Instructions for safe use
Cautions
WARNING
• The elevator wire at the distal end is damaged (broken, frayed, or bent), the damaged elevator
wire may cause injury or pose an infection control risk when detaching of the distal cover or
cleaning the endoscope. In this case, carefully detach the distal cover and perform cleaning.
CAUTION
•If the elevator wire at the distal end is either damaged, broken, frayed or bent, the equipment
may not function properly and may also compromise patient operator or other medical
personnel safety resulting in more severe equipment damage.
• When attaching the distal cover, make sure to confirm that the portion of the elevator wire at the
distal end is not broken, frayed or bent. Otherwise, the broken elevator wire may cause injury.
Also, if the broken elevator wire is deformed, it may compromise patient, operator or other
medical personnel safety.
This instruction includes special care points for safe usage excerpted from the Instruction Manual of Olympus TJF TYPE
160VR duodenovideoscope. These points are particularly important and should be noted when using Olympus TJF TYPE
160VR duodenovideoscope. Before using the scopes, read the “Instruction Manual” carefully and follow the instructions.
If an abnormality is detected before or during usage, or the equipment is malfunctioning, do not use the equipment and
contact Olympus to request repair.
RC5688 01
©2018 OLYMPUS MEDICAL SYSTEMS CORP. All rights reserved.
Printed in Japan 2018XXXX *0000
Inspection of the elevator wire at the distal end
The qualified user should inspect the elevator wire at the distal end according to the following procedure.
Visually confirm that the elevator wire at the distal end is not broken, frayed or bent, when moving the
elevator control lever to make the forceps elevator “raise ⇔lower”.
If any irregularity is observed during the inspection described in Chapter 3 of the Instruction Manual, “Preparation and
Inspection”, do not use the endoscope and solve the problem as described in Section 5.1, “Troubleshooting guide”. If the
problem still cannot be resolved, send the endoscope to Olympus for repair as described in Section 5.3, “Returning the
endoscope for repair”. Also, should any abnormality be observed while using the endoscope, stop using it immediately and
withdraw the endoscope from the patient as described Section in 5.2, “Withdrawal of the endoscope with an abnormality”.
“raise ↔lower”
Not OK
Not OK
Not OK
OK
Forceps elevator
Forceps elevator
Forceps elevator
Elevator wire
Elevator wire
Elevator wire
Break
Break
Break
Fray
Fray
Fray
Fray and bend
Fray and bend
Fray and bend
AUTHORIZED REPRESENTATIVE IN THE EUROPEAN COMMUNITY
438B Alexandra Road #03-07/12, Alexandra Technopark Blk B, Singapore 119968
Fax: 6834-2438 Telephone: 6834-0010
2F-3F Majestar City Tower One, 12, Seocho-daero 38-gil, Seocho-gu, Seoul,
06655, Korea
Fax: (02)6255-3210 Telephone: 1544-3202
(Premises/Goods delivery) Wendenstrasse 14-18, 20097 Hamburg, Germany
(Letters) Postfach 10 49 08, 20034 Hamburg, Germany
Fax: (040)23773-4656 Telephone: (040)23773-0
Manufactured by
MANUFACTURER
2951 Ishikawa-cho, Hachioji-shi, Tokyo 192-8507, Japan Fax: (042)646-2429 Telephone: (042)642-2111
Distributed by
KeyMed House, Stock Road, Southend-on-Sea, Essex SS2 5QH, United Kingdom
Fax: (01702)465677 Telephone: (01702)616333
Elektrozavodskaya str. 27 bld.8, 107023 Moscow, Russia
Fax: (7)495-926-7072 Telephone: (7)495-926-7077
3500 Corporate Parkway, P.O. Box 610, Center Valley, PA 18034-0610, U.S.A.
Fax: (484)896-7128 Telephone: (484)896-5000
5301 Blue Lagoon Drive, Suite 290 Miami, FL 33126-2097, U.S.A.
Fax: (305)261-4421 Telephone: (305)266-2332
A8F, Ping An International Financial Center, No. 1-3, Xinyuan South Road,
Chaoyang District, Beijing, 100027 P.R.C.
Fax: (86)10-5976-1299 Telephone: (86)10-5819-9000
3 Acacia Place, Notting Hill, VIC 3168, Australia
Fax: (03)9543-1350 Telephone: (03)9265-5400

