Christ PA10009320 User manual

09/2021
www.christ-es.com
Instruction manual
IndustrialsPC

Industrial PC
Instruction Manual
Document No.: PA10009320
2 / 33
Sep. 2021, Revision 00
1Identification 4
2Product description 6
2.1 System Overview 7
2.2 Housing Variant Industrial PC 8
2.3 Add-On 9
3Description Hardware 10
3.1 External Interfaces 10
4Environmental Conditions 15
4.1 Temperature test 15
4.2 IP Protection Class 15
5Assembly and Commissioning 16
5.1 Connection of the power supply 17
5.2 Earth Connection 17
5.3 Mounting Industrial PC 17
5.4 Dismounting Industrial PC 18
6Accessories and Spare Parts 19
7Software 20
7.1 BIOS Basic Settings 20
7.1.1 COM Port configuration 20
7.1.2 Set Boot Priority 21
7.2 BIOS Update 23
7.2.1 Preparation 23
7.2.2 Perform Update 23
7.3 OBS Client 25
7.3.1 Activating the OCB Client 25

Industrial PC
Instruction Manual
Document No.: PA10009320
3 / 33
Sep. 2021, Revision 00
7.3.2 Functions of the OBS Client 25
7.4 Redo Backup and Recovery 26
7.5 Enhanced Write Filter EWF 26
8Maintenance 27
8.1 Cleaning 27
8.2 Maintenance 27
9Technical Data 28
9.1 Mechanical Specifications 28
9.2 Electrical Specifications 28
9.2.1 Power Consumption 28
9.3 Electromagnetic Compatibility 29
9.4 Environmental Conditions 29
10 Standards and Approvals 30
10.1 CE Marking 30
10.2 RoHS 30
10.3 Electromagnetic Compatibility 30
10.4 Environmentally Appropriate Disposal 30
11 Technical Support 31
11.1 Device Seal 31

Industrial PC
Instruction Manual
Document No.: PA10009320
4 / 33
Sep. 2021, Revision 00
1Identification
Target group
This document is not intended for end customers! Necessary safety instructions for the end customer
must be passed on by the machine builder or system provider and adopted in the respective national
language.
Intended use
This product has not been designed, developed and manufactured for use that creates fatal risks and
hazards without exceptionally assured safety measures. These include death, injury, or serious physical
harm or otherwise caused loss. These represent nuclear response monitoring, nuclear control systems,
air traffic control, mass transportation control, medical life support systems, and weapons systems con-
trol.
Technical changes
Christ-Electronic Systems GmbH reserves the right to change the information, designs and technical
data contained in this documentation without prior notice.
Copyright
No part of this documentation may be reproduced in any form or processed, duplicated or distributed
using electronic systems without the prior written consent of Christ Electronic Systems GmbH. Even trans-
lation into another language requires written permission. This documentation is entrusted exclusively to
the owner of the device or employees of Christ Electronic Systems GmbH for personal use.
Trademarks
Trademark and product names are trademarks or registered trademarks of their respective owners.
History
The following editions of the manual have already been published:
Version
Comment
09/2021
First edition
Table 1: History

Industrial PC
Instruction Manual
Document No.: PA10009320
5 / 33
Sep. 2021, Revision 00
Design of safety instructions
DANGER
Indicates an imminent danger
Failure to follow the instructions may result in death or serious injury
WARNING
Indicates a dangerous situation
Failure to observe this warning may result in serious injury or major damage to
property
CAUTION
Indicates a possible dangerous situation
Failure to observe the advice can result in injuries or property damage
NOTICE
Indicates user tips and useful information
Important information to avoid malfunctions

Industrial PC
Instruction Manual
Document No.: PA10009320
6 / 33
Sep. 2021, Revision 00
2Product description
Industrial PCs, as the heart of the machines in control cabinets, ensure smooth operation. The require-
ments placed on them are very different. For this reason, we offer our customers numerous product var-
iants.
For a particulary long livetime, there are no moving parts in the Industrial PCs. The Box PCs with passive
cooling are therefore also particularly suitable for harsh industrial environments.
Another advantage is the industrial-grade components that are available over a long period of time.
The optional integrated UPS prevents data loss during power fluctuations. If the power fails, the devices
are shut down properly.
The Industrial PCs can be loaded with either Windows or Linux before delivery and are then immedi-
ately ready for use.
Thanks to the compact housing design, Christ Industrial Computers can also be optimally used in con-
fined spaces. Despite their small size, they deliver high performance when required.
Whether for IIoT applications or computing-intensive automation applications, the portfolio of industrial
PCs meets a wide range of requirements. The processor performance classes Intel® Celeron® or Intel®
Core™ i3, i5, or i7 are suitable for a wide range of applications.
Memory expansion is also possible without any problems.

