting system is
attached can support five times the combined weight of all
equipment. Reinforce the structure as required before
installing the mounting system.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components attached to mounting system does not
exceed:
•LW46/47/48UxP Models: 100 lbs (45.4 kg)
•LW49/50/55UxP Models: 125 lbs (56.7 kg)
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Do not use this mounting system outdoors.
IMPORTANT ! :
The LW46/47/48/49/50/55UxP portrait wall
kiosks are designed to be mounted to an:
• a bare 8" concrete or 8"x8"x16" concrete block wall; or
• a 2" x 4" wood studs (16" on center minimum) wall with
a maximum drywall thickness of 5/8"; or
• a steel stud (16" on center minimum to 24" on center
maximum) wall with a maximum drywall thickness of
5/8".
NOTE: The kiosks have an adjustable depth of 3" to 5".
--SAVE THESE INSTRUCTIONS--

Installation Instructions LW46/47/48/49/50/55UxP
3
DIMENSIONS
46.50
1181.1
27.50
698.5
22.50
571.5
LW46UxP
DIMENSIONS: INCHES
[MILLIMETERS]
46.50
1181.1
27.50
698.5
23.00
584.2
LW47UxP
DIMENSIONS: INCHES
[MILLIMETERS]

LW46/47/48/49/50/55UxP Installation Instructions
4
DIMENSIONS--continued
46.50
1181.1
27.50
698.5
23.50
596.9
LW48UxP
DIMENSIONS: INCHES
[MILLIMETERS]
LW49UxP
DIMENSIONS: INCHES
[MILLIMETERS]

Installation Instructions LW46/47/48/49/50/55UxP
5
DIMENSIONS--continued
LW50UxP
DIMENSIONS: INCHES
[MILLIMETERS]
54.25
1378.0
32.50
825.5
26.84
681.8
LW55UxP
DIMENSIONS: INCHES
[MILLIMETERS]
LW55UxP

LW46/47/48/49/50/55UxP Installation Instructions
6
LEGEND
TOOLS REQUIRED FOR INSTALLATION
PARTS
Phillips Screwdriver
Destornillador Phillips
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Open-Ended Wrench
Llave de boca
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Clé à fourche
Drill Hole
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Percez un trou
Hex-Head Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Zeskantsleutel
Clé à tête hexagonale
7/32" (wood studs)
#2
1/2"
5/32" (security)
5/16" (concrete)
1/2" (steel studs)
[included]
Hardware Bag -
Wall Hardware Hardware Bag - Monitor Interface Hardware
Hardware Bag -
Security/Swap Hardware
AA (8)
5/16 x 2-1/2"
AB (8)
5/16"
AC (4)
1/4-20
SnapToggle
AD (4)
AE (4)
1/4-20 x 1-3/4"
1/4"
BA (4)
M4 x 12mm
BD (4)
M5 x 12mm
BG (4)
M6 x 12mm
BJ (4)
M8 x 12mm
BB (4)
M4 x 25mm
BC (4)
M4 x 50mm
BE (4)
M5 x 25mm
BF (4)
M5 x 50mm
BH (4)
M6 x 25mm
BI (4)
M6 x 50mm
BK (4)
M8 x 25mm
BL (4)
M8 x 50mm
BM (8)
.750x.344x.500"
BO (4)
[universal
washer]
5/32"
(security)
CA (1)
10-24 x 3/8"
CB (4)
10-32 x 3/4"
CC (4)
10-32 x 5/16"
A (1)
[Enclosure assembly]
(LW49UxP shown
as example)
BN (8)
.750x.323x.250"AF (8)
UX10x60R
CD (4)
10-24 x 2-3/4"
NOTE: Letters match markings on hardware bags
CE (4)
10-24 x 3-1/2"
[not used]

