Cisco 6200 Use and care manual

78-5294-02 10/02/98
Cisco Systems, Inc.
All rights reserved.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
Cisco Systems, Inc.
Corporate Headquarters
Copyright © 1998
1
Cisco 6200 FRU Installation and
Replacement
Read this document to learn how to install and remove field-replaceable units (FRUs) in the
Cisco 6200 advanced digital subscriber line access multiplexer (DSLAM).
A Cisco 6200 DSLAM contains at least one of each of these FRUs:
•Network trunk card (NTC)
•Management processor card (MPC)
•Subscriber line card (SLC)
•Power entry module (PEM)
•Fan tray with air filter
•Dangler cable
This document includes the following sections:
•Installing and Removing Cards, page 2
•Installing and Removing a Power Entry Module (PEM), page 8
•Installing and Removing a Fan Tray, page 10
•Installing and Removing Dangler Cables, page 12
Cisco documentation and additional literature are available in a CD-ROM package, which ships with
your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated
monthly. Therefore, it might be more current than printed documentation. To order additional copies
of the Documentation CD-ROM, contact your local sales representative or call customer service.
The CD-ROM package is available as a single package or through an annual subscription. You can
also access Cisco documentation on the World Wide Web at http://www.cisco.com,
http://www-china.cisco.com, or http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments
electronically. Click Feedback in the toolbar and select Documentation. After you complete the
form, click Submit to send it to Cisco. We appreciate your comments.
The safety warnings in this document have been translated into several foreign languages. See
Appendix C, “Translated Safety Warnings,” in the Cisco 6200 User Guide.

Installing and Removing Cards 78-5294-02 10/02/98
2Cisco 6200 FRU Installation and Replacement
Warning Before working on equipment that is connected to power lines, remove jewelry (including rings,
necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause
serious burns or weld the metal object to the terminals.
Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.
Warning Only trained and qualified personnel should be allowed to install or replace this equipment.
1. Installing and Removing Cards
1.1 Installing Cards in the Cisco 6200
Follow the procedures in this section to install MPCs, NTCs, and SLCs. It is not necessary to
disconnect power before inserting any card into the Cisco 6200 chassis.
Note All the SLCs in a Cisco 6200 chassis should be of the same type. The mixture of CAP and
DMT cards in a single chassis is not supported.
If you are installing a single-mode NTC OC-3 or NTC STM-1 card, read the following warnings.
Warning Class 1 laser product.
Warning Because invisible laser radiation may be emitted from the aperture of the port when no cable is
connected, avoid exposure to laser radiation and do not stare into open apertures.
The fiber optic communication channels in the single-mode OC-3 and STM-1 cards (NTC OC3-SM
and NTC STM1-SM) operate with laser energy, which can be harmful, especially to the eyes. During
normal operation, this energy is confined to the cable and presents no danger. To avoid injury when
you are connecting or disconnecting optical channels, observe these precautions: always disconnect
the card from the backplane before connecting or disconnecting optical cables; always keep the
protective cap on the optic connector when the connector is not in use; and never look into an optical
cable or connector.
These cautions apply to all Cisco 6200 cards:
Caution Static voltages as low as 30 volts can cause latent damage to circuitry. Be sure to observe all
standard anti-static procedures (for example, wear a grounding strap).
Caution To avoid damage to either the card or the corresponding backplane connectors, be sure that you
understand and follow the proper procedure for inserting a card into the shelf. Damage may result if you
install a card into a slot of the wrong type, or if you install a card improperly.

78-5294-02 10/02/98 Installing and Removing Cards
Cisco 6200 FRU Installation and Replacement 3
1.1.1 Card Installation
To insert a card into the Cisco 6200 shelf, follow these steps:
Step 1 If you are installing a replacement MPC, remove the PCMCIA Flash card from the old
MPC and place it in the left PCMCIA slot in the new MPC.
Step 2 Select a slot compatible with the type of card you are inserting. An NTC must go in slot 1;
an MPC must go in slot 2; SLCs go in slots 5 through 14.
Step 3 Hold the card vertically, with the card’s faceplate toward you and connectors away from
you. Ensure that it is right side up by noting the lettering on the faceplate.
Step 4 Carefully align the upper and lower edges of the card with the upper and lower guides in
the shelf.
Caution To ensure that the card mates properly with connector pins on the backplane, the card length and
card slots have been designed with very close tolerances. To slide the card into the slot requires gentle
pressure with each hand, at the top and bottom of the faceplate.
Step 5 Gently insert the card into the slot. Stop when contact is first made between the card and
the backplane.
Step 6 Ensure that the card’s upper and lower insertion/extraction levers engage the upper and
lower front rails of the enclosure. See Figure 1.
Figure 1 Card Insertion
Step 7 Press the upper lever down and the lower lever up at the same time. (This action
electrically connects the card to the backplane.)
Step 8 Secure the card to the enclosure by tightening the upper and lower retaining screws.
Step 9 Repeat Step 2 through Step 8 to install additional cards.
12700
Top lever
Bottom lever
Retaining screw
Top rail
Faceplate
Card
Guide
Bottom rail
Retaining screw
Front view of Cisco 6200 chassis

Installing and Removing Cards 78-5294-02 10/02/98
4Cisco 6200 FRU Installation and Replacement
When a card is inserted, the green POWER LED on its faceplate turns on. The card
performs an internal confidence test. Each card’s READY LED turns on when the card
successfully completes its test.
Step 10 Install blank faceplates to cover any unused slots in the chassis. Like cards, faceplates are
each held in place by two retaining screws.
Warning Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that
might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the
system unless all cards, faceplates, front covers, and rear covers are in place.
Step 11 How to proceed:
•If you installed an NTC, do the following:
—Attach the appropriate trunk cable to the port on the faceplate.
—You may wish to monitor and manage the NTC using the Cisco 6200 Manager
software, a graphical user interface (GUI) management application. In order to
use the GUI to manage the NTC, you must provision the NTC in the GUI. See the
User Guide for the Cisco 6200 Manager for instructions on using the GUI.
You can also use the command line interface (CLI) to monitor and manage the
NTC. For the CLI, no configuration of the NTC is required.
•If you installed an MPC, do the following:
—Attach the console cable to the CNSL port on the faceplate.
—If you are using Ethernet for out-of-band management of the Cisco 6200, attach
an Ethernet cable to the ENET port on the faceplate.
—Skip to the “Additional Steps for MPC Replacement” section on page 6.
•If you installed an SLC, do the following:
—Proceed to the “Software Configuration for SLCs” section, below.
—Connect a cable to the appropriate subscriber port or dangler cable on the rear of
the chassis. See the “Installing Dangler Cables on the Cisco 6200” section on
page 12.
Warning The ports labeled “Ethernet,” “ENET,” “ETH1,” “ETH2,” “CNSL,” and “Serial Port” are safety
extra-low voltage (SELV) circuits. SELV circuits should be connected only to other SELV circuits. Because
the DSL circuits are treated like telephone-network voltage, avoid connecting the SELV circuit to the
telephone network voltage (TNV) circuits.
1.1.2 Software Configuration for SLCs
Software configuration for new SLCs is performed using either the Cisco 6200 Manager software (a
graphical user interface (GUI) management application) or the command line interface (CLI) to the
Cisco 6200. See the User Guide for the Cisco 6200 Manager for instructions on using the GUI.
This section explains how to use CLI commands to configure the SLC interfaces on a Cisco 6200
system. You can follow these steps before or after you insert the SLC into its slot in the chassis.

78-5294-02 10/02/98 Installing and Removing Cards
Cisco 6200 FRU Installation and Replacement 5
To configure an SLC, you must be in global configuration mode. If you are already in this mode, start
with Step 3.
Step 1 Enter the enable command and then enter the password to go into privileged mode:
c6200> enable
Enter Password:
Step 2 Enter the configure command and press Return to accept “terminal,” the default.
c6200# configure
Configuring from terminal, memory, or network [terminal]?
c6200(config)#
Step 3 If you already inserted the card you want to configure into its slot, go to Step 4. If the card
is not in the slot, use this step to preconfigure the card.
Enter the c6200 card command and specify a slot number and card type. The SLC goes
into a slot with a number in the range 5 to 14 and has a card type of slc1-8-cap or
slc1-8-dmt. Each card has eight ports, numbered 0 to 7.In the following example, an SLC
8CAP is being preconfigured for slot 5.
c6200(config)# c6200 card 5 slc1-8-cap
Step 4 Enter the interface dsl command and specify the card and port you want to configure. In
this example, you configure port 0 of the SLC in slot 5.
c6200(config)# interface dsl 5/0
Step 5 Specify a subscriber name. In this example, the subscriber name “boston” is specified. If
you skip this step, the system provides a default subscriber name in the form port-type
slot/port, for example, “dsl 5/0.”
c6200(config-if)# dsl subscribername boston
Note Use the no dsl subscribername command to remove the subscriber name. This
command also changes all configuration values for this interface to default values.
Step 6 Specify downstream and upstream bit rates, which in this example have been set to 1600
and 272 kbps, respectively:
c6200(config-if)# dsl bitrate downstream 1600 upstream 272
Step 7 Activate the configuration by entering the no shutdown command and return to the
global configuration prompt by entering the end command.
c6200(config-if)# no shutdown
c6200(config-if)# end
c6200(config)#
Repeat Step 4 through Step 7 for each of the interfaces that you want to configure, and then follow
the step below to save the configuration to nonvolatile memory. If you do not save it, the
configuration will be lost when the device is rebooted.
Step 8 To save the configuration, use the end command to return to privileged EXEC mode, and
copy the running configuration to the startup configuration:
c6200# end
c6200# copy running-config startup-config

Installing and Removing Cards 78-5294-02 10/02/98
6Cisco 6200 FRU Installation and Replacement
Step 9 In addition to saving the configuration to the startup configuration, you may want to copy
it to a PCMCIA Flash memory card. The following command copies the startup
configuration to a file named “6200-config” on the PCMCIA card in slot 0.
c6200# copy startup-config slot0:6200-config
1.1.3 Additional Steps for MPC Replacement
If you are replacing an MPC, follow these steps after you complete the steps in the “Card
Installation” section on page 3. This procedure does not interrupt the flow of data.
Note In this procedure, it is assumed that you have prepared a backup PCMCIA Flash card, as
described in the Cisco 6200 User Guide in Chapter 6, “Preventive Maintenance.” The backup
PCMCIA card should contain the Cisco IOS software image and the current configuration file for
the system. The backup PCMCIA card should be moved from the old MPC to the new MPC before
the new MPC is installed in the chassis.
Step 1 At the console, look for this prompt and answer No:
Would you like to enter the initial configuration dialog? [yes]: no
Step 2 At the Router> or c6200> prompt, enter enable and the password to access privileged
EXEC mode:
C6200> enable
Password:
c6200#
Step 3 Enter the dir command to display the names of the files on the PCMCIA card in slot 0:
6200# dir slot0:
-#- -length- -----date/time------ name
1 1166308 Jul 06 1998 14:33:55 c6200-dcm-mz.113-1.DA1.bin
2 1121 Jul 06 1998 14:44:30 6200-config
19410616 bytes available (1167688 bytes used)
Step 4 Enter the copy command to copy the configuration file from the PCMCIA card to
running-config in memory:
6200# copy slot0:6200-config running-config
6200#
%SYS-5-CONFIG: Configured from slot0:6200-config by console #
Step 5 Enter another copy command to copy the configuration file from the PCMCIA card to
startup-config in NVRAM:
6200# copy slot0:6200-config startup-config
Building configuration...

78-5294-02 10/02/98 Installing and Removing Cards
Cisco 6200 FRU Installation and Replacement 7
Step 6 To enable the interfaces, enter the configure terminal command, followed by the
configuration commands shown in this example:
6200# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
6200(config)# int e0/0
6200(config-if)# no shut
6200(config-if)# int e0/1
6200(config-if)# no shut
6200(config-if)# int atm 1/0
6200(config-if)# no shut
6200(config-if)# exit
6200(config)# exit
6200# copy running-config startup-config
Building configuration...
[OK]
6200#
1.2 Removing Cards from the Cisco 6200
The procedure for removing MPCs, NTCs, and SLCs is the same. It is not necessary to disconnect
power before removing any card from the Cisco 6200 DSLAM.
Caution Static voltages as low as 30 volts can cause latent damage to circuitry. Be sure to observe all
standard anti-static procedures (for example, wear a grounding strap).
Step 1 Disconnect any cables connected to the card you are about to remove. If you are
disconnecting a single-mode OC-3 or STM-1 card, read the following warnings.
Warning Class 1 laser product.
Warning Because invisible laser radiation may be emitted from the aperture of the port when no cable is
connected, avoid exposure to laser radiation and do not stare into open apertures.
The fiber optic communication channels in the single-mode OC-3 and STM-1 cards (NTC OC3-SM
and NTC STM1-SM) operate with laser energy, which can be harmful, especially to the eyes. During
normal operation this energy is confined to the cable and presents no danger. To avoid injury when
connecting or disconnecting optical channels, observe these precautions: always disconnect the card
from the backplane before connecting or disconnecting optical cables; always keep the protective
cap on the optic connector when the connector is not in use; and never look into an optical cable or
connector.
Step 2 Unscrew the upper and lower retaining screws that secure the card to the chassis.
Step 3 Grasp the upper and lower extraction levers. Pull up on the upper lever while pushing
down on the lower lever. This action disengages the card from the connectors on the
backplane.
Step 4 Slide the card out of the chassis.
Step 5 Placethe card onan antistaticsurface. Ifit willbe out of the chassisfor anylength oftime,
put it in an antistatic shielding bag or in a box lined with antistatic material.
Step 6 In the empty slot, install another card of the same type or a blank faceplate.

Installing and Removing a Power Entry Module (PEM) 78-5294-02 10/02/98
8Cisco 6200 FRU Installation and Replacement
Warning Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that
might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the
system unless all cards, faceplates, front covers, and rear covers are in place.
1.2.1 Software Configuration
If you are removing the card permanently, update the system configuration using the Cisco 6200
Manager (GUI) or the command line interface (CLI). For instructions, see
•User Guide for the Cisco 6200 Manager
•Cisco 6200 User Guide (includes CLI procedures)
2. Installing and Removing a Power Entry Module (PEM)
2.1 Installing a PEM in the Cisco 6200
The power bays are located at front of the chassis, near the top. The bay on the left is wired to power
circuit A; the bay on the right is wired to power circuit B. (The circuits are identified at the power
terminals on the backplane.)
It is not necessary to disconnect power before inserting a PEM into the Cisco 6200 chassis. Follow
these steps:
Step 1 Ensure that the circuit breaker on the PEM is turned to OFF (0).
Step 2 Use a Phillips screwdriver to remove the front panel that partially covers the power bays.
Two Phillips-head quarter-turn fasteners are recessed into the face of the panel; insert the
screwdriver and turn the fastener 90 degrees in either direction to release it.
Step 3 Engage the sheet-metal carrier that forms the top of the PEM with the brackets on each
side of the power bay. (See Figure 2.)
Step 4 Firmly push the PEM all the way into the power bay to ensure that the power connectors
mate.
Step 5 Tighten the captive screw on the faceplate of the PEM to secure the PEM to the chassis.
Step 6 If the chassis is connected to power, turn the circuit breaker on the PEM to ON. A green
LED on the faceplate comes on to indicate that the PEM is providing power to the chassis.
Step 7 Replace the front panel and use a Phillips screwdriver to fasten it in place. You can look
through the rectangular opening in the panel as you engage the fasteners. Turn the
fastener 90 degrees in either direction to secure it.

78-5294-02 10/02/98 Installing and Removing a Power Entry Module (PEM)
Cisco 6200 FRU Installation and Replacement 9
Figure 2 Power Entry Module in the Cisco 6200 Chassis
2.2 Removing a PEM from the Cisco 6200
If you remove a PEM from a Cisco 6200 chassis in which a second PEM is installed and providing
power to the chassis, the chassis continues to operate normally. If you plan to remove the only
operating PEM from a chassis, you should shut down the system first.
2.2.1 Shutting Down the Cisco 6200
Follow these steps to shut down and turn off the DSLAM.
Step 1 Before shutting down the Cisco 6200, use the copy command to save any configuration
changes to NVRAM, and also, if you wish, to a PCMCIA Flash card. (See the command
reference chapter of the Cisco 6200 User Guide for instructions on using copy.)
Step 2 Allow any copy or write operations involving Flash media (PCMCIA slots or boot Flash)
to complete.
Step 3 Turn the circuit breakers on both PEMs to OFF (0).
2.2.2 Extracting a PEM
Follow these steps to remove a PEM from the Cisco 6200 chassis. If you are removing the only
operating PEM in an active system, follow the previous procedure, “Shutting Down the Cisco 6200,”
before performing these steps.
Step 1 Ensure that the circuit breaker on the PEM you are about to remove is turned to OFF (0).
Step 2 Use a Phillips screwdriver to remove the front panel that partially covers the power bays.
Two Phillips-head quarter-turn fasteners are recessed into the face of the panel; insert the
screwdriver and turn the fastener 90 degrees in either direction to release it.
Step 3 Unscrew the retaining screw in the PEM faceplate.
Step 4 Grasp the PEM by the handle on its faceplate and pull it out of the chassis.
12698
OI
Circuit
breaker
Front
panel
PEM
Retaining
screw
LED

Installing and Removing a Fan Tray 78-5294-02 10/02/98
10 Cisco 6200 FRU Installation and Replacement
Warning Hold the PEM by the sheet-metal carrier (top and front) only. Internal components may be hot.
Step 5 Replace the front panel and use the Phillips screwdriver to fasten it in place. You can look
through the rectangular opening in the panel as you engage the fasteners. Turn the
fastener 90 degrees in either direction to secure it.
3. Installing and Removing a Fan Tray
3.1 Installing the Fan Tray in the Cisco 6200
The fan tray is located at the bottom of the chassis, behind a removable panel. You need a Phillips
screwdriver to remove and replace the panel.
Caution The Cisco 6200 cooling fans must run continuously. The system may suffer thermal damage if the
fans stop for more than 10 minutes. (At ambient temperatures above 104 F(40 C),thermal damage may occur
sooner.)
Follow these steps to install the fan tray:
Step 1 Use a Phillips screwdriver to remove the panel that covers the fan tray (see Figure 3).
Step 2 Hold the fan tray so that the fans are on top, the air filter is on the bottom, and the wide
edge of the tray is facing away from you.
Step 3 Tilting the front edge of the fan tray downward, insert the wide edge of the tray so that it
clears the bottom lip of the chassis. (See Figure 3.)
Step 4 Engage the edges of the fan tray with the guides on either side of the slot in the chassis.
Ensure that the edges of the fan tray rest on top of the guides in the slot.
Step 5 Slide the tray gently into place. Press firmly to ensure that the power connectors mate. If
the chassis is receiving power, you will hear the fans start to turn.
Step 6 Use the Phillips screwdriver to replace the panel over the fan tray.

78-5294-02 10/02/98 Installing and Removing a Fan Tray
Cisco 6200 FRU Installation and Replacement 11
Figure 3 Fan Tray in the Cisco 6200
3.2 Removing the Fan Tray from the Cisco 6200
If you must remove the fan tray from a Cisco 6200, replace it within a few minutes. If that is not
possible, it is recommended that you shut down the system and turn off power to avoid thermal
damage.
Caution It is important that the system’s cooling fans run continuously. The system might suffer thermal
damage if the fans stop for more than ten minutes. (At ambient temperatures above 104 F(40C), thermal
damage can occur sooner.)
You need a Phillips screwdriver to perform this procedure.
Follow these steps to remove the fan tray:
Step 1 Use a Phillips screwdriver to remove the panel that covers the fan tray area at the bottom
front of the chassis.
Step 2 Grasp the fan tray with both hands and gently pull it toward you. If the fans are running,
you will hear them slow down as the tray disengages from its power connector.
Step 3 As you pull the fan tray from the chassis, tilt the front edge downwards so the wide rear
edge clears the lip at the bottom of the chassis. (See Figure 3.)
3.3 Air Filter Maintenance
Cleaning and replacement of the air filter in the fan tray is covered in the Cisco 6200 User Guide in
Chapter 6, “Preventive Maintenance.”
12699
E
N
E
T
Cisco6200
SERIES
Fan tray
Front panel
Air filter

Installing and Removing Dangler Cables 78-5294-02 10/02/98
12 Cisco 6200 FRU Installation and Replacement
4. Installing and Removing Dangler Cables
4.1 Installing Dangler Cables on the Cisco 6200
This procedure tells you how to attach dangler cables to the 50-pin Champ connectors on the back
of the Cisco 6200 DSLAM. (The Champs provide unshielded twisted pair (UTP) connections for
subscriber traffic.)
Thedangler cablesare numbered J1 through J10.Figure 4and Table 1showwhich Champconnector
each dangler cable should be attached to.
Figure 4 Attach Dangler Cables to Champ Connectors
Each dangler cable serves the subscriber line card (SLC) in a particular slot. The dangler cables
correspond to the SLC slots as shown in Table 1.
13064
J10
J9
J8
J7
J6
J5
J4
J3
J2
J1
Do not attach
a dangler cable
to this connector
Rear view of Cisco 6200 chassis

78-5294-02 10/02/98 Cisco Connection Online
Cisco 6200 FRU Installation and Replacement 13
Table 1 Dangler Cables Mapped to SLC Slots
You need a Phillips screwdriver to install the dangler cables. Follow these steps:
Step 1 Use a Phillips screwdriver to unfasten one of the two metal panels that cover the Champ
connectors on the back of the Cisco 6200. Each panel is held in place by six Phillips-head
quarter-turn fasteners. Turn each fastener 90 degrees in either direction to release it.
Step 2 Attach dangler cables to the five connectors (see Figure 4). Secure the cables with the
wire clips attached to the backplane connectors.
Step 3 Routethe danglercables towardthe sidesof thechassis: twotoone side,three tothe other.
Step 4 Replace the metal cover and use a Phillips screwdriver to fasten it in place. Turn each
fastener 90 degrees in either direction to secure it.
Step 5 Repeat this procedure, if necessary, to install dangler cables behind the other panel.
Note There are six Champ connectors behind the bottom panel. Do not attach a dangler
cable to the Champ connector located above and to the right of the other five connectors.
See Figure 4.
4.2 Removing Dangler Cables from the Cisco 6200
Follow these steps to remove dangler cables from the back of the Cisco 6200 DSLAM. You need a
Phillips screwdriver to perform this procedure.
Step 1 Use a Phillips screwdriver to unfasten one of the two metal panels that cover the dangler
cables on the back of the Cisco 6200. Each panel is held in place by six Phillips-head
quarter-turn fasteners. Turn each fastener 90 degrees in either direction to release it.
Step 2 Unfasten the two wire clips holding each dangler cable in place, and then pull the cable
off the connector.
Step 3 Replace the metal cover and use a Phillips screwdriver to fasten it in place. Turn each
fastener 90 degrees in either direction to secure it.
Step 4 Repeat this procedure, if necessary, to remove the dangler cables behind the other panel.
5. Cisco Connection Online
CiscoConnection Online(CCO) isCisco Systems’primary, real-timesupport channel.Maintenance
customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added
services to Cisco’s customers and business partners. CCO services include product information,
product documentation, software updates, release notes, technical tips, the Bug Navigator,
configuration notes, brochures, descriptions of service offerings, and download access to public and
authorized files.
J1 Slot 5 J6 Slot 10
J2 Slot 6 J7 Slot 11
J3 Slot 7 J8 Slot 12
J4 Slot 8 J9 Slot 13
J5 Slot 9 J10 Slot 14

Cisco Connection Online 78-5294-02 10/02/98
14 Cisco 6200 FRU Installation and Replacement
CCO serves a wide variety of users through two interfaces that are updated and enhanced
simultaneously: a character-based version and a multimedia version that resides on the World Wide
Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet
e-mail,and it isexcellentfor quickaccess to informationoverlowerbandwidths.The WWWversion
of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well
as hyperlinks to related information.
You can access CCO in the following ways:
•WWW: http://www.cisco.com
•WWW: http://www-europe.cisco.com
•WWW: http://www-china.cisco.com
•Telnet: cco.cisco.com
•Modem: From North America, 408 526-8070; from Europe, 33 1 64 46 40 82. Use the
following terminal settings: VT100 emulation; databits: 8; parity: none; stop bits: 1; and
connection rates up to 28.8 kbps.
Note If you are a network administrator and need personal technical assistance with a Cisco
product that is under warranty or covered by a maintenance contract, contact Cisco’s Technical
information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387,
This document is to be used in conjunction with the Cisco 6200 User Guide.
AccessPath, Any to Any, AtmDirector, the CCIE logo, CD-PAC, Centri, the Cisco Capital logo, CiscoLink, the Cisco NetWorks logo, the Cisco Powered Network logo, the Cisco Press
logo, ClickStart, ControlStream, DAGAZ, Fast Step, FireRunner, IGX, IOS, JumpStart, Kernel Proxy, LoopRunner, MGX, Natural Network Viewer, NetRanger, NetSonar, Packet, PIX,
Point and Click Internetworking, Policy Builder, RouteStream, Secure Script, SMARTnet, SpeedRunner, Stratm, StreamView, The Cell, TrafficDirector, TransPath, VirtualStream,
VlanDirector, Workgroup Director, and Workgroup Stack are trademarks; Changing the Way We Work, Live, Play, and Learn and Empowering the Internet Generation are service marks;
and BPX, Catalyst, Cisco, Cisco IOS, the Cisco IOS logo, Cisco Systems, the Cisco Systems logo, Enterprise/Solver, EtherChannel, FastHub, ForeSight, FragmentFree, IP/TV, IPX,
LightStream, MICA, Phase/IP, StrataSphere, StrataView Plus, and SwitchProbe are registered trademarks of Cisco Systems, Inc. in the U.S. and certain other countries. All other trademarks
mentioned in this document are the property of their respective owners. (9808R)
Copyright © 1998, Cisco Systems, Inc.
All rights reserved. Printed in USA.
Other manuals for 6200
1
Table of contents
Other Cisco Accessories manuals