Industrial PC
Instruction Manual
Document No.: PA10009320
7 / 33
Sep. 2021, Revision 00
2.1 System Overview
Argon
CPU
Intel® Celeron™ N3350 1.1 GHz
Graphic
Intel® HD Graphics 500 200 Hz
Memory
1 x DDR3 Slot, max. 8 GB
BIOS
AMI Optio 5 BIOS
Interfaces
2 x USB 3.0 Port (Type A)
2 x 1 GBit Ethernet (RJ45)
1 x RS-232 / RS-422 / RS-485 (Bios setting) (RJ50)
1 x Display Port 1.0
Table 2: System overview Argon
Titanium
CPU
Intel®
Celeron™
3965U 2.2
GHz
Intel® Core™
i3-7100U 2.4
GHz
Intel® Core™
i5-7300U 2.6
GHz
Intel® Core™
i7-7600U 2.8
GHz
Graphic
Intel® HD
Graphics 610
Intel® HD Graphics 620
Memory
2 x DDR4 slot, in summary max. 32 GB
BIOS
AMI Optio 5 BIOS
Interfaces
4 x USB: 2 x USB 2.0 Port (Type A); 2 x USB 3.0 Port (Type A)
2 x 1 GBit Ethernet (RJ45)
1 x RS-232 / RS-422 / RS-485 (Bios setting) (Sub-D)
1 x Display Port 1.1
Table 3: System overview Titanium

Industrial PC
Instruction Manual
Document No.: PA10009320
8 / 33
Sep. 2021, Revision 00
2.2 Housing Variant Industrial PC
Illustration 1: Industrial PC
1
DIN Rail, 35 mm x 7.5 mm, DIN Rail 35 mm x 15 mm
2
Interface Area
Table 4: Industrial PC Front
Illustration 2: Dimensions Industrial PC
Architecture
A
B
C
D
Argon
180
130
33
90
Titanium
230
160
33
115
Table 5: Dimensions Industrial PC

Industrial PC
Instruction Manual
Document No.: PA10009320
9 / 33
Sep. 2021, Revision 00
2.3 Add-On
UPS (Uninterruptible Power Supply)
Energy Storage
400 Ws
Charge Duration
90 % in 45 seconds
100 % in 80 seconds
Configuration
Shutdown Time
Dimming Time
Dimming Intensity
The instruction for the UPS can be found in the FAQ section of the Christ website: FAQ - Questions and
Answers

Industrial PC
Instruction Manual
Document No.: PA10009320
10 / 33
Sep. 2021, Revision 00
3Description Hardware
3.1 External Interfaces
Power Supply
CAUTION
External cable for Power Supply, Signal or Periphery
Malfunction occur
➢Prepare a proper earth connection on the power pack
Supply Connector screwable
Mating
Connector
Phoenix Connector MC 1,5 / 3-STF-3.5 (screwable)
PIN
Function
Description
1
GND
Ground
2
FE
Functional Earth
3
+24 VDC
Supply
Table 6: Pinout Supply Connector screwable
USB Host 2.0 (Type A)
PIN
Function
Description
1
VBUS
USB VCC
2
D-
USB Data-
3
D+
USB Data+
4
GND
USB Ground
Table 7: Pinout USB 2.0
USB Host 3.0 (Type A)
PIN
Function
Description
1
VBUS
USB VCC
2
D-
USB Data-
3
D+
USB Data+
4
GND
USB Ground
5
StdA_SSRX-
SuperSpeed transmitter differential pair
6
StdA_SSRX+
SuperSpeed transmitter differential pair
7
GND_DRAIN
Ground for signal return
8
StdA_SSTX-
SuperSpeed receiver differential pair
9
StdA_SSTX+
SuperSpeed receiver differential pair
Table 8: Pinout USB 3.0

Industrial PC
Instruction Manual
Document No.: PA10009320
11 / 33
Sep. 2021, Revision 00
Ethernet
PIN
Function
Description
1
D1+
Transmit Data +
2
D1-
Transmit Data -
3
D2+
Receive Data+
4
D3+
Bidirectional +
5
D3-
Bidirectional -
6
D2-
Receive Data -
7
D4+
Bidirectional +
8
D4-
Bidirectional -
Table 9: Pinout Ethernet
WLAN
Mating
Connector
SMA / RP-SMA
Description
Transmis-
sion Stand-
ard
802.11 ac/a/b/g/n (2.4 GHz, 5 GHz)
Table 10: Pinout WLAN

Industrial PC
Instruction Manual
Document No.: PA10009320
12 / 33
Sep. 2021, Revision 00
COM Connector (Titanium)
RS-232
RS-422
RS-485
PIN
Func-
tion
Description
Function
Description
Function
Description
1
DCD
Data Carrier
Detect
TX-
Transmitter
Differential
Pair -
DATA-
Data Differ-
ential Pair A
2
RX
Receive Data
TX+
Transmitter
Differential
Pair +
DATA+
Data Differ-
ential Pair B
3
TX
Transmit
Data
RX+
Receiver Dif-
ferential Pair
+
n.c.
not con-
nected
4
DTR
Data Trans-
mit Ready
RX-
Receiver Dif-
ferential Pair
-
n.c.
not con-
nected
5
GND
Ground
GND
Ground
GND
Ground
6
DSR
Data Set
Ready
n.c.
not con-
nected
n.c.
not con-
nected
7
RTS
Ready To
Send
n.c.
not con-
nected
n.c.
not con-
nected
8
CTS
Clear To
Send
n.c.
not con-
nected
n.c.
not con-
nected
9
RI
Ring Indica-
tor
n.c.
not con-
nected
n.c.
not con-
nected
Table 11: Pinout COM Connector Titanium

Industrial PC
Instruction Manual
Document No.: PA10009320
13 / 33
Sep. 2021, Revision 00
COM Connector (Celeron N3350 Argon)
RS-232
RS-422
RS-485
PIN
Func-
tion
Description
Function
Description
Function
Description
1
DSR
Data Set
Ready
n.c.
not con-
nected
n.c.
not con-
nected
2
GND
Ground
GND
Ground
GND
Ground
3
GND
Ground
GND
Ground
GND
Ground
4
TXD
Transmit
Data
RX+
Receiver Dif-
ferential Pair
+
n.c.
not con-
nected
5
RXD
Receive Data
TX+
Transmitter
Differential
Pair +
DATA+
Data Differ-
ential Pair B
6
DCD
Data Carrier
Detect
TX-
Transmitter
Differential
Pair -
DATA-
Data Differ-
ential Pair A
7
DTR
Data Termi-
nal Ready
RX-
Receiver Dif-
ferential Pair
-
n.c.
not con-
nected
8
CTS
Clear To
Send
n.c.
not con-
nected
n.c.
not con-
nected
9
RTS
Request To
Send
n.c.
not con-
nected
n.c.
not con-
nected
10
RI
Ring Indica-
tor
n.c.
not con-
nected
n.c.
not con-
nected
Table 12: Pinout COM Connector Celeron N3350 Argon

Industrial PC
Instruction Manual
Document No.: PA10009320
14 / 33
Sep. 2021, Revision 00
Display Port
PIN
Function
Description
1
DP data 0+
DP data 0+
2
GND
Ground
3
DP data0-
DP data0-
4
DP data1+
DP data1+
5
GND
Ground
6
DP data1-
DP data1-
7
DP data2+
DP data2+
8
GND
Ground
9
DP data2-
DP data2-
10
DP data3+
DP data3+
11
GND
Ground
12
DP data3-
DP data3-
13
CONFIG1 CAD
Cable adapter recognized
14
CONFIG2
Ground (Pull-Down)
15
AUX_CH+
Additional device +
16
GND
Ground
17
AUX_CH-
Additional device -
18
HPD
Hot Plug recognized
19
GND
Ground
20
DP_PWR 3,3V
Power Supply DP
Table 13: Pinout Display Port
With the DP1.0 it is not possible to display an image on DVI / HDMI devices. An
active adapter with properties of DP++ is required for this.1
Display Port 1.1 is also known as "Dual-Mode Display Port" and "Display
Port++". This allows compatibility with DVI and HDMI.
1
The Argon board uses DP1.0

Industrial PC
Instruction Manual
Document No.: PA10009320
15 / 33
Sep. 2021, Revision 00
4Environmental Conditions
WARNING
Insufficient air supply to the device
Overheating
➢Never cover the device completely or operate it in a small, unventilated
housing
4.1 Temperature test
The values for operating temperature and humidity were determined under worst-case conditions. The
maximum workload of the system was achieved by the BurnInTest from PassMark Software Pty Ltd.
The test ran under 100 % utilisation of:
•CPU
•RAM
•2D and 3D Graphic (x86 only)
•Brightness of the display
4.2 IP Protection Class
The protection class only can be guaranteed under the following conditions:
•The device is installed correctly
•All components and covers of the interfaces are assembled
•Compliance with all environmental conditions