Installation Instructions LW46/47/48/49/50/55UxP
7
ASSEMBLY AND INSTALLATION
Preparing Wall Bracket
1. Remove kiosk from the packaging and place on a flat surface. (See Figure 1)
2. Open hinged frame to 90°.
3. Keeping the hinged frame at 90° slide the hinged frame about 1 inch towards top of kiosk until hinge pins clear the hinges, and
move the hinged frame away from the wall bracket. (See Figure 1)
Figure 1
3
2
Hinged frame
Wall bracket
NOTE: The kiosks ship with the Lever Lock™ internal
management system shelf already in place. The shelf
may be removed to add components as required, and
then reinstalled. (See instructions included with the
shelf.)
IMPORTANT ! : The kiosks ship with the hinge located
on the left side. The hinge location may be switched, if
required, for installation or service. Before beginning
the installation, decide on which side the hinge should
be located and, if you require the kiosk be hinged on the
right side, switch the hinge before completing any other
installation steps. See Switching Hinge Location
section in Appendix.
Locate Mounting Site
WARNING:
IMPROPER INSTALLATION CAN LEAD TO
MOUNT FALLING CAUSING SEVERE PERSONAL INJURY
OR DAMAGE TO EQUIPMENT! It is the installers responsibility
to make certain the structure to which the mount is being
attached is capable of supporting five times the combined
weight of all components located on the mount:
•LW46/47/48UxP Models: 100 lbs (45.4 kg)
•LW49/50/55UxP Models: 125 lbs (56.7 kg)
Installing Wall Bracket
The LW
46/47/48/
49/50/55UxP wall kiosk mounts are designed
to be mounted to:
• a bare 8" concrete or 8"x8"x16" concrete block wall; or
• a 2" x 4" wood studs (16" on center minimum) wall with
a maximum drywall thickness of 5/8"; or
• a steel stud (16" on center minimum to 24" on center
maximum) wall with a maximum drywall thickness of 5/8".
Table 1: Fastener Inform
WALL
TYPE
PILOT
HOLE
FASTENERS (see PARTS
drawing)
Steel
stud /
Wood
stud
1/2"
7/32"
- 1/4-20 x 1-3/4" Phillips screw
(AD)
- 1/4" washer (AE)
- 1/4-20 Snap toggler (AC)
- 5/16 x 2-1/2" hex head lag (AA)
- 5/16" washer (AB)
Concrete 5/16 x 3-1/4" - 5/16 x 2-1/2" hex head lag (AA)
- 5/16" washer (AB)
- Fischer Anchor UX10x60R (AF)

LW46/47/48/49/50/55UxP Installation Instructions
8
1. Determine the center of the wall bracket, and where it
should be located on the wall. (See Figure 2)
NOTE: For wood or steel stud walls, use a level and mark the
two uppermost locations over studs for attachment a
minimum of 16" apart and a maximum of 24" apart.
(See Figure 2)
•For maximum stability in a wood or steel stud wall,
mount the hinge side of kiosk as close as possible to a
stud.
NOTE: For concrete walls, use a level and mark the two
uppermost locations for attachment as far apart as
possible to provide maximum stability. (See Figure 2)
Figure 2
NOTE: For wood or steel stud walls, use a level and mark the
two uppermost locations over studs for attachment a
minimum of 16" apart and a maximum of 24" apart.
(See Figure 2)
NOTE: For concrete walls, use a level and mark the two
uppermost locations for attachment as far apart as
possible. (See Figure 2)
2. Drill one pilot hole (see Table 1 for size) at both locations
marked in Step 1 (See Figure 2) and follow fastener
information (appropriate for wall type) located in Table 1.
IMPORTANT ! : Refer to Fastener Installation Methods
(located in Appendix at end of Installation Instructions)
for details on installing product into various wall types.
Figure 3
3. Partially install fasteners into wall, but do not completely
tighten to wall.
4. Hang wall bracket, aligning upper mounting slot clearance
holes over fasteners and adjust side-to-side for proper
location. (See Figure 3)
5. Tighten fasteners to secure wall bracket to wall at upper
mounting slots.
6. Drill six remaining pilot holes (see Table 1 for size) at
attachment locations and follow fastener information
(appropriate for wall type) located in Table 1. (See Figure 3)
7. Tighten six fasteners to secure wall bracket to wall at middle
and lower mounting slots.
x 2
1 2
Wall
bracket
Uppermost attachment area
5
6
x 2
7
[24" on-center attachment
shown as example only]
Clearance
holes
Mounting
slots

Installation Instructions LW46/47/48/49/50/55UxP
9
8. Insert four snap toggles and related fasteners into hinge
side of wall bracket. (See Figure 4)
IMPORTANT ! : Refer to Fastener Installation Methods
(located in Appendix at end of Installation Instructions)
for details on installing snap toggles and related
fasteners into various wall types.
Figure 4
Attaching Flat Panel
1. Remove and
SAVE
four Phillips screws, loosen four thumb
nuts and remove hinge frame from outer frame of kiosk door.
(See Figure 5)
Figure 5
2. Carefully lay flat panel face down into the depth-adjustable
outer frame. (See Figure 6)
Figure 6
3. Center flat panel on opening within outer frame in both
vertical and horizontal directions.
NOTE: Measuring from inside edges to display edges assists
in centering the display within opening.
WARNING: IMPROPER INSTALLATION CAN LEAD TO
DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Using screws of
improper size may damage your display. Properly sized
screws will easily and completely thread into display
mounting holes. If spacers are required, be sure to use longer
screws of the same diameter.
4. Select screw diameter by examining hardware (BA-BL) and
comparing with mounting holes on flat panel.
5. Select spacers:
• Spacers are NOT required if mounting holes are not
recessed and hinged frame can lay flat against flat
panel.
•Spacers (BM, BN) ARE required if mounting holes are
recessed, or if protrusions prevent hinged frame from
laying flat.
•Spacers may also be used between the hinge frame
and flat panel to create more space for AV
components. (See Depth Adjustment section for
further information.)
6. Select screw length:
• By hand, insert SHORTEST length screw of selected
diameter (BA, BD, BG, or BJ) through universal washer
(BO--if required), hinged frame, spacer (BM, BN--if
required), into flat panel mounting hole. Do NOT thread
screw into hole at this time.
IMPORTANT ! : The M8 screws do NOT require a
washer. Use the universal washer (BO) ONLY with the
M4, M5 or M6 screws.
• Proper screw length requires base of screw head to
protrude above flat washer a distance equal to or
greater than the screw diameter. If screw length is
inadequate, select longer screw. Select shortest screw
which will protrude the required distance.
8
Insert snap-toggles at arrows
1
x 4
Thumb
nut
1
Hinge
frame
Outer
frame
2
Depth-adjustable
outer frame
Flat panel
2

