manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Olympus
  6. •
  7. Medical Equipment
  8. •
  9. Olympus TJF 160VR Quick guide

Olympus TJF 160VR Quick guide

Other Olympus Medical Equipment manuals

Olympus CV-180 User manual

Olympus

Olympus CV-180 User manual

Olympus ScopeGuide UPD-3 User manual

Olympus

Olympus ScopeGuide UPD-3 User manual

Olympus HysteroFlow/HysteroBalance II User manual

Olympus

Olympus HysteroFlow/HysteroBalance II User manual

Olympus EVIS EUS EU-ME2 User manual

Olympus

Olympus EVIS EUS EU-ME2 User manual

Olympus VISERA ENF-V2 User manual

Olympus

Olympus VISERA ENF-V2 User manual

Olympus MAJ-2414 User manual

Olympus

Olympus MAJ-2414 User manual

Olympus ENDOCAPSULE 10 SYSTEM User manual

Olympus

Olympus ENDOCAPSULE 10 SYSTEM User manual

Olympus QuickClip Pro HX-202LR User manual

Olympus

Olympus QuickClip Pro HX-202LR User manual

Olympus CLV-180 User manual

Olympus

Olympus CLV-180 User manual

Olympus MAJ-2485 User manual

Olympus

Olympus MAJ-2485 User manual

Olympus OTV-SI User manual

Olympus

Olympus OTV-SI User manual

Olympus EU-ME2 User manual

Olympus

Olympus EU-ME2 User manual

Olympus EVIS X1 User manual

Olympus

Olympus EVIS X1 User manual

Olympus K-401 User manual

Olympus

Olympus K-401 User manual

Olympus BF UC180F User manual

Olympus

Olympus BF UC180F User manual

Olympus Single Use Cannula V StarTip V User manual

Olympus

Olympus Single Use Cannula V StarTip V User manual

Olympus OLYMPUS BF TYPE 160 User manual

Olympus

Olympus OLYMPUS BF TYPE 160 User manual

Olympus OEP-5 User manual

Olympus

Olympus OEP-5 User manual

Olympus GIF XP160 User manual

Olympus

Olympus GIF XP160 User manual

Olympus PolyLoop HX-400U-30 User manual

Olympus

Olympus PolyLoop HX-400U-30 User manual

Olympus BF UC180F User manual

Olympus

Olympus BF UC180F User manual

Olympus EVIS EXERA II User manual

Olympus

Olympus EVIS EXERA II User manual

Olympus OER-Elite User manual

Olympus

Olympus OER-Elite User manual

Olympus BF P60 User manual

Olympus

Olympus BF P60 User manual

Popular Medical Equipment manuals by other brands

Itamar Medical WatchPAT Operation manual

Itamar Medical

Itamar Medical WatchPAT Operation manual

PROTEOR 1P650 KNEE Assembling and adjustment instructions

PROTEOR

PROTEOR 1P650 KNEE Assembling and adjustment instructions

Liberate Medical VentFree user manual

Liberate Medical

Liberate Medical VentFree user manual

Dicarre DA20 user guide

Dicarre

Dicarre DA20 user guide

Stryker Medical M Series Operation manual

Stryker Medical

Stryker Medical M Series Operation manual

Invacare ScanBed 750 user manual

Invacare

Invacare ScanBed 750 user manual

Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Getinge

Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics Sonicator 730 Maintenance manual

Mettler Electronics

Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care R1100 Mounting instruction