Industrial PC
Instruction Manual
Document No.: PA10009320
16 / 33
Sep. 2021, Revision 00
5Assembly and Commissioning
This chapter describes all the steps for assembly. The following warnings are safety instructions that
must be applied throughout the assembly chapter and in every other life cycle of the device.
DANGER
Danger from electric shock, explosion or electric arc
Serious injury or death
➢Pull out the mains plug and do not open the covers
WARNING
Dropping a device
Injuries and bruises to the legs and / or feet
➢Wear safety shoes
Note for the installation site
This device is not designed for outdoor use.
Make sure that the ambient temperature and humidity are within the ranges which are specified under
Environmental Conditions.
Do not install the device directly in the sunlight.
Make sure that the device is installed so that is accessible for the operator.
Installation instructions
Check the package contents for any visible damage and for completeness.
In case of damage, do not install the device and contact the Christ Service.

Industrial PC
Instruction Manual
Document No.: PA10009320
17 / 33
Sep. 2021, Revision 00
5.1 Connection of the power supply
Use conductors with a cross-section of 0.75 mm² to 1.5 mm². Use the MC 1,5/ 3-STF-3,5
BKBDWH:GND Q PCB connector from Phoenix.
Strip the insulation from the individual wires of the conductor (1). Insert these into the connection con-
tacts (3) of the PCB connector and tighten the screw contacts (2) with a screwdriver and a maximum
torque of 0.3 Nm.
The rear view (4) of the connector is shown for clarification.
Illustration 3: Connection of the power supply
5.2 Earth Connection
NOTICE
Earthing not connected
Not guaranteed functionality of the device
➢All earth connections must be connected to an earth point
5.3 Mounting Industrial PC
Step 1:
Hook the Industrial PC onto the fastening rail at
an angle from above. Press the Industrial PC
down until it hooks into place.
Step 2:
The industrial PC hangs on the fastening rail.
Illustration 4: Mounting Industrial PC Step 1
Illustration 5: Mounting Industrial PC Step 2

Industrial PC
Instruction Manual
Document No.: PA10009320
18 / 33
Sep. 2021, Revision 00
5.4 Dismounting Industrial PC
Step 1:
Pull down on the pull cord to release the Indus-
trial PC.
Step 2:
Tilt the Industiral PC forward with the pull cord
pulled at the bottom and unhook it at the top.
Illustration 6: Dismounting Industrial PC Step 1
Illustration 7: Dismounting Industrial PC Step 2

Industrial PC
Instruction Manual
Document No.: PA10009320
19 / 33
Sep. 2021, Revision 00
6Accessories and Spare Parts
The accessories listed here have been checked by Christ and are compatible with the products.
The following accessories are available:
Power supply
Input Voltage
90 - 264 VAC
Input Current
max. 1 A
Input Frequency
47 - 63 Hz
Consumption with unloaded out-
put
max. 0.075 W
Output Voltage
24 VDC
Output Current
max. 2.5 A
Temperature Range Operation
0 - 70°C
Humidity Operation
20 - 80% RH non condensing
Table 14: Power supply

Industrial PC
Instruction Manual
Document No.: PA10009320
20 / 33
Sep. 2021, Revision 00
7Software
The x86 architecture has a BIOS (Basic Input Output System) for the basic settings of the system. This is
not present in the ARM architectures. Here, updates are performed with CURT (Christ Update and Re-
covery Tool).
7.1 BIOS Basic Settings
AMI BIOS ROM has built-in settings program that allows users to make basic settings. This information
is stored in a battery supported CMOS RAM, so it remains stored even when there is no power supply.
Accessing the BIOS works by pressing the "Del" key several times while the device is booting.
The following tabs in the BIOS enable various settings.
Main
Set date
Advanced
Make advanced BIOS settings like: COM, ACPI, etc.
Chipset
Enter host bridge parameters
Security
Set administrator password
Boot
Set Boot Option
Save & Exit
Save the settings made and initiate a restart. (Also possible with
the F4 key on the keyboard)
Table 15: BIOS
Pressing F3 and confirming the query "Load Optimized Defaults?" with "Yes" restores the delivery state.
Illustration 8: BIOS
7.1.1 COM Port configuration
COM Port configuration
Argon
In order for RS-232, RS-422 and RS-485 to be recognized on the COM port, the following settings must
be made in the BIOS:
Table of contents
Other Christ Industrial PC manuals
Popular Industrial PC manuals by other brands

DMP Electronics
DMP Electronics EBOX EB-AN Series user guide

Omron
Omron DYALOX INDUSTRIAL PC quick start guide

Wilke Technology
Wilke Technology ICOM 200 manual

ADLINK Technology
ADLINK Technology DLAP-4000 Series user manual

IFM
IFM moneo appliance QHA300 Instructions for setup

Xycom
Xycom 3700 Series user manual