Kit Contents
Chummie alarm unit, IntelliFlex sensor, snap-on clip, Flexitape, 2
AAA batteries, user manual & quick start guide, progress chart,
warranty card.
The Chummie enuresis alarm is used to treat nighttime
bedwetting (nocturnal enuresis) in children 4 years of age
and older. When a bedwetting incident occurs, the sensor
detects urine and the alarm unit beeps, vibrates, and
lights flash to awaken your child. Over time, your child
will become conditioned to wake up more quickly with
each bedwetting incident and will eventually wake up
before wetting the bed. To prevent your child from becom-
ing accustomed to any one alarm, the alarm unit can play-
back 5 different tones and users can control vibration.
Use the progress diary to track your child’s daily prog-
ress. A successful treatment requires persistence and
positive reinforcement and can take a few months.
Chummie should be used nightly until at least 14 consecu-
tive dry nights are achieved, after which the program may
be discontinued.
www.chummie.com
User Manual & Quick Start Guide (English)
Model TCE25
US and International patents pending.
PN/Ref.: TCE25. Doc.: TCE25-MN-EN-1. Rev. date: 04/2014.
Designed in USA. Manufactured in China.
© 2014 Theos Medical Systems, Inc. All Rights Reserved.
Chummie exceeds required performance, construction, and
safety requirements. The alarm unit is battery powered and
double insulated for added protection. Leakage current across
the sensor is less than required for medical surgical devices: less
than 8µA in any condition; less than 1µA when sensor is wet.
Chummie, IntelliFlex, One Drop Detection, Better Technology
for Faster Treatment, Flexitape, Comfy-Armband, Active Guard
Monitoring, Enhanced Protection Plus Care, SmartFit, and the
Chummie, Elite and Theos Medical Systems logos are
trademarks or registered trademarks of Theos Medical Systems,
Theos Medical Systems, Inc.
4601 Lafayette St., Suite 5445
Santa Clara, CA 95056, USA.
Tel: (408) 239-4050
Toll free: (800) 230-6775 (USA)
Fax: (408) 599-3020
email: [email protected]
www.chummie.com
www.theosmedical.com
Theos Medical Systems warrants the Chummie alarm unit for a
period of one (1) year and the IntelliFlex sensor for a period of
three (3) months against defects in material and workmanship
under normal use from the date of purchase. This warranty is
non-transferable and does not cover misuse, abuse or damage
from negligence. See warranty card for complete details.
For customer support and/or to purchase accessories, contact:
WARRANTY
The Chummie bedwetting alarm treatment system is not a toy;
keep it away from small children. The loud alarm may startle
your child when awakened; take adequate precaution to allow
your child to get used to the alarm tones. Always run the sensor
cord below the shirt. The sensor is not designed for multiple
users. Follow good hygiene practice by using a new sensor for
each child to be treated. Clean the alarm unit and sensor every
night prior to use.
WARNINGS
Do not mix old and new batteries. Replace old batteries with new
AAA batteries. Insert batteries with polarity as shown in the
battery compartment. Dispose used batteries in accordance with
local environmental regulations. Dispose alarm unit and sensor in
a similar way as non-hazardous electronic products are disposed.
BATTERY REPLACEMENT &DISPOSAL
The Chummie bedwetting alarm treatment system is designed to
operate in temperatures between 30°F-120°F (0°C-50°C). If the
system is not going to be used for an extended period of time,
disconnect the sensor from the alarm unit, remove batteries from
the alarm unit, and store in a cool, dry place.
LONG TERM STORAGE
IntelliFlex Sensor
After each use, rinse both surfaces of the sensor with warm tap
water and gently pat dry with a soft cloth. Do not use soap or
detergent. Do not pull on the sensor cord. Do not pierce, cut or
scratch the sensor.
For daytime storage, disconnect the sensor from the alarm unit.
The alarm unit automatically enters standby (power save) mode.
Chummie Alarm Unit
The alarm unit is not waterproof; keep it dry at all times. Do not
allow the alarm unit to come in contact with liquids. Do not
immerse the alarm unit in water. Do not operate with wet hands.
To clean the alarm unit, scrub gently with a soft cloth.
CARE &MAINTENANCE
To stop an active alarm, disconnect the sensor from the alarm unit
and briefly press the program switch. Alarm lights, tones and/or
vibration will stop, signaling that the alarm unit has entered stand-
by (power save) mode. Wash both surfaces of the sensor with
warm water and pat dry with a soft cloth. Ensure sensor is
completely dry. Replace wet/soiled clothing and reinstall the
alarm unit and sensor to continue monitoring for the remainder of
the night.
E
N
G
L
I-
S
H
ALARM MANAGEMENT &REUSE
To start monitoring for bedwetting events, insert the sensor plug
into the sensor jack. The alarm unit will beep twice signaling a
successful connection has been established.
2954 Scott Blvd
Santa Clara, CA 95054, USA.
Tel: (408) 239-4050. Fax: (408) 599-3020
Toll free: (800) 230-6775 (USA)
email: [email protected]
www.chummie.com
front must face your child. Run sensor cord underneath the shirt.
Fasten the alarm unit to the
outside neckline or around
arm with optional armband
accessory (sold separately).
Attach the sensor to the
outside of your child’s
undergarment. Ensure that
sensor front (black face)
touches the undergarment.
Tape the sensor back (white
face) with Flexitape (includ-
ed).
Optionally, tape the sensor
and place between two pairs
of undergarments. Sensor
I
NSTALLING
A
LARM
U
NIT
&
S
ENSOR
♦ Sound and vibrate mode: Press and release the program switch
till the alarm unit beeps and vibrates simultaneously. Both
sound (gren) and vibrate (amber) icons will flash.
♦ Sound mode: To enable sound and turn off vibration, press and
release the program switch till the alarm unit beeps and
vibration turns off. Only the sound (green) icon will flash.
♦ Discreet mode: To enable vibration and turn off sound, press
and release the program switch till the alarm unit vibrates and
sound turns off. Only the vibrate (amber) icon will flash.
The alarm tone last played will be selected and the unit will
enter standby (power save) mode 10 seconds after the last
adjustment is made with the program switch.
You can select among 3 alarm
configurations: sound and vibra-
tion, sound only and vibrate
only. To select the alarm configu-
ration, disconnect the sensor
from the alarm unit by removing
the sensor plug from the sensor
jack and follow the steps below.
S
ETTING
T
ONES
&
V
IBRATION
To extend battery life, disconnect sensor from the
alarm unit when not in use.
If the red LED on the alarm unit glows, the batteries
are weak. Replace the batteries promptly.
Tones are changed by the alarm unit each time the
sensor is disconnected and reconnected.
After each use, rinse both surfaces of the sensor with
warm tap water and gently pat dry. Do not use soap.
Remove the snap-on clip from the back of the alarm unit by
pressing upwards from the bottom of the clip or by releasing the
alarm unit from the sides of the clip. Open the battery compart-
ment door by sliding it towards the bottom of the alarm unit.
Install 2 AAA batteries (included). The alarm unit turns on. The
sound and vibrate icons light up and unit beeps and vibrates for
1 second. Gently slide the battery compartment door toward the
top of the alarm unit to close. Reinstall the snap-on clip.
I
NSTALLING
B
ATTERIES
A - Snap-On Clip B - Sensor Jack C- Battery Door
D - Program Switch E - Smart LED’s
D
B
CE
A
K
NOW
Y
OUR
C
HUMMIE
DETAILED INSTRUCTIONS FOR USE
[email protected]
8
7
6
5
4
3
2
1
QUICK START GUIDE

Popular Medical Equipment manuals by other brands

Air Liquide Soffio PLUS manual

Air Liquide

Air Liquide Soffio PLUS manual

Gima 600G ECG manual

Gima

Gima 600G ECG manual

Otto Bock AxonSoft 2.2 560X500 V2.2 Instructions for use

Otto Bock

Otto Bock AxonSoft 2.2 560X500 V2.2 Instructions for use

Invivo dS HiRes Hand/Wrist 16ch 1.5T Instructions for use

Invivo

Invivo dS HiRes Hand/Wrist 16ch 1.5T Instructions for use

BEYES CareMaster Instructions for use

BEYES

BEYES CareMaster Instructions for use

Esaote MyLabX75 Series Getting started

Esaote

Esaote MyLabX75 Series Getting started

Medicap Precise 6000 Operation manual

Medicap

Medicap Precise 6000 Operation manual

elektron eye technology Henson 9000 quick start guide

elektron eye technology

elektron eye technology Henson 9000 quick start guide

CardiAid CT0207RS User Manual and Introduction to the Device

CardiAid

CardiAid CT0207RS User Manual and Introduction to the Device

Medisana HS 680 instruction manual

Medisana

Medisana HS 680 instruction manual

Confycare FIX-MT2 Assembly instruction

Confycare

Confycare FIX-MT2 Assembly instruction

Drive RTL12068 quick guide

Drive

Drive RTL12068 quick guide

Shenzhen Creative Industry Co. Oxy-One Plus user manual

Shenzhen Creative Industry Co.

Shenzhen Creative Industry Co. Oxy-One Plus user manual

Saadat SHOOKA user manual

Saadat

Saadat SHOOKA user manual

Puritan Bennett Breeze SleepGear user guide

Puritan Bennett

Puritan Bennett Breeze SleepGear user guide

Boston Scientific SpyGlass DS quick start guide

Boston Scientific

Boston Scientific SpyGlass DS quick start guide

Beurer AFTER 45 quick start guide

Beurer

Beurer AFTER 45 quick start guide

Medline MDS400ELB owner's manual

Medline

Medline MDS400ELB owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.