LW46/47/48/49/50/55UxP Installation Instructions
10
7. Place hinged frame onto back of flat panel and match the
VESA pattern on flat panel to the hinged frame mounting
slots. Also match the threaded studs in outer frame to the
hooks on the hinged frame. (See Figure 7)
8. Use selected screws (BA-BL), washers (BO--if required),
and spacers (BM, BN--if required), to connect hinged frame
to back of flat panel. (See Figure 7)
Figure 7
NOTE: The outer frame depth may be adjusted between
3" - 5" to make room for a variety of different flat panel
thicknesses. (See Figure 8)
• This outer frame adjustable depth can also be used to
make more space between the back of the flat panel
and wall for AV component storage.
• The 4 Phillips screws removed in Step 1 can be
replaced with four 10-24 x 2-3/4" Phillips screws (CD)
for larger depth adjustments.
Figure 8
9. Tighten thumb nuts over threaded studs in four locations on
the hinged frame. (See Figure 8)
10. Replace and fasten four Phillips screws which were
removed in Step 1, OR replace the removed screws with
four 10-24 x 2-3/4" Phillips head screws (CD) to allow for a
larger depth adjustment of the outer frame. (See Figure 8)
11. Carefully lift (using two people) the outer frame with
attached flat panel.
12. Keeping the outer frame at a 90° angle against the wall,
slide the outer frame so that hinge pins are above hinges.
13. Lower outer frame to engage hinge pins into hinges. (See
Figure 9)
Figure 9
14. Close outer frame door and add 10-24 x 3/8" button head
security screw (CA) in hole below latch to lock door. (See
Figure 9)
NOTE: Use universal washer (BO)
(BO)
(BM and/or BN)
8
(BA-BL) x 4
Outer
frame
ONLY with M4, M5 or
M6 screws.
9
Thumb nuts x 4
10
Previously
(CD) x 4
removed OR
[Flat panel not shown]
Hinge pin
Hinge
13
12
14
(CA x 1)
Outer
frame
Door must be closed before
Door
open
security screw (CA) is added

Installation Instructions LW46/47/48/49/50/55UxP
11
APPENDIX
Switching Hinge Location
1. Remove AND SAVE the hardware on the latch (right) side
of the wall bracket. (See Figure 10)
Figure 10
2. Remove and SAVE two lift-off hinges from hinged side of
wall bracket. (See Figure 11)
3. DISCARD the four fasteners from these hinge parts.
Figure 11
4. Remove and SAVE lift-off hinge and hinge spacer plate
from two locations on swing door assembly. (See Figure 12)
5. DISCARD the four fasteners from these hinge parts.
Figure 12
1
Remove and SAVE
fasteners noted
all parts and
Wall
bracket
2
Remove and
SAVE two hinges
Wall
bracket
Hinge
4
Remove and
SAVE two hinges
and hinge
spacer plates
Spacer
plate
Hinge
Swing door
assembly

LW46/47/48/49/50/55UxP Installation Instructions
12
6. Replace two lift-off hinges and hinge spacer plates onto
opposite side (left) of swing door assembly. (See Figure 13)
7. Fasten in place with four (two each hinge)
NEW
10-32 x 3/4"
button head cap screws (CB). (See Figure 13)
Figure 13
8. Move the lift-off hinges to the right side of the wall bracket.
(See Figure 14)
9. Fasten in place with four (two each hinge)
NEW
10-32 x 5/16"
button head cap screws (CC). (See Figure 14)
Figure 14
Lift-off
hinge
Hinge
spacer
plate
7
(CB) x 4
Wall bracket
9
(CC) x 4
Lift-off
hinge

Installation Instructions LW46/47/48/49/50/55UxP
13
10. Flip and install latch section on left side of wall bracket.
NOTE: Be sure that upper and lower tabs are slid into slots on
wall bracket. (See Figure 15)
11. Fasten in place with two washers and screws removed in
Step 1. (See Figure 15)
12. Re-install small horizontal tab removed from bottom of latch
section in Step 1, by fastening it onto the top of the latch
section. (See Figure 15)
13. Re-install outside latch using fastener removed in Step 1.
(See Figure 15)
14. Re-install inside latch: (See Figure 15)
a. Place spring on top of horizontal tab and compress
spring slightly.
b. Place latch over spring, lining up tabs on latch with slots
in wall bracket.
a. Fasten latch in place with button head cap screw and
washer removed earlier in Step 1.
Figure 15
x 2
11
Insert tab
at top and
into slot
bottom
10
12
Horizontal tab
13
Wall bracket
14a
14b
14c
x 1
Slots
Tabs
Spring

LW46/47/48/49/50/55UxP Installation Instructions
14
Fastener Installation Methods
IMPORTANT ! : See Table 1 for appropriate hardware
and pilot hole sizes for various wall types.
Wood Stud
1. Use one 5/16" x 2-1/2" hex flange head lag bolt (AA) and
one 5/16" washer (AB) through product and into pilot hole.
(See Figure 16)
2. Repeat for remaining pilot holes.
Figure 16
Concrete
1. Install one UX10X60R anchor (AF) into each pilot hole
using a hammer, making sure that the anchor is flush with
the wall. (See Figure 17)
2. Use one 5/16" x 2-1/2" hex flange head lag bolt (AA) and
one 5/16" washer (AB) through product into each anchor in
wall. (See Figure 17)
3. Repeat for remaining pilot holes.
Figure 17
Steel Stud
IMPORTANT ! : See Site Requirements for Steel Stud
Installation section before proceeding with Steel Studs
installation to ensure installation site meets
requirements! The drywall must have a minimum
thickness of 1/2"!
1. Hold metal channel on anchor (AC) flat alongside plastic
straps and slide channel through hole. (See Figure 18)
Figure 18
2. Holding plastic straps on anchor (AC), pull anchor away from
wall until channel rests flush behind wall making sure anchor
channel is positioned vertically on drywall, or steel stud (if
present). (See Figure 19)
3. Slide plastic cap on anchor (AC) towards wall until flange of
cap is flush with wall. (See Figure 19)
Figure 19
4. Snap off plastic straps on anchor at wall by pushing side to
side, snapping off straps level with flange of plastic cap.
(See Figure 20)
Figure 20
1
2
(AA) x 8
(AB) x 8
1
2
(AA)
(AF)
(AB)
(AC)
Drywall
Plastic straps
1
(AC)
Plastic cap
Drywall
Anchor metal channel
3
Steel stud
(side view)
2
(if present)
Plastic straps
Drywall
Anchor metal channel
Plastic cap
4
Steel stud
(side view)
(if present)

Installation Instructions LW46/47/48/49/50/55UxP
15
5. Line up anchor with attachment point.
6. Insert 1/4-20 x 1-3/4" Phillips pan head screw (AD) through
1/4" washer (AE), corresponding mounting hole in wall
bracket and into anchor (AC), and tighten until flush against
wall bracket. DO NOT over tighten! (See Figure 21)
Figure 21
Drywall
Anchor metal channel
(AD) x 4
6
Steel stud
(AE) x 4
(side view)
Wall bracket
(if present)
Site Requirements for Steel Stud Installation
Figure 22
Steel Stud (2 x 4 / 25ga minimum)
FRONT
There must be a minimum of
1-7/8" (48mm) clearance
inside wall
16" or 24" (on center) Studs
If back side of wall is unfinished,
to a minimum of one stud left
Stud type and structural strength must conform to the North American Specification for the
Drywall
**1/2" minimum
Drywall Thickness
(Both Sides of Stud)
**See Warning statement
on page 2!
Design of Cold-Formed Steel Structural Members. [362 S 125 18, C-Shaped, S-Stud Section]
drywall must be installed
and right of the stud(s) being used
to install the mount. Drywall must be
secured to studs with screws a
maximum of 12" (305mm) apart
down center of stud.

LW46/47/48/49/50/55UxP Installation Instructions
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P800.582.6480 / 952.225.6000
F877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P+31 (0) 495 580 852
F+31 (0) 495 580 845
Asia Pacific A Office No. 918 on 9/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P852 2145 4099
F852 2145 4477
Chief, a products division of
Milestone AV Technologies
8800-003033 Rev00
2018 Milestone AV Technologies
www.milestone.com
07/18
This manual suits for next models
5
Table of contents
Other CHIEF Industrial Equipment manuals