Pressalit Care

Pressalit Care R1100 Mounting instruction

Denas MS DENAS-T operating manual

Denas MS

Denas MS DENAS-T operating manual

bort medical ActiveColor quick guide

bort medical

bort medical ActiveColor quick guide

AccuVein AV400 user manual

AccuVein

AccuVein AV400 user manual

agiliti NP Trio user manual

agiliti

agiliti NP Trio user manual

Rocket Medical Rocket Digital Oocyte Aspiration Pump Service manual

Rocket Medical

Rocket Medical Rocket Digital Oocyte Aspiration Pump Service manual

Monteris Medical Neuroblate Instructions for use

Monteris Medical

Monteris Medical Neuroblate Instructions for use

Otto Block 8E33 7 manual

Otto Block

Otto Block 8E33 7 manual

ADVANCED HOME CARE Helios Guide

ADVANCED HOME CARE

ADVANCED HOME CARE Helios Guide

NeuLog NUL-208 Guide

NeuLog

NeuLog NUL-208 Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Instructions for safe use
Cautions
WARNING
• The elevator wire at the distal end is damaged (broken, frayed, or bent), the damaged elevator
wire may cause injury or pose an infection control risk when detaching of the distal cover or
cleaning the endoscope. In this case, carefully detach the distal cover and perform cleaning.
CAUTION
•If the elevator wire at the distal end is either damaged, broken, frayed or bent, the equipment
may not function properly and may also compromise patient operator or other medical
personnel safety resulting in more severe equipment damage.
• When attaching the distal cover, make sure to confirm that the portion of the elevator wire at the
distal end is not broken, frayed or bent. Otherwise, the broken elevator wire may cause injury.
Also, if the broken elevator wire is deformed, it may compromise patient, operator or other
medical personnel safety.
This instruction includes special care points for safe usage excerpted from the Instruction Manual of Olympus TJF TYPE
160VR duodenovideoscope. These points are particularly important and should be noted when using Olympus TJF TYPE
160VR duodenovideoscope. Before using the scopes, read the “Instruction Manual” carefully and follow the instructions.
If an abnormality is detected before or during usage, or the equipment is malfunctioning, do not use the equipment and
contact Olympus to request repair.
RC5688 01
©2018 OLYMPUS MEDICAL SYSTEMS CORP. All rights reserved.
Printed in Japan 2018XXXX *0000
Inspection of the elevator wire at the distal end
The qualified user should inspect the elevator wire at the distal end according to the following procedure.
Visually confirm that the elevator wire at the distal end is not broken, frayed or bent, when moving the
elevator control lever to make the forceps elevator “raise ⇔lower”.
If any irregularity is observed during the inspection described in Chapter 3 of the Instruction Manual, “Preparation and
Inspection”, do not use the endoscope and solve the problem as described in Section 5.1, “Troubleshooting guide”. If the
problem still cannot be resolved, send the endoscope to Olympus for repair as described in Section 5.3, “Returning the
endoscope for repair”. Also, should any abnormality be observed while using the endoscope, stop using it immediately and
withdraw the endoscope from the patient as described Section in 5.2, “Withdrawal of the endoscope with an abnormality”.
“raise ↔lower”
Not OK
Not OK
Not OK
OK
Forceps elevator
Forceps elevator
Forceps elevator
Elevator wire
Elevator wire
Elevator wire
Break
Break
Break
Fray
Fray
Fray
Fray and bend
Fray and bend
Fray and bend
AUTHORIZED REPRESENTATIVE IN THE EUROPEAN COMMUNITY
438B Alexandra Road #03-07/12, Alexandra Technopark Blk B, Singapore 119968
Fax: 6834-2438 Telephone: 6834-0010
2F-3F Majestar City Tower One, 12, Seocho-daero 38-gil, Seocho-gu, Seoul,
06655, Korea
Fax: (02)6255-3210 Telephone: 1544-3202
(Premises/Goods delivery) Wendenstrasse 14-18, 20097 Hamburg, Germany
(Letters) Postfach 10 49 08, 20034 Hamburg, Germany
Fax: (040)23773-4656 Telephone: (040)23773-0
Manufactured by
MANUFACTURER
2951 Ishikawa-cho, Hachioji-shi, Tokyo 192-8507, Japan Fax: (042)646-2429 Telephone: (042)642-2111
Distributed by
KeyMed House, Stock Road, Southend-on-Sea, Essex SS2 5QH, United Kingdom
Fax: (01702)465677 Telephone: (01702)616333
Elektrozavodskaya str. 27 bld.8, 107023 Moscow, Russia
Fax: (7)495-926-7072 Telephone: (7)495-926-7077
3500 Corporate Parkway, P.O. Box 610, Center Valley, PA 18034-0610, U.S.A.
Fax: (484)896-7128 Telephone: (484)896-5000
5301 Blue Lagoon Drive, Suite 290 Miami, FL 33126-2097, U.S.A.
Fax: (305)261-4421 Telephone: (305)266-2332
A8F, Ping An International Financial Center, No. 1-3, Xinyuan South Road,
Chaoyang District, Beijing, 100027 P.R.C.
Fax: (86)10-5976-1299 Telephone: (86)10-5819-9000
3 Acacia Place, Notting Hill, VIC 3168, Australia
Fax: (03)9543-1350 Telephone: (03)9265-5400