Other Olympus Medical Equipment manuals

Olympus OLYMPUS OSF-3 User manual

Olympus

Olympus OLYMPUS OSF-3 User manual

Olympus BF UC180F User manual

Olympus

Olympus BF UC180F User manual

Olympus EVIS EXERA II User manual

Olympus

Olympus EVIS EXERA II User manual

Olympus ESG-300 User manual

Olympus

Olympus ESG-300 User manual

Olympus EVIS X1 User manual

Olympus

Olympus EVIS X1 User manual

Olympus EVIS EXERA II User manual

Olympus

Olympus EVIS EXERA II User manual

Olympus ESG-400 User manual

Olympus

Olympus ESG-400 User manual

Olympus CelonLab ENT User manual

Olympus

Olympus CelonLab ENT User manual

Olympus EVIS EXERA II User manual

Olympus

Olympus EVIS EXERA II User manual

Olympus MAJ-2336 User manual

Olympus

Olympus MAJ-2336 User manual

Olympus EXERA BF-160 Series Bronchovideoscope User manual

Olympus

Olympus EXERA BF-160 Series Bronchovideoscope User manual

Olympus PCF 160AL/I User manual

Olympus

Olympus PCF 160AL/I User manual

Olympus EVIS EXERA II User manual

Olympus

Olympus EVIS EXERA II User manual

Olympus HiQ+ User manual

Olympus

Olympus HiQ+ User manual

Olympus VISERA ELITE II User manual

Olympus

Olympus VISERA ELITE II User manual

Olympus K-401 User manual

Olympus

Olympus K-401 User manual

Olympus BF-P190 User manual

Olympus

Olympus BF-P190 User manual

Olympus ORBEYE OME-V200 User manual

Olympus

Olympus ORBEYE OME-V200 User manual

Olympus CLV-160 User manual

Olympus

Olympus CLV-160 User manual

Olympus IPLEX FX User manual

Olympus

Olympus IPLEX FX User manual

Olympus MAJ-2501 User manual

Olympus

Olympus MAJ-2501 User manual

Olympus EVIS EXERA TJF-160VR User manual

Olympus

Olympus EVIS EXERA TJF-160VR User manual

Olympus PSD-30 User manual

Olympus

Olympus PSD-30 User manual

Olympus GIF-H190 User manual

Olympus

Olympus GIF-H190 User manual

Popular Medical Equipment manuals by other brands

Pivotell Advance GSM instructions

Pivotell

Pivotell Advance GSM instructions

SAIC RTR-4 Operator's manual

SAIC

SAIC RTR-4 Operator's manual

Askle Sante Winncare Automorpho Plus user manual

Askle Sante

Askle Sante Winncare Automorpho Plus user manual

Beurer IH 26 Kids Instructions for use

Beurer

Beurer IH 26 Kids Instructions for use

PROVOX Luna Series manual

PROVOX

PROVOX Luna Series manual

Bauerfeind uniprox DAHO 2.6 Series instruction manual

Bauerfeind

Bauerfeind uniprox DAHO 2.6 Series instruction manual

laerdal SimJunior Quick setup guide

laerdal

laerdal SimJunior Quick setup guide

Boston Scientific VERCISE DBS Handbook

Boston Scientific

Boston Scientific VERCISE DBS Handbook

Drive DeVilbiss Sidhil 1006100001 user manual

Drive DeVilbiss

Drive DeVilbiss Sidhil 1006100001 user manual

SDI Astra 300 user manual

SDI

SDI Astra 300 user manual

Ergomotion quest 4.0 owner's manual

Ergomotion

Ergomotion quest 4.0 owner's manual

natus ICS Impulse quick guide

natus

natus ICS Impulse quick guide

Corventis NUVANT Instructions for use

Corventis

Corventis NUVANT Instructions for use

fiagon Navigation Unit Cube 4D Instructions for use

fiagon

fiagon Navigation Unit Cube 4D Instructions for use

PHILIPS Respironics CoughAssist Patient guide

PHILIPS Respironics

PHILIPS Respironics CoughAssist Patient guide

Dräger Primus Infinity Empowered Quick reference guide

Dräger

Dräger Primus Infinity Empowered Quick reference guide

NURSE ROSIE Rosebud VC troubleshooting guide

NURSE ROSIE

NURSE ROSIE Rosebud VC troubleshooting guide

MIETHKE GAV Patient Handbook

MIETHKE

MIETHKE GAV Patient